Vous êtes sur la page 1sur 1

CENTRIFUGAL PUMP ( 60 HERTZ )

ELECTRO PUMP ENGINE POWER (TRIFASIC) 15 HP.

"1" QUANTITY: RPM (ENGINE) 1,800 RPM


DECK
F.F.L.
1 PIECE VOLTAGE - AMPERAGE 3 (240V). 35 amp.
+0.20 SUCTION DIAMETER

INTERACTIVE DISCHARGE DIAMETER

GAME T400 PUMP WEIGHT 180 kgs.


SERVICE WORK PRESSURE 10 m.w.c.
295 m3/hr HYDRAULIC PRESSURE
or KILOWATTS 11.19
82 L. P. S.

CENTRIFUGAL PUMP ( 60 HERTZ )


ELECTRO PUMP ENGINE POWER (TRIFASIC) 15 HP.

"2" QUANTITY: RPM (ENGINE) 1,800 RPM


1 PIECE VOLTAGE - AMPERAGE 3 (240V). 35 amp.
SUCTION DIAMETER

INTERACTIVE DISCHARGE DIAMETER

GAME T400 PUMP WEIGHT 180 kgs.


SERVICE WORK PRESSURE 10 m.w.c.
295 m3/hr
"1" "1" HYDRAULIC PRESSURE

0.92
or KILOWATTS 11.19
82 L. P. S.

WATER ACTIVITY POOL


DESIGN DATA
DECK
WATER PERIMETER 88 Meters
F.F.L. POOL
0.47 2
+0.20 WATER SURFACE AREA 600 M

0.30

0.28
MINIMUM 0.00 M
WATER DEPTH
MAXIMUM 0.40 M
0.23 0.91 3

0.92
DECK WATER VOLUME APROX. 240 M
F.F.L.
0.91 F.F.L. TURN OVER TIME 4 Hrs.
+0.00
+0.20

SIMBOL

F.F.L.
+0.00

REDUCTION

TANK
VOLUMEN:40M3

VALVE FLANGE
4.40

F.F.L. FINISH FLOOR LEVEL


F.W.L. FINISH WADING LEVEL
U.C.L. UPPER COLUMN LEVEL
S.S.L. STARTING SLIDE LEVEL
MACHINE
ROOM
F.F.L.
+0.00 1.- ALL DIMENSIONS AND LEVELS ARE IN METERS
2 1 2.- ALL LEVELS OF SLIDES SUPPORT ARE
REFERENCED AT +00.000
5.40

3.- SEE DRAWINGS C2647-02-HJ-02


HIDRAULICS DETAILS
4.- SEE DRAWINGS C2647-02-HJ-04
DETAILS OF MACHINE ROOM
5.- SEE DRAWINGS C2647-02-OC-01 & OC-02
LOCATION OF FOUNDATIONS & PLATES FOR INTERACTIVE GAME
DECK 6.- LEVELS OF AREA REFERRED TO FINISHED FLOOR LEVEL +00.000
F.F.L.
+0.20 7.- PIPES IN THE MACHINE ROOM WILL PVC Schedule 40 BOUND BY THE
DIAMETER SHOWN IN THE DRAWING, UNLESS OTHERWISE STATED.
ALL THE HYDRAULIC PIPE LINE MUST BE SUBTERRANEAN, AND UNDER
FREEZE LEVEL SPECIFIED IN THE CONSTRUCTION AREA.

8.- VALVES BUTTERFLIES IN THE MACHINE ROOM AND FLANGED


OPENING WILL INSTANTLY.
9.- CARRY OUT A PRESSURE TEST TO CHECK THE TIGHTNESS OF
THE SYSTEM. BEFORE ANY FINAL CONSTRUCTION WORK TO
PLANT VIEW PREVENT LEAKS
540.01 873.78 10.- FILTERING EQUIPMENT TO BE USED WATER SURGE TANK
11.- IS THE RESPONSIBILITY OF SUPERVISOR OF WORK, THE
REVISION OF ALL LEVELS IN THE AREA OF CONSTRUCTION FOR
VERIFICATION OF HEIGHTS AND STILL RETURNS IN PIPES
HYDRAULIC

(UNDERGROUND CONCRETE SLAB) 12.- ALL PIPING BEHIND THE CONCRETE WALLS (AND BENEATH
150 MINIMUN THICKNESS THE CONCRETE FLOOR) SHALL BE PLACED ON VERIFIED
COMPACTED SOIL OR SECURELY ATTACHED TO THE CONCRETE
WALLS IF THE REQUIRED BACKFILL AND COMPACTION CANNOT
0.40

BE ATTAINED,THEN ALL PIPING SHALL BE STRAPPED TO THE


F.F.L.
POOL SHELL AND THE MAXIMUN SPACING SHOWN BELOW.
+00.000
0.15
0.60

COMES FROM
PUMP

SECTION " 1 - 1 "


SCALE: 1:20

Vous aimerez peut-être aussi