Vous êtes sur la page 1sur 4

KEY INFORMATION

Analysis Type BIAXIAL ANALYSIS v2.4 Status DONE

Note : You can either use this button to launch the program, or directly provide the excel sheet to the program.

Upper Limits of Data Color Coding

NARI ROAD STN


Y/ML
Section Nodes 500 Title
Reinf. Bars 1000 Information PILE
Loadcase Nos 1000
X/MT
GENERAL NOTES:
1. INPUT UNITS are mm, N/mm2(MPa)
2. INPUT UNITS for Loads are kN, kNm
3. DO NOT INSERT COLUMNS , ROWS CAN BE INSERTED IN ANY FIELD UPTO ANY LIMIT
4. Always ensure that "S.No." column is properly filled. Otherwise, program may give some error.
5.M L is Moment about X-Axis, or we can also say, Moment in direction of Y-Axis.
6.M T is Moment about Y-Axis, or we can also say, Moment in direction of X-Axis.

ANALYSIS OPTIONS
Analysis Options Yes/No
Stress Check Yes
Crack Width Check (as per IRS/BS-5400) Yes
Crack Width Check (as per IRC-112) No
Ult. Moment Capacity Checks
Type 1 M/Mu Ratio Check Yes
Type 2 (ML/MuL)n + (MT/MuT)n Check No
P/M Chart No
ML/MT Chart No
Generate Output Yes (Use this option if you want to generate output in OUTPUT tab or not.)
Restrict Neutral Axis Rotation No (Use this option to restrict NA Angle to either 0 or 180 degree.)
Close After Analysis No (Use this option to Close the program, after it has completed the analysis, automatically.)

Material Properties
Concrete
Compressive strength (fck) 35 MPa
Material factor (m) 1.5
Young's modulus (Ec) 25000.0 MPa

Reinforcement Steel
Yield strength (Fy) 500 MPa
Material factor (m) 1.15
Young's modulus (Es) 200000 MPa

CODAL PROVISIONS
Stress Check
Concrete 17.5 MPa
Permissible
Compression Steel 375 MPa
Stresses
Tension Steel 375 MPa

Modular ratio Custom


Creep Coefficient (if Long Term) 1.00
Modular ratio (Tension Reinf.) (if Custom) 8.000
Modular ratio (Comp. Reinf.) (if Custom) 12.000

Crack Width Check (as per IRS/BS-5400)


Nominal Cover (cnom) 50 mm
Permissible Crack Width 0.25 mm

Modular ratio Custom


Creep Coefficient (if Long Term) 1.00
Modular ratio (Tension Reinf.) (if Custom) 8.000
Modular ratio (Comp. Reinf.) (if Custom) 12.000

Modular ratio Short Term

Ultimate Moment Capacity Check

Stress Strain Curve Selection (Refer Stress Strain Curve Definitions Manual provided in SUPPORT Folder)

Concrete Curve Selection IRS:Parabolic Reinf. Steel Curve Selection IRC112:Simplified Bilinear
-3 -3
Ultimate/Limiting Strain (cu) 3.5 x 10 Ulimate/Limiting Strain (uk) 50 x 10
-3
Strain at Characteristic Strength (c) 2 x 10 Ratio of uk & Design Strain (ud) 0.9
Exponent () 2 Ratio of ft/fyk 1
Effective Lateral Compressive Stress (2) 0 MPa

NOTE:
1. In case of Custom Curve, Max Strain value provided in the stress-strain curve of Concrete will be used as the Ultimate/limiting strain in Section Analysis.
2. Stress Strain curves must be provided with strain value in increasing order, starting from Zero.
Custom Curve - Concrete Custom Curve - Reinforcement Steel
Stress in
Stress in
S.No. x/Xu Strain x 10-3 Stress (MPa) S.No. Strain x 10-3 Compression
Tension (MPa)
(MPa)
1 1.00 0.0000 0.00 1 0.00 0.00 0.00
2 0.95 0.1750 2.62 2 2.17 434.78 434.78
3 0.90 0.3500 4.99 3 5.17 434.78 434.78
4 0.85 0.5250 7.13 4 8.17 434.78 434.78
5 0.80 0.7000 9.03 5 144.00 434.78 434.78
6 0.75 0.8750 10.69
7 0.70 1.0500 12.11
8 0.65 1.2250 13.29
9 0.60 1.4000 14.23
10 0.55 1.5750 14.93
11 0.50 1.7500 15.39
12 0.45 1.9250 15.61
13 0.40 2.1000 15.63
14 0.35 2.2750 15.63
15 0.30 2.4500 15.63
16 0.25 2.6250 15.63
17 0.20 2.8000 15.63
18 0.15 2.9750 15.63
19 0.10 3.1500 15.63
20 0.05 3.3250 15.63
21 0.00 3.5000 15.63

n n
Factor Depending on Axial Load in (M L /Mu L ) + (M T /Mu T ) Check

S.No. P/Pu n
1 -10.00 1.00
2 0.20 1.00
3 0.40 1.33
4 0.60 1.67
5 0.80 2.00
6 10.00 2.00

Use Resistance Factor () No


(Used in M/Mu Ratio Check, P/M Charts & M L /M T Charts only)

Resistance
S.No. Tensile Strain
Factor ()
1 0.0000 0.65
2 0.0020 0.65
3 0.0050 0.90
4 1.0000 0.90

Section Details
NOTE:
1. Section Coordinates Must be entered clockwise only.
2. First and the last point must be same. Means, Section must be closed.
3. When importing DXF, make a continuous P-Line for Section outline, and for circular or radial sections, make the section using small fragments.
4. For Voided sections, Make a continuous P-Line for Void outline, and place it in "VOID" or "Void" layer.
5. Reinforcement Coordinates and Section coordinates are imported at the same time from the same DXF Section File.
6. All the circles in the section file, will be considered as Reinforcement.

Type of Section Circle

DXF File Location to import (if selected)

For Rectangle
Height (H) mm
Breadth (B) mm

For Circle
Diameter (D) 800 mm

Custom Section Coordinates


Point No X (mm) Y (mm)
1
2
3
4

Reinforcement Details
NOTE:
1. Diameter of Reinforcement is increased due to Rings around it and thus, for calculating the Reinforcement Coordinates, Outer Diameter could be used. (Ratio of
Outer Diameter to Inner Diameter cannot be less than 1)
2. Program does not check, if the reinforcement provided meets the clea cover + stirrup requirements.
3. Clear cover & Diameter of Stirrup are crucial inputs required for Crack-Width calculations.

Ratio of Outer Diameter to Inner Diameter 1


Clear Cover to Stirrup (cc) 50 mm
Diameter of Stirrup 10 mm

For Circle
First Layer Second Layer Third Layer
Bar Dia (mm) 25
Alternate Bar Dia (mm)
Total No of Bars 8
Spacer Bar Dia (mm)

Loading Details
Stress Check
*Live Load values are used only if Interpolated Modular Ratio is selected.
Permanent Load Live Load*
P ML MT P ML MT
S.No.
(kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
1 2087 42
2 419 96
3 1332 355

Crack Width Check ( as per IRS/ BS-5400)


*Live Load values are used to calculate Mq/Mg ratio and Interpolated Modular Ratio.
Permanent Load Live Load*
P ML MT P ML MT
S.No.
(kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
1 1461 30 626 13
2 293 67 126 29
3 932 248 400 106

Ultimate Moment Capacity Check

M/Mu Ratio Check or (M L /Mu L ) n + (M T /Mu T ) n Check

P ML MT Resistance
S.No.
(kN) (kN.m) (kN.m) Factor ()
1 3100 72
2 8 129
3 939 488
RESULTS
Section Details
Cross-Sectional Area = 0.5010 m2
Area of Reinforcement = 3927 mm2
Number of Bars = 8

SLS Design - Stress Check


Concrete = 17.5
Permissible
Compression Steel = 375
Stresses
Tension Steel = 375

S.No. 1 2 3
P (kN) 2086.55 418.67 1331.91
ML (kN.m) 42.30020787 96.16842086 354.9312756
MT (kN.m) 0 0 0
NA Depth (m) 2.446 0.466959287 0.410834373
NA Angle (degree) (clockwise) 0.00 0 0
Stress in conc c ,MPa 4.57 3.012981571 11.66851715
sc ,MPa 53.27 30.54 115.31
Stress in steel
st ,MPa 0.00 -13.44878471 -71.95149267
Status OK OK OK

SLS Design - Crackwidth Check

Crack Width Check (as per IRS/BS-5400) S.No. 1 2


P (kN) 1460.585 293.069
Permanent load ML (kN.m) 29.61014551 67.317895
MT (kN.m) 0 0
P (kN) 625.965 125.601
Live load ML (kN.m) 12.69006236 28.850526
MT (kN.m) 0 0
Dist from crack to bar acr (mm) 0.00 0.00
Nominal cover cnom (mm) 50 50
Stirrup dia diam (mm) 10 10
Actual cover to Tension bar c(mm) 60 60
Effective cover for Eqn 24 cov (mm) 50 50
Depth in compression dc (m) 2.4463 0.4670
Overall Depth h (m) 0.7990 0.7990
Strain at crack ignoring stiffening 1 0.0000 0.0000
Depth to Centroid of Tension steel de (m) 0.0000 0.0000
Width at Centroid of Tension steel bt (m) 0.0000 0.5805
Compression face to crack a' (m) 0.0000 0.0000
Moment from Permanent Loads Mg (kN.m) 29.61 67.32
Moment from Live Loads Mq (kN.m) 12.69 28.85
Strain in rft. ignoring stiffening s 0.0000 0.0000
Area of tension rft. As (mm2) 0 1473
Strain adjustment to allow for stiffening 0.0000 0.0000
Strain adjustment taken 0.0000 0.0000
Strain at Crack after adjustment m 0.0000 0.0000
Crack Width (as per Equation 24) (mm) 0.0000 0.0000
Permissible Crack Width (mm) 0.250 0.250
Status No Cracking No Cracking

ULS Design - Moment Capacity Check

S.No. 1 2 3
P (kN) 3100.35 8.08 939.34
ML (kN.m) 71.98640453 129.4722355 487.6805216
MT (kN.m) 0 0 0
NA Depth (m) 0.39 0.16 0.23
NA Angle (degree) (clockwise) 0.00 0.00 0.00
M (kN.m) 71.99 129.47 487.68
Mu (kN.m) 960.70 512.69 723.99
Resistance Factor () NA NA NA
M/(Mu) 0.07 0.25 0.67
Status <=1, OK <=1, OK <=1, OK