Vous êtes sur la page 1sur 4

TECHNIQUE

Iris fixation of unstable anterior chamber


intraocular lenses
Julio Narvaez, MD, Enoch Nam, MD

Cataract surgeons are sometimes challenged with a patient who has an unstable anterior chamber
intraocular lens (AC IOL). Over time, an unstable AC IOL can lead to significant complications. This
problem is most often addressed with an IOL exchange using an appropriately sized AC IOL or a
posterior chamber IOL with iris or scleral fixation. We present a technique of 2-point iris fixation of
unstable AC IOLs as a simpler and less traumatic alternative.
Financial Disclosure: Neither author has a financial or proprietary interest in any material or
method mentioned.
J Cataract Refract Surg 2016; 42:961964 Q 2016 ASCRS and ESCRS
Online Video

Complications associated with anterior chamber intra- with a proper-sized AC IOL or a PC IOL fixated to the
ocular lenses (AC IOLs) have significantly decreased iris or sclera to prevent further complications. Explant-
since the advent of flexible open-loop AC IOLs.1 In ing these rigid AC IOLs requires large incisions, and
the past, the flawed design of the closed-loop AC these exchange procedures carry the risks for surgically
IOL led to a high incidence of corneal decompensation, induced astigmatism, suprachoroidal hemorrhage,
chronic intraocular inflammation, cystoid macular retinal detachment, and endophthalmitis.6
edema (CME), and glaucoma.2 The modern open- We report a simpler 2-point fixation technique of iris
loop AC IOLs are designed to have minimal vault fixation of the unstable AC IOL using a modified
and some haptic flexibility, thus minimizing damage Siepser knot as described by Osher et al.7 This is a valu-
to the corneal endothelium and angle structures. As able option to both patient and surgeon to resolve the
a result, numerous studies35 are finding open-loop clinical problem while avoiding the risks of more com-
AC IOLs to be a safe and comparable alternative to plex and traumatic surgeries.
sutured posterior chamber IOLs (PC IOLs).
Despite advances in AC IOL design, improper sizing
SURGICAL TECHNIQUE
of the IOL can lead to the same complications of closed-
loop IOLs. In general, these patients have IOL exchange After a local block is placed, the eye is prepared and
draped in the usual sterile fashion for ophthalmic sur-
gery. A paracentesis is placed superiorly, inferonasally,
Submitted: February 15, 2016. and inferotemporally. An intraocular miotic is used to
Final revision submitted: June 7, 2016. constrict the iris, and the anterior segment is filled
Accepted: June 7, 2016. with an ophthalmic viscosurgical device (OVD). The
unstable AC IOL is then rotated to a horizontal posi-
From the Department of Ophthalmology (Narvaez, Nam), Loma Lin-
tion, if the iris anatomy will allow, to evenly distribute
da University, Loma Linda, and the Delta Eye Medical Group
the weight of the AC IOL on the iris. A 10-0 polypro-
(Narvaez), Stockton, California, USA.
pylene suture on a long needle is entered through the
Presented in part as videos at the XXX Congress of the European superior paracentesis to perforate the iris anteriorly
Society of Cataract and Refractive Surgery, Milan, Italy, September with the needle directed around the nasal optichaptic
2012, and at the ASCRS Symposium on Cataract, IOL and Refrac- junction. Subsequently, the iris is perforated again pos-
tive Surgery, Chicago, Illinois, USA, April 2012. teriorly before exiting out to the limbus inferonasally. A
Corresponding author: Julio Narvaez, MD, 1617 Saint Marks spatula is used to support the iris while the needle is
Plaza, Suite D, Stockton, California 95207, USA. E-mail: passed to facilitate penetration. A modified locking
narvaezjd@gmail.com. Siepser knot is used to secure the haptic to the iris.

Q 2016 ASCRS and ESCRS http://dx.doi.org/10.1016/j.jcrs.2016.06.023 961


Published by Elsevier Inc. 0886-3350
962 TECHNIQUE: IRIS FIXATION OF UNSTABLE AC IOL

Figure 1. Iris-fixation of an unstable flexible open-loop AC IOL. Figure 2. Iris-fixation of an unstable flexible open-loop AC IOL.

The sutures are cut using intraocular scissors. The tem- and cause endothelial damage, iritis, peripheral ante-
poral optichaptic junction is sutured in the same rior synechiae, and glaucoma.9
manner with the exception of using the inferotemporal The surgical management of an unstable AC IOL
paracentesis sites. The anterior chamber OVD is finally typically involves exchange of the IOL. Recently, iris
thoroughly irrigated out of the anterior chamber with a fixation of unstable AC IOLs has been published.8
balanced salt solution (Figures 1 and 2). This method offers a less traumatic solution than an
IOL exchange using a 4-point fixation technique of
RESULTS the AC IOL haptics to the iris. In 2009, one of the au-
thors (J.N.) independently conceptualized and imple-
We have used this technique in 2 eyes of 2 patients, suc-
mented a technique of AC IOL iris fixation that only
cessfully resolving AC IOL rotation and pseudophaco-
requires a 2-point fixation, securing the mobile IOL
donesis. We encountered no complications during
by suturing the AC IOL at the optichaptic junctions.
follow-up, as has been the case with a previous larger
This technique is more efficient than 4-point fixation
series of AC IOLs fixated to the iris.8 Video 1 (available
by reducing in half the number of intraocular knots
at http://jcrsjournal.org) shows the surgical technique.
required for fixation. Although we have no experience
with 4-point fixation, our technique also appears
DISCUSSION simpler to perform because first the suture is passed
The modern flexible open-loop AC IOL and advances more centrally in the cornea, where the anterior cham-
in surgical technique have reduced the incidence of ber is deeper and there is more room to maneuver. Sec-
complications requiring IOL repositioning, exchange, ond, the orientation during the needle pass (Figure 3,
or removal.9 A comprehensive review of the literature broken vertical line) around the optichaptic junction
by Wagoner et al.3 showed that open-loop AC IOLs appears to be more ergonomic because it allows the
are not susceptible to the high rates of corneal endothe- needle as it enters and exits the iris more space than
lial decompensation, secondary glaucoma, and CME would be the case in 4-point fixation, where the exiting
associated with the older generation of closed-loop needle must make a sharp upward turn to be able to
AC IOLs. In addition, they found insufficient evidence clear the peripheral haptic in an area with diminished
of the superiority of 1 IOL type or fixation site when anterior chamber depth (Figure 3, broken horizontal
comparing open-loop AC IOLs with scleral or iris- line).
sutured PC IOLs for the correction of aphakia in eyes Most IOL suture fixation techniques use 1 suture per
without adequate capsule support. haptic. When properly performed, these 2-point fixa-
The advantages of AC IOLs are that implantation is tion techniques have shown long-term effectiveness.
less complex than scleral-wall fixation. The disadvan- We have observed no tilting or pseudophacodonesis
tages are that they are not recommended if the corneal in our patients who have had 2-point fixation and
endothelium or angle structures are compromised. In anticipate this stability to continue.
addition, inaccurate sizing of the AC IOL can lead to After the suturing procedure, the anteriorly vaulted
complications. An oversized AC IOL can cause exces- AC IOL is pulled back toward the iris and each of the 2
sive pressure on the iris root and angle recess, leading haptics end up pressing evenly against the anterior
to pupil ovalization, iris atrophy, hemorrhage, and surface of the iris, effectively distributing pressure at
iritis.9 An undersized AC IOL might become mobile the entire area of irishaptic touch. This prevents

J CATARACT REFRACT SURG - VOL 42, JULY 2016


TECHNIQUE: IRIS FIXATION OF UNSTABLE AC IOL 963

haptic to iris fixation. Condon et al.15 suggest that the


Siepser knot allows the suture ends to be pulled in oppo-
site directions, which allows more precise knot
tensioning and locking. In their study of 46 eyes with
iris fixation of the PC IOL using the Siepser knot, there
were no cases of haptic slippage. The modification of
the Siepser knot by Osher et al.7 results in a true locking
knot and might promote more secure long-term fixation.
In conclusion, 2-point iris fixation of the unstable
open-loop AC IOL using the modified Siepser knot ap-
pears to be an effective, simpler, and less traumatic
alternative to IOL exchange or 4-point iris fixation.

WHAT WAS KNOWN


 Patients with unstable AC IOLs can be treated with IOL ex-
change or 4-point iris fixation.

Figure 3. Diagram of suture passes with 2-point (left vertical hatched WHAT THIS PAPER ADDS
line) and 4-point fixation (right horizontal hatched line).  Two-point iris fixation is a simpler and less traumatic
treatment option in patients with unstable AC IOLs.
tilting, rotation, and pseudophacodonesis. Moreover,
because the AC IOL in this situation is smaller than
usual, fixation to the iris effectively suspends the IOL
away from angle structures, further protecting the
REFERENCES
endothelium and delicate angle structures.
1. Auffarth GU, Wesendahl TA, Brown SJ, Apple DJ. Are there
Potential complications that might arise from iris fix- acceptable anterior chamber intraocular lenses for clinical use
ation of an AC IOL can be inferred from studies of iris- in the 1990s? An analysis of 4104 explanted anterior chamber
fixated PC IOLs. Complications include iris chafing, intraocular lenses. Ophthalmology 1994; 101:19131922
pigment dispersion, chronic inflammation and progres- 2. Smith PW, Wong SK, Stark WJ, Gottsch JD, Terry AC,
sive peripheral anterior synechiae formation, suture Bonham RD. Complications of semiflexible, closed-loop anterior
chamber intraocular lenses. Arch Ophthalmol 1987; 105:5257
breakage, untying of the knot, slippage of the haptic 3. Wagoner MD, Cox TA, Ariyasu RG, Jacobs DS, Karp CL. Intra-
from the suture, and degradation of the suture itself.10 ocular lens implantation in the absence of capsular support; a
Price et al.11 report 5 cases of late breakage of polypro- report by the American Academy of Ophthalmology (Ophthalmic
pylene sutures used for iris fixation of poly(methyl Technology Assessment). Ophthalmology 2003; 110:840859
methacrylate) IOLs using the positioning hole of the op- 4. Drolsum L. Long-term follow-up of secondary flexible, open loop,
anterior chamber intraocular lenses. J Cataract Refract Surg
tic. Examination of all 5 sutures found that the suture 2003; 29:498503
breakage occurred at the site where the suture came in 5. Donaldson KE, Gorscak JJ, Budenz DL, Feuer WJ, Benz MS,
contact with the positioning hole. Parekh et al.12 used Forster RK. Anterior chamber and sutured posterior chamber
a technique of suturing the PC IOL haptics to the iris intraocular lenses in eyes with poor capsular support.
not using a positioning hole with no cases of subluxation J Cataract Refract Surg 2005; 31:903909
6. Kim SS, Smiddy WE, Feuer W, Shi W. Management of dislo-
from suture breakage in more than 100 cases over cated intraocular lenses. Ophthalmology 2008; 115:16991704
7 years. Anterior chamber IOL suture fixation to the iris 7. Osher RH, Snyder ME, Cionni RJ. Modification of the Siepser slip-
through the smooth, round optichaptic junction likely knot technique. J Cataract Refract Surg 2005; 31:10981100
offers some protection against late suture breakage. 8. Belkin A, Ofir S, Kleinmann G, Assia E, Segev F. Iris fixation of
In addition to suture location, the suturing technique unstable anterior chamber intraocular lenses. Cornea 2015;
34:15731576
plays a role in long-term stability. Stutzman and Stark13 9. Jin GJC, Crandall AS, Jones JJ. Changing indications for and
used McCannel sutures to fixate the PC IOL to the iris in improving outcomes of intraocular lens exchange. Am J Oph-
7 eyes, and 1 case of haptic dislocation occurred. Kaiura thalmol 2005; 140:688694
et al.14 also used a simple McCannel suture for iris- 10. Chu MW, Font RL, Koch DD. Visual results and complications
following posterior iris-fixated posterior chamber lenses at pene-
fixation of PC IOLs and reported 3 cases of postoperative
trating keratoplasty. Ophthalmic Surg 1992; 23:608613
IOL slippage. More recently, Condon et al.15 and 11. Price FW Jr, Whitson WE, Collins K, Johns S. Changing trends
Chang16 reported the incorporation of the Siepser sliding in explanted intraocular lenses: a single center study. J Cataract
knot with more favorable long-term results of secure Refract Surg 1992; 18:470474

J CATARACT REFRACT SURG - VOL 42, JULY 2016


964 TECHNIQUE: IRIS FIXATION OF UNSTABLE AC IOL

12. Parekh P, Green WR, Stark WJ, Akpek EK. Subluxation of 16. Chang DF. Siepser slipknot for McCannel iris-suture fixation of
suture-fixated posterior chamber intraocular lenses; a clinico- subluxated intraocular lenses. J Cataract Refract Surg 2004;
pathologic study. Ophthalmology 2007; 114:232237 30:11701176
13. Stutzman RD, Stark WJ. Surgical technique for suture fixation of
an acrylic intraocular lens in the absence of capsule support.
J Cataract Refract Surg 2003; 29:16581662
First author:
14. Kaiura TL, Seedor JA, Koplin RS, Rhee MK, Ritterband DC.
Complications arising from iris-fixated posterior chamber intra- Julio Narvaez, MD
ocular lenses. J Cataract Refract Surg 2005; 31:24202422 Department of Ophthalmology, Loma
15. Condon GP, Masket S, Kranemann C, Crandall AS, Linda University, Loma Linda,
Ahmed K II. Small-incision iris fixation of foldable intraocular
California, USA
lenses in the absence of capsule support. Ophthalmology
2007; 114:13111318

J CATARACT REFRACT SURG - VOL 42, JULY 2016

Vous aimerez peut-être aussi