Dull grey coatings usually occur on steels - or at welds - Lumpiness, Runs and Spikes
with higher silicon content A perfectly smooth hot dip galvanized finish is
WHY GALVANIZE WITH unattainable; in practice lumps and runs from
INDUSTRIAL Bare Spots uneven drainage are not detrimental to coat-
GALVANIZERS? Bare spots have a number of causes but small, ing life. Zinc drainage spikes should be re-
localized flaws up to ~3mm wide tend to be self moved from galvanized articles where they
For steel users requiring present a danger in handling or use.
-healing because of the cathodic protection
fast, proven corrosion provided by galvanized coatings. Larger bare
protection for local or areas (0.1% / 250cm2 of total area or individual
national projects, Industrial areas >40cm2) should be repaired per the
Australian Standard.
Galvanizers is the
Ash Staining
established hot dip
Zinc ash forms in the galvanizing process as
galvanizer with nationwide work is immersed in the zinc. It is skimmed off
coverage. the surface of the molted zinc before the work
is withdrawn. Sometimes ash is trapped inside
inaccessible areas or sticks to the outside of
Drainage spikes formed when molten zinc freezes should
the coating, where it may leave a dull surface be removed by the galvanizer during dressing and
of light brown stain after removal by brushing. inspection.