TECTYL 506

Description

TECTYL 506 is a solvent cutback, wax base, corrosion Protection of metallic surfaces against corrosion in
preventive compound. The dry film is firm, amber, waxy either indoor or outdoor exposure and during
and translucent. TECTYL 506 is excellent for long term domestic and international shipments.
Laboratory Data
Typical Properties

English Metric
Flash, PMCC, Minimum 100 38
Specific Gravity @ 60(15.6) 0.88 0.88
Recommended Dry Film Thickness 1.3 mils 32.5 microns
Theoretical Coverage 630 sq. ft./ 15.4 sq. meters/
U.S gallon liter
Non Volatile % by Weight 53-57 -
Approximate Air Dry Time @ 77(25) 1hour 1hour
High Temperature Flow Point, Minimum 300 150
Low Temperature Flexibility,
(90Bend-No flaking or cracking) -10 -23
Volatile Organic Content (VOC) 3.24lbs./ 400 grams/
U.S gallon liter

Accelerated Corrosion Tests:

5% Salt Spray (Hours)


(A) *ASTM B-117 @ 1.3 mils,
(241/8 in. Polished Steel Panels) 2000 -
(B) **DIN 50021 @ 32.5 microns,
(125200mm. DIN 1623 Panels) - 168

**ASTM (American Society for Testing and Materials)

* DIN (Deutsche Industrie Normen)

Benefits
Easy Application Low Cost Protection
TECTYL 506 is formulated for easy TECTYL 506 is a one-coat rust preventive.
application by spray, dip or brush. The thin film provides high coverage and
low cost protection.

Long Term Protection Removal


TECTYL 506 provides outstanding external TECTYL 506 can be removed with
protection of machinery, machinery, machine mineral spirits or any similar petroleum
rolls, machine tools, automotive parts, dies, solvent, vapor degreasing. TECTYL 506
tubing, and spare parts. TECTYL 506 has a can be removed from fabrics by normal dry
dielectric (insulating) strength of cleaning procedures. Avoid using
approximately 1000 volts per dry mil of film chlorinated or highly aromatic solvents
thickness and therefore protects electrical when removing from painted surfaces as
connections and helps prevent galvanic these solvent may adversely affect paint.
corrosion.
Caution: Combustible
Surface Preparation TECTYL 506 cures by solvent
The maximum performance of TECTYL evaporation. Keep away from heat, sparks
506 can only be achieved when the metal and open flames. Use with adequate
surfaces, to be protected, are clean and dry. ventilation. If applied to the interior of an
Remove dirt, rust, scaling paint and other enclosed vessel adequate ventilation is
contaminants before applying 506. required for cure and to ensure against
formation of an explosive atmosphere. For
Application further information, consult Valvoline
Ensure Uniform consistency prior to use. Cummins Ltd. Refer to Valvoline Cummins
Continuous stirring or thinning is generally Ltd Material Safety Data Sheet for health
not required. If product thickens due to cold and safety instructions.
storage or loss of solvent during use, add
only aliphatic mineral spirits and only if Examples of Application
necessary to restore consistency. Do not Bombardier. Chrysler. Ford. HUNDAI Heavy
apply heat; fire or explosion may result. Industry.
Apply at 50-95(10-35) by spray, dip or DOOSAN Heavy Industry.
brush.

Coverage
The theoretical coverage is 630 sq.
ft./gallon(15.4
sq. meters/liter) at the recommended dry film
thickness of 1.3 mils (32.5 microns). Material
losses during application will vary and must
be considered when estimating job
requirements.

CAUTION: The data, statements WARRANTY: Valvoline Cummins Ltd warrants all products manufactured by it to be free from
and recommendations set forth in this defects in material and workmanship. VALVOLINE CUMMINS LTD MAKE NO OTHER
product information sheet are based WARRANTIES, WHETHER, EXPRESSED OR IMPLIED, WITH RESPECT TO SUCH
on testing, research and other RPODUCTS, AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT
development work which has been NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
carefully conducted by us, and we PARTICULAR PURPOSE AND IMPLIED WARRANTIES ARISING FROM A COURSE OF
believe such data, statements and DEALING OR USAGE OF TRADE, ARE DISCLAIMED BY VALVOLINE CUMMINS LTD. All
recommendations will serve as claims hereunder must be made in writing within 30 days after receipt of the products at the
reliable guidelines. However, this buyers plant and prior to further processing the products or combining them with other materials or
product is subject to numerable uses products. Valvoline Cummins Ltd liability, whether under this warranty or in contract, tort,
under varying conditions over which negligence or otherwise, is limited to the return of the net purchase price paid for any products
we have no control, and accordingly, proven defective or, at Valvoline Cummins Ltd option, to the repair or replacement of said
we do NOT warrant that this product products upon their return, transportation prepaid, to Valvoline Cummins Ltd. THE REMEDY
is suitable for any particular use. HEREBY PROVIDED SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF THE BUYER, AND
Users are advised to test the product UNDER NO CIRCUMSTANCES SHALL VALVOLINE CUMMINS LTD BE LIABLE FOR
in advance to make certain it is CONSEQUENTIAL OR INCIDENTAL DAMAGES, No Valvoline Cummins Ltd representative or
suitable for their particular production other person is authorized to change this warranty in any way or to assume for Valvoline Cummins
conditions and particular use or uses. Ltd any other liability in connection with the sale or use of its products.

REFER TO MATERIAL SAFETY DATA SHEET FOR HEALTH AND SAFETY INFORMATION