COMBINED FOUNDATION DESIGN - CF1

concrete grade N/MM2 30


steel grade N/MM2 500
Gross bearing cpacity KN /m2 156
size of col c1 mm 1000 1200
size of col c2 mm 380 600
load P1 KN 3120
load P2 KN 3050
span of loads (L) m 4.3
CG of load in x from P1 m 2.13
Area of footing required m2 43.51
width of footing (provided) M 5
length of footing (req.) m 8.7
provide, length of footing m 9.5
L1 M 2.60
L2 M 2.10
CG of Load & CG of foundation are coincides
Net upward pressure kn/m2 129.89
SF at left of C1 N 1688.6316
SF at right of C1 N 1431.3684
SF at right of C2 N 1363.8947
SF at left of C2 N 1686.1053
x distance of Zero shear from left edge m 4.8
BM for per meter width
Max. BM at this point KN-m -123.5864
BM at C1 KN-m 439.04421
BM at C2 KN-m 286.41789
Depth req. d = mm 398.84081
Provide, over all depth 900
Effective depth 842
Reinforcement
Left side cantilever Mu/bd^2 0.928914 pt = 0.22
Ast mm2 1852.4
Right side cantilever Mu/bd^2 0.605992 pt = 0.142
Ast mm2 1195.64
between C1 & C2 Mu/bd^2 0.26148 pt = 0.12
Ast mm2 1010.4
Transverse Reinforcement
BM at the face of C1 KN-m 32.473684
Mu/bd^2 0.068707 pt = 0.12
Ast mm2 1010.4

BM at the face of C2 KN-m 43.320707


Mu/bd^2 0.091656 pt = 0.12
Ast mm2 1010.4
Check for shear Tc shall be due to two way action
Tc = 0.25 sqrt(fck) N/sqmm 1.3693064
tc/2 N/sqmm 0.6846532
Left of c1 Tv N/sqmm 0.4011001
Right of c1Tv N/sqmm 0.1953692
Left of c2 Tv N/sqmm 0.4005001
Right of c2Tv N/sqmm 0.3239655
safe in shear

Design of retaining wall /meter run(Prop cantilever)

fck 25
fy 500
Width mm 1000
Thickness of wall mm 230
Height of wall m 4.75

Moment at Base of steam KNm 20 outside


Moment at 2.375m from Base of steam KNm 9.6 inside
Depth of wall =
0.138 X fck x b x d^2 = moment mm 0.0761387
Clear cover = mm 20
R/F dia used = mm 10
Provide Depth of wall at base = mm 230
Effective depth = mm 205
Mu/bd^2 at base 0.4759
Pt 0.11
Ast Required for outerface mm2 225.500
Provide 10 dia of bars @ 150 c/c 523.33333 mm2 outer face

Mu/bd^2 0.2380
Pt 0.106
Ast Required for inner face mm2 217.300
Provide 10 dia of bars @ 150 c/c 523.33333 mm2 inner face

Distribution bars provided 8 dia @200 c/c both face


M 30
Fy 500
SBC 156
1000 1200
380 600
P1 3120
P2 3050
L1 4.3

width 5

length 9.5
L1 2.60
L2 2.10

2947.332

D 900
cover 50
half of dia 16 8
4.6x(Mu/bd^2)/(fck) = 0.142433 fy/fck= 16.66667 0.26148
4.6x(Mu/bd^2)/(fck) = 0.092919 fy/fck= 16.66667
4.6x(Mu/bd^2)/(fck) = 0.129391 fy/fck= 16.66667
Moment at Base of steam 200 KNm
Depth of wall = 230
0.138 X fck x b x d^2 = moment

d = 190.00 mm
Clear cover = 25 mm
R/F dia used = 20 mm
Depth of wall = 225.00 mm
Provide Depth of wall at base = 600 mm
Effective depth = 565 mm
Mu/bd^2 = 0.940
Pt #REF!
Ast #REF! mm2
Required 20 mm dia bars @ #REF! mm c/c
Provide 20 mm dia bars @ 100.000 mm c/c
Distribution steel @ 0.12 % #REF! mm2
Required 12 mm dia bars @ #REF! mm c/c on each face
Provide 12 mm dia bars @ 100.000 mm c/c on each face

outer face
on each face
on each face