STULZ the natural choice

Precise, Reliable and Innovative


Air Conditioning for Information and
Communication Technology
Perfect
Air Conditioning for
Secure ICT Technology

2
Innovative blade constructions, multi-core processors and UMTS are
continuously improving the performance of modern ICT technology.
However, as performance increases so do thermal loads and air con-
ditioning requirements, along with operators concerns about the ope-
rating reliability and availability of their infrastructure. State of the art
precision air conditioning technology from STULZ removes these
concerns, as it provides maximum reliability for your information and
telecommunications equipment.

The entire range can be installed individually

STULZ precision air conditioning units include circulating air systems,


cold water systems and high-density racks. Through their diverse designs
and dimensions, they can provide the perfect customized solution for
your requirements combining flexible use, the ideal configuration and
tried and tested reliability. Find out more and choose precision air condi-
tioning from STULZ.

Circulating air Water


Compact DX and CW CyberCool
MiniSpace
AirBooster High-density
CyberAir CyberChill
Telecom-Line

3
The Perfect Solution for Any Situation
In general, a distinction is made between comfort and precision air conditioning. While comfort
air conditioning creates a pleasant environment for people, precision air conditioning technology
provides reliable cooling that is geared towards the requirements of technical infrastructure.
Dedicated technology rooms in data centres or switching stations require precisely controlled
relative humidity, room temperature, air conduction and air distribution. Precision air conditioning
units from STULZ enable you to create precisely defined climatic conditions with pinpoint
accuracy and outstanding reliability.

Latent or Sensible Cooling Air Distribution, Heat Controlled Temperatures


The sensible part of the Dissipation and Filtration Information and communi-
cooling capacity reduces the Precision air conditioning cation technology only works
temperature, while the latent units from STULZ filter and reliably and without faults
part dehumidifies the air. circulate three times the within a relatively narrow
Comfort air conditioning units amount of air as comfort temperature range.
can use up to 50 % of their units with the same rated
energy for dehumidification, capacity. They reliably dissi- STULZ precision air condi-
whereas precision units con- pate isolated thermal loads tioning units ensure optimum
vert more than 95 % of the even from distant corners of temperature accuracy with
energy used exclusively into the room, while continuously maximum tolerances of
cooling capacity. The tech- monitoring and precisely +/- 1 C, while comfort units
nology required to achieve controlling the temperature can normally deviate from
this pays off quickly in terms and air filtration. the set value by as much as
of lower operating costs. +/- 3 C.

Highly sensible cooling capacity = Optimum air distribution and filtration Precise temperature control
Low operating costs with precision air conditioning

Precision air conditioning unit: Precision air conditioning unit:


Capacity 300 m3/h per kW Precision temperature control

+1 K
24 C
-1 K
1 C t

Comfort air conditioning unit:


Comfort air conditioning unit: Comfort temperature control
Capacity 100 m3/h per kW +3 K

24 C
Precision Comfort
air conditioning unit: air conditioning unit:
05% 4050% -3 K
Air dehumidification Air dehumidification 3 C t

4
Controlled Humidity Excellent Reliability This is why STULZ makes
Unlike comfort air condition- Comfort air conditioning such high demands on the
ing units, precision units units mainly operate in quality of their precision
feature strictly controlled and summer and only for a few air conditioning units and is
accurate dehumidification hours each day. By contrast, able to offer high availability
(tolerance +/- 5% relative precision units need to systems with 99.999% reli-
humidity), as too much humi- be available whenever the ability.
dity can lead to condensation electronic equipment to be
and corrosion, while too cooled is in operation.
little can cause static charges, This is normally the case for
data loss and damage to 24 hours a day, 365 days
hardware. a year.

Precise humidity control Excellent reliability


with 24 hrs/day continuous load

Precision air conditioning unit: Months/year


Controlled dehumidification January
February
March
April
May
June
July
August
September
0h 1h
Precision air conditioning October
(8,760 hrs/year) November
December
Comfort air conditioning unit: Comfort air conditioning
Uncontrolled dehumidification (1,200 hrs/year) 0 12 24 hrs

5
Circulating Air

A Breath of Fresh Air for


Sensitive Technology
Most precision air conditioning systems for IT, telecommuni-
cations and technology rooms are circulating air systems
designed specifically for the individual thermal loads that
occur. The more technology is installed in a room and the
greater the waste heat from the hardware, the more care is
required in planning and designing the air distribution.
STULZ precision air conditioning units enable you to base
your planning on maximum reliability regardless of whether
the performance requirements are simple or complex.

MiniSpace
If you need precise, reliable and economical air conditioning
for small technology and server rooms, the MiniSpace series
provides a space-saving, microprocessor controlled solution.
MiniSpace
Cooling capacity, total kW 523
Cooling capacity, sensible kW 521
Air volume m3/h 2,0007,000

Compact DX and CW
If you need to reliably dissipate heavy thermal loads and keep
an eye on your investments, Compact DX and CW represent a
professional solution based on proven technology.
Compact DX, single and double circuit
Cooling capacity, total kW 17104
Cooling capacity, sensible kW 1789
Air volume m3/h 5,50024,000

Compact CW
Cooling capacity, total kW 12118
Cooling capacity, sensible kW 1196
Air volume m3/h 3,20020,000

Compact DX MiniSpace Compact CW

6
AirBooster
Mounted in the false floor, the AirBooster
conveys up to 1,200 m3/h of cold air directly
to the front of a high-density rack.
This is three times the amount delivered by
conventional ambient air coolers and is
normally sufficient for targeted rack cooling.

AirBooster
Air volume m3/h 1,200
Rated electrical input W 85

7
Circulating Air

CyberAir DX and Dual Fluid Units CyberAir CW Units


Cooling capacity, total kW 18104 Cooling capacity, total kW 30146
Cooling capacity, sensible kW 1889 Cooling capacity, sensible kW 26120
Air volume m3/h 5,20024,000 Air volume m3/h 6,50029,000

CyberAir Low Noise DX and Dual Fluid Units CyberAir CW2 Units
Cooling capacity, total kW 1873 Cooling capacity, total kW 26103
Cooling capacity, sensible kW 1866 Cooling capacity, sensible kW 2489
Air volume m3/h 4,90018,400 Air volume m3/h 7,50026,000

8
Maximum Performance for a
Reliable Infrastructure
With the development of its CyberAir precision air conditioning series, STULZ is setting new
standards in energy efficiency, compact design and serviceability. If you want cutting-edge
air conditioning technology and to cut your operating costs, put your trust in CyberAirs
innovative EC fan technology and new control concepts.

12% Less Space Up To 60% Less Energy


For a cooling capacity of 42 kW, a CyberAir In contrast to conventional technology,
precision air conditioning unit requires an CyberAir precision air conditioning units
installation area of just 1 m2. incorporate state of the art EC fan tech-
nology and feature a free cooling option.
Central Control and This cuts energy costs by up to 60%.
Monitoring of Modular Systems
State of the art control engineering means 5 dB(A) Less Noise
that up to 31 CyberAir precision air condi- Noise-absorbing materials that meet the
tioning units can be combined into a single ko-Tex 100 standard, ingenious fan configu-
network and integrated into central building ration and smooth, optimal air path reduce
services systems. This gives you full control the noise emissions from CyberAir precision
of your air conditioning at all times. air conditioning units by more than 5 dB(A).

9
High-Density

Reliable Dissipation of
Isolated Thermal Loads
Modern server technologies have higher performance but take up less and
less space. This can lead to high thermal loads at isolated points, which are
difficult to eliminate with conventional air conditioning technology. This is
why STULZ CyberChill server racks are directly cooled with water. This enables
thermal loads of up to 35 kW per rack to be reliably dissipated. They can
either be added to existing data centres or utilised as a stand-alone solution.

10
CyberChill Water Cooling, When Air is Not Enough
If the thermal loads in server racks exceed 5 kW, conventional
air conditioning systems cannot deliver sufficient air.
CyberChill uses a recirculation air cooling circuit to cool the
servers, removing the intense local heat load by means of an
air to water exchanger.

11
Water

Cold Water Systems


Efficient and Reliable
Water is the most efficient medium for heat
transfer. This is why water is increasingly
being used to cool technical equipment in
ICT and medical technology. Demand control
concepts and free cooling options ensure
that energy consumption is low. This enables
you to cut your operating costs and reduce
the burden on the environment.

12
CyberCool CSO and CLO Outdoor Chillers: CyberCool Indoor Data Chiller:
Outdoor Installation for Demanding Jobs Cooling Water with Minimal Space
CyberCool Outdoor Chiller units are cold With their compact design, CyberCool Indoor
water systems that use speed controlled fans, Data Chillers produce enough cooling water
timed controllers and low-noise, highly effi- for a cooling capacity of up to 100 kW and
cient scroll compressors to achieve excellent yet require an area of just 0.89 m2. They fit
energy efficiency and quiet operation. through standard doors or and lifts, can be
combined on a modular basis into redundant
An optional controller is available that auto- systems with 99.999 % reliability and can
matically selects Free cooling, Mixed mode be installed in areas of buildings that are sen-
and Compressor cooling, reducing energy sitive to noise.
consumption by up to 40 % compared to
CyberCool Indoor Data Chiller CSI
conventional controllers. Cooling capacity kW 21100

In addition to the CyberCool CSO, the noise


reduced CyberCool CLO design is available. CyberCool Pump&Transfer:
This unit provides the same options but Compact System Separation
operates at a noise level around 10 dB(A) Connecting high-density racks to the central
lower, making it ideal for use in areas that cold water supply requires hydraulic separation
are sensitive to noise. to minimise the water quantity, pressure and
risk of leaks in sensitive IT areas. CyberCool
Pump&Transfer provides this separation and,
CyberCool Outdoor Chiller CSO as a twin circuit system, allows a redundant
Cooling capacity kW 36235 cold water supply to be set up.
CyberCool Outdoor Chiller CLO CyberCool Pump&Transfer
Cooling capacity kW 36157 Cooling capacity kW 20100

CyberCool

CyberCool Pump&Transfer

CyberCool Indoor Data Chiller

13
Circulating Air

Air Conditioning Units for


Telecommunications
Containers, shelters, base stations, distribution centres and switch cabinets for tele-
communications make special demands in terms of air conditioning technology.
The Telecom-Line includes the ideal design for every situation factory tested, filled
with cooling agent and ready to operate immediately.

14
Wall-Air: Wall-Air
Air conditioning unit for outdoor Cooling capacity, total kW 3.820.8
Cooling capacity, sensible kW 3.819.5
wall mounting
Air volume m3/h 1,0005,700
Tel-Air:
Tel-Air
Air conditioning unit for vertical
Cooling capacity, total kW 3.811.1
indoor installation
Cooling capacity, sensible kW 3.810.4
Air volume m3/h 1,0003,000
Split-Air:
Split air conditioning unit for Split-Air
indoor and outdoor installation Cooling capacity, total kW 3.88.4
Cooling capacity, sensible kW 3.87.8
Wind-Air: Air volume m3/h 1,0002,150
Window air conditioning unit for
complete or partial indoor and Wind-Air
outdoor installation Cooling capacity, total kW 3.88.8
Cooling capacity, sensible kW 3.47.8
Mini-Air: Air volume m3/h 1,0002,700
Switch cabinet air conditioning unit
Mini-Air
for vertical indoor installation
Cooling capacity kW 0.83.9
Air volume m3/h 2201,150
Compact-Air:
Switch cabinet air conditioning unit Compact-Air
for vertical outdoor installation Cooling capacity kW 0.83.9
Air volume m3/h 2201,150
X-Line:
Air/air heat exchanger for switch X-Line
cabinets Specific heat transfer W/K 60130

Split-Air Tel-Air

Wall-Air

Compact-Air Mini-Air

X-Line

Wind-Air
Split-Air

15
C1002 C6000 Chiller C7000
Standard controller with 4-digit LCD graphic display High redundance and availability
7-segment LED display Integrated sequencing for up to due to autonomous controllers
Key pad 6 units Integrated sequencing for up to
Integrated sequencing for High pressure management 31 units
connecting two units Free cooling management Zone operation
Continuous condensing pressure Filter control management
C1010 regulation CW standby management
4-line text based LC display Free cooling control
Sequencing for up to 35 units User interface with graphic display
Continuous condensing pressure and remote control (optional)
regulation
Software update and system
configuration using hardware key
(optional)
Separate control unit for remote
control (optional)

16
Intelligent Control and Central Monitoring
of Precision Air Conditioning
STULZs intelligent CompTrol control concepts Interfaces to Building Services and Internet
ensure reliable operation of precision air con- The STULZ MIB7000 (Multifunctional Inter-
ditioning units and cold water systems. Set- face Board) has an integrated sequencing
point entry and adjustment, unit monitoring function for up to 32 units. The RS485/RS232
and operating data output using separate serial interfaces support all standard building
control units, PC or connection to existing services systems. The STULZ WIB7000 (Web
building services systems. This allows you to Interface Board) communicates using the IP
maintain an overview and keep control at protocols SNMP and HTTP.
all times. Configuration and operation are browser-
based. The STULZ LIB7000 (Lon Interface
Board) enables all units to be integrated into
LonWorks technology.

C4000
C5000
C1002 C7000
C1010
C6000

Gateways for STULZ controller systems Data protocol Gateways


SDC C7000 Advanced/MIB7000
Modbus C7000 Advanced/MIB7000
P90 C7000 Advanced/MIB7000

ALARM Remote monitoring SNP C7000 Advanced/MIB7000


and control Network bus C7000 Advanced/MIB7000
Saia bus C7000 Advanced/MIB7000
BACnet MIB7000
Ni bus MIB7000
Display/ LonTalk LIB7000/LIB7000 + MIB7000
SMS visualization
SNMP WIB7000
HTTP WIB7000
N2 bus METASYS
Unigyr bus CFE
E-mail Operation Sinec L2 bus CP524

Alarm/ Remote
ZLT maintenance

HTTP/
SNMP
Customer

17
18
STULZ Expertise and
Partnership Bring
Tailored Solutions
STULZ precision air condition units feature optimum quality and reliability.
From individual units with a cooling capacity from 0.3 kW through to
modular systems with several megawatts of capacity, STULZ offers a com-
plete range of products that provide optimum solutions for every situation.

Air conditioning experts support you in design, realization, installation


and maintenance of your system. In case of emergency, the STULZ service
organisation provides rapid assistance and maximum availability.

Reliable Air Conditioning Available Worldwide

Whether it is in Rio, New York, Shanghai or Tokyo: Operators of ICT sys-


tems throughout the world rely on precision air conditioning technology
from STULZ. Put your trust in STULZ with our 30 years of experience, high
availability quality products, expert advice and reliable service. Wherever
you need us, we are not far away.

www.stulz.com/global

19
STULZ HEADQUARTER
D STULZ GmbH
Holsteiner Chaussee 283 . 22457 Hamburg

STULZ GmbH, Hamburg


Sales Germany, Tel.: +49(40)55 85-306
Sales International, Tel.: +49(40)55 85-269
Fax: +49(40)55 85-308 . products@stulz.de

STULZ SUBSIDIARIES
AUS STULZ AUSTRALIA PTY LTD
Unit 21, 287 Victoria Rd . Rydalmere NSW 2116
Tel.: +61(2)96 38 70 00 . Fax: +61(2)96 38 70 22 . sales@stulz.com.au
E STULZ ESPAA S.A.

09-06 e . IWS . Weidmann


Calle Lluvia N 1 . 28918 Legans (Madrid)
Tel.: +34(91)517 83 20 . Fax: +34(91)517 83 21 . info@stulz.es
F STULZ FRANCE S. A. R. L.
107, Chemin de Ronde . 78290 Croissy-sur-Seine
Tel.: +33(1)34 80 47 70 . Fax: +33(1)34 80 47 79 . info@stulz.fr
GB STULZ U. K. LTD.
First Quarter . Blenheim Rd. . Epsom . Surrey KT 19 9 QN
Tel.: +44(1372)74 96 66 . Fax: +44(1372)73 94 44 . sales@stulz.co.uk
I STULZ S.P.A.
Via Torricelli, 3 . 37067 Valeggio sul Mincio (VR)
Tel.: +39(045)633 16 00 . Fax: +39(045)633 16 35 . info@stulz.it
IN STULZ-CHSPL PVT. LTD.

Technical data subject to changes without notice.


006, Jagruti Industrial Estate . Mogul Lane, Mahim . Mumbai - 400 016
Tel.: +91(22) 56 66 94 46 . Fax: +91(22) 56 66 94 48 . info@stulz.in
NL STULZ GROEP B. V.
Industriecentrum Bovenkerk . Postbus 75 . 1180 AB Amstelveen
Tel.: +31(20)54 51 111 . Fax: +31(20)64 58 764 . stulz@stulz.nl
PL STULZ POLSKA SP. Z O.O.
ul. Wodarzewska 69 . 02 384 Warszawa
Tel.: +48(22)883 30 80 . Fax: +48(22)824 26 78 . info@stulz.pl
USA STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC.
1572 Tilco Drive . Frederick, MD 21704
Tel.: +1(301)620 2033 . Fax: +1(301)662 5487 . info@stulz-ats.com

STULZ the natural choice

Close to you worldwide.


with expert contacts in our STULZ subsidiaries, and our
exclusive global network of sales and service partners. Our
five production plants are in Europe, North America and Asia.

www.stulz.com/global