Vous êtes sur la page 1sur 11

System 800xA

System Introduction
Reaching new levels of productivity System 800xA Extended Automation
with System 800xA

System 800xA Extended Automation was built for integration

Youre under more pressure than ever before to run your System 800xA Extended Automation is an integration System 800xA - The Power of Integration Knowledge management
operation profitably to achieve greater results with platform with unparalleled connectivity to enterprise and plant Removing the barriers of traditional distributed control Powerful knowledge management software collects, stores,
fewer resources. systems, applications, and devices that improves operations, systems, System 800xA provides the integrated environment retrieves and presents current and historical process and
engineering, control and maintenance and provides a that is required to increase productivity while reducing risk business data to support reporting, KPI visualization, and
Extended automation collaborative environment where real-time decision making and total cost of ownership. System 800xA dramatically analysis.
System 800xAs xA stands for Extended Automation and is a reality. This is the Power of Integration. improves plant-wide productivity through the following powerful,
utilizes the Industrial IT architecture which was built for integrated core functions. Batch management
integration in a fully redundant, reliable environment. Support for life 800xA Batch Managements enterprise level planning
ABBs superior lifecycle policies, services and products Operations coordinated with production system scheduling provides the
System 800xA extends the reach of traditional automation ensure the highest possible return over the entire life of 800xA Operations, the industrys most intuitive system agility, speed, and the quality control needed to respond to
systems - beyond control of the process - to increase energy the system. interface, provides a consistent method for accessing increasing production demands. Including ISO S88 S 98.
efficiency, asset utilization, energy savings and operator enterprise-wide data and for interacting with multiple
effectiveness. System 800xA is the latest installment on ABBs 25+ year applications from any connected workstation in the plant Asset optimization
commitment to our DCS users. Our pledge of evolution or office. Asset optimization software exploits the wealth of plant
The power of integration through enhancement ensures that future advances in resident information to monitor, assess, and report equipment
In order to be competitive, various plant entities, departments systems technologies will enhance rather than compromise Engineering conditions in real time to reduce costly corrective and
and personnel have to work as one flexible, integrated, your current investments. System 800xAs integrated engineering environment efficiently preventive maintenance and optimize maintenance and
collaborative team. For this to be accomplished, an supports the complete lifecycle of the automation project, calibration work flows.
automation platform with incredible connectivity capabilities is Where others promote rip and replace migration strategies, from planning, through configuration and library management,
necessary. Integration of systems and applications where all we deliver true system evolution, allowing you to build on your to commissioning and operation to minimize system Control and I/O
actionable information is available for use in the system can strong DCS foundation. ownership costs. Comprehensive suite of standards-based hardware and
be provided to users in a variety of roles. software meets the needs of total plant control. Controllers
Safety are complimented with a full line of industrial I/O interfaces to
A complete, scalable IEC 61508 and IEC 61511 compliant meet all plant environments.
SIS (Safety Instrumented System) that spans the entire
safety loop, including SIL rated field devices, I/O modules, Device management
controllers, and field actuators. Powerful system functions Support of digital fieldbus standards and intelligent device
as well as operator and engineering tools reduce plant risk management provides significant cost savings throughout the
through management of the human factor. design, implementation and operation of field equipment.

2 Extended Automation | System 800xA System 800xA | Extended Automation 3


The Power of Integration Promoting collaboration

System architecture Licensing is done on a system level so all information and Control system integration CI868 CI860

System 800xA delivers the exact information and applications in the system are available at each workplace. System 800xAs integration platform enables controller and CI873
ETHERNET/IP CI871
ELECTRICAL
INTEGRATION CI867
FOUNDATION
FIELDBUS CI854A
CI853
SERIAL AC 800M
(DEVICENET) PROFINET IEC-61850 MODBUS TCP HSE PROFIBUS DP MODBUS CONTROLLER
collaboration environment necessary for the formation and Regulatory compliance functionality is built into System device level integration via OPC and fieldbus protocols. This
execution of sound business decisions. ABBs integration 800xA through its integrated audit trail, user log-over platform provides a foundation for evolution from ABBs
architecture, based on Aspect Object technology, relates all function and electronic batch records. installed based to the latest technology with System 800xA.
of your plant data, the Aspects, to the specific plant assets, System 800xA has been developed and delivered as an The development of system specific control libraries for
the Objects. This architecture enables one click navigation, integrated system. Adding or changing control information System 800xA allows users to easily transfer their control
efficient engineering and presentation of the right information is no problem. Simply engineer the change once and it will code from their existing controller to the newest AC 800M
in the right context to the right user. be automatically deployed through the system. controller saving time and preserving their original engineering
SERIAL FOUNDATION PROFIBUS PA
investment. Connectivity packages provide integration with DEVICENET FIELDBUS H1 VIA LINKING
VIA VIA LINKING DEVICE
The client server architecture of System 800xA is the 800xA Operations bringing all of the extended automation GATEWAY DEVICE

backbone of the system. It is this architecture that provides: Plant system integration and applications features to our installed base. Standards-based fieldbus communications for System 800xA controllers
The integration architecture of System 800xA allows seamless
Centralized licensing integration of applications and supports 3rd party systems The OPC connectivity that is part of System 800xAs
Streamlined controller communications such as computer based maintenance management and integration platform enables connection of 3rd party DCS The powerful integration of so many fieldbus options provides
Centralized configuration and backup video systems. As shown in the diagram at the bottom of this controllers and PLCs. Once connected, the data becomes all of the necessary information needed for an optimized
High level alarm handling page, applications developed with or for System 800xA can part of the system in the same way as other integrated ABB control application directly to that application. Especially with
System wide trend, history and audit trail data collection, be plugged into the common engineering, information and hardware and software components. the ethernet-based communications like FF HSE, Ethernet/IP,
storage and viewing visualization environment. Modbus/TCP, PROFINET, and IEC-61850, the wide-reaching
Device integration network infrastructure supported by these protocols allows
System 800xA also provides hardware freedom of choice This same architecture enables us to deliver solutions such as System 800xA is designed to be the best system at individual controllers to see information from nearly anywhere
when it comes to the server / workstation computer hardware. integrated process control and safety and integrated process integrating fieldbus solutions. Each AC 800M controller can on the entire network. There is no longer a need for individual
Virtualization can be used in 800xA systems to combine and power automation solutions. Both these and many mix and match incoming information from any combination controller-dedicated I/O structures. System 800xA is uniquely
multiple 800xA applications into a single server with pre- other System 800xA solutions feature common visualization of up to 12 direct fieldbuses. Supporting fieldbuses delivers positioned to deliver the values associated with fieldbus
tested, validated architectures using VMware ESX. System across plant areas and deliver savings in engineering as well significant value to the end users in the form of both solutions no matter which protocol you choose.
800xA also has a wide variety of certified and approved facilitating the right operational and business decisions and CAPEX savings (wiring, footprint, weight) and OPEX savings
servers in both standard and blade configuration. actions to maximize productivity. (asset management, heating & cooling, design flexibility,
maintenance strategy).

Information integration
Information collected from the plant applications, business
systems and devices in the System 800xA information
architecture can be used to achieve real improvements in
productivity.

Engineering is done on a system level and provides


significant time savings since configuration of each tag
or object is done only once.
Personalize workplaces can be configured so that each
user has only the information necessary for their function.

4 Extended Automation | System 800xA System 800xA | Extended Automation 5


The Power of Integration Promoting collaboration

Flexible and scalable SIS design Process and power automation Is process automation and electrical integration for me?
System 800xA offers a complete SIS Process automation and electrical integration is the next Different industries have different objectives for electrical
(Safety Instrumented System) solution, frontier in delivering a unified environment that will drive integration. The oil and gas industry wants to maximize
complying with the IEC 61508 and IEC improvements in productivity, increase safety, and reduce production by keeping the process running. Load shedding
61511 standards and covering not only costs. With the growing number of complex plant system during power interruptions is critical. Pulp and paper, steel,
the logic solver but the entire safety interfaces and fewer employees to maintain such systems, aluminum, and cruise ship industries consume large quantities of
loop, consisting of SIL rated field a need for one system to serve both process automation energy. They need to manage electricity as a raw material cost
instruments, controllers and I/O mod and electrical applications has arisen. The next generation through peak shaving and power consumption prediction. All
ules, valve positioners, and actuators. of plant operators will no longer make decisions based only industries are looking for ways to lower installation, engineering,
Highly scalable, System 800xA SIS TV Product Service, on voltages and temperatures but on dollars and cents. and lifecycle costs with simpler more efficient system designs.
solutions provide you the flexibility to the foremost For example, Shell Oil has realized a 20% productivity
independent
match specific safety functions with improvement through improved operator visibility of entire System 800xA and IEC 61850 communications
certification agency
your actual plant needs. in the business, has plant assets. Only ABB can deliver the power of one fully There is a distinct advantage when using System 800xA with
certified all product integrated control system. the IEC 61850 integration. System 800xAs AC 800M controller
800xA High Integrity controllers and components of the is transformed into an Intelligent Electrical Device (IED). As an
800xA Safety offering.
I/O are highly modular, offering many Electrical integration and the process control industry IED, the AC 800M communicates horizontally with other IECs
interconnection options and making Typical process control plants can be divided into three using the GOOSE protocol for the fast time-critical data.
them suitable for all safety and business critical process areas: Process Control, Process Electrification, and Power
automation applications, from small to large, from single to Distribution and Management. In the past, each of the Benefits of integration
redundant. Redundant solutions for CPU and I/O will increase areas has been handled by separate systems with unique The benefits of process and power automation integration
the availability without increasing the probability of failure on communication protocols. Today, ABB seamlessly integrates include:
Today, companies require tighter integration among safety demand (PFD) as happens with other systems. the three areas to make their information available to all other
and control applications. The industry is calling for SIS system functions. ABB has created a solution with System Single system that promotes collaboration and operator
solutions that are cost effective through integration with SIL compliant application solutions 800xA that integrates electrical control with process control effectiveness
control systems, require less frequent proof-testing, System 800xA includes a comprehensive library of standard within a plant by taking advantage of the IEC 61850 standard. Total plant visualization through a single controller and HMI
and provide scalable architectures. The 800xA HI (High reusable components that include extended automation for DCS and ECS
Integrity) system satisfies these objectives by providing a entities such as faceplates, graphic elements, trends, Common supplier of automation and electrification needs
functional building block approach for system design to document links, and alarm and events. In addition, ABB Consistent strategy for asset management
meet every system application need. provides a broad family of industry specific libraries that Enhanced visibility into power consumption
contain pre-configured control modules, function blocks,
Embedded safety and control and graphic elements. These pre-tested proven libraries ABBs unified approach combines process control, process electrification and power management
The 800xA system architecture offers the flexibility of hosting significantly reduce the time required to engineer, test, and
both safety and process critical control applications in the maintain control applicat ions, while minimizing project risks.
same controller. The AC 800M HI controller is supported by
common engineering tools, human system interface, historian, ABB safety expertise
audit trail, asset and device management applications, and With more than 35 years of experience in designing,
ins truments; thereby improving the overall integrity and implementing, and maint aining safety systems, ABB provides
reliability of Basic Process Control Systems (BPCS) and a wide range of field proven applications, including:
Safety Instrumented Systems (SIS) operations. Such an Fire & gas systems
environment offers safe, instant, interaction between Emergency and Process shutdown (ESD and PSD)
applications; leading to a host of benefits, from easier Interlock systems
handling, through better technical solutions, to lower costs. Burner Management and Boiler Protection (BMS)
Critical control
Meets industry standards High Pressure Protection Systems (HIPPS)
800xA HI systems are delivered and supported in accordance Pipeline Protection systems (PPS)
with the strictest current standards. Among others, System
800xA HI complies with IEC 61508, IEC 61511, EN 954,
NFPA 85 and NFPA 72 standards.

6 Extended Automation | System 800xA System 800xA | Extended Automation 7


Improving operator effectiveness through integrated information

System 800xA provides a unified, collaborative environment Comprehensive operator functionality for reliable control
for operations that helps our customers increase operator System 800xA provides a complete set of operator functions
effectiveness, and therefore production performance. This that include realistic process graphics based on Windows
includes providing truly integrated operator environment for WPF with standard faceplates, superior trending capabilities,
process, safety and electrical applications, advanced alarm intelligent alarm and event handling, production reporting
management, personalized workplaces allowing for the and remote messaging. Complete functionality simplifies and
ultimate in intuitive navigation and information access. streamlines operator interaction for more reliable control.

Personalized workplaces for focused information access Integrated information for informed decision-making
Workplace layouts are adjusted and optimized to users Unique to System 800xA is its ability to gather information
preferences and needs with individualized menus, toolbar from multiple plant sources and transform it into relevant
contents and display locations. Windows management information for a diverse set of users such as maintenance
functions such as safe areas, pinning and stacking priorities technicians, process engineers, production managers, or
minimize operation errors by prioritizing the presentation of plant operators. Information from ABB applications, other
important material. automation systems or even business systems is readily
System 800xAs Extended Operator Workplace enables operator effectiveness integrated into the 800xA system on common displays. This
single window provides users a much broader view of the
Integrated operations High performance design facility and better information from which to make quicker,
One of the four main components of operator effectiveness The integration platform and leading edge operator more informed decisions.
is integrated operations. The goal of an integrated solution environment are only part of the solution. The real value Integrated environment increases operator effectiveness
operator interface is to provide the operator with a quick, comes from the design and implementation of customized
easy to use and effective decision support environment operations environments taking best practices, ergonomics
for analyzing and troubleshooting both routine and upset and human factors into consideration. System 800xA itself
conditions. This makes the operators much more effective. provides the ability to customize the look and feel of the
operator environment (personalized workplaces) to match
Integrated operations support other end user requirements the operations philosophy. The architecture of System
such as centralized, consolidated operations and multi- 800xA enables intuitive navigation for quick display access.
system integration. Using the System 800xA information Implementation of standards in the areas of display design
architecture, data from multiple sources, from across the (ASM, ISA S88), alarm management and abnormal situation
plant to the enterprise system, can be consolidated into one management enables operators to perform effectively no
common picture of the operation. The seamless presentation matter what is happening in the plant.
of data from multiple sources, placed into context, enables an
operator to do much more than in the past. Just one example Operator competency
of the power of integration. With the technology, human factors and design all being
addressed, the final pillar of operator effectiveness is
Attention to human factors competency. In order to ensure that the operator performs
Once the aggregated information is available within the as expected, it is necessary to provide continuous training
control environment, the next step is to consider the effects through every step of the systems lifecycle. An integrated
and advantages of human factors on operator performance. system not only supports simulated training, but provides a
System 800xA provides the foundation for optimal platform for modification and optimization studies as well as
presentation of information to the operator. But what about knowledge capture.
the physical environment? This is where the human factors
should be considered. This includes things such as: With a training technology platform identical to the plant
control system, you will be able to provide realistic and
Advanced keyboards for multi-client handling with hotkeys efficient training of process operators and instill confidence
Directional sound system and integrated dimmable lighting that they know how to respond correctly with abnormal
Motorized, adjustable monitoring positions situations arise.
Pre-integrated operator desk system with adjustable desk/
monitor positioning With competent operators, working on an integrated
Micro-ventilation and other leading edge innovations system, in an optimally designed environment, true operator
effectiveness can be achieved through the power of
All of which are available through the System 800xA Extended integration.
Operator Workplace and the power of integration.

8 Extended Automation | System 800xA System 800xA | Extended Automation 9


Generating cost effective solutions through integrated engineering tools

Device management
Device management for HART, FOUNDATION Fieldbus,
and PROFIBUS intelligent devices provides the tools to
engineer device integration from topology on down to the
field elements, including device parameterization, application
planning, commissioning, and detailed diagnostics.

Bulk data management


The ability to efficiently manage large amounts of data is
crucial to the engineering of any automation system. Using
Microsoft Excel and Excel add-ins, 800xA Engineering bulk
data management features allow for the automatic importation
and assignment of external data such as signal lists, tag
names, or documents. In addition, you can export system
data at any time to support data validation and modification.
System 800xA Windows Presentation Foundation (WPF) graphics
Reusable solutions streamline engineering
System 800xA provides a visual environment for easy achievable from reduced as-built cycles and by automatically Companies ensure maximum consistency, reliability, and
design and deployment of automation strategies, process maintaining design synchronization. availability of plant asset production by using Best Practices Change management
visualization displays, information management, asset solutions. System 800xA allows standard solutions to be Needed to meet regulatory compliance, 800xA Engineering
optimization, and field device integration. The flexible, Graphical function design quickly reproduced and deployed. change management features record and track system
distributed engineering environment allows project data 800xA Engineering graphical function design features enable configuration changes to project libraries, instantiated
to be accessed, created and modified simultaneously by your engineers to be engineers instead of programmers. Most focus their reuse solutions at the process control solutions, and runtime and off-line data. System 800xA not
different users. The graphical design of automation strategies facilitates easier strategy and implementation levels. With System 800xA, your only tells the what, why, where, and when of changes that
engineering of your applications. Because design is function solution standards incorporate extended automation entities have occurred, it also improves the granularity of the change
Total asset lifecycle engineering oriented, you can develop strategies without specifying such as faceplates, graphic elements, trends, document links, with a Detailed Difference Report. This report indicates
Opportunities to drive operational performance improvement controller and I/O physical allocations. Computerized Maintenance Management Systems (CMMS) the exact change that was made thereby reducing time for
starts early in the project lifecycle where key asset information data views, field device diagnostics, and asset monitors. verification during traditional change management processes.
is being created in core process design systems. For Process visualization Standards are defined at any level across the entire plant,
example, by using System 800xAs process engineering tool Based on the new Microsoft Windows Presentation loop, machine, line, unit, and area. Integrated documentation and diagnostics
integration for Intergraph SPI, not only can automation system Foundation (WPF) technology, interactive process operation System 800xAs integrated engineering environment provides
structure, functionality, and graphics be created directly from graphics can easily be customized through the use of the As needs change, your standards will change. System 800xA the ability to associate documentation with related equipment
the INtools design, but operational changes such as ranges, comprehensive library of pre-defined elements and symbols. allows you to improve them. And, with automatic update and applications. Using dynamic documents, you can quickly
units, and settings, can be continually reflected back to the In addition, bitmaps, photos, and third party graphical of all deployed instances, you can immediately improve the navigate to the displays required for action. Documents
INtools application. With this unique feature, engineering elements can be supported. performance of your plant. based on Microsoft Excel, Word, AutoCAD and many other
savings of 40% and operational savings of 20% are formats can be enhanced with live process values for easier
diagnostics review.

System enhancement
Planning Design Configuration Installation Commissioning
and support

10 Extended Automation | System 800xA System 800xA | Extended Automation 11


Achieving seamless control through integrated fieldbus communications

Traditionally, production facilities maintained many Vertical device integration Foundation Fieldbus
controller subsystems; each meeting specific plant System 800xA provides device integration through numerous System 800xAs support for Foundation Fieldbus (FF)
needs. However, as business goals have changed, using communications gateways and protocols. This enables includes both HSE and H1 networks. Foundation Fieldbus
a scalable controller platform possessing multi-functional the process and diagnostic data from the field devices offers the unique capability to fully distribute control into the
capabilities, adaptability to changing requirements, (instrumentation, drives, IEDs etc.) to become part of the field devices with the use of function blocks similar to those
openness, and maximum availability, is critical for 800xA system making that data available for all integrated used in most DCSs today. System 800xA is the only DCS
success. The System 800xA family of controllers, applications. There is significant value in having this that offers a full implementation of FF HSE and FF H1 that
communication interfaces and I/O modules match the diagnostic data available real time for an operator trying to provides significant benefits to the user unmatched by a direct
most challenging requirements in all these areas. diagnose a problem. FF H1 only solution. These include:

High performance controller Some of the specific communications modules supported by No controller requirements
System 800xAs flagship controller, the AC 800M, has System 800xA include: Further wiring reductions
the ability to integrate various networks, fieldbuses, Elimination of peer-to-peer data sharing
serial protocols, and I/O. It provides seamless execution IEC 61850 Flexible architectures for FF with robust communications
of advanced and process control strategies as well as IEC 61850 defines interoperable function blocks which Separated control and field device networks for
safety, electrical, quality control, and power management communicate over a network with other functions regardless independent commissioning
applications. on which suppliers device they are implementing. System Virtual signal marshalling concept not tied to individual
800xAs IEC 61860 communications module is a key addition controllers
The latest controller in the AC 800M family is not only to AC 800M communications that enables users to finally Ability to withstand higher noise levels especially for
significantly faster with more memory than earlier models, but optimize the use of their electrical subsystems within a facility communications between H1 links
easier to engineer as well. This provides significant value in System 800xA I/O provides a wide variety of input/output and signal relative to the power utilization required by the process Built for Control in the field without being restricted to
large applications when a centralized approach is required. conditioning capability manufacturing needs in real time. one H1 link

Comprehensive communications protocols Flexible I/O options System 800xA not only provides freedom of choice of fieldbus
Designed from the ground up to leverage the power of System 800xA I/O, available for local and remote mounting, protocol, but of Foundation Fieldbus networks as well.
industry standard fieldbuses and open communication provides a wide variety of input/output, ranging from standard
protocols, System 800xAs open architecture allows for the analog and digital to HART, FOUNDATION Fieldbus H1/ Profibus/Profinet
easy integration of a wide variety of devices and systems. HSE, PROFIBUS PA/DP, PROFINET and IEC 61850 protocol PROFIBUS DP & PA are used for many applications including
This extensive portfolio of modules enables seamless devices. Intrinsically safe I/O, SIL rated I/O, and modular remote I/O with S800 and S900 products, connectivity to PB/
System 800xA supports multiple communication modules
integration of fieldbus devices, traditional technology packaging options allow for System 800xA to be installed PA devices like transmitters and valves, and solutions with AC
controllers from ABB and 3rd parties, as well as electrical anywhere in the plant. These protocols enable integration of & DC drives.
ERP, CMMS...
equipment. Extended automation solutions such as integrated data and devices from almost any compliant source.
process and power automation are now easily engineered and Available in the latest System 800xA release, PROFINET
Base System Extended Operator
deployed and can leverage both the 800xA applications and WirelessHART Servers Panel 800 System Workplaces now provides many of the features of PROFIBUS DP on
Workplace
System Networks
hardware (IEC 61850 communications module). System 800xA enables customers to utilize technologies such an Ethernet backbone using the same tools and seamless
as WirelessHART to more easily capture diagnostic data as connectivity features users of PB/DP & PB/PA already
AC 800M WirelessHART
well as access wireless process variables. System 800xAs Controller Gateway Aknow.
C 800M PROFINET is one of the key networking infrastructure
ABB and
Hi gh I nte gr i ty
integration platform enables users to acquire WirelessHART Cprotocols that users will have to integrate a wide range of
System 800xA supported communication types Field Networks 3rd party
ontrol l e r
PLC & DCS
diagnostic and process data and use it within any System automation networked products and solutions.

MODBUS
Serial communications (CI853) MODBUS TCP (CI867)

PROFIBUS / PROFINET / Modulebus / DeviceNet

PROFIBUS / Foundation Fieldbus / Modulebus


Motor
PROFIBUS DP (CI854A) PROFINET (CI871) 800xA control or monitoring application. Asset optimization Controller S800 I/O
Fire & Gas

Modulebus
FOUNDATION Fieldbus (CI860) IEC 61850 (CI868) features can be used to support advanced maintenance Ethernet IP / Device Net
IEC 61850

Ethernet/IP (CI873) MasterBus 300 (CI855) strategies and improve device performance. Variable
Also in the latest release of System 800xA are Ethernet IP
S100 I/O (CI856) TRIO I/O (CI862) Speed Drive and Device Net communications modules. EtherNet/IP is the
Control IED
Satt I/O (CI865) INSUM (CI857) System 800xAs WirelessHART integration, combined with REG670
TCP/IPShut-down
Ethernet extension of DeviceNet (and ControlNet). In
DriveBus (CI858) ABB Instrumentation WirelessHART adapters and Wireless S900 I/O addition to the speed increases achievable with Ethernet, the
LV Switchgear
consulting services offerings, delivers the complete package protocol also includes standard object and device models to
necessary to help customers implement a solution tailored to simplify the communication message structures. A primary
WirelessHART
their needs. Power Process Process application of EtherNet/IP within System 800xA will be to
Automation Electrification Instrumentation Safetyprovide high speed connections
PLC & DCS to PLCs and Motor Control

Centers (MCCs) that use this protocol.

12 Extended Automation | System 800xA System 800xA | Extended Automation 13


Providing a flexible evolution path through integrated controller platforms

Continuous productivity improvements and increased Expanding functionality Traditional rip and replace upgrades ABB control library for AC 800M upgrades
profitability are the driving forces behind the selection By evolving to System 800xA, the traditional system Re-engineering or translation of control applications Minimal to no engineering required
of todays automation systems. Traditionally, production functionality can now be extended to include asset New algorithms results in new process control behaviors Process control is same as before
facilities maintained many controller subsystems; each optimization, alarm management, and knowledge Long commissioning and startup periods Minimal commissioning and startup
meeting specific plant needs. management capabilities. Certified hardware and applications Create new documentation Documentation converted and enhanced
from ABB and 3rd parties provide additional value for the Results in: Results in:
However, to succeed in todays changing business installed base including Advant Master, Symphony Harmony Greater loss of production Minimal loss of production
environment, you need a controller possessing multi- / INFI 90, Symphony DCI, Freelance, Contronic, and MOD Increased risk Minimal risk
functional capabilities, adaptability to changing requirements, 300 control systems as well as the latest AC 800M series Higher project costs Lower project costs
openness, availability, programmability and maintainability. controllers. Comparison of evolution strategies

Installed base compatibility ABB offers evolution paths for the installed base through its Investment protection Through ABBs evolution strategy, lifecycle policy, software
System 800xA builds upon the leading brands and common HMI (System 800xA Operations), controllers and ABBs automation solutions help sustain and extend your management, and evolution planning programs, our installed
technologies that have made ABB number one in automation I/O subsystems. Controller level peer-to-peer communication control system to meet todays business challenges. We are automation systems remain viable and sustainable.
systems installed base. This includes control and I/O between traditional and AC 800M controllers allows for the focused on keeping your system as vital and productive today
compatibility for most installed systems from ABB, Bailey, incremental evolution and expansion to System 800xA. as it was the day you bought it. This dedication is realized in The power of integration: evolving to System 800xA
Hartmann & Braun, Taylor, Fischer and Porter, and Alfa Laval In addition to its products, ABB has an evolution services a number of ways. ABB has: At the core of System 800xA is its integration platform. It
Automation. The result: maximum leverage from installed division that offers its customers low risk evolution programs is this platform which enables ABB to provide a powerful
components as you evolve to new functionality! to System 800xA including hardware, software, application A defined lifecycle support policy evolution path for its large installed base of control systems
upgrades, modernization and implementation. A history of providing a forward evolution path for all of our to System 800xA Operations. There are significant benefits in
System 800xA supported controllers systems evolving to the latest hardware and software versions if you
AC 800M series AC 870P series Control libraries New technology that seamlessly integrates with and own one of ABBs traditional control systems. However,
Advant Master series MOD 300 series ABB is committed to providing its system owners with enhances our existing systems these benefits extend even further when integrating other
Freelance series Melody series extended automation solutions while protecting the capital Tools and libraries that convert existing graphics, control equipment such as 3rd party controllers and PLCs. Once
Safeguard 400 series SATT & Sattline series equipment and intellectual property investments made code and documentation all areas of a plant / unit are controlled by and visualized
Symphony DCI series Symphony Harmony series in their installed systems. Control libraries are one of the The lowest risk solution for the life of your system within System 800xA, operators will become more effective,
solutions ABB offers for protection of investment in control maintenance and troubleshooting will become easier and
applications. These libraries allow for step-wise evolution collaboration for real-time decision making will become
With the largest installed base of traditional DCSs in the world, ABB has of control configurations to System 800xA using the same Stepwise execution standard good practice.
designed the 800xA system to allow for implementation with its entire line control algorithms as the original system. ABBs evolution strategy is realized through our lifecycle
of control and I/O products
programs ensuring that your control system is always current
and serves your business needs. We are committed to
working with our customers through our evolution planning
and execution process to ensure that you can:

Make informed decisions


Better control lifecycle costs
Extend the life of your existing automation systems
Remove uncertainty to create predictable budgets
Eliminate unplanned upsets and trips due to system
interruption

14 Extended Automation | System 800xA System 800xA | Extended Automation 15


Support for life

In addition, an automation control configuration conversion investments. With this program, system owners can decide Global service
utility transforms the existing control logic diagrams to when to update to newer versions of system software based ABB is one of the worlds largest automation companies with
like diagrams within AC 800Ms graphical engineering on their system lifecycle plan and business objectives. In an extensive, global installed base of control, motion and
environment. Through the use of these libraries and the addition, customers receive consistent support through the robotic products and systems. Our portfolio of services
conversion tools, traditional system owners can evolve their complete lifecycle of their system. from spare parts to consulting, optimization, and outsourcing
control strategies to the latest technology without the project services ensures maximum return on your ABB automation
costs or production risks associated with rip and replace A yearly subscription to the Automation Sentinel program equipment investment. Our automation service offerings
control upgrade methods. provides the following deliverables: include:

Industry leading lifecycle policy Licenses for new versions of system software Asset and process optimization services that utilize proven,
ABBs industry leading lifecycle management programs Software maintenance updates improvement methodology, special tools, and knowledge
assist our customers in actively managing their control Extended support for System 800xA software versions of systems and processes to diagnose, implement, and
system lifecycle costs. Control system lifecycle management up to seven years sustain performance improvement, which lowers cost and
and customer investment protection have always been Technical phone support to assist in system problem increases the productivity of installed systems and assets.
cornerstones of ABBs development programs. ABBs focus troubleshooting Reliability engineering and consulting experts with
on evolution through enhancement has set the industry On-line website access for downloads to assist in system worldwide experience to ensure you reach the full potential
gold standard of lifecycle support for control systems. In maintenance: of productivity and energy efficiency in a sustainable
addition, ABBs system lifecycle policy provides long-term Software updates manner. ABBs broad suite of maintenance and reliability Training services
software version support for up to seven years after release. Firmware updates services assures equipment will start up, operate and shut Product programs
This offers our system owners options to balance the addition User manuals down without failures or cutbacks. Process programs
of new technology and products that increase productivity Software release notes Custom courseware
with the need to mitigate risks and maximize Return-on- Product technical bulletins Lifecycle services include a comprehensive selection of Coaching
Investment (ROI). Software security management: services to maximize productivity, minimize lifecycle costs Training assessments
Microsoft security patch validation status reports and extend the useful life of installed equipment. These
In support of this customer focused strategy, Automation Third party virus scanner qualification include: Engineering and consulting
Sentinel is the system lifecycle management program that Personal computer hardware qualifications for compatible Energy efficiency
extends support for and the value of existing ABB control replacement PC models for new and existing software Maintenance & field services Process safety
systems, protecting our customers system investment. The versions Installation and commissioning Reliability and maintenance
program provides the best overall ROI for past, present and Device library management updates for System 800xA Predictive, preventive and corrective Process optimization
future automation control system software expenditures. for PROFIBUS, FOUNDATION Fieldbus and HART Service contract agreements
Auto notification by e-mail Installation and commissioning
The Automation Sentinel Program assists system owners Technical updates Parts, repair and refurbishment Functional testing and on-site configuration of control
in actively managing their lifecycle system costs and Product release information Parts system components through full process control
Emergency parts commissioning
Test and inspection System placement, power-up, check-out
Repair and refurbishment Control tuning and sensor correlation
Online parts and repair Performance verification and documentation
Parts inventory management

Support and remote services With more than 10,000 service professionals worldwide,
Remote enabled services and diagnostics we get the job done, when its needed, where its needed.
Web-based support
Telephone technical support

Evolution and upgrades


Evolution planning
Evolution implementation
Standard evolution packages

16 Extended Automation | System 800xA System 800xA | Extended Automation 17


Global community of experts

ABBs global community of experts help our end Design and capability consulting Advanced engineering methodologies Asset management implementation solutions
users with competence development, expert training, Reduces future project and operations costs by taking full Accelerates System 800xA engineering competence to Provides assistance in developing and deploying System
and System 800xA consulting in the areas of asset advantage of System 800xA technology during the design enable efficient project implementation 800xAs Asset Optimization in order to reduce maintenance
management, fieldbus technology, system architecture, stages of your project. costs, increase reliability and overall equipment effectiveness.
engineering, information management, and IT security. Achieve greater engineering efficiency with training on
Product capability consulting advanced techniques Asset management strategy and consulting
System 800xA expert offerings System design reviews Field system integration Feasibility studies & pilot projects
Design and capability consulting Fieldbus topology evaluation Project jump start program Fast track device integration
Project risk reduction CMMS integration
Advanced engineering methodologies Project risk reduction Implementation review and advanced troubleshooting
Implementation review and advanced troubleshooting Keeps the project on schedule and under budget to minimize Enables early identification of potential problems to increase
Improvement of operator effectiveness impact on business performance. system reliability and performance.
Asset management implementation solutions
Software solutions Technical project risk assessment Improvement of operator effectiveness
IT security Risk management implementation Improves the operators working environment to support
Fieldbus network design Dedicated project consultant collaborative decision making.

Alarm management strategy and implementation


HMI design review and improvement
Operation strategy implementation
Control room design and improvement

18 Extended Automation | System 800xA System 800xA | Extended Automation 19


Contact us

ABB AB Note:

3BUS095072 en F
Control Technologies We reserve the right to make technical changes
to the products or modify the contents of this
www.abb.com/800xA
document without prior notice. With regard to
www.abb.com/controlsystems
purchase orders, the agreed particulars shall
prevail. ABB does not assume any responsibility
for any errors or incomplete information in this
document.

We reserve all rights to this document and the


items and images it contains. The reproduction,
disclosure to third parties or the use of the content
of this document including parts thereof are
prohibited without ABBs prior written permission.

Copyright 2014 ABB


All rights reserved

800xA is a registered or pending trademark of ABB.


All rights to other trademarks reside with their
respective owners.

Vous aimerez peut-être aussi