Vous êtes sur la page 1sur 1

Atmosph.

Pressure PSV ITEM:


1 bar a Set 0 bar g 58-P-5004A/B

P Operating Elevation
Operating Pressure trays 0 bar Pressure
0 bar g 4.35 bar g 6m Control Valve
HLL 15 m P P's excluding C.V. 0.47 bar 0.57 bar
P line Equipment P FE P C.V. Q normal Q design
T.L. 0.5 m 0.57 bar 0 bar 0 bar 0 bar SUM of: MAX of:
20% P's 0.09 bar 0.06 bar 10% P's
P line 0 bar FE 10%<15, 1.5<30, 5%>30 + 0.22 bar 5% of op. disch. pres.
of static discharge press. 0.49 bar 0.6 bar by calculation from
Equipment
Axe 0.5 m = 4.88 bar P @ Q norm.
0.7 minimum 0.7 bar 0.7 bar 0.7 minimum
P C.V. 0.7 bar 0.7 bar
Density 988.36 kg/m Q norm. 10 m/h Q des. 11 m/h
Suction Pressure: Discharge Pressure:
Operating Pressure 0 bar g PSV Set 0 bar g Operating Pressure 4.35 bar g
T.L. 0.05 bar 0.05 bar Elevation 0.58 bar
Axe -0.05 bar -0.05 bar P Equipment 0 bar
HLL 1.45 bar P C.V. 0 bar
P line 0 bar P trays 0 bar P FE 0 bar
MIN. 0 bar g MAX. 1.45 bar g P line 0.57 bar
5.5 bar g
NPSHA Design Pressure
Min. Oper. Pressure 1 bar a 10.3 m Max. Suction Press. 1.45 bar g
Vapour Pressure 0.12 bar a -1.2 m P x 120 % 6.6 bar To be checked with characteristic curve
9.1 m 8.05 bar g
Suction: P: Max working pres.:
1.45 max. 5.5 norm.
8.05 bar g
1.45 norm. 6.6 max.
i Des. Flow Density Viscosity Velocity P V Eq. Leng. P
line P's
inch kg/h kg/m cP m/s bar/km Pa m bar
Suction 4 10,872 988.36 0.72 0.4 0.14 140 10 0.001
Discharge 3 10,872 988.36 0.72 0.7 0.57 444 1,000 0.566
PUMP POWER (API 610) MINIMUM MOTOR ESTIMATED POWER
EFFICIENCY MECHANICAL MOTOR REQUIRED NOMINAL MOTOR NORMAL
HEAD P ESTI- NORMAL DESIGN OVER- POWER POWER EFFICIENCY ELECTR.
REAL
m bar MATED kW kW DESIGN kW kW AT LOAD kW
56.7 5.5 39 % 39 % 4.1 4.3 25 % 5.4 5.5 85 % 4.8