Vous êtes sur la page 1sur 6

ICRC Pump design 10/20/2017

System Suction Delivery T [c] 50 pump characteristics ac 0.503


Elevation Z [m] 1 20 g [m/s2] 9.81 Pump type: Grundfos SP30-8 cc 19
Pipe length L [m] 100 500 Nu [m2/s] 5.53E-07 Q [l/s] H [m] E(q) aQ^2+bQ+c
Roughness ks [mm] 0.010 0.007 1 0.83 120.0 Ap -0.493 Delta 0.25
Singular losses Kp [-] 5 5 Qest [l/s] 7.702 2 5.56 76.0 Bp -6.155
Diameter D [m] 0.070 0.070 Qest ok 3 8.33 40.0 Cp 125.45

Velocity v [m/s] 2.00 2.00 Q [m3/h] Q [l/s] H pump H system


Losses [m] 5.74 24.09 Characterisitic curves 5.69
6.59
1.58
1.83
114
113
20
21
140
Q [l/s] 7.702 10.19 2.83 104 23
Flow calculated
Q [m3/h] 27.7 120 Pump 11.09 3.08 102 24
Hydraulic power Ph [kW] 3.69 System 11.99
12.89 3.33
3.58 99
97 25
25
Hydraulic profile Distance Head 100 13.79 3.83 95 26
Pipe suction Hasp 0 1.0 14.69 4.08 92 27
Pump suction Hpi 100 -4.7 80 15.59 4.33 90 28
Pump delivery Hpo 100 44.1 H [mCE] 16.49 4.58 87 30
Pipe delivery cal. Href 600 20.0 60 17.39 4.83 84 31
Pipe delivery actual Zd 600 20.0 18.29 5.08 81 32
40
19.19 5.33 79 33
Comment
How to proceed
procder
: :
20.09 5.58 76 35
1) Introduire
Insert suction
les dones
& deliveryd'aspiration
data et de refoulement 20
20.99 5.83 73 36
2) Introduire
Insert 3 points
3 points
for pump
de fonctionnement
performance de la pompe
3) Estimer
Roughlyleevaluate
dbit Q a(Qest)
Q (Qest) 21.89 6.08 70 38
0
4) Cliquer
Click "Adjust"
"Ajuster"if necessary
si ncessaire Q5.00
[l/s] 22.79 6.33 67 39
0.00 1.00 2.00 3.00 4.00 6.00 7.00 8.00 9.00 10.00
5) Corriger
Adjust pipes
les diamtres
to have a de good
conduites
velocity pour avoir une bonne 23.69 6.58 64 41
vitesse
(between(entre
.5 and
0.51.5et 1.5
m/s)m/s)
andet/ou
pumplescharacteristics
charactristiques de la
pompe
to be inpour
the working
tre dans range
la plage de fonctionnement 24.59 6.83 60 42
50.0

Hydraulic profile 25.49 7.08 57 44


H [mCE]

40.0
Warnings: 26.39 7.33 54 46
30.0 27.29 7.58 50 48
28.19 7.83 47 50
20.0 29.09 8.08 44 52
29.99 8.33 40 54
10.0
30.89 8.58 36 56
0.0
0 100 200 300 400 500 600 700

-10.0 Distance

369274369.xls LWI
ICRC Pump design 10/20/2017

Systme Aspiration Refoulement Ajuster Qest Q dsir 8.000


Vitesse v [m/s] 2.08 2.08 Altitude [masl] 2000
Reynolds Re [-] 2.6E+05 2.6E+05 Rognage Ratio de diamtre 100%
Friction fs [-] 0.016 0.016 Rduction vitesse Ratio de vitesse 100%
Pertes. coef. Ktot 28.003 145.462 Kp d l'orifice [-] 28
Etranglement
Pertes [m] 6.17 32.04 rotio d/D (orifice anguleux 50.9% 0.0
Q [l/s] 7.456 Min. atm. pressure [Pa] 75,498
Dbit calcul
Q [m3/h] 26.8 Pressure in orifice [Pa] 557,355
Puissance hydraulique Ph [kW] 3.82 Vapour pressure [Pa] 12,345
Profile hydraulique Distance Hauteur
Conduite apiration Hasp 0 1.0 Rogner Rduire vitesse Etrangler
Pompe aspiration Hpi 100 -5.2 Pour trouver le point de
Pompe refoulement Hpo 100 47.0 To find the duty point,
fonctionnement, en changeant le
by changing the pump
Aprs orifice Ho 100 40.8 or the system:
systme ou la pompe
Conduite refoul. cal. Href 600 15.0
Conduite refoul. rel Zd 600 20.0

50.0 Courbes caractrisitiqu


Profile hydraulique 140

40.0
120
Adjusted Profile
H [mCE]

30.0
Original Profile 100

80

H [mCE]
20.0

60

10.0
40

0.0 20
0 100 200 300 400 500 600 700

369274369.xls 0 LWI
ICRC Pump design 10/20/2017

pump characteristics
Pump type: Grundfos SP30-8
Q [l/s] H [m] P [kW] NPSHr [m] Q [l/s] Eta [m]
1 0.83 120.0 1.5 0.83 20.0% 981
2 5.56 76.0 2.0 5.56 60.0% 5,049
3 8.33 40.0 4.0 8.33 50.0% 6,227

Characterisitic curves
140

120 Pump
System
100

80
H [mCE]

60

40

20

0
0.00 1.00 2.00 3.00 4.00 Q [l/s]
5.00 6.00 7.00 8.00 9.00 10.00

7,000
Power [kW]

6,000

5,000

4,000

3,000

2,000 Power
1,000

-
0.00 1.00 2.00 3.00 4.00 Distance
5.00 6.00 7.00 8.00 9.00 10.00

4
H [m]

2
NPSH
1

0
0.00 1.00 2.00 3.00 4.00 Distance
5.00 6.00 7.00 8.00 9.00 10.00

70%

60%
Eta [-]

50%

40%

30%

20% Efficiency
10%

0%
0.00 1.00 2.00 3.00 4.00 Distance
5.00 6.00 7.00 8.00 9.00 10.00

369274369.xls LWI
ICRC Pump design 10/20/2017

E(q) H system H pump Power NPSH Eta P2


Ap 0.503 -0.493 0.000 0.082 -0.016 -58.0
Bp -6.155 0.000 -0.419 0.187 1230.6
Cp 19 125.45 0.00 1.79 0.06 0.0
Delta 0.25

Q [m3/h] Q [l/s] H system H pump Eta Eta


2.99 0.83 19 120 0 2 20% 981
3.89 1.08 20 118 0 1 24% 1,261
4.79 1.33 20 116 0 1 28% 1,534
5.69 1.58 20 114 0 1 31% 1,800
6.59 1.83 21 113 0 1 34% 2,058
7.49 2.08 21 111 0 1 38% 2,309
8.39 2.33 22 108 0 1 40% 2,553
9.29 2.58 22 106 0 1 43% 2,789
10.19 2.83 23 104 0 1 46% 3,018
11.09 3.08 24 102 0 1 48% 3,240
11.99 3.33 25 99 0 1 50% 3,455
12.89 3.58 25 97 0 1 52% 3,662
13.79 3.83 26 95 0 1 54% 3,863
14.69 4.08 27 92 0 1 55% 4,056
15.59 4.33 28 90 0 2 57% 4,241
16.49 4.58 30 87 0 2 58% 4,420
17.39 4.83 31 84 0 2 59% 4,591
18.29 5.08 32 81 0 2 59% 4,755
19.19 5.33 33 79 0 2 60% 4,912
20.09 5.58 35 76 0 2 60% 5,061
20.99 5.83 36 73 0 2 60% 5,203
21.89 6.08 38 70 0 2 60% 5,338
22.79 6.33 39 67 0 2 60% 5,466
23.69 6.58 41 64 0 3 59% 5,586
24.59 6.83 42 60 0 3 58% 5,700
25.49 7.08 44 57 0 3 58% 5,806
26.39 7.33 46 54 0 3 56% 5,904
27.29 7.58 48 50 0 3 55% 5,996
28.19 7.83 50 47 0 4 54% 6,080
29.09 8.08 52 44 0 4 52% 6,157
29.99 8.33 54 40 0 4 50% 6,227
30.89 8.58 56 36 0 4 48% 6,289

369274369.xls LWI
ICRC Pump design 10/20/2017

Vitesse de rotation [rpm] 1500 Avez-vous chang les caractristique de la pompe (rognage, vitesse spcifiqu 100gpm 200gpm 500gpm 1000gpm 3000gpm 10'00gpm Over 10'000
Nombre d'tage 2 oui flow 12 25 50 120 360 1200 5000
Nombre de volutes 1 non Ns Ns Ns Ns Ns Ns Ns
Nombre de poles 4 Calculer 9.7 0.467 9.7 0.520 12.2 0.649 14.5 0.733 17.6 0.802 20.2 0.845 22.7 0.880
Puissance hydraulique [kW] 3.06 Dbit [m3/h] 30.9 0.545 0.599 0.725 0.780 0.839 0.880 0.902
Rendement de la pompe 50.1% Cavitation Translate 13.6
19.4 0.602
13.6
19.4 0.657
19.4
29.0 0.763
19.5
29.0 0.812
23.2
29.0 0.858
29.0
38.7 0.895
29.0
38.7 0.915
Puissance mcanique [kW] 6.1 NPSH requis 1 29.0 0.646 29.0 0.699 38.7 0.773 38.7 0.823 38.7 0.869 58.1 0.891 58.1 0.915 150 15
Rendement du moteur 85.1% Hauteur de suction max [m] 5.23 35.6 0.657 44.9 0.720 60.8 0.764 58.1 0.816 58.1 0.864 77.5 0.881 77.5 0.908 150 15
Puissance lectrique [kW] 7.2 Coup de blier 85.6 0.793 77.5 0.852 135.6 0.840 135.6 0.872
Facteur de puissance
Puissance active [kVA]
84.1%
8.5
Module de Young [GPa]
Epaisseur de la conduite [mm
Exemple
150
6
135.6 0.804 193.3 0.807
0.769
193.6 0.844
0.806
0.4
1
0.4
1
290.5 290.5
Vitesse spcifique 7.3 Saut de pression [bar] 26.83
Vitesse de l'onde [m/s] 1,381
0 0.4715 0.5969 0 0 0 0
Warning!
Attention!
-Les Thevaleurs
valuesqui
thatsont
arecaclcules
calculated
sur cette
here (especially
feuille (spcialement
the efficiency) Eta4p PF
celles
are only
duanrendement)
approximation ne sont
and Power 4 2 4 2
qu'unedepend
might approximation
on the pumpet peuvent 1 0.7423 0.7545 0.799 0.8415
-dpendre
The specific
de laspeed
pompe only works
- La
if thevitesse
nominal spcifique
point wasne put in 2 0.791 0.805 0.8209 0.8628
fonctionne
the secondquepointsi of
le the
point 5 0.8442 0.8549 0.8387 0.8791
nominal a t curve
characteristic mis comme 2me 10 0.8749 0.8826 0.8473 0.8858
point de la courbe
caractristique de la pompe 20 0.8999 0.9044 0.8529 0.8893
50 0.9278 0.9294 0.8573 0.8923
100 0.9439 0.9446 0.859 0.8939
300 0.9661 0.9664 0.8603 0.8947

369274369.xls LWI
ICRC Pump design 10/20/2017

Qmin Hmin Qnom Hnom Qmax Hmax


Grundfos SP17 /st 0.56 11.12 4.17 8.76 6.11 5.06
Grundfos SP30 /st 0.833333 11.5 5.555556 9.5 8.333333 7.5

369274369.xls LWI

Vous aimerez peut-être aussi