Vous êtes sur la page 1sur 10

DATOS:

t = 1.40 kg/cm2
Ko = 4000 ton/m3
Luz libre = 4.10 m
f'c = 210 kg/cm2
f'y = 4200 kg/cm2
Df = 1.20 m
NPT = 0.25 m
S/C = 400 kg/m2

ELEMENTO CARGAS DE SERVICIO


Columna "Borde" Carga P (ton) M (ton.m)
b = 0.40 m CM 35.00 2.50 P1 (ton) M1 (ton.m)
h = 0.40 m CV 15.00 1.25 50.00 3.75

ELEMENTO CARGAS DE SERVICIO


Columna "Interior" Carga P (ton) M (ton.m)
b = 0.40 m CM 32.00 3.00 P2 (ton) M2 (ton.m)
h = 0.40 m CV 10.00 1.50 42.00 4.50

ELEMENTO CARGAS DE SERVICIO CARGAS AMPLIFICADAS


Columna "Borde" Carga P (ton) M (ton.m) 1.4CM+1.7CV
b = 0.40 m CM 35.00 2.50 Pu1 (ton) Mu1 (ton.m)
h = 0.40 m CV 15.00 1.25 74.50 5.63

ELEMENTO CARGAS DE SERVICIO CARGAS AMPLIFICADAS


Columna "Interior" Carga P (ton) M (ton.m) 1.4CM+1.7CV
b = 0.40 m CM 32.00 3.00 Pu2 (ton) Mu2 (ton.m)
h = 0.40 m CV 10.00 1.50 61.80 6.75

DISEO:

DCL:
74.50 61.80

0.60 3.90
82.79 53.51
DMF: 44.7

0.60 3.90

DFC: 8.29

74.50
PREDIMENSIONAMIENTO EXCENTRICIDAD
n (ton/m2) A (m2) B=1.75L (m) L (m) e (m)
12.70 3.94 2.70 1.50 0.55

EXCENTRICIDAD LUZ ENTRE COL. REACCIN PREDIMENSIONAMIENTO


n (ton/m2) e (m) Lc (m) R2 (ton) A (m2)
12.70 0.60 3.90 36.42 2.87

S AMPLIFICADAS
4CM+1.7CV DIMENSIONES FINALES EXCENTRICIDAD LUZ ENTRE COL.
n (ton/m2) B (m) L (m) e (m) Lc (m)
12.70 3.00 1.70 0.60 3.90

S AMPLIFICADAS
4CM+1.7CV DIMENSIONES FINALES EXCENTRICIDAD LUZ ENTRE COL.
n (ton/m2) B (m) L (m) e (m) Lc (m)
12.70 1.70 1.70 0.60 3.90
DISEO POR FL
DIMENSIONES DATOS NECESARIOS
h (m) b (m) f'c (kg/cm2) fy (kg/cm2) d (m)
0.70 0.40 210 4200 0.62

DISEO POR CORTANTE


DIMENSIONES DATOS NECESARIOS
h (m) b (m) f'c (kg/cm2) fy (kg/cm2) d (m)
0.70 0.40 210 4200 0.62
LUZ ENTRE COL. REACCIN ESFUERZO DEL TERRENO
Lc (m) R1 (ton) t (ton/m2) Verificacin
3.95 54.87 13.55 AUMENTAR DIMENSIONES

PREDIMENSIONAMIENTO ESFUERZO DEL TERRENO


B (m) L (m) t (ton/m2) Verificacin
1.70 1.70 12.60 CUMPLE

REACCIN ESFUERZO LTIMO 1


R1 (ton) ult1 (ton/m2)
82.79 16.23

REACCIN ESFUERZO LTIMO 2


R2 (ton) ult2 (ton/m2)
53.51 18.52
DISEO POR FLEXIN
REFUERZO LONGITUDINAL
As mn As (-) USAR As (+)
5.99

DISEO POR CORTANTE


REFUERZO TRANSVERSAL
Vc (ton) Vc > Vu S (USANDO 3/8") ESTRIBAJE A USAR
16.19 ACERO MNIMO 42.60
NUEVO PREDIMENSIONAMIENTO EXCENTRICIDAD LUZ ENTRE COL.
CONTINUAR >>> B (m) L (m) e (m) Lc (m)
3.00 1.70 0.60 3.90

DIMENSIONES FINALES
CUMPLE! B (m) L (m)
1.70 1.70
USAR
REACCIN ESFUERZO DEL TERRENO DIMENSIONES FINALE
R1 (ton) t (ton/m2) Verificacin CUMPLE! B (m)
55.58 10.90 CUMPLE 3.00
MENSIONES FINALES
L (m)
1.70

Vous aimerez peut-être aussi