Académique Documents
Professionnel Documents
Culture Documents
Risk Assessment
Machine 10 - 38711
Document N 155/2017
Antnio Bastos St, 32 - Cachoeirinha-RS - Phone: (51) 3439.2687 - e-mail: payback@payback.net.br - www.payback.net.br
Scientific Technical Report NR12
Document N 155/2017
Customer Information:
Company: Embraer/Laselec
Address: Presidente Dutra Highway, km 134.
City: So Paulo, SP
CNPJ:
CNAE:
Telephone:
Machinery Information:
Contractor: Laselec
Date: 15/09/2017
2
Scientific Technical Report NR12
Document N 155/2017
TABLE OF CONTENTS
1. OBJECTIVES: ............................................................................. 5
2. LIMITATIONS: ........................................................................... 6
3. RISK ASSESSMENT METHODOLOGY ........................................... 7
3.1 Quantitative Method - HRN: ............................................................................. 8
3.2 Determination of the Safety Level to be adopted: ........................................... 11
4. MACHINERY IDENTIFICATION: ................................................ 13
4.1 Machinery General View: ................................................................................ 13
5. DETERMINATION OF THE LIMITS OF THE MACHINE*: ............. 14
5.1 Machinery Life Phases: ................................................................................... 14
5.2 Machinery Correct usage: ................................................................................ 14
5.3 Misuse Consequences: ..................................................................................... 14
6. MACHINERY DETECTED RISKS ESTIMATION: ........................... 15
6.1 Risk 1: Multi-spool Dereeler Monitored Movable Guard: ........................... 16
6.2 Risk 2: Multi-spool Dereeler Fixed Guard: .................................................. 17
6.3 Risk 3: Multi-spool Dereeler Casters: .......................................................... 18
6.4 Risk 4: Front Panel Monitored Movable Guard: .......................................... 19
6.5 Risk 5: Front Panel Translation of Information: ........................................... 20
6.6 Risk 6: Safety Reset Push-button: ................................................................... 21
7. OTHER RISKS........................................................................... 22
7.1 Electrical risks of the Facilities:....................................................................... 22
7.2 Ergonomic risks: .............................................................................................. 22
7.3 Chemical risks: ................................................................................................ 22
7.4 Biological risks: ............................................................................................... 22
7.5 Physical risks that are not present in this study: .............................................. 22
8. UTILIZED STANDARDS: ........................................................... 23
9. CONSIDERATIONS: .................................................................. 24
10. CONCLUSION: .......................................................................... 25
11. APPENDICES: ........................................................................... 26
11.1 Risks Matrix:.................................................................................................... 26
11.2 Chart HRN Before Safety Implementation:............................................... 27
11.3 Chart HRN After Safety Implementation: ................................................. 28
3
Scientific Technical Report NR12
Document N 155/2017
FIGURES:
TABLES:
4
Scientific Technical Report NR12
Document N 155/2017
1. Objectives:
Mapping, identifying and quantifying risks based on the current machine control
systems, considering constructive aspects and relevant standards including NR 12 of
Regulatory Standards 3.214 / 77 and Law 6.514 / 77 of the Ministry of Labor and
Employment, Brazilian Standards NBRs and international standards when necessary.
5
Scientific Technical Report NR12
Document N 155/2017
2. Limitations:
Normal operation;
Cleaning;
Setup;
Adjustment;
Maintenance operations that require a reduced safety level.
6
Scientific Technical Report NR12
Document N 155/2017
7
Scientific Technical Report NR12
Document N 155/2017
8
Scientific Technical Report NR12
Document N 155/2017
9
Scientific Technical Report NR12
Document N 155/2017
HRN Classification
0 - 0,99 Negligible
1 - 4,99 Very Low
5 - 9,99 Low
10 - 49,99 Significant
50 - 99,99 High
100 - 499,99 Very High
500 - 999,99 Extreme
Over 1000 Unacceptable
Actions shall be taken prioritizing the highest risks detected, risks classified from
"Negligible" to "Low" do not require intervention, and only the procedures to control the
existing residual risk are required. Risks classified from "Significant" to "Unacceptable" shall
be provided with guards or safety equipment considering the required category to seek
near-zero HRN values.
10
Scientific Technical Report NR12
Document N 155/2017
When the safety solution requires a control system (interface + sensors + actuators),
it is necessary to observe the safety category necessary to control the risk, so it is
necessary to use the same adopted parameters of Frequency, Exposure and Probability of
Harm Avoidance.
The determination of the safety level is provided in NBR 14153, which is the Brazilian
standard in this issue and presents the following tool for determining the safety category to
be adopted:
In order to align the new existing technologies with the updated risk analysis
demands, we chose to include in the Risk Assessment the methodology for determining the
requirements of a safety system according to ISO 13849-1 - PLr method, which covers all
electronic safety systems available and presents the possibility of analyzing system
performance and determining specific risk categories for each type of component. This tool
is more complex and requires a greater number of information and technical knowledge of
design and system specification. The picture below presents the tool for determining the
PLr (required) as determined in ISO 13849-1.
The purpose of this Risk Assessment is only to establish the required Performance
Level (PLr), so it is possible (when necessary) to use this parameter, which is already
Document Protected by Intellectual Property Law, All rights reserved to PAYBACK
11
Scientific Technical Report NR12
Document N 155/2017
available for several safety equipment manufacturers, to define which devices should be
purchased.
It is important to note that the regulatory requirements when redundancy, duplicity
and required category in type-C standards and NR12 takes precedence over the above
standards.
12
Scientific Technical Report NR12
Document N 155/2017
4. Machinery Identification:
13
Scientific Technical Report NR12
Document N 155/2017
This study analyzes only the machine utilization phase, considering the following
aspects:
- Regulation, training, programming or change of the manufacturing process;
- Running;
- Operation;
- Cleaning;
- Failure or breakdown research;
- Maintenance.
The machine has been set up to perform the laser marking of the cables, so any
changes in the process must be carefully analyzed in order to investigate whether this
change could cause additional risks not predicted by the manufacturer.
The operator must place the cable coils next to the multi-spool dereeler in order to
start the automatic cable marking process. Therefore, any other use than that specified by
the manufacturer may result in an unpredicted risk.
Disabling any item of the safety system is also characterized as incorrect use of the
equipment as this intervention is not determined by the machine manufacturer.
14
Scientific Technical Report NR12
Document N 155/2017
In the subitems below we observe and analyze in detail each point of the machine in
a probabilistic way in order to measure the risk before the safety implementation and
projecting the risk after the implementation, thus we have a measurement of the achieved
results and the existent residual risks.
15
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
The current movable guard is monitored by a tongue operated safety switch, which does not comply the
safety performance with the combination of components from different technologies.
Likelihood of Occurrence
2 - Possible RISK LEVEL - HRN = 40
(LO):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
Provide the installation of a magnetic safety switch, in addition to the existing tongue operated safety
switch. The entire system must be interconnected to a category 3 safety interface and it needs to have a
safety reset push-button positioned in a place that allows a clear and unobstructed view of the whole area.
Likelihood of Occurrence
0,1 - Almost impossible RISK LEVEL - HRN= 2
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 4- Loss of limb/eye/serious
Risk Classification: Very Low
(DPH): illness of a temporary nature
Number of Persons at risk
1 - 1-2 persons
(NP):
16
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
Currently there is an opening in the passage of the wire to the multi-spool dereeler, which allows free
access of upper limbs to the moving parts, therefore it does not meet the NR12 regulatory requirements.
Likelihood of Occurrence
5 - Even chance RISK LEVEL - HRN = 50
(LO):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
Provide the installation of a complement to the existing fixed guard, preventing access to the moving parts
of the equipment. The guard must be made of polycarbonate and fixed with screws that allow their removal
only with the use of tools. It shall also be considered the installation of a tunnel from one machine to another,
preventing any contact during the cable transfer.
Likelihood of Occurrence
0,5 - Highly unlikely RISK LEVEL - HRN= 1,5
(LO):
Frequency of Exposure (FE): 1,5 - Weekly
Degree of Possible Harm 2 - Break of a major bone or
Risk Classification: Very Low
(DPH): minor illness (permanent)
Number of Persons at risk
1 - 1-2 persons
(NP):
17
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
The current casters do not have brakes that maintain the machine stationary and steady, thus failing to meet
the item 12.12 of NR12.
Likelihood of Occurrence
5 - Even chance RISK LEVEL - HRN = 25
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 1 - Break of a minor bone or
Risk Classification: Significant
(DPH): minor illness (temporary)
Number of Persons at risk
1 - 1-2 persons
(NP):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
According to the regulatory requirements of NR12, at least two casters of a moveable machine shall have
brakes.
Likelihood of Occurrence
1 - Unlikely RISK LEVEL - HRN= 5
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 1 - Break of minor bone or
Risk Classification: Low
(DPH): minor illness (temporary)
Number of Persons at risk
1 - 1-2 persons
(NP):
18
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
The current movable guard is monitored by a tongue operated safety switch, which does not comply the
safety performance with the combination of components from different technologies.
Likelihood of Occurrence
2 - Possible RISK LEVEL - HRN = 40
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 4- Loss of limb/eye/serious
Risk Classification: Significant
(DPH): illness of a temporary nature
Number of Persons at risk
1 - 1-2 persons
(NP):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
Provide the installation of a magnetic safety switch, in addition to the existing tongue operated safety
switch. The entire system must be interconnected to a category 3 safety interface and it needs to have a
safety reset push-button positioned in a place that allows a clear and unobstructed view of the whole area..
Likelihood of Occurrence
0,1 - Almost impossible RISK LEVEL - HRN= 2
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 4- Loss of limb/eye/serious
Risk Classification: Very Low
(DPH): illness of a temporary nature
Number of Persons at risk
1 - 1-2 persons
(NP):
19
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
Currently the information of the machine functions on the HMI is in English, thus failing to meet the NR12
regulatory requirements, item 12.119.
Likelihood of Occurrence
1 - Unlikely RISK LEVEL - HRN = 0,5
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm
0,1 - Scratch or bruise Risk Classification: Negligible
(DPH):
Number of Persons at risk
1 - 1-2 persons
(NP):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
Provide the translation to Brazilian Portuguese of all the information of the HMI, which represents the
functions of each device of the machine, in order to meet the item 12.119 regulatory requirements.
Likelihood of Occurrence
0,5 - Highly unlikely RISK LEVEL - HRN= 0,25
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm
0,1 - Scratch or bruise Risk Classification: Negligible
(DPH):
Number of Persons at risk
1 - 1-2 persons
(NP):
20
Scientific Technical Report NR12
Document N 155/2017
RISK ASSESSMENT
Risk Description:
Currently the machine does not have a safety reset push-button related to the emergency system, thus it
does not comply with NR12 regulatory requirements.
Likelihood of Occurrence
2 - Possible RISK LEVEL - HRN = 40
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 4- Loss of limb/eye/serious
Risk Classification: Significant
(DPH): illness of a temporary nature
Number of Persons at risk
1 - 1-2 persons
(NP):
EQUIPMENT PICTURES
PICTURE 1 PICTURE 2
The equipment safety system must have a safety reset push-button for the whole system, to be performed
only after the correction of the event that caused the emergency stop actuation, in order to comply with
NR12 regulatory requirements, item 12.63.
Likelihood of Occurrence
0,1 - Almost impossible RISK LEVEL - HRN= 2
(LO):
Frequency of Exposure (FE): 5 - Constantly
Degree of Possible Harm 4- Loss of limb/eye/serious
Risk Classification: Very Low
(DPH): illness of a temporary nature
Number of Persons at risk
1 - 1-2 persons
(NP):
21
Scientific Technical Report NR12
Document N 155/2017
7. Other Risks
Thermal stress
Noise
Radiation
Pressure
Vibration
Humidity
22
Scientific Technical Report NR12
Document N 155/2017
8. Utilized Standards:
23
Scientific Technical Report NR12
Document N 155/2017
9. Considerations:
Operators should be trained and aware of the risks and control measures adopted up
to this date.
All design and / or modification in the machine must be developed or supervised by a
legally qualified professional with ART collection.
In addition, systems implemented by the company must be maintained and verified
by operators and maintenance staff to ensure their efficiency as provided in NR12.
24
Scientific Technical Report NR12
Document N 155/2017
10. Conclusion:
25
Scientific Technical Report NR12
Document N 155/2017
11. Appendices:
11.1 Risks Matrix:
26
Scientific Technical Report NR12
Document N 155/2017
Risk 2
Risk 3
Risk 4
Risk 5
Risk 6
Negligible Very Low Low Significant High Very High Extreme Unacceptable
27
Scientific Technical Report NR12
Document N 155/2017
Risk 2
Risk 3
Risk 4
Risk 5
Risk 6
Negligible Very Low Low Significant High Very High
28