Vous êtes sur la page 1sur 156

2015 Fall Product Catalog

ADVANCED CONTROLS & DRIVES

A Regal Brand
24/7/365
Service and Support

Field Services: Maintenance Services:


Installations and commissioning Thermography
On-site repairs Service contracts
Scheduled / emergency Preventive
On-site retrofits and upgrades Maintenance/agreements
Power quality
Factory Services:
Send-in repair Spare Parts:
Scheduled / emergency 24 / 7 / 365 availability
Send-in retrofits and upgrades Emergency delivery
Quick ship modified Benshaw Courier available
Express stock
Replace or repair
Benshaw and 3rd party
Technology Retrofits:
Technical Training: Solid state motor controls and drives
In-class in our training center Electromechanical motor controls
In-class at your facility
Customized for your business

Return to the
benshaw.com Table of Contents
Medium Voltage Variable
Frequency Drives
...................................................... Section 1

Low Voltage Variable


Frequency Drives
...................................................... Section 2

Medium Voltage Starters


...................................................... Section 3

Low Voltage Starters


...................................................... Section 4

Wye Delta Starters


...................................................... Section 5

Pump Control Starters


...................................................... Section 6

Return to the
Table of Contents
Return to the
benshaw.com Table of Contents
Medium Voltage Variable
Frequency Drives

Engineered Medium Voltage


Drive Products
M2L 3000 Series..................................1-2

Return to the
Table of Contents 1-1
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series 2.311 kV Class, 30090,000 HP

Product Highlights:
With over 30 years of medium voltage motor controls experience, Benshaw is now
introducing a new family of medium voltage drives. Our medium voltage drive features
a unique technology that allows Benshaw to offer a simple, compact and reliable drive
solution. Our innovative topology, coupled with an advanced control architecture, will
enable customers to transform the way they do business.

Developed, designed and The M2L 3000 Medium Voltage Variable Frequency Drive is a step change in motor
control power technology. Though designed for industrial applications, it benefits
manufactured in the USA. from Benshaws wide-ranging experience in defense and nuclear-related technologies,
Supported around the globe. an arena where products must meet the most rigorous standards and where failure is
simply not an option.

Our innovative patented topologymodular multilevel converter (M2LC)is powered


by state-of-the-art hardware and software controls. Our control algorithms are setting
the stage for the next generation of VFDs.

Key Features:
Compact Modular Design
Simplistic component arrangement with minimal total part count
Installation Flexibility
Optimal for retrofits
Arc Resistant
Safety by designarc flash footprint inherently lower
Energy Efficiency
Inverter efficiency 99.5%
Robust Control Architecture
High performance, reliability and immunity from EMI through noise-tolerant
signaling and fiber optic communications

Return to the
1-2 benshaw.com
benshaw.com Table of Contents
Variable Frequency Drives
M2L 3000 Series
M2L Topology
Power is fed to the M2L inverter from a standard, easily sourced isolation transformer, which
can be placed in a remote or outdoor location. All M2L drive systems are compliant with
IEEE519-1992 input harmonic current requirements through the use of an 18-pulse input
transformer (standard).

+ BUS

CELL CELL CELL


A2 B2 C2

CELL CELL CELL


-20 A4 B4 C4

CELL CELL CELL


A6 B6 C6

L1 T1

L2 T2 AC MOTOR
0

T3
L3

CELL CELL CELL GND


A5 B5 C5

20 CELL CELL CELL


A3 B3 C3

CELL CELL CELL


A1 B1 C1

- BUS

M2L Topology

Return to the
Table of Contents 1-3
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series
M2L Topology
Energy storage is distributed among identical power modules that comprise the M2LC inverter,
which greatly reduces arc flash potential and substantially improves reliability.
POWER SUPPLY BOARD
CELL CONTROL &

Cell detail

Each cell in the inverter contains two fourth-generation IGBT switching modules and uses only
high-reliability dry-type film capacitors. Embedded circuitry in each cell provides intelligence
for control and communication.

Return to the
1-4 benshaw.com Table of Contents
Variable Frequency Drives
M2L 3000 Series
Advanced Features and Configurations
Benshaw provides an integrated synchronous transfer scheme using the M2L drive and an
intelligent PLC control center. Synchronous, or bi-directional bumpless, transfer allows a
single inverter to start up to six individual motors and smoothly transfer them to across-the-
line operation.

INCOMING
POWER
VFD INPUT LINE LINE LINE LINE
DISCONNECT DISCONNECT DISCONNECT DISCONNECT DISCONNECT
MV FUSE

MV FUSE

MV FUSE

MV FUSE

MV FUSE
VFD OUTPUT
VFD INPUT DISCONNECT DISCONNECT DISCONNECT DISCONNECT DISCONNECT
CONTACTOR (OPTIONAL) (OPTIONAL) (OPTIONAL) (OPTIONAL) (OPTIONAL)

LINE VFD LINE VFD LINE VFD LINE VFD


DECOUPLING ISOLATION ISOLATION ISOLATION ISOLATION ISOLATION ISOLATION ISOLATION ISOLATION
CONTACTOR CONTACTOR CONTACTOR CONTACTOR CONTACTOR CONTACTOR CONTACTOR CONTACTOR
REACTOR

3 CONDUCTORS
(MIN)

M2L SERIES
INVERTER

2 CONDUCTORS INDUCTION INDUCTION INDUCTION INDUCTION


(MIN) MOTOR #1 MOTOR #2 MOTOR #3 MOTOR #4

M2L SERIES
CONVERTER

3 CONDUCTORS
(MIN)

Single-line diagram of a typical four-motor synchronous transfer scheme

Return to the
Table of Contents 1-5
Engineered Medium
Voltage Drive Products
Variable Frequency Drives
M2L 3000 Series
Advanced Features and Configurations
High speed communication architecture enables the connection of up to eight inverter sections
in parallel, providing clean, multi-level PWM output for motors up to 90,000 HP.

DC LINK AC
REACTOR INVERTER REACTOR
SECTION

MASTER
INDUCTION
MOTOR
XFMR/RECTIFIER
INCOMING STD-EE TC-OF
(CONVERTER)
POWER
ASSEMBLY

DC LINK AC
REACTOR INVERTER REACTOR
SECTION

STD-EE
FOLLOWER

PROCESS STD-EE STD-EE: STANDARD ELECTRICAL ETHERNET


CONTROL ROUTER TC-OF: TIME CRITICAL OPTICAL FIBER
INTERFACE

LAPTOP
HMI (BENSHAW
STD-EE CONNECT)

SINGLE MACHINE INTERFACE

Example of two parallel inverter sections

Contact your regional sales manager for more information and to obtain a quote.

Return to the
1-6 benshaw.com Table of Contents
Low Voltage Variable
Frequency Drives

Standard Low Voltage Drive Products


General Purpose Micro Drives............2-2

Sensorless Vector Drives.....................2-5

NEMA 4X Washdown / NEMA 12


Sensorless Vector Drives...................2-10

Built-to-Order Packaged Drives........2-14

Standard Low Voltage Drive Options


Input Line Reactors...........................2-19

Output Reactors................................2-25

Long Lead Filters.............................. 2-27

Dynamic Brake Resistors


and Brake Modules...........................2-30

Engineered Low Voltage Drive Products


VFD Pre-Order Check List.................2-32

Sensorless Vector Drives...................2-35

Integrated Control Solutions.............2-52

Custom-Engineered
Drive Solutions..................................2-54

Clean Power Drives...........................2-55

Return to the
Table of Contents 2-1
Standard Low Voltage
Drive Products
General Purpose Micro Drives
GX Series 15 HP, 230 / 460 V / Protected Chassis / NEMA 1*
Product Highlights:
RATINGS The GX series is a compact, economical chassis drive designed
for low horsepower applications.
Constant Torque:
The GX series has a powerful set of parameters with a simple, easy to use keypad.
15 HP @ 460 V The programming structure provides quick, simple setup.
15 HP @ 230 V Although small in size, the GX series provides a large amount of digital I/O
*Chassis VFD converts to for custom applications.
NEMA 1 with conduit kit
Key Advantages:
Small, compact design
Constant torque rated
Sensorless vector control or V/Hz control
Standard dynamic braking transistor (external resistor required)
Flexible, programmable I/O
Integral PID control
Standard ModBus RTU terminals
Windows based software
Standard Features:
Standard I/O: 8 digital inputs, 2 analog inputs, 1 analog output, 1 relay output,
1 open collector output
Digital metering: Output current, output frequency, DC link voltage, motor RPM,
output power, output voltage, output torque
Protection: Over current, ground fault, over voltage, current limit, motor overload,
output phase loss, over heat, loss of signal and more
Communications: ModBus RTU (standard)
Voltage tolerance: 10%
Control methods: Open loop V / Hz, sensorless vector control
V / Hz patterns: Linear, squared, user programmable V / Hz
Analog output functions: 1 analog output 010 VDC: Configurable to motor
speed, output current, output voltage, DC link voltage
Analog inputs: 1 at 0/420 mA, 1 at 010 VDC
Relay output and open collector output: 1 Form C relay output and 1 open
collector output, programmable to running, faulted, stopped, ready, at speed,
high or low frequency levels, loss of signal and more
Digital inputs: 8 digital inputs configurable to forward run, reverse run, 3 wire
start / stop, reset, jog, preset speeds, motorized pot function, external trip,
alternate ramp selections, HOA and more
User interface: 4 digit LED display
Stop methods: Coast, decel, DC injection braking and optional dynamic braking

Return to the
2-2 benshaw.com Table of Contents
General Purpose Micro Drives
GX Series
Control Terminal Layout LED Status
display indicators

Run / stop
buttons

Left / right up /
down keys

Save
parameters

Programmable
I/O

Modbus
terminal

T/M Description
MO Multi-Function Open Collector Output
MG MO Common
24 24 V Power Supply (100 mA Max.)
P1 Fx: Forward Run
Multi-Function Input Terminal (Factory Setting)
P2 Rx: Reverse Run
CM Input Signal Common
P3 Bx: Emergency Stop
P4 Multi-Function Input Terminal (Factory Setting) Rst: Trip Reset
P5 Jog: Jog Operation
CM Input Signal Common
P6 Multi-Step Freq.Low
P7 Multi-Function Input Terminal (Factory Setting) Multi-Step Freq.Middle
P8 Multi-Step Freq.High
VR 10 V Power Supply For Potentiometer
V1 Freq. Setting Voltage Signal Input: -010 V
I Freq. Setting Current Signal Input: 020 MA
AM Multi-Function Analog Output Signal: 010 V
3A Normally Open Contact
3B Multi-Function Relay Output Terminal Normally Closed Contact
3C Common
S+
RS485 Communication Terminal
S

Return to the
Table of Contents 2-3
Standard Low Voltage
Drive Products
General Purpose Micro Drives
GX Series
Protected Chassis, 15 HP, 230 / 460 V

230 V
Constant Torque Dimensions (in.)
Model Number HP Amps H W D Weight (lbs.) List Price
RSI-001-GX-2B 1 4.2 5 2.8 5.1 2 $500.00
RSI-002-GX-2B 2 6.8 5 3.9 5.1 3 $600.00
RSI-003-GX-2B 3 9.6 5 5.5 6.1 4 $700.00
RSI-005-GX-2B 5 15.2 5 5.5 6.1 5 $800.00

460 V
Constant Torque Dimensions (in.)
Model Number HP Amps H W D Weight (lbs.) List Price
RSI-001-GX-4B 1 2.1 5 2.8 5.1 2 $600.00
RSI-002-GX-4B 2 3.4 5 3.9 5.1 3 $700.00
RSI-003-GX-4B 3 4.8 5 5.5 6.1 4 $750.00
RSI-005-GX-4B 5 7.6 5 5.5 6.1 5 $900.00

NEMA 1 Conduit Kits


Model Number Description List Price
GX-NEMA1KIT-A Conduit Kit for 1 HP GX Drive $60.00
GX-NEMA1KIT-B Conduit Kit for 2 HP GX Drive $60.00
GX-NEMA1KIT-C Conduit Kit for 3 HP and 5 HP GX Drive $60.00

Remote Keypad
Model Number Description List Price
VFD-2M-GX-KEYPAD Remote Mount Keypad and 2 Meter Cable $175.00
Units are stocked as protected chassis. If NEMA 1 enclosed is required, add NEMA 1 conduit kit.
Conduit kits will need to be installed by customer.

Web stocked
Available for same day shipping.

Return to the
2-4 benshaw.com Table of Contents
Sensorless Vector Drives
SG Series Variable Torque / Standard Duty / Heavy Duty
Product Highlights:
RATINGS The SG series is a compact, economical drive designed for the most demanding applications.
The flexible power stack allows the user to apply it to heavy duty loads (150% for 60 secs),
Variable Torque: standard duty loads (120% for 60 secs), or variable torque loads (110% for 60 secs).

7.540 HP @ 230 V With over 250 programmable parameters, Benshaws SG series drives are configurable
7.5700 HP @ 460 V to meet the needs of almost any industrial application, yet remain simple and easy to use.
7.5400 HP @ 600 V
Key Advantages: Communications: Modbus RTU
(standard); Optional Fieldbus includes
Standard and heavy duty ratings DeviceNet, Profibus, BacNet, LonWorks,
Standard Duty:
Integral PID Control Modbus TCP
7.540 HP @ 230 V Sensorless vector control or V/Hz control Voltage tolerance: -15%, +10%
7.5600 HP @ 460 V
Integral multiple motor control Control methods: V/Hz, sensorless
7.5400 HP @ 600 V for pumping applications vector, slip compensation
Uploadable / downloadable keypad V/Hz patterns: Linear, squared,
Heavy Duty: user programmable V/Hz
Flexible, programmable I/O
Analog outputs: 2 at 010 VDC
530 HP @ 230 V Economical, compact design
(standard), 2 at 0/420 mA (with option
5500 HP @ 460 V Simple, easy to use LCD interface board). Configurable to motor speed,
5300 HP @ 600 V Standard ModBus RTU port output current, output voltage, DC link
voltage, power, PID follower
Windows-based software
Relay outputs: 1 Form C fault relay
Standard Features: output, 4 Form A relay outputs
configurable to running, faulted, ready,
Standard I/O: 8 digital inputs, at speed, high or low frequency levels,
2 analog inputs, 2 analog outputs,
loss of signal, ready and more
5 relay outputs
Digital inputs: 8 digital inputs
Optional I/O: Isolated analog output configurable to forward run, reverse
board (adds 2 additional analog outputs,
run, 3 wire start / stop, reset, jog, preset
0/420 mA)
speeds, motorized pot function, external
Digital metering: Output currents, trip, alternate ramp selections, HOA
ground current, output frequency, DC and more
link voltage, motor RPM, output motor
User interface: 2 line LCD display,
voltage, run time and more
16 characters per line
Protection: Over current, ground Stop methods: Coast, decel, DC injection
fault, over voltage, current limit, motor
braking, Flux braking and optional
overload, phase loss, over heat, loss of
dynamic braking
signal and more
Analog inputs: 1 at 0/420 mA,
1 at 010 VDC (or -10 to 10 VDC)

Return to the
Table of Contents 2-5
Standard Low Voltage
Drive Products
Sensorless Vector Drives
SG Series
Basic Wiring Diagram

DB UNIT
(option)

MCCB1 MC1 ACR


P1P2 N U
R U
V
S V M
W
T W Motor

3 Phase G E/G E
AC input
RSi-SG Safety stop
Setting CN1 (600V only)
Switch Sourcing
24G Mode PNP

24 VDC (50mA max) Sinking


24 24P Mode NPN V1 0[V]~+12[V]

Default: Speed-L M1
V1S -12[V]~+12[V] Analog
Default: Speed-M M2 input
Default: Speed-H M3 I 0/4[mA]~20[mA]

Default: RST M4
BX (E-STOP) M5 5G
Default: JOG M6
Default: FX M7 S0 Default: Frequency Analog meter
Default: RX M8 Max output
S1 Default: Voltage
voltage:12V
CM Source max: 30mA
24V 4.9mA 5G Sink max: 20mA
24G

A1
3A
C1
3C
Fault relay output
A2 3B 250Vac, 1A

Relay outputs C2 24G


programmable Aux. relays
250Vac, 1A A3
C3 A0
A4 B0 Pulse
input
C4
5G
24G
Pulse input method: (A+B), (A)
Terminating
resistor Input freq: 0Hz~100KHz

C-
NT
RS-485 C+
Motor thermal
24G 5G detection

Return to the
2-6 benshaw.com Table of Contents
Sensorless Vector Drives
SG Series
NEMA 1

230 V
Variable Torque Standard Duty Heavy Duty Dimensions (in.)
Weight
Model Number HP Amps HP Amps HP Amps H W D (lbs.) List Price
RSI-007-SG-2B 7.5 24 7.5 22 5 17 11.2 5.9 6.2 11 $1,400.00
RSI-010-SG-2B 10 32 10 29 7.5 23 11.2 7.9 7.2 14 $1,600.00
RSI-015-SG-2B 15 46 15 42 10 33 11.2 7.9 7.2 14 $1,750.00
RSI-020-SG-2B 20 60 20 55 15 44 17.9 9.8 7.9 28 $2,285.00
RSI-025-SG-2B 25 74 25 67 20 54 17.9 9.8 7.9 29 $2,985.00
RSI-030-SG-2B 30 88 30 80 25 68 23.6 12 9.2 44 $3,500.00
RSI-040-SG-2B 40 115 40 105 30 84 23.6 12 9.2 44 $4,125.00

460 V
Variable Torque Standard Duty Heavy Duty Dimensions (in.)
Weight
Model Number HP Amps HP Amps HP Amps H W D (lbs.) List Price
RSI-007-SG-4B 7.5 12 7.5 11 5 8 11.2 5.9 6.2 11 $1,425.00
RSI-010-SG-4B 10 16 10 14 7.5 11 11.2 7.9 7.2 14 $1,725.00
RSI-015-SG-4B 15 24 15 22 10 17 11.2 7.9 7.2 14 $1,885.00
RSI-020-SG-4B 20 30 20 27 15 22 17.9 9.8 7.9 28 $2,450.00
RSI-025-SG-4B 25 39 25 35 20 28 17.9 9.8 7.9 29 $2,800.00
RSI-030-SG-4B 30 45 30 41 25 34 23.6 12 9.2 44 $3,545.00
RSI-040-SG-4B 40 61 40 55 30 44 23.6 12 9.2 44 $4,250.00
RSI-050-SG-4B 50 75 50 68 40 55 25.3 12.1 10.5 60 $5,225.00
RSI-060-SG-4B 60 91 60 83 50 66 25.3 12.1 10.5 60 $6,500.00
RSI-075-SG-4B 75 110 75 100 60 80 25.3 12.1 11.2 64 $7,500.00
RSI-100-SG-4B 100 152 100 139 75 111 30.2 14.5 12.1 95 $9,000.00
RSI-125-SG-4B 125 183 125 167 100 134 30.2 14.5 12.1 95 $11,000.00
RSI-150-SG-4 * 150 223 150 204 125 164 30.9 20.1 16.6 225 $13,000.00
RSI-200-SG-4 * 200 264 200 242 150 194 30.9 20.1 16.6 225 $15,500.00
RSI-250-SG-4 * 250 325 250 302 200 240 33.9 20.1 16.6 255 $18,000.00
RSI-350-SG-4 * 350 432 300 396 250 317 42.5 27.2 17.3 450 $23,000.00
RSI-400-SG-4 * 400 547 400 501 300 401 42.5 27.2 17.3 450 $32,000.00
RSI-500-SG-4 500 613 450 562 350 450 44.9 30.8 17.4 540 $40,000.00
RSI-600-SG-4 600 731 500 670 400 536 51.3 36.3 19.5 840 $48,000.00
RSI-700-SG-4 700 877 600 804 500 643 51.3 36.3 19.5 840 $57,750.00
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute
Units ending in a B designate NEMA 1. Units not ending in a B are protected chassis units.
Protected chassis only (power terminal covers do not meet NEMA 1).
* DC Link Reactor (internal)

Web stocked
Available for same day shipping.

Return to the
Table of Contents 2-7
Standard Low Voltage
Drive Products
Sensorless Vector Drives
SG Series
NEMA 1 / Protected Chassis

600 V
Variable Torque Standard Duty Heavy Duty Dimensions (in.)
Weight
Model Number HP Amps HP Amps HP Amps H W D (lbs.) List Price
RSI-007-SG-6B 7.5 9 7.5 8.2 5 6.6 14 7.9 7.2 15 $1,650.00
RSI-010-SG-6B 10 12 10 11 7.5 9 14 7.9 7.2 16 $1,725.00
RSI-015-SG-6B 15 17 15 15.5 10 12 14 7.9 7.2 16 $1,885.00
RSI-020-SG-6B 20 23 20 21 15 17 17.9 9.8 7.9 28 $2,450.00
RSI-025-SG-6B 25 27 25 24.7 20 19.8 17.9 9.8 7.9 29 $2,800.00
RSI-030-SG-6B 30 34 30 31 25 25 23.6 12 9.2 44 $3,545.00
RSI-040-SG-6B 40 43 40 39 30 31.5 23.6 12 9.2 44 $4,250.00
RSI-050-SG-6B 50 55 50 50 40 43 25.3 11.8 11.5 71 $5,225.00
RSI-060-SG-6B 60 64 60 58.6 50 55 25.3 11.8 11.5 71 $6,750.00
RSI-075-SG-6B 75 80 75 73 60 64 25.3 11.8 11.5 71 $7,850.00
RSI-100-SG-6B 100 104 100 95 75 80 30.2 14.6 13.3 102 $9,125.00
RSI-125-SG-6B 125 128 125 117 100 104 30.2 14.6 13.3 102 $11,125.00
RSI-150-SG-6 * 150 150 150 137 125 128 30.9 20 16.6 225 $13,100.00
RSI-200-SG-6 * 200 200 200 184 150 147 33.9 20 16.6 255 $16,250.00
RSI-250-SG-6 * 250 242 250 222 150 177 33.9 20 16.6 255 $21,000.00
RSI-350-SG-6 * 350 333 300 305 250 244 42.5 27.2 17.7 450 $23,785.00
RSI-400-SG-6 * 400 424 400 389 300 311 42.5 27.2 17.7 450 $32,845.00
Variable Torque = 110% current for 1 minute / Standard Duty = 120% current for 1 minute / Heavy Duty = 150% current for 1 minute
Units ending in a B designate NEMA 1. Units not ending in a B are protected chassis units.
Protected chassis only (power terminal covers do not meet NEMA 1).
* DC Link Reactor

Web stocked

Return to the
2-8 benshaw.com Table of Contents
Sensorless Vector Drives
SG Series
Options

Dynamic Brake Transistor Modules


Model Number Description List Price
VFD-RSI-DBU-020-2 230V Dynamic Braking Transistor for 120 HP VFD, 10% Duty Cycle $1,100.00
VFD-RSI-DBU-030-2 230V Dynamic Braking Transistor for 2530 HP VFD, 10% Duty Cycle $1,200.00
VFD-RSI-DBU-050-2 230V Dynamic Braking Transistor for 4050 HP VFD, 10% Duty Cycle $1,300.00
VFD-RSI-DBU-020-4 460V Dynamic Braking Transistor for 120 HP VFD, 10% Duty Cycle $1,100.00
VFD-RSI-DBU-030-4 460V Dynamic Braking Transistor for 2530 HP VFD, 10% Duty Cycle $1,200.00
VFD-RSI-DBU-050-4 460V Dynamic Braking Transistor for 4050 HP VFD, 10% Duty Cycle $1,300.00
VFD-RSI-DBU-075-4 460V Dynamic Braking Transistor for 6075 HP VFD, 10% Duty Cycle $1,600.00
VFD-RSI-DBU-100-4 460V Dynamic Braking Transistor for 100 HP VFD, 10% Duty Cycle $1,700.00
For HP greater than 100 HP or duty cycle greater than 10%, consult factory.

Fieldbus Communication Cards


Model Number Description List Price
PC-400001-00 DeviceNet Communication Board Kit, SG VFD $575.00
PC-400002-00 Profibus Communication Board Kit, SG VFD $885.00
PC-400003-00 LonWorks Communication Board Kit, SG VFD $1,000.00
PC-400004-00 BacNet Communication Board Kit, SG VFD $1,325.00
PC-400005-00 Ethernet IP/Modbus TCP Communication Board Kit, SG VFD $1,100.00

Display / Keypad Remote Mounting


Model Number Description List Price
LCD-100000-00 Replacement Display / Keypad $200.00
VFD-2M-RE-CABLE-SG 2 Meter Keypad Cable $110.00
VFD-3M-RE-CABLE-SG 3 Meter Keypad Cable $135.00
VFD-5M-RE-CABLE-SG 5 Meter Keypad Cable $145.00
VFD-KEYPAD-SG-BEZEL Bezel, for SG Keypad, Remote Mounting $20.00
VFD-KEYPAD-SG-BLANK Keypad Blank, Installs in Drive when Keypad Is Remote $20.00

Analog Output Card


Model Number Description List Price
VFD-RSI-SG-4-20-MA 420 mA Output Card, Adds (2) 420 mA Outputs $725.00

Return to the
Table of Contents 2-9
Standard Low Voltage
Drive Products
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series Standard Duty / Heavy Duty
RSI S4 Series Product Highlights:
RATINGS The S4 Series is a line of high performance NEMA 4X washdown variable frequency
drives. Benshaws S4 variable frequency drives are built to withstand the harshest
Constant Torque: environments and hold up under your most demanding pressure washing applications.
All S4 Series drives combine a simple user interface with an array of features and are
1 HP @ 115 V
suited to almost any indoor environment.
1 to 20 HP @ 230 V
1 to 200 HP@ 460 V / 600 V S4 variable frequency drives come standard with over 180 configurable parameters
to match specific application and interface requirements. A standard dynamic braking
transistor and resistor are also included for regenerative applications.

Key Advantages:
NEMA 4X washdown duty enclosure
Sensorless vector control
Standard braking transistor and resistor
Infrared programming port
Standard and Heavy Duty ratings
LCD plain English display
Simple, easy-to-use interface
Standard ModBus communication port
Integral Pl control
Standard Features:
NEMA 4X washdown enclosure
Standard l/O: 10 digital inputs, 2 analog inputs, 2 analog outputs, 2 relay outputs
Digital metering: Output current, output volts, power, MWh meter, run time,
power on time, bus voltage, output frequency
Communications: ModBus standard, optional other Fieldbus
Voltage tolerance: 10%
Sensorless vector control
V / Hz Pattern: Linear, quadratic
Analog output functions: Output voltage, output current, drive load, drive temp,
stator frequency, output power
Analog inputs: 010VDC, 420mA, -10VDC to 10VDC, pulse train input
Relay outputs: Running, forward, reverse, ready, faulted, at speed, keypad
control, adjustable torque levels, adjustable current levels, PID limits, loss of
reference, timers
10 digital inputs configurable: Run, preset speeds, jogging, PID disable,
fault reset, drive enable, timers, motorized pot
User interface: 20 character LCD display, infrared programming port
Braking functions: Decal, coast, DC injection, dynamic braking
Units 1100HP are NEMA 4X; units 125200HP are NEMA 12

Return to the
2-10 benshaw.com Table of Contents
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
Basic Wiring Diagram

+24 VDC +24 NC2

Forward Run FWD RC2 Relay #2

Reverse Run REV NO2

Jog R/J NC1

Digital Input #1 DI1 RC1 Relay #1

Digital Input #2 DI2 NO1

Digital Input #3 DI3 DO1 Digital Output #1

Digital Input #4 DI4 DO2 Digital Output #2

Digital Input #5 DI5 DOQ Pulse Train Output

External Fault MOL dcom Common

Enable EN dcom Common

dcom Imet 420 mA output

cin+ acom Analog Common

420 mA input
cin- Vmet 010 VDC Output

+10 acom Analog Common

010 VDC Input Vin1

acom

0 10 VDC Input Vin2

Return to the
Table of Contents 2-11
Standard Low Voltage
Drive Products
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
NEMA 4X / 230 V
Standard Duty Heavy Duty Dimensions (in.) Weight
Model Number HP Amps HP Amps H W D (lbs.) List Price
RSI-001-S4-2W 1 4.2 0.5 2.5 9.5 6.5 6.1 9 $1,685.00
RSI-002-S4-2W 2 6.8 1 4.8 9.5 6.5 6.1 9 $1,700.00
RSI-003-S4-2W 3 9.6 2 7.8 9.5 6.5 8.5 9 $1,750.00
RSI-005-S4-2W 5 15.2 3 11 12 8.7 6.5 14 $2,050.00
RSI-007-S4-2W 7.5 22 5 17.5 12 8.7 6.5 14 $2,150.00
RSI-010-S4-2W 10 28 7.5 25.3 17.4 10.8 7.9 30 $3,650.00
RSI-015-S4-2W 15 42 10 37.2 17.4 10.8 7.9 30 $3,950.00
RSI-020-S4-2W 20 54 15 48.3 20.2 11.3 11.7 50 $5,895.00
RSI-025-S4-2W 25 68 20 62.1 20.2 11.3 11.7 50 $6,500.00

110 V Input / 230 V Output


Standard Duty Heavy Duty Dimensions (in.)
Model Number HP Amps HP Amps H W D Weight (lbs.) List Price
RSI-001-S4-1SW 1 4.2 0.5 2.5 9.5 6.5 6.1 9 $1,725.00
Single phase 110 V input / 3 phase 230 V output

Web stocked

NEMA 4X / NEMA 12 / 460 V


Standard Duty Heavy Duty Dimensions (in.)
Model Number HP Amps HP Amps H W D Weight (lbs.) List Price
RSI-001-S4-4W 1 2.1 0.5 1.1 9.5 6.5 6.1 9 $1,650.00
RSI-002-S4-4W 2 3.4 1 2.1 9.5 6.5 6.1 9 $1,700.00
RSI-003-S4-4W 3 4.8 2 3.4 9.5 6.5 8.5 9 $1,750.00
RSI-005-S4-4W 5 7.6 3 4.8 12 8.7 6.5 14 $2,200.00
RSI-007-S4-4W 7.5 11 5 7.6 12 8.7 6.5 14 $2,250.00
RSI-010-S4-4W 10 14 7.5 11 12 8.7 6.5 14 $2,300.00
RSI-015-S4-4W 15 21 10 14 17.4 10.8 7.9 30 $3,700.00
RSI-020-S4-4W 20 27 15 21 17.4 10.8 7.9 30 $4,000.00
RSI-025-S4-4W 25 34 20 27 17.4 10.8 7.9 30 $4,250.00
RSI-030-S4-4W 30 40 25 34 17.4 10.8 7.9 30 $4,575.00
RSI-040-S4-4W 40 52 30 40 20.2 11.3 11.7 50 $7,250.00
RSI-050-S4-4W 50 65 40 52 20.2 11.3 11.7 50 $7,500.00
RSI-060-S4-4W 60 77 50 65 29.4 12.9 13.8 110 $12,500.00
RSI-075-S4-4W 75 96 60 77 29.4 12.9 13.8 110 $13,000.00
RSI-100-S4-4W 100 124 75 96 29.4 12.9 13.8 110 $15,550.00
RSI-125-S4-4D * 125 156 100 124 50.5 16.5 18 354 $22,750.00
RSI-150-S4-4D * 150 180 125 156 50.5 16.5 18 354 $24,750.00
RSI-200-S4-4D * 200 240 150 180 50.5 16.5 18 354 $25,500.00


Web stocked
* Units ending In D are NEMA 12 and not washdown rated.

Return to the
2-12 benshaw.com Table of Contents
NEMA 4X Washdown /
NEMA 12 Sensorless Vector Drives
S4 Series
NEMA 4X / NEMA 12 / 600 V
Standard Duty Heavy Duty Dimensions (in.) Weight
Model Number HP Amps HP Amps H W D (lbs.) List Price
RSI-001-S4-6W 1 1.7 0.5 0.9 12 8.7 6.5 14 $2,000.00
RSI-002-S4-6W 2 2.7 1 1.7 12 8.7 6.5 14 $2,200.00
RSI-003-S4-6W 3 3.9 2 2.7 12 8.7 6.5 14 $2,250.00
RSI-005-S4-6W 5 6.1 3 3.9 12 8.7 6.5 14 $2,275.00
RSI-007-S4-6W 7.5 9 5 6.1 12 8.7 6.5 14 $2,450.00
RSI-010-S4-6W 10 11 7.5 9 12 8.7 6.5 14 $2,550.00
RSI-015-S4-6W 15 17 10 11 17.4 10.8 7.9 30 $4,250.00
RSI-020-S4-6W 20 22 15 17 17.4 10.8 7.9 30 $4,350.00
RSI-025-S4-6W 25 27 20 22 17.4 10.8 7.9 30 $4,500.00
RSI-030-S4-6W 30 32 25 27 17.4 10.8 7.9 30 $5,200.00
RSI-040-S4-6W 40 41 30 32 20.2 11.3 11.7 50 $7,500.00
RSI-050-S4-6W 50 52 40 41 20.2 11.3 11.7 50 $7,895.00
RSI-060-S4-6W 60 68 50 52 29.4 12.9 13.8 110 $13,500.00
RSI-075-S4-6W 75 82 60 62 29.4 12.9 13.8 110 $13,750.00
RSI-100-S4-6W 100 107 75 77 29.4 12.9 13.8 110 $15,500.00
RSI-125-S4-6D * 125 125 100 99 50.5 16.5 18 354 $23,250.00
RSI-150-S4-6D * 150 144 125 125 50.5 16.5 18 354 $24,500.00
RSI-200-S4-6D * 200 192 150 140 50.5 16.5 18 354 $27,450.00
* Units ending In D are NEMA 12 and not washdown rated.

Return to the
Table of Contents 2-13
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series Standard Duty / Heavy Duty

RATINGS

Standard Duty: Control


SG Series
power
sensorless
7.540 HP @ 230 V transformer
vector drive
7.5125 HP @ 460 V

Heavy Duty:
Input circuit
530 HP @ 230 V breaker and
disconnect
5100 HP @ 460 V

User
terminal
strip Bypass
contactor

Product Highlights:
Benshaws Built-To-Order packaged drives meet UL and CE approvals and are
available with standard (7.5125 HP) and heavy duty (5100 HP) ratings to meet
your drive requirements.

Key Advantages: Control power transformer


Standard and heavy duty ratings User input and output power
connections
UL and CE approvals
-10 to 40 C operating environment
Pre-designed options configurable temperature range
to your application
-20 to 65 C storage temperature
Operating Conditions:
Options:
Operating Temperature: -10 to 40C
Circuit breaker
Storage Temperature: -20C to 65C
Disconnect fused or unfused
Humidity: Less than 90% RH max
(non-condensing) Input line reactor

NEMA 12 Altitude: 3,300 ft. max. Output reactor


ventilated 3 contactor bypass
enclosure Standard Features:
NEMA 12 ventilated enclosure Door mounted operator station
(6 configurations)
with fans and filters
SG Series Sensorless Vector Drive
User terminal strip
Door mounted keypad

Return to the
2-14 benshaw.com Table of Contents
Packaged Drives
SGP Series
Part Number Assembler

SGP 005 2 SD NC A 3B 1 12

SG Built-to-Order Voltage Reactor Options Enclosure


Packaged Drives 2 = 230 V A = No Reactors 12 = NEMA 12 V
4 = 460 V B = Input Reactor
C = Output Reactor
D = Input and Output Reactor

Horsepower
005 = 5 HP Bypass Type
007 = 7.5 HP NN = None
010 = 10 HP 3B = 3 Contactor Bypass
015 = 15 HP
020 = 20 HP
Duty Type Door Mounted Devices
025 = 25 HP
SD = 120% 1 Min. Std. Duty 1 = None
030 = 30 HP
HD = 150% 1 Min. Heavy Duty 2 = Start / Stop PB, Reset PB,
040 = 40 HP HOA Switch, Speed POT
050 = 50 HP 3 = Option 2 Plus Power On,
060 = 60 HP VFD Running, VFD Fault Light
075 = 75 HP 4 = Start / Stop PB, Fault Reset
Disconnect Option PB, HOA Switch, Speed POT,
125 = 125 HP Jog PB, Fwd / Rev Switch,
NC = Non-Combination
VFD Fault Light
CB = Circuit Breaker
5 = VFD / Off / Bypass Switch,
FD = Fusible Disconnect Bypass Running Light
CF = Non-Fused 6 = Start / Stop PB, Reset PB,
Disconnect HOA Switch, Speed POT,
IF = Inline Fuse VFD Running Light, VFD /
Off / Bypass Switch, Bypass
Running Light

Return to the
Table of Contents 2-15
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series
Standard Duty Rated 120% O/L for 1 Minute

230 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number HP A H W D Weight (lbs.) List Price
SGP0072SDXXXXXX12 7.5 22 30 24 16 90 $5,275.00
SGP0102SDXXXXXX12 10 28 30 24 16 93 $5,325.00
SGP0152SDXXXXXX12 15 42 36 30 16 99 $5,545.00
SGP0202SDXXXXXX12 20 54 36 30 16 104 $5,995.00
SGP0252SDXXXXXX12 25 68 36 30 16 110 $6,385.00
SGP0302SDXXXXXX12 30 80 36 30 16 148 $6,745.00
SGP0402SDXXXXXX12 40 104 36 30 16 158 $6,825.00

460 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number HP A H W D Weight (lbs.) List Price
SGP0074SDXXXXXX12 7.5 11 30 24 16 90 $5,295.00
SGP0104SDXXXXXX12 10 14 30 24 16 93 $5,345.00
SGP0154SDXXXXXX12 15 21 30 24 16 99 $5,565.00
SGP0204SDXXXXXX12 20 27 30 24 16 104 $5,965.00
SGP0254SDXXXXXX12 25 34 30 24 16 110 $6,300.00
SGP0304SDXXXXXX12 30 40 36 30 16 148 $6,735.00
SGP0404SDXXXXXX12 40 52 36 30 16 158 $6,825.00
SGP0504SDXXXXXX12 50 65 36 30 16 174 $8,175.00
SGP0604SDXXXXXX12 60 77 36 30 16 174 $9,625.00
SGP0754SDXXXXXX12 75 96 36 30 16 178 $10,525.00
SGP1004SDXXXXXX12 * 100 125 46 30 16 259 $12,425.00
SGP1254SDXXXXXX12 * 125 156 46 30 16 259 $14,355.00
* Dimensions will increase to 70x30x18 for units with three contactor bypass.
Refer to page 2-18 for Disconnect Options, Reactor Options, Bypass Type and Door Mounting Devices

Return to the
2-16 benshaw.com Table of Contents
Packaged Drives
SGP Series
Heavy Duty Rated 150% O/L for 1 Minute

230 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number HP A H W D Weight (lbs.) List Price
SGP0052HDXXXXXX12 5 17 30 24 16 90 $5,275.00
SGP0072HDXXXXXX12 7.5 23 30 24 16 90 $5,325.00
SGP0102HDXXXXXX12 10 33 30 24 16 93 $5,545.00
SGP0152HDXXXXXX12 15 44 36 30 16 99 $5,995.00
SGP0202HDXXXXXX12 20 54 36 30 16 104 $6,385.00
SGP0252HDXXXXXX12 25 68 36 30 16 110 $6,745.00
SGP0302HDXXXXXX12 30 84 36 30 16 148 $6,825.00

460 VAC, 3-Phase Input and Output, 50/60 Hz Input, NEMA 12 Ventilated
Dimensions (in.)
Model Number HP A H W D Weight (lbs.) List Price
SGP0054HDXXXXXX12 5 8 30 24 16 90 $5,295.00
SGP0074HDXXXXXX12 7.5 11 30 24 16 90 $5,345.00
SGP0104HDXXXXXX12 10 14 30 24 16 93 $5,565.00
SGP0154HDXXXXXX12 15 21 30 24 16 99 $5,965.00
SGP0204HDXXXXXX12 20 27 30 24 16 104 $6,300.00
SGP0254HDXXXXXX12 25 34 36 30 16 110 $6,735.00
SGP0304HDXXXXXX12 30 40 36 30 16 148 $6,825.00
SGP0404HDXXXXXX12 40 52 36 30 16 158 $8,175.00
SGP0504HDXXXXXX12 50 65 36 30 16 174 $9,625.00
SGP0604HDXXXXXX12 60 77 36 30 16 174 $10,525.00
SGP0754HDXXXXXX12 * 75 96 46 30 16 178 $12,425.00
SGP1004HDXXXXXX12 * 100 125 46 30 16 259 $14,355.00
* Dimensions will increase to 70x30x18 for units with three contactor bypass.
Refer to page 2-18 for Disconnect Options, Reactor Options, Bypass Type and Door Mounting Devices

Return to the
Table of Contents 2-17
Built-To-Order,
2 Week Shipment
Packaged Drives
SGP Series
Modular Control Options to Customize Your Application
Options CO1 CO2 CO3 CO4 CO5 CO6
Keypad
Start PB
Stop PB
Reset PB
HOA Switch
Speed POT
Run Light
Fault Light
Power On Light
Jog PB
FWD/REV Switch
VFD/OFF Bypass Switch
Bypass Running Light
List Price $125.00 $350.00 $325.00 $550.00 $300.00 $500.00
If selecting a unit with bypass, you must select either option 5 or 6.
Door mounted keypad is standard.

230 VAC Drive Adder


HP CB N-F Disc Fsd Disc Input Fuse In-React Out-React 3-Cnt Bypass
5 $400.00 $235.00 $529.00 $200.00 $259.00 $259.00 $545.00
7.5 $400.00 $235.00 $529.00 $165.00 $259.00 $259.00 $545.00
10 $400.00 $235.00 $529.00 $188.00 $301.00 $301.00 $545.00
15 $450.00 $235.00 $659.00 $214.00 $308.00 $308.00 $823.00
20 $450.00 $235.00 $659.00 $367.00 $327.00 $327.00 $976.00
25 $500.00 $588.00 $1,459.00 $367.00 $414.00 $414.00 $1,129.00
30 $550.00 $588.00 $1,459.00 $416.00 $438.00 $438.00 $1,129.00
40 $850.00 $824.00 $1,471.00 $471.00 $664.00 $664.00 $1,600.00

460 VAC Drive Adder


HP CB N-F Disc Fsd Disc Input Fuse In-React Out-React 3-Cnt Bypass
5 $400.00 $235.00 $412.00 $99.00 $290.00 $290.00 $545.00
7.5 $400.00 $235.00 $412.00 $99.00 $315.00 $315.00 $545.00
10 $400.00 $235.00 $412.00 $99.00 $350.00 $350.00 $545.00
15 $400.00 $235.00 $412.00 $165.00 $400.00 $400.00 $545.00
20 $400.00 $235.00 $494.00 $188.00 $423.00 $423.00 $545.00
25 $400.00 $305.00 $494.00 $200.00 $423.00 $423.00 $640.00
30 $550.00 $305.00 $538.00 $214.00 $490.00 $490.00 $800.00
40 $550.00 $353.00 $720.00 $367.00 $515.00 $515.00 $900.00
50 $550.00 $353.00 $720.00 $367.00 $575.00 $575.00 $1,125.00
60 $550.00 $835.00 $1,212.00 $416.00 $585.00 $585.00 $1,125.00
75 $700.00 $835.00 $1,212.00 $471.00 $795.00 $795.00 $1,570.00
100 $800.00 $950.00 $1,650.00 $682.00 $890.00 $890.00 $1,570.00
125 $1,100.00 $950.00 $1,650.00 $710.00 $1,090.00 $1,090.00 $1,650.00

Return to the
2-18 benshaw.com Table of Contents
Standard Low Voltage Drive Options
Input Line Reactors
3% Impedance

230 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA25L REA-KDRA25L-C1 1 4.6 4 4.18 3.75 6.5 8 6 8 $185.00 $400.00
REA-KDRA27L REA-KDRA27L-C1 2 7.5 4 4.18 3.75 6.5 8 6 8 $200.00 $425.00
REA-KDRA28L REA-KDRA28L-C1 3 10.6 4 4.18 3.75 6.5 8 6 8 $235.00 $445.00
REA-KDRB22L REA-KDRB22L-C1 5 16.7 5 6 4 6.5 8 6 12 $300.00 $525.00
REA-KDRB23L REA-KDRB23L-C2 7.5 24.2 5 6 4 7.5 10 7 14 $325.00 $575.00
REA-KDRD25L REA-KDRD25L-C2 10 30.8 5.75 7.2 4.25 7.5 10 7 18 $355.00 $625.00
REA-KDRD24L REA-KDRD24L-C2 15 46.2 5.75 7.2 4.25 7.5 10 7 18 $445.00 $700.00
REA-KDRD26L REA-KDRD26L-C2 20 59.4 5.75 7.2 4.25 7.5 10 7 18 $475.00 $725.00
REA-KDRC22L REA-KDRC22L-C2 25 74.8 5.75 7.2 5 7.5 10 7 21 $635.00 $885.00
REA-KDRF24L REA-KDRF24L-C4 30 88 7 9 6 15.5 15 13 65 $650.00 $1,255.00
REA-KDRF25L REA-KDRF25L-C4 40 114 7 9 6 15.5 15 13 65 $955.00 $1,565.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
Table of Contents 2-19
Standard Low Voltage
Drive Options
Input Line Reactors
3% Impedance

480 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA8L REA-KDRA8L-C1 1 2.1 4 4.18 3.75 6.5 8 6 8 $185.00 $400.00
REA-KDRA1L REA-KDRA1L-C1 2 3.4 4 4.18 3.75 6.5 8 6 8 $195.00 $410.00
REA-KDRA2L REA-KDRA2L-C1 3 4.8 4 4.18 3.75 6.5 8 6 8 $210.00 $425.00
REA-KDRA3L REA-KDRA3L-C1 5 7.6 4 4.18 3.75 6.5 8 6 8 $225.00 $445.00
REA-KDRA4L REA-KDRA4L-C1 7.5 11 4 4.18 3.75 6.5 8 6 8 $250.00 $465.00
REA-KDRA5L REA-KDRA5L-C1 10 14 4 4.18 3.75 6.5 8 6 9 $315.00 $525.00
REA-KDRB2L REA-KDRB2L-C1 15 21 5 6 4 6.5 8 6 12 $365.00 $585.00
REA-KDRB1L REA-KDRB1L-C1 20 27 5 6 4 6.5 8 6 12 $400.00 $625.00
REA-KDRD1L REA-KDRD1L-C2 25 34 5.75 7.2 4.25 7.5 10 7 16 $425.00 $685.00
REA-KDRD2L REA-KDRD2L-C2 30 40 5.75 7.2 4.25 7.5 10 7 16 $550.00 $795.00
REA-KDRC1L REA-KDRC1L-C2 40 52 5.75 7.2 5 7.5 10 7 21 $595.00 $855.00
REA-KDRF2L REA-KDRF2L-C3 50 65 7 9 6 9 12 8 37 $695.00 $1,065.00
REA-KDRF4L REA-KDRF4L-C3 60 77 7 9 6 9 12 8 42 $725.00 $1,085.00
REA-KDRF3L REA-KDRF3L-C4 75 96 7 9 6 15.5 15 13 65 $955.00 $1,565.00
REA-KDRH3L REA-KDRH3L-C4 100 124 7 9 7 15.5 15 13 65 $1,100.00 $1,725.00
REA-KDRH2L REA-KDRH2L-C4 125 156 9 11 7 15.5 15 13 75 $1,365.00 $1,985.00
REA-KDRH1L REA-KDRH1L-C4 150 180 9 11 7 15.5 15 13 75 $1,600.00 $2,225.00
REA-KDRG3L REA-KDRG3L-C4 200 240 9 11 8 15.5 15 13 100 $2,050.00 $2,650.00
REA-KDRG1L REA-KDRG1L-C4 250 302 9 11 8 15.5 15 13 100 $2,245.00 $2,855.00
REA-KDRG2L REA-KDRG2L-C4 300 361 9 11 8 15.5 15 13 100 $2,295.00 $2,925.00
REA-KDRJ2L REA-KDRJ2L-C5 350 414 9 11 9 18.5 20 16 120 $2,655.00 $3,475.00
REA-KDRJ1L REA-KDRJ1L-C5 400 477 9 11 9 18.5 20 16 120 $2,950.00 $3,750.00
REA-KDRL2L REA-KDRL2L-C5 500 590 11.38 14.5 9.5 18.5 20 16 160 $5,165.00 $5,985.00
REA-KDRL3L REA-KDRL3L-C5 600 720 11.38 14.5 9.5 18.5 20 16 205 $6,545.00 $7,355.00
REA-KDRS1L REA-KDRS1L-C7 700 840 11.38 15 12.5 36 28.5 30.3 318 $7,650.00 $9,785.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
2-20 benshaw.com Table of Contents
Input Line Reactors
3% Impedance

600 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA50L REA-KDRA50L-C1 1 1.7 4 4.18 3.75 6.5 8 6 8 $215.00 $425.00
REA-KDRA46L REA-KDRA46L-C1 2 2.7 4 4.18 3.75 6.5 8 6 8 $225.00 $435.00
REA-KDRA52L REA-KDRA52L-C1 3 3.9 4 4.18 3.75 6.5 8 6 8 $235.00 $450.00
REA-KDRA47L REA-KDRA47L-C1 5 6.1 4 4.18 3.75 6.5 8 6 8 $245.00 $465.00
REA-KDRA48L REA-KDRA48L-C1 7.5 9 4 4.18 3.75 6.5 8 6 8 $285.00 $500.00
REA-KDRA49L REA-KDRA49L-C1 10 11 4 4.18 3.75 6.5 8 6 9 $325.00 $550.00
REA-KDRB45L REA-KDRB45L-C1 15 17 5 6 4 6.5 8 6 12 $365.00 $585.00
REA-KDRB44L REA-KDRB44L-C1 20 22 5 6 4 6.5 8 6 12 $385.00 $600.00
REA-KDRB43L REA-KDRB43L-C1 25 27 5 6 4 6.5 8 6 12 $425.00 $645.00
REA-KDRD42L REA-KDRD42L-C2 30 32 5.75 7.2 4.25 7.5 10 7 18 $435.00 $685.00
REA-KDRC43L REA-KDRC43-C2 40 41 5.75 7.2 5 7.5 10 7 21 $465.00 $725.00
REA-KDRC44L REA-KDRC44L-C2 50 52 5.75 7.2 5 7.5 10 7 21 $495.00 $755.00
REA-KDRF46L REA-KDRF46L-C3 60 62 7 9 6 9 12 8 42 $665.00 $1,025.00
REA-KDRF47L REA-KDRF47L-C3 75 77 7 9 6 9 12 8 42 $695.00 $1,055.00
REA-KDRF45L REA-KDRF45L-C4 100 99 7 9 6 15.5 15 13 65 $955.00 $1,565.00
REA-KDRH43L REA-KDRH43L-C4 125 125 9 11 7 15.5 15 13 80 $1,085.00 $1,700.00
REA-KDRH44L REA-KDRH44L-C4 150 144 9 11 7 15.5 15 13 80 $1,355.00 $1,965.00
REA-KDRI42L REA-KDRI42L-C4 200 192 9 11 7 15.5 15 13 85 $1,445.00 $2,055.00
REA-KDRG47L REA-KDRG47L-C4 250 242 9 11 8 15.5 15 13 100 $1,600.00 $2,225.00
REA-KDRG45L REA-KDRG45L-C4 300 289 9 11 8 15.5 15 13 100 $1,885.00 $2,495.00
REA-KDRJ45L REA-KDRJ45L-C5 350 336 9 11 9 18.5 20 16 120 $2,125.00 $2,925.00
REA-KDRJ43L REA-KDRJ43L-C5 400 382 9 11 9 18.5 20 16 120 $2,250.00 $3,050.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
Table of Contents 2-21
Standard Low Voltage
Drive Options
Input Line Reactors
5% Impedance

240 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA25H REA-KDRA25H-C1 1 4.6 4 4.18 3.75 6.5 8 6 8 $225.00 $435.00
REA-KDRA26H REA-KDRA26H-C1 2 7.5 4 4.18 3.75 6.5 8 6 8 $250.00 $465.00
REA-KDRA28H REA-KDRA28H-C1 3 10.6 4 4.18 3.75 6.5 8 6 8 $275.00 $485.00
REA-KDRB25H REA-KDRB25H-C1 5 16.7 5 6 4 6.5 8 6 12 $345.00 $555.00
REA-KDRB26H REA-KDRB26H-C1 7.5 24.2 5 6 4 6.5 8 6 12 $410.00 $625.00
REA-KDRD21H REA-KDRD21H-C2 10 30.8 5.75 7.2 4.25 7.5 10 7 18 $425.00 $675.00
REA-KDRD22H REA-KDRD22H-C2 15 46.2 5.75 7.2 4.25 7.5 10 7 18 $545.00 $795.00
REA-KDRC22H REA-KDRC22H-C2 20 59.4 5.75 7.2 5 7.5 10 7 21 $615.00 $865.00
REA-KDRF28H REA-KDRF28H-C3 25 74.8 7 9 6 9 12 8 42 $725.00 $1,085.00
REA-KDRF25H REA-KDRF25H-C4 30 88 7 9 6 15.5 15 13 65 $745.00 $1,355.00
REA-KDRF26H REA-KDRF26H-C4 40 114 7 9 6 15.5 15 13 65 $995.00 $1,625.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
2-22 benshaw.com Table of Contents
Input Line Reactors
5% Impedance

480 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA8H REA-KDRA8H-C1 1 2.1 4.00 4.18 3.75 6.5 8 6 8 $215.00 $425.00
REA-KDRA1H REA-KDRA1H-C1 2 3.4 4.00 4.18 3.75 6.5 8 6 8 $225.00 $445.00
REA-KDRA2H REA-KDRA2H-C1 3 4.8 4.00 4.18 3.75 6.5 8 6 8 $285.00 $500.00
REA-KDRA3H REA-KDRA3H-C1 5 7.6 4.00 4.18 3.75 6.5 8 6 8 $325.00 $545.00
REA-KDRA4H REA-KDRA4H-C1 7.5 11 4.00 4.18 3.75 6.5 8 6 9 $375.00 $585.00
REA-KDRA5H REA-KDRA5H-C1 10 14 4.00 4.18 3.75 6.5 8 6 9 $465.00 $675.00
REA-KDRB2H REA-KDRB2H-C1 15 21 5.00 6.00 4.00 6.5 8 6 11 $475.00 $695.00
REA-KDRC3H REA-KDRC3H-C1 20 27 5.75 7.20 5.0 6.5 8 6 19 $535.00 $785.00
REA-KDRC1H REA-KDRC1H-C2 25 34 5.75 7.20 5.0 7.5 10 7 21 $635.00 $895.00
REA-KDRE2H REA-KDRE2H-C2 30 40 5.75 7.20 5.0 7.5 10 7 22 $725.00 $985.00
REA-KDRF4H REA-KDRF4H-C3 40 52 7.00 9.00 6.00 9 12 8 37 $755.00 $1,125.00
REA-KDRF1H REA-KDRF1H-C3 50 65 7.00 9.00 6.00 9 12 8 37 $1,050.00 $1,400.00
REA-KDRF2H REA-KDRF2H-C3 60 77 7.00 9.00 6.00 9 12 8 37 $1,075.00 $1,445.00
REA-KDRH2H REA-KDRH2H-C4 75 96 9.00 11.00 7.00 15.5 15 13 80 $1,225.00 $1,835.00
REA-KDRI2H REA-KDRI2H-C4 100 124 9.00 11.00 7.00 15.5 15 13 87 $1,465.00 $2,075.00
REA-KDRG3H REA-KDRG3H-C4 125 156 9.00 11.00 7.00 15.5 15 13 90 $1,645.00 $2,255.00
REA-KDRG1H REA-KDRG1H-C4 150 180 9.00 11.00 7.00 15.5 15 13 90 $2,000.00 $2,625.00
REA-KDRJ1H REA-KDRJ1H-C5 200 240 9.00 11.00 7.00 18.5 20 16 120 $2,665.00 $3,485.00
REA-KDRL1H REA-KDRL1H-C5 250 302 11.38 14.50 9.50 18.5 20 16 160 $2,915.00 $3,735.00
REA-KDRL2H REA-KDRL2H-C5 300 361 11.38 14.50 9.31 18.5 20 16 145 $2,935.00 $3,750.00
REA-KDRL3H REA-KDRL3H-C5 350 414 11.38 14.50 9.31 18.5 20 16 150 $3,345.00 $4,155.00
REA-KDRL4H REA-KDRL4H-C5 400 477 11.38 14.50 9.50 18.5 20 16 160 $4,425.00 $5,250.00
REA-KDRL5H REA-KDRL5H-C5 450 515 11.38 14.50 11.00 18.5 20 16 165 $4,625.00 $5,435.00
REA-KDRL6H REA-KDRL6H-C5 500 590 11.38 14.50 11.00 18.5 20 16 170 $5,825.00 $6,650.00
REA-KDRS1H REA-KDRS1H-C7 600 720 11.38 15.00 13.00 36 28.5 30.3 420 $7,025.00 $9,075.00
REA-KDRS2H REA-KDRS2H-C7 700 840 11.38 15.00 13.00 36 28.5 30.3 420 $8,195.00 $9,825.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
Table of Contents 2-23
Standard Low Voltage
Drive Options
Input Line Reactors
5% Impedance

600 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA50H REA-KDRA50H-C1 1 1.7 4 4.18 3.75 6.5 8 6 8 $235.00 $445.00
REA-KDRA43H REA-KDRA43H-C1 2 2.7 4 4.18 3.75 6.5 8 6 8 $245.00 $455.00
REA-KDRA44H REA-KDRA44H-C1 3 3.9 4 4.18 3.75 6.5 8 6 8 $255.00 $465.00
REA-KDRA45H REA-KDRA45H-C1 5 6.1 4 4.18 3.75 6.5 8 6 8 $350.00 $565.00
REA-KDRB42H REA-KDRB42H-C2 7.5 9 5 6 4 7.5 10 7 14 $435.00 $695.00
REA-KDRB43H REA-KDRB43H-C2 10 11 5 6 4 7.5 10 7 14 $485.00 $745.00
REA-KDRB44H REA-KDRB44H-C2 15 17 5 6 4 7.5 10 7 14 $500.00 $755.00
REA-KDRD41H REA-KDRD41H-C2 20 22 5.75 7.2 4.25 7.5 10 7 18 $535.00 $785.00
REA-KDRC43H REA-KDRC43H-C2 25 27 5.75 7.2 5 7.5 10 7 21 $575.00 $835.00
REA-KDRE42H REA-KDRE42H-C2 30 32 5.75 7.2 5 7.5 10 7 22 $675.00 $925.00
REA-KDRF44H REA-KDRF44H-C3 40 41 7 9 6 9 12 8 42 $795.00 $1,165.00
REA-KDRF45H REA-KDRF45H-C3 50 52 7 9 6 9 12 8 42 $1,025.00 $1,385.00
REA-KDRH43H REA-KDRH43H-C4 60 62 9 11 6 15.5 15 13 80 $1,095.00 $1,715.00
REA-KDRH42H REA-KDRH42H-C4 75 77 9 11 6 15.5 15 13 80 $1,145.00 $1,755.00
REA-KDRI41H REA-KDRI41H-C4 100 99 9 11 7 15.5 15 13 85 $1,665.00 $2,275.00
REA-KDRG44H REA-KDRG44H-C4 125 125 9 11 7.5 15.5 15 13 100 $1,755.00 $2,365.00
REA-KDRG45H REA-KDRG45H-C4 150 144 9 11 8 15.5 15 13 100 $1,825.00 $2,445.00
REA-KDRJ41H REA-KDRJ41H-C5 200 192 9 11 9 18.5 20 16 120 $2,325.00 $3,145.00
REA-KDRL46H REA-KDRL46H-C5 250 242 11.38 15 11 18.5 20 16 160 $3,265.00 $4,085.00
REA-KDRL47H REA-KDRL47H-C5 300 289 11.38 15 11 18.5 20 16 160 $3,325.00 $4,145.00
REA-KDRL48H REA-KDRL48H-C5 350 336 11.38 15 11 18.5 20 16 160 $3,455.00 $4,255.00
REA-KDRL49H REA-KDRL49H-C5 400 382 11.38 15 11 18.5 20 16 160 $3,555.00 $4,345.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality problems.
They are also required on applications where the transformer impedance exceeds 10 times the kVA rating of the drive.

Return to the
2-24 benshaw.com Table of Contents
Output Reactors
1.5% Impedance

480 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA1P REA-KDRA1P-C1 2 3.4 4 4.18 3.75 8 6.5 8 6 $245.00 $455.00
REA-KDRA2P REA-KDRA2P-C1 3 4.8 4 4.18 3.75 8 6.5 8 6 $295.00 $505.00
REA-KDRA3P REA-KDRA3P-C1 5 7.6 4 4.18 3.75 8 6.5 8 6 $300.00 $515.00
REA-KDRA4P REA-KDRA4P-C1 7.5 11 4 4.18 3.75 9 6.5 8 6 $325.00 $525.00
REA-KDRB1P REA-KDRB1P-C1 10 14 5 6 4 11 6.5 8 6 $425.00 $645.00
REA-KDRD1P REA-KDRD1P-C2 15 21 6 7.2 4.25 16 7.5 10 7 $445.00 $695.00
REA-KDRD2P REA-KDRD2P-C2 20 27 6 7.2 4.25 16 7.5 10 7 $455.00 $725.00
REA-KDRD3P REA-KDRD3P-C2 25 34 6 7.2 4.25 18 7.5 10 7 $475.00 $745.00
REA-KDRD4P REA-KDRD4P-C2 30 40 6 7.2 4.25 18 7.5 10 7 $600.00 $855.00
REA-KDRC1P REA-KDRC1P-C2 40 52 5.75 7.2 5 21 7.5 10 7 $665.00 $925.00
REA-KDRF1P REA-KDRF1P-C3 50 65 7 9 6 37 9 12 8 $775.00 $1,150.00
REA-KDRF2P REA-KDRF2P-C3 60 77 7 9 6 37 9 12 8 $795.00 $1,165.00
REA-KDRF3P REA-KDRF3P-C4 75 96 7 9 6 65 15.5 15 13 $1,065.00 $1,675.00
REA-KDRH1P REA-KDRH1P-C4 100 124 9 11 7 75 15.5 15 13 $1,235.00 $1,845.00
REA-KDRI1P REA-KDRI1P-C4 125 156 9 11 7 85 15.5 15 13 $1,525.00 $2,135.00
REA-KDRI2P REA-KDRI2P-C4 150 180 9 11 7 90 15.5 15 13 $1,785.00 $2,395.00
REA-KDRG1P REA-KDRG1P-C4 200 240 9 11 8 95 15.5 15 13 $2,265.00 $2,875.00
REA-KDRJ1P REA-KDRJ1P-C5 250 302 9 11 9 120 18.5 20 16 $2,495.00 $3,315.00
REA-KDRJ2P REA-KDRJ2P-C5 300 361 9 11 9 120 18.5 20 16 $2,550.00 $3,365.00
REA-KDRL1P REA-KDRL1P-C5 350 414 11.38 14.5 9.31 135 18.5 20 16 $2,950.00 $3,765.00
REA-KDRL2P REA-KDRL2P-C5 400 477 11.38 14.5 9.31 145 18.5 20 16 $3,255.00 $4,075.00
REA-KDRL3P REA-KDRL3P-C5 450 515 11.38 14.5 9.31 150 18.5 20 16 $3,775.00 $4,595.00
REA-KDRL4P REA-KDRL4P-C5 500 590 11.38 14.5 9.31 150 18.5 20 16 $5,745.00 $6,555.00
230 V drives/motors can operate with extended lead lengths (<500 ft.) without a load reactor.
If the installation is >500 ft. or involves multiple motors from one drive, use an appropriately sized (current) 480 V reactor or a long lead filter.

Return to the
Table of Contents 2-25
Standard Low Voltage
Drive Options
Output Reactors
1.5% Impedance

600 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
REA-KDRA31P REA-KDRA31P-C1 2 2.7 4 4.18 3.75 8 6.5 8 6 $285.00 $500.00
REA-KDRA35P REA-KDRA35P-C1 3 3.9 4 4.18 3.75 8 6.5 8 6 $350.00 $565.00
REA-KDRA33P REA-KDRA33P-C1 5 6.1 4 4.18 3.75 8 6.5 8 6 $365.00 $585.00
REA-KDRA34P REA-KDRA34P-C1 7.5 9 4 4.18 3.75 9 6.5 8 6 $425.00 $625.00
REA-KDRA36P REA-KDRA36P-C1 10 11 4 4.18 3.75 9 6.5 8 6 $515.00 $725.00
REA-KDRD31P REA-KDRD31P-C2 15 17 5.75 7.2 4.25 16 7.5 10 7 $525.00 $785.00
REA-KDRD32P REA-KDRD32P-C2 20 22 5.75 7.2 4.25 16 7.5 10 7 $585.00 $845.00
REA-KDRD35P REA-KDRD35P-C2 25 27 5.75 7.2 4.25 16 7.5 10 7 $705.00 $965.00
REA-KDRD33P REA-KDRD33P-C2 30 32 5.75 7.2 4.25 18 7.5 10 7 $805.00 $1,065.00
REA-KDRD34P REA-KDRD34P-C2 40 41 5.75 7.2 4.25 18 7.5 10 7 $825.00 $1,095.00
REA-KDRC31P REA-KDRC31P-C2 50 52 5.75 7.2 5 21 7.5 10 7 $1,155.00 $1,425.00
REA-KDRF31P REA-KDRF31P-C3 60 62 7 9 6 37 9 12 8 $1,195.00 $1,565.00
REA-KDRF32P REA-KDRF32P-C3 75 77 7 9 6 37 9 12 8 $1,355.00 $1,725.00
REA-KDRF33P REA-KDRF33P-C4 100 99 7 9 6 65 15.5 15 13 $1,625.00 $2,245.00
REA-KDRH31P REA-KDRH31P-C4 125 125 9 11 7 75 15.5 15 13 $1,825.00 $1,445.00
REA-KDRI31P REA-KDRI31P-C4 150 144 9 11 7 85 15.5 15 13 $2,235.00 $2,850.00
REA-KDRI32P REA-KDRI32P-C4 200 192 9 11 7 90 15.5 15 13 $2,965.00 $3,585.00
REA-KDRG31P REA-KDRG31P-C4 250 242 9 11 8 95 15.5 15 13 $3,235.00 $3,845.00
REA-KDRJ31P REA-KDRJ31P-C5 300 289 9 11 9 120 18.5 20 16 $3,255.00 $4,075.00
REA-KDRJ32P REA-KDRJ32P-C5 350 336 9 11 9 120 18.5 20 16 $3,725.00 $4,535.00
REA-KDRL31P REA-KDRL31P-C5 400 382 11.38 14.5 9.31 135 18.5 20 16 $4,925.00 $5,750.00

Return to the
2-26 benshaw.com Table of Contents
Long Lead Filters (DV / DT)

240 V
Model Number Open Dimensions (in.) Enclosed Dimensions (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
FLTR-V1K3A00 FLTR-V1K3A01 0.5 3 9.00 5.50 7.25 9 5.5 10 11 $885.00 $1,395.00
FLTR-V1K4A00 FLTR-V1K4A01 0.75 4 9.00 5.50 7.25 9 5.5 10 11 $915.00 $1,400.00
FLTR-V1K6A00 FLTR-V1K6A01 1~1.5 6 9.00 5.50 7.25 9 5.5 10 11 $935.00 $1,425.00
FLTR-V1K8A00 FLTR-V1K8A01 2 8 9.00 5.50 8.25 9 5.5 10 11 $950.00 $1,455.00
FLTR-V1K12A00 FLTR-V1K12A01 3 12 9.00 5.50 8.25 9 5.5 10 11 $985.00 $1,525.00
FLTR-V1K16A00 FLTR-V1K16A01 5 16 9.00 5.50 8.25 9 5.5 10 15 $995.00 $1,545.00
FLTR-V1K25A00 FLTR-V1K25A01 7.5 25 9.00 5.50 8.25 9 5.5 10 15 $1,325.00 $1,725.00
FLTR-V1K35A00 FLTR-V1K35A01 10 35 12.00 8.00 9.00 12 8 11.5 23 $1,435.00 $1,845.00
FLTR-V1K45A00 FLTR-V1K45A01 15 45 12.00 8.00 9.00 12 8 11.5 23 $1,495.00 $1,900.00
FLTR-V1K55A00 FLTR-V1K55A01 20 55 12.00 8.00 9.00 12 8 11.5 23 $1,545.00 $2,075.00
FLTR-V1K80A00 FLTR-V1K80A01 25~30 80 12.00 8.00 9.00 12 8 11.5 29 $2,175.00 $2,705.00
FLTR-V1K110A00 FLTR-V1K110A01 40 110 12.00 8.00 10.25 16.5 18 15 68 $2,555.00 $3,715.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV/DT.

Return to the
Table of Contents 2-27
Standard Low Voltage
Drive Options
Long Lead Filters (DV / DT)
480 V
Open Dimensions Enclosed Dimensions
Model Number (in.) (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
FLTR-V1K2A00 FLTR-V1K2A01 0.75 2 9 5.5 7.25 9 5.5 10 11 $865.00 $1,385.00
FLTR-V1K3A00 FLTR-V1K3A01 1~1.5 3 9 5.5 7.25 9 5.5 10 11 $885.00 $1,395.00
FLTR-V1K4A00 FLTR-V1K4A01 2 4 9 5.5 7.25 9 5.5 10 11 $915.00 $1,400.00
FLTR-V1K6A00 FLTR-V1K6A01 3 6 9 5.5 7.25 9 5.5 10 11 $935.00 $1,425.00
FLTR-V1K8A00 FLTR-V1K8A01 5 8 9 5.5 8.25 9 5.5 10 11 $945.00 $1,445.00
FLTR-V1K12A00 FLTR-V1K12A01 7.5 12 9 5.5 8.25 9 5.5 10 11 $985.00 $1,525.00
FLTR-V1K16A00 FLTR-V1K16A01 10 16 9 5.5 8.25 9 5.5 10 15 $995.00 $1,550.00
FLTR-V1K18A00 FLTR-V1K18A01 10 18 9 5.5 8.25 9 5.5 10 15 $1,095.00 $1,625.00
FLTR-V1K21A00 FLTR-V1K21A01 15 21 9 5.5 8.25 9 5.5 10 15 $1,245.00 $1,685.00
FLTR-V1K25A00 FLTR-V1K25A01 15 25 9 5.5 8.25 9 5.5 10 15 $1,325.00 $1,725.00
FLTR-V1K27A00 FLTR-V1K27A01 20 27 9 5.5 8.25 9 5.5 10 15 $1,375.00 $1,785.00
FLTR-V1K35A00 FLTR-V1K35A01 25 35 12 8 9 12 8 11.5 23 $1,435.00 $1,845.00
FLTR-V1K45A00 FLTR-V1K45A01 30 45 12 8 9 12 8 11.5 23 $1,495.00 $1,905.00
FLTR-V1K55A00 FLTR-V1K55A01 40 55 12 8 9 12 8 11.5 23 $1,545.00 $2,075.00
FLTR-V1K80A00 FLTR-V1K80A01 50~60 80 12 8 9 12 8 11.5 29 $2,175.00 $2,705.00
FLTR-V1K110A00 FLTR-V1K110A01 75 110 12 8 10.25 16.5 18 15 68 $2,555.00 $3,715.00
FLTR-V1K130A00 FLTR-V1K130A01 100 130 8.5 11.75 9.5 16.5 18 15 83 $2,985.00 $4,185.00
FLTR-V1K160A00 FLTR-V1K160A01 125 160 8.5 11.75 10.5 16.5 18 15 83 $3,295.00 $4,495.00
FLTR-V1K200A00 FLTR-V1K200A01 150 200 8.5 11.75 9.25 16.5 18 15 93 $3,585.00 $4,675.00
FLTR-V1K250A00 FLTR-V1K250A01 200 250 8.5 11.75 9.25 16.5 18 15 93 $3,685.00 $4,765.00
FLTR-V1K305A00 FLTR-V1K305A01 250 305 8.75 11.75 12.25 16.5 18 30 117 $4,000.00 $4,795.00
FLTR-V1K362A00 FLTR-V1K362A01 300 362 8.75 11.75 12 16.5 18 30 117 $4,585.00 $5,335.00
FLTR-V1K420A00 FLTR-V1K420A01 350 420 10 11.75 13.75 16.5 18 30 132 $5,315.00 $5,785.00
FLTR-V1K480A00 FLTR-V1K480A01 400 480 10 11.75 13.75 16.5 18 30 138 $5,675.00 $6,485.00
FLTR-V1K600A00 FLTR-V1K600A01 500 600 12.75 15 13.75 16.5 18 30 168 $5,945.00 $7,085.00
FLTR-V1K750A00 FLTR-V1K750A01 600 750 12.75 15 14.5 16.5 18 30 180 $9,695.00 $12,695.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV / DT.

Return to the
2-28 benshaw.com Table of Contents
Long Lead Filters (DV / DT)
600 V
Open Dimensions Enclosed Dimensions
Model Number (in.) (in.)
Weight Open Enclosed
Open Enclosed (NEMA 1) HP A H W D H W D (lbs.) List Price List Price
FLTR-V1K2A00 FLTR-V1K2A01 1 2 9 5.5 7.25 9 5.5 10 11 $865.00 $1,385.00
FLTR-V1K3A00 FLTR-V1K3A01 2 3 9 5.5 7.25 9 5.5 10 11 $885.00 $1,395.00
FLTR-V1K4A00 FLTR-V1K4A01 3 4 9 5.5 7.25 9 5.5 10 11 $915.00 $1,415.00
FLTR-V1K8A00 FLTR-V1K8A01 5 8 9 5.5 8.25 9 5.5 10 11 $945.00 $1,455.00
FLTR-V1K12A00 FLTR-V1K12A01 10 12 9 5.5 8.25 9 5.5 10 11 $985.00 $1,525.00
FLTR-V1K18A00 FLTR-V1K18A01 15 18 9 5.5 8.25 9 5.5 10 15 $1,095.00 $1,625.00
FLTR-V1K25A00 FLTR-V1K25A01 20 25 9 5.5 8.25 9 5.5 10 15 $1,325.00 $1,725.00
FLTR-V1K27A00 FLTR-V1K27A01 25 27 9 5.5 8.25 9 5.5 10 15 $1,375.00 $1,785.00
FLTR-V1K35A00 FLTR-V1K35A01 30 35 12 8 9 12 8 11.5 23 $1,435.00 $1,845.00
FLTR-V1K45A00 FLTR-V1K45A01 40 45 12 8 9 12 8 11.5 23 $1,495.00 $1,905.00
FLTR-V1K55A00 FLTR-V1K55A01 50 55 12 8 9 12 8 11.5 23 $1,545.00 $2,075.00
FLTR-V1K80A00 FLTR-V1K80A01 75 80 12 8 9 12 8 11.5 29 $2,175.00 $2,705.00
FLTR-V1K110A00 FLTR-V1K110A01 100 110 12 8 10.25 16.5 18 15 68 $2,555.00 $3,715.00
FLTR-V1K130A00 FLTR-V1K130A01 125 130 8.5 11.75 9.5 16.5 18 15 83 $2,985.00 $4,185.00
FLTR-V1K160A00 FLTR-V1K160A01 150 160 8.5 11.75 10.5 16.5 18 15 83 $3,295.00 $4,495.00
FLTR-V1K200A00 FLTR-V1K200A01 200 200 8.5 11.75 9.25 16.5 18 15 933 $3,585.00 $4,685.00
FLTR-V1K250A00 FLTR-V1K250A01 250 250 8.5 11.75 9.25 16.5 18 15 93 $3,685.00 $4,765.00
FLTR-V1K305A00 FLTR-V1K305A01 300 305 8.75 11.75 12.25 16.5 18 30 117 $4,015.00 $4,795.00
FLTR-V1K362A00 FLTR-V1K362A01 350 362 8.75 11.75 12 16.5 18 30 117 $4,585.00 $5,345.00
FLTR-V1K420A00 FLTR-V1K420A01 450 420 10 11.75 13.75 16.5 18 30 132 $5,325.00 $5,785.00
Long lead filters should be considered on applications where the cable distance between the motor and the variable frequency drive exceeds 300 feet.
Long lead filters protect the motor from high DV / DT.

Return to the
Table of Contents 2-29
Dynamic Brake Resistors
and Brake Modules

Dynamic brake resistors and modules are used to address over voltage conditions with drives. Over voltage trips occur when the DC bus in
the drive increases to the over voltage trip level. This increase in voltage occurs when the mechanical energy in the motor is converted into
regenerative electrical energy, which is transferred back into the drive (the motor acts like a generator).

Regeneration occurs when: Regeneration can occur on an occasional basis


or periodically (cyclical) depending on the
The deceleration time is too quick
type of load. A dynamic brake module and
The load has high inertia and keeps rotating after the drive output power has decreased resistor are required to be added to the drive
below that of the load (Ex: fly wheels, large fans) to dissipate this excess power. The module
The load is an over hauling load, cyclical or periodic (Ex: pump jack, punch press) and resistor must be sized correctly
When the motor suddenly becomes unloaded (Ex: lumber mill saw applications) depending on the application.

Contact Benshaw for assistance with sizing brake resistors and brake modules.

Return to the
2-30 benshaw.com Table of Contents
Engineered Low Voltage Drive Packages
Overview
Benshaw is a recognized industry leader in the shipment of engineered drives from our state-
of-the-art factory, with dedicated engineering teams and a complete inventory of components
necessary to build engineered solutions for you. Select the enclosure, disconnect, bypass, pilot
devices, control strategy and filters required to meet your most demanding applications.

Control ModificationsWhatever You Specify


Pilot devices, control power transformers, switches, meters,
relays, space heaters, protective devices, PLCs, etc.

Combination Drive Packages To Meet Your Requirements


Circuit breaker protection
Non-fused disconnect protection
Fusible disconnect protection
Flange or rotary handle mechanism
Bypass PackagesTo Fit Your Application
Three contactor
Reduced voltage solid state starters
EnclosuresTo Match Your Environment
Standard designsNEMA 1, 12, 3R
Custom enclosures
Special enclosures4, 4X, air conditioned
Motor control centers
FiltersFor Your Unique Application
Line reactors 3% and 5%
Long lead filters
Load reactors
Harmonic filters
18 pulse systems

Benshaw builds customized


engineered solutions
to meet your most
demanding applications.

Return to the
Table of Contents 2-31 2-31
Engineered Low
Voltage Drive Products
VFD Pre-Order Check List
2
Purchaser Information
1 Transformer
3 Company Name_______________________________________________________________________

Contact Person________________________________________________________________________
Other Loads MCC
Email_________________________________________________________________________________
7
4 Address ______________________________________________________________________________
Enclosure 16
Phone Number________________________________________________________________________
L
17 5

19
Fuse
Supply
Incoming
r 1 Primary (Input) Volts _____ VAC
_____KVA _____% Impedance
6 Short Circuit Capability _____ ISC (Amps)
Secondary (Output) Volts _____
WYE-Delta Connection: Yes No
7
Grounded Ungrounded
PCC (Point
of Common
r 2 Harmonic Restrictions at PCC: Yes No

Coupling) IEEE 519-1992


VFD
B+ RSi Other Connected Loads Present?
9
B-
DBR
Other Connected
Loads r 3 Please list in detail in comments.
Ex. PFCC, VFD, etc.
Yes No
8
Feeder Cable r 4 Cable Length _____ Conduit Teck
Non-
Shielded
Shielded
10
Main Disconnect r 5 Breaker Fusible Disc. Line Fuses
KAIC Rating
_____

MECH.
INTERLOCK
Input Isolation
Contactor r 6 Yes No HP Rated
NEMA
Rated
11
Input Line Reactor

12
Harmonic
Suppression r 7
3 or 5 % Imp.
Transformer Passive Filter
Active
Filter
18 Pulse RFI/EMI Filter

T VFD Ratings r 8
VFD - HP _____ KVA _____ KW _____
V _____
CT VT Volts _____
Amps _____
Model - RSi - _____ HP - _____ V - _____ Encl.
13 Dynamic Braking r 9 Load Type: Decel Only Overhauling
Duty Cycle 5% 10% 25%
50% 100%

MOTOR
Output Filter r10 Reactor Long Lead Sine Wave
50 ft. ~ 300 ft. 300 ft. ~ 1500 ft. > 1500 ft.
14
Bypass r11 2 Contactor 3 Contactor RVSS HP Rated
NEMA Rated IEC Rated

LOAD
Overload r12 For ATL Bypass only: Class 1-40 _____

20 21

Return to the
2-32 benshaw.com Table of Contents
VFD Pre-Order Check List
Cable Length rSee r
13 10 Manufacturer _______________________
Length _____ Ft _____ M _____
Cable Specification: Non-Shielded Shielded Conduit

Motor Name
Plate Data
r
14 Manufacturer _________________________
HP _____________ Volts ________________
RPM _______ FLA _______ S.F. __________
Amps ________ KVA/Code_____________
Design____________ Frame_____________
Breakdown torque _______% _______lb-ft
Temperature Rise ___________________C
Critical speed ____________________ RPM
Insulation VFD Grade NEMA MG 1 -1998,
Part 3 1.4.4.2
Yes No; See r
10

Over temperature protection: Thermostat Thermistor


RTD and type 100 Pt 10 Cu 100 Ni 20 Ni
Does the motor require a blower for low speed operation? Yes No
Insulated Bearing(s) Yes No
Options r
15 Start P/B Local/Remote Sw.
Stop P/B Pilot Lights
Emergency Stop P/B - Run/Stop
HOA Switch - Forward/Reverse
Forward P/B - Jog
Reverse P/B - Power
Jog Forward P/B - Fault
Jog Reverse P/B
Potentiometer
Fault Reset P/B
Other____________________________________________
Enclosure r
16 UL Type ________ (1, 12, 3R, 4, 4X)
Ambient temperature range _____C to _____C
Altitude 0 to 3,300 ft. (1,000m) Other ________________
Cable Entry/Exit Locations __________________
Enclosure Size
H ________ W _________ D __________
Restrictions
Description ____________________________________________________________________
Control r
17 Keypad Multi-Motor
Terminal Master Follower
0 to 5 VDC Analog Outputs
0 to 10 VDC Analog Inputs
10 VDC Digital Inputs
0/4 to 20 mA Relay Outputs

Return to the
Table of Contents 2-33
Engineered Low
Voltage Drive Products
VFD Pre-Order Check List
VFD Pre-Order Check List (continued)

Communications r18 DeviceNet ModBus RTU


Profibus Other _______________
Moters r19 Motor Amps ______ Motor Volts ____________
Frequency ________ RPM __________________
Other (Please Specify) ______________________
Application Standard-Duty Variable
Details r20
Constant Torque
(150% for 60s)
Torque (120%
for 60s)
Torque (110%
for 60s)
Load-Steady Pulsing Regenerative
Speed Range _______ to _______ RPM
Load Flywheel Inertia (WK)
Load Torque Profile
Breakaway Torque lb.-ft.
Breakaway Torque Duration _______ sec.
Max. Peak Torque _______ lb.-ft.
Accel. Time _______ Decel. Time _______
Torque vs. Speed Curve
Deceleration: Coast Ramp DC Injection
Pump/Fan
Speed _______ Min. Speed _______ Starting and stopping cycle (details) _______________________________________
Holding Brake required? Yes No
Load Details r21 Fan Fin Fan Cooler Cooling Tower Fan
Centrifugal Centrifugal Electrical Submersible
Pump PD Pump Slurry Pump
Pump Compressor Pump (ESP)
Oil Pump Pumpjack (PG) Progressive Cavity Screw Pump (PCP)
Screw Belt Bucket Air
Conveyor Flat Conveyor
Conveyor Conveyor Conveyor Conveyor
Single Dual
Extruder Piston Extruder
Extruder Extruder
Number
Other Centrifuge Canter Line
Throws
Step-up
KVA Vprim Vsec VZ
Transformer:
Gear ratio/Sheave ratio (Motor RPM/Load RPM) _____:_____ Single-phase input

Additional Comments:______________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________

__________________________________________________________________________________________________________________________________

Return to the
2-34 benshaw.com Table of Contents
Sensorless Vector Drives
Engineered Packages
Part Number Assembler

RSI 060 SG 4 NC A 01

VFD VFD Series Package Type


RSI = RediStart SG = Sensorless A = Packaged Drive,
Inverter Vector Drive No Bypass
S4 = Washdown C = Packaged Drive with
Sensorless Three Contactor Bypass
Vector Drive
SS = Packaged Drive with
Horsepower Soft Starter (RVSS)
1 = 1 HP Bypass**
Voltage
2 = 2 HP
2 = 230 V
3 = 3 HP
4 = 460 V
5 = 5 HP
6 = 600 V
7 = 7.5 HP
10 = 10 HP
Disconnect Options Enclosure**
15 = 15 HP
NC = Non-Combination 1/12 = NEMA 1/12
20 = 20 HP
CB = Circuit Breaker 4 = NEMA 4*
25 = 25 HP
FD = Fusible Disconnect** 3R = NEMA 3R
30 = 30 HP
40 = 40 HP
50 = 50 HP
60 = 60 HP
75 = 75 HP
100 = 100 HP
125 = 125 HP
150 = 150 HP
200 = 200 HP
250 = 250 HP
300 = 300 HP
400 = 400 HP
500 = 500 HP
600 = 600 HP
700 = 700 HP

* Air conditioning required.


** Consult factory.

Return to the
Table of Contents 2-35
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series
Enclosed Drives Non-Combination Sensorless Vector Drives 230 V

7.540 HP / NEMA 1 and 3R


Variable Torque Standard Duty Heavy Duty
Model Number HP Amps HP Amps HP Amps A-1A C-1A A-3R C-3R
RSI-007-SG2-NC-XX 7.5 22 7.5 22 5 15.2 $6,200.00 $6,550.00 $6,255.00 $6,535.00
RSI-010-SG2-NC-XX 10 29 10 29 7.5 22 $6,295.00 $6,655.00 $6,745.00 $7,100.00
RSI-015-SG2-NC-XX 15 42 15 42 10 28 $6,595.00 $7,000.00 $7,395.00 $7,825.00
RSI-020-SG2-NC-XX 20 54 20 54 15 42 $7,050.00 $7,555.00 $7,865.00 $8,355.00
RSI-025-SG2-NC-XX 25 68 25 68 20 54 $7,575.00 $8,275.00 $8,375.00 $9,065.00
RSI-030-SG2-NC-XX 30 80 30 80 25 68 $7,925.00 $8,795.00 $8,725.00 $9,595.00
RSI-040-SG2-NC-XX 40 104 40 104 30 80 $8,300.00 $9,385.00 $9,100.00 $10,185.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-50.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
2-36 benshaw.com Table of Contents
Sensorless Vector Drives
SG Series
Enclosed Drives Non-Combination Sensorless Vector Drives 460 V

7.5700 HP / NEMA 1 and 3R


Variable Torque Standard Duty Heavy Duty
Model Number HP Amps HP Amps HP Amps A-1A C-1A A-3R C-3R
RSI-007-SG4-NC-XX 7.5 11 7.5 11 5 8 $6,235.00 $6,495.00 $6,685.00 $6,950.00
RSI-010-SG4-NC-XX 10 14 10 14 7.5 11 $6,295.00 $6,575.00 $6,745.00 $7,050.00
RSI-015-SG4-NC-XX 15 21 15 21 10 14 $6,555.00 $6,950.00 $7,395.00 $7,745.00
RSI-020-SG4-NC-XX 20 27 20 27 15 21 $7,000.00 $7,400.00 $7,865.00 $8,205.00
RSI-025-SG4-NC-XX 25 34 25 34 20 27 $7,455.00 $7,825.00 $8,255.00 $8,625.00
RSI-030-SG4-NC-XX 30 40 30 40 25 34 $7,925.00 $8,355.00 $8,725.00 $9,155.00
RSI-040-SG4-NC-XX 40 52 40 52 30 40 $8,300.00 $8,795.00 $9,100.00 $9,595.00
RSI-050-SG4-NC-XX 50 65 50 65 40 52 $9,845.00 $10,525.00 $10,645.00 $11,345.00
RSI-060-SG4-NC-XX 60 77 60 77 50 65 $11,694.00 $12,625.00 $12,550.00 $13,485.00
RSI-075-SG4-NC-XX 75 96 75 96 60 77 $12,365.00 $13,525.00 $13,225.00 $14,385.00
RSI-100-SG4-NC-XX 100 125 100 125 75 96 $13,665.00 $15,395.00 $14,445.00 $16,185.00
RSI-125-SG4-NC-XX 125 156 125 156 100 125 $15,145.00 $19,765.00 $15,935.00 $18,335.00
RSI-150-SG4-NC-XX 150 180 150 180 125 156 $24,325.00 $27,825.00 $24,915.00 $24,875.00
RSI-200-SG4-NC-XX 200 240 200 240 150 180 $25,995.00 $30,000.00 $26,575.00 $32,425.00
RSI-250-SG4-NC-XX 250 302 250 302 200 240 $28,425.00 $33,000.00 $29,475.00 $34,775.00
RSI-350-SG4-NC-XX 350 414 350 361 250 302 $39,650.00 $44,615.00 $40,685.00 $45,665.00
RSI-400-SG4-NC-XX 400 477 400 477 300 361 $46,675.00 $54,925.00 $47,725.00 $55,975.00
RSI-500-SG4-NC-XX 500 590 500 515 350 414 $58,145.00 $69,675.00 $59,665.00 $62,205.00
RSI-600-SG4-NC-XX 600 731 600 590 400 477 $65,815.00 $77,625.00 $69,700.00 $79,145.00
RSI-700-SG4-NC-XX 700 877 700 804 500 590 $75,145.00 $118,825.00 $76,655.00 $120,945.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-50.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
Table of Contents 2-37
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series
Enclosed Drives Combination Circuit Breaker Sensorless Vector Drives 230 V

7.540 HP / NEMA 1 and 3R


Variable Torque Standard Duty Heavy Duty
Model Number HP Amps HP Amps HP Amps A-1A C-1A A-3R* C-3R*
RSI-007-SG2-CB-XX 7.5 22 7.5 22 5 15.2 $6,555.00 $6,840.00 $7,000.00 $7,295.00
RSI-010-SG2-CB-XX 10 28 10 28 7.5 22 $6,625.00 $7,145.00 $7,075.00 $7,445.00
RSI-015-SG2-CB-XX 15 42 15 42 10 28 $6,945.00 $7,365.00 $7,735.00 $8,165.00
RSI-020-SG2-CB-XX 20 54 20 54 15 42 $7,455.00 $7,950.00 $8,255.00 $8,750.00
RSI-025-SG2-CB-XX 25 68 25 68 20 54 $7,965.00 $8,665.00 $8,775.00 $9,465.00
RSI-030-SG2-CB-XX 30 80 30 80 25 68 $8,500.00 $9,375.00 $9,300.00 $10,175.00
RSI-040-SG2-CB-XX 40 104 40 104 30 80 $9,100.00 $10,185.00 $9,900.00 $10,985.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
*Units should be mounted out of direct sunlight
For dimensions refer to page 2-50.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
2-38 benshaw.com Table of Contents
Sensorless Vector Drives
SG Series
Enclosed Drives Combination Circuit Breaker Sensorless Vector Drives 460 V

7.5700 HP / NEMA 1 and 3R


Variable Torque Standard Duty Heavy Duty
Model Number HP Amps HP Amps HP Amps A-1A C-1A A-3R* C-3R*
RSI-007-SG4-CB-XX 7.5 11 7.5 11 5 8 $6,535.00 $6,795.00 $6,985.00 $7,250.00
RSI-010-SG4-CB-XX 10 14 10 14 7.5 11 $6,595.00 $6,885.00 $7,045.00 $73,959.00
RSI-015-SG4-CB-XX 15 21 15 21 10 14 $6,895.00 $7,245.00 $7,695.00 $8,045.00
RSI-020-SG4-CB-XX 20 27 20 27 15 21 $7,355.00 $7,745.00 $8,195.00 $8,545.00
RSI-025-SG4-CB-XX 25 34 25 34 20 27 $7,795.00 $8,165.00 $8,595.00 $8,955.00
RSI-030-SG4-CB-XX 30 40 30 40 25 34 $8,265.00 $8,685.00 $9,065.00 $9,495.00
RSI-040-SG4-CB-XX 40 52 40 52 30 40 $8,695.00 $9,195.00 $9,495.00 $9,985.00
RSI-050-SG4-CB-XX 50 65 50 65 40 52 $10,250.00 $10,935.00 $11,050.00 $11,735.00
RSI-060-SG4-CB-XX 60 77 60 77 50 65 $12,315.00 $13,245.00 $13,165.00 $14,100.00
RSI-075-SG4-CB-XX 75 96 75 96 60 77 $13,685.00 $14,845.00 $14,545.00 $15,700.00
RSI-100-SG4-CB-XX 100 125 100 125 75 96 $14,975.00 $16,725.00 $15,765.00 $17,500.00
RSI-125-SG4-CB-XX 125 156 125 156 100 125 $16,465.00 $18,855.00 $17,255.00 $19,650.00
RSI-150-SG4-CB-XX 150 180 150 180 125 156 $25,895.00 $29,385.00 $23,365.00 $28,050.00
RSI-200-SG4-CB-XX 200 240 200 240 150 180 $27,555.00 $31,600.00 $28,145.00 $33,995.00
RSI-250-SG4-CB-XX 250 302 250 302 200 240 $30,735.00 $34,695.00 $31,785.00 $37,085.00
RSI-350-SG4-CB-XX 350 414 300 361 250 302 $42,350.00 $49,465.00 $43,395.00 $50,525.00
RSI-400-SG4-CB-XX 400 477 400 477 300 361 $50,445.00 $60,825.00 $51,495.00 $61,875.00
RSI-500-SG4-CB-XX 500 590 450 515 350 414 $61,500.00 $74,385.00 $63,050.00 $75,900.00
RSI-600-SG4-CB-XX 600 731 500 590 400 477 $72,600.00 $83,225.00 $74,125.00 $84,735.00
RSI-700-SG4-CB-XX 700 877 600 804 500 590 $81,935.00 $125,185.00 $87,445.00 $126,885.00
A-1A = VFD in fan and filtered enclosure.
C-1A = VFD in fan and filtered enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
*Units should be mounted out of direct sunlight
For dimensions refer to page 2-50.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

2-39
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
S4 Series
Enclosed Drives Non-Combination Severe Duty Sensorless Vector Drives 230 V

120 HP / NEMA 12 and 3R


Standard Duty Heavy Duty
Model Number HP Amps HP Amps A-12 C-12 A-3R C-3R
RSI-001-S42-NC-XX 1 7.6 - - $7,225.00 $7,500.00 $7,665.00 $7,965.00
RSI-002-S42-NC-XX 2 11 1 7.6 $7,395.00 $7,675.00 $7,845.00 $8,145.00
RSI-003-S42-NC-XX 3 14 2 11 $7,425.00 $7,725.00 $7,875.00 $8,175.00
RSI-005-S42-NC-XX 5 21 3 14 $7,735.00 $8,025.00 $8,185.00 $8,495.00
RSI-007-S42-NC-XX 7.5 27 5 21 $7,845.00 $8,145.00 $8,295.00 $8,565.00
RSI-010-S42-NC-XX 10 34 7.5 27 $9,100.00 $9,465.00 $9,555.00 $9,925.00
RSI-015-S42-NC-XX 15 40 10 34 $9,400.00 $9,825.00 $10,200.00 $10,645.00
RSI-020-S42-NC-XX 20 52 15 40 $11,485.00 $11,975.00 $12,285.00 $12,775.00
A-12 = VFD in NEMA 1 enclosure.
C-12 = VFD in NEMA 1 enclosure with three contactor bypass circuit.
A-3R = VFD in fan and filtered enclosure.
C-3R = VFD in fan and filtered enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
2-40 benshaw.com Table of Contents
Sensorless Vector Drives
S4 Series
Enclosed Drives Non-Combination Severe Duty Sensorless Vector Drives 460 V

1200 HP / NEMA 12 and 3R


Standard Duty Heavy Duty
Model Number HP Amps HP Amps A-12 C-12 A-3R C-3R
RSI-001-S44-NC-XX 1 2.1 - - $7,275.00 $7,545.00 $7,725.00 $7,985.00
RSI-002-S44-NC-XX 2 3.4 1 2.1 $7,425.00 $7,685.00 $7,875.00 $8,135.00
RSI-003-S44-NC-XX 3 4.8 2 3.4 $7,495.00 $7,695.00 $7,875.00 $8,195.00
RSI-005-S44-NC-XX 5 7.6 3 4.8 $7,775.00 $8,035.00 $8,225.00 $8,495.00
RSI-007-S44-NC-XX 7.5 11 5 7.6 $7,845.00 $8,100.00 $8,295.00 $8,555.00
RSI-010-S44-NC-XX 10 14 7.5 11 $7,895.00 $8,150.00 $8,315.00 $8,595.00
RSI-015-S44-NC-XX 15 21 10 14 $9,245.00 $9,635.00 $10,085.00 $10,425.00
RSI-020-S44-NC-XX 20 27 15 21 $9,285.00 $9,665.00 $10,125.00 $10,465.00
RSI-025-S44-NC-XX 25 34 20 27 $9,525.00 $9,885.00 $10,325.00 $10,685.00
RSI-030-S44-NC-XX 30 40 25 34 $9,665.00 $10,095.00 $10,465.00 $10,895.00
RSI-040-S44-NC-XX 40 52 30 40 $12,595.00 $13,085.00 $13,385.00 $13,885.00
RSI-050-S44-NC-XX 50 65 40 52 $12,955.00 $13,650.00 $13,755.00 $14,445.00
RSI-060-S44-NC-XX 60 77 50 65 $17,375.00 $18,245.00 $18,175.00 $19,045.00
RSI-075-S44-NC-XX 75 96 60 77 $17,645.00 $18,725.00 $18,445.00 $19,525.00
RSI-100-S44-NC-XX 100 124 75 96 $20,200.00 $21,825.00 $20,945.00 $22,565.00
RSI-125-S44-NC-XX 125 156 100 124 $25,375.00 $27,615.00 $26,115.00 $26,275.00
RSI-150-S44-NC-XX 150 180 125 156 $29,175.00 $32,050.00 $29,655.00 $34,015.00
RSI-200-S44-NC-XX 200 240 150 180 $29,925.00 $33,255.00 $30,400.00 $35,225.00
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
Table of Contents 2-41
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
S4 Series
Enclosed Drives Combination Circuit Breaker Severe Duty Sensorless Vector
Drives 230 V
120 HP / NEMA 12 and 3R
Standard Duty Heavy Duty
Model Number HP Amps HP Amps A-12 C-12 A-3R C-3R
RSI-001-S42-CB-XX 1 7.6 - - $7,515.00 $7,800.00 $7,665.00 $8,255.00
RSI-002-S42-CB-XX 2 11 1 7.6 $7,695.00 $7,975.00 $8,145.00 $8,425.00
RSI-003-S42-CB-XX 3 14 2 11 $7,725.00 $8,095.00 $8,195.00 $8,465.00
RSI-005-S42-CB-XX 5 21 3 14 $8,050.00 $8,325.00 $8,485.00 $8,775.00
RSI-007-S42-CB-XX 7.5 27 5 21 $8,135.00 $8,415.00 $8,595.00 $8,865.00
RSI-010-S42-CB-XX 10 34 7.5 27 $9,445.00 $9,800.00 $9,885.00 $10,255.00
RSI-015-S42-CB-XX 15 40 10 34 $9,735.00 $10,165.00 $10,555.00 $10,965.00
RSI-020-S42-CB-XX 20 52 15 40 $11,875.00 $12,625.00 $12,675.00 $13,175.00
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
2-42 benshaw.com Table of Contents
Sensorless Vector Drives
S4 Series
Enclosed Drives Combination Circuit Breaker Severe Duty Sensorless Vector
Drives 460 V
1200 HP / NEMA 12 and 3R
Standard Duty Heavy Duty
Model Number HP Amps HP Amps A-12 C-12 A-3R C-3R
RSI-001-S44-CB-XX 1 2.1 - - $7,575.00 $7,845.00 $8,025.00 $8,285.00
RSI-002-S44-CB-XX 2 3.4 1 2.1 $7,725.00 $7,985.00 $8,175.00 $8,435.00
RSI-003-S44-CB-XX 3 4.8 2 3.4 $7,795.00 $7,995.00 $8,195.00 $8,495.00
RSI-005-S44-CB-XX 5 7.6 3 4.8 $8,075.00 $8,335.00 $8,525.00 $8,785.00
RSI-007-S44-CB-XX 7.5 11 5 7.6 $8,145.00 $8,425.00 $8,595.00 $8,855.00
RSI-010-S44-CB-XX 10 14 7.5 11 $8,195.00 $8,450.00 $8,625.00 $8,895.00
RSI-015-S44-CB-XX 15 21 10 14 $9,545.00 $9,935.00 $10,385.00 $10,735.00
RSI-020-S44-CB-XX 20 27 14 21 $9,625.00 $10,000.00 $10,465.00 $10,805.00
RSI-025-S44-CB-XX 25 34 20 27 $9,855.00 $10,225.00 $10,695.00 $11,025.00
RSI-030-S44-CB-XX 30 40 25 34 $10,000.00 $10,425.00 $10,800.00 $11,225.00
RSI-040-S44-CB-XX 40 52 30 40 $12,985.00 $13,475.00 $13,785.00 $14,275.00
RSI-050-S44-CB-XX 50 65 40 52 $13,350.00 $14,050.00 $14,150.00 $14,845.00
RSI-060-S44-CB-XX 60 77 50 65 $17,950.00 $18,825.00 $18,750.00 $19,625.00
RSI-075-S44-CB-XX 75 96 60 77 $18,875.00 $19,955.00 $19,675.00 $20,755.00
RSI-100-S44-CB-XX 100 124 75 96 $21,435.00 $23,050.00 $22,175.00 $23,795.00
RSI-125-S44-CB-XX 125 156 100 124 $26,625.00 $28,845.00 $27,345.00 $29,585.00
RSI-150-S44-CB-XX 150 180 125 156 $30,465.00 $33,350.00 $30,945.00 $35,300.00
RSI-200-S44-CB-XX 200 240 150 180 $31,250.00 $34,545.00 $31,695.00 $36,500.00
Dashes are shown for clarity.
A-12 = VFD in NEMA 12 enclosure.
C-12 = VFD in NEMA 12 enclosure with three contactor bypass circuit.
A-3R = VFD in NEMA 3R enclosure.
C-3R = VFD in NEMA 3R enclosure with three contactor bypass circuit.
For dimensions refer to page 2-51.
For options refer to pages 2-44 2-49.

Variable Torque = 110% current for 1 minute.

Standard Duty = 120% current for 1 minute.

Heavy Duty = 150% current for 1 minute.

Return to the
Table of Contents 2-43
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options Pilot Devices
Push-Buttons
Model Number Description List Price
A001 Raised Stop Push-Button - Red $85.00
A002 Flush Start Push-Button - Green $85.00
A003 Jog Push-Button - Yellow $85.00
A004 Ol Reset Push-Button - (For External Ol Relay) - Black $85.00
A005 Reset Push-Button - Black $85.00
A006 Raised Push-Button - Specify Color and Function $85.00
A007 Flush Push-Button - Specify Color and Function $95.00
A008 Mushroom Head Stop Push-Button - Red $125.00
A009 Illuminated Push-Button - Specify Color and Function $175.00

Pilot Lights
Model Number Description List Price
A021 Red Run Light $125.00
A022 Green Stop Light $125.00
A023 Amber Fault Light $125.00
A024 Green Ready Light $125.00
A025 Amber Bypass Light $125.00
A026 Red Light - Specify Function $145.00
A027 Green Light - Specify Function $145.00
A028 Amber Light - Specify Function $145.00
A029 White Light - Specify Function $145.00
A030 Blue Light - Specify Function $145.00
A031 Push to Test Contact Assembly (Addition to Above) $200.00
A032 Power On Light - White $175.00

Selector Switches
Model Number Description List Price
A041 Hand - Off - Auto Selector Switch $175.00
A042 Local - Off - Remote Selector Switch $175.00
A043 Key Operated Hand - Off - Auto Selector Switch $225.00
A045 Two Postion Selector Switch - Specify Function $195.00
A046 Three Position Selector Switch - Specify Function $250.00
A047 Other Selector Switch - Specify Function and Type

Meters
Model Number Description List Price
A061 Single Phase Analog Ammeter - Includes CTs * $300.00
A062 Analog Ammeter with Three Phase Selector Switch - $300.00
Includes CTs *
A065 Elapsed Time Meter $475.00
A069 Other Power Metering - Specify Function $475.00
* Switchboard type

Space Heaters
Model Number Description List Price
A171 Space Heater with Thermostat $450.00
Consult factory

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
2-44 benshaw.com Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options Line Reactors (Installed)
230 V - Input 3% AC Line Reactors
Model Number HP Volt List Price
A500 1 230 $315.00
A501 2 230 $325.00
A502 3 230 $350.00
A503 5 230 $425.00
A504 7.5 230 $475.00
A505 10 230 $495.00
A506 15 230 $500.00
A507 20 230 $525.00
A508 25 230 $695.00
A509 30 230 $700.00

230 V - Input 5% AC Line Reactors


Model Number HP Volt List Price
A570 1 230 $325.00
A571 2 230 $350.00
A572 3 230 $365.00
A573 5 230 $425.00
A574 7.5 230 $435.00
A575 10 230 $450.00
A576 15 230 $550.00
A577 20 230 $625.00
A578 25 230 $750.00
A579 30 230 $775.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
Table of Contents 2-45
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options Line Reactors (Installed)
460 V - Input 3% AC Line Reactors
Model Number HP Volt List Price
A520 2 460 $195.00
A521 3 460 $235.00
A522 5 460 $255.00
A523 7.5 460 $285.00
A524 10 460 $365.00
A525 15 460 $375.00
A526 20 460 $415.00
A527 25 460 $475.00
A528 30 460 $550.00
A529 40 460 $595.00
A530 50 460 $735.00
A531 60 460 $815.00
A532 75 460 $925.00
A533 100 460 $1,025.00
A534 125 460 $1,395.00
A535 150 460 $1,550.00
A536 200 460 $2,000.00
A537 250 460 $2,200.00
A538 300 460 $2,300.00
A539 350 460 $2,495.00
A540 400 460 $3,325.00
A541 500 460 $4,125.00
A542 600 460 $5,225.00
A543 700 460 $6,125.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
2-46 benshaw.com Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options Line Reactors (Installed)
460 V - Input 5% AC Line Reactors
Model Number HP Volt List Price
A600 2 460 $325.00
A601 3 460 $375.00
A602 5 460 $395.00
A603 7.5 460 $425.00
A604 10 460 $465.00
A605 15 460 $475.00
A606 20 460 $550.00
A607 25 460 $625.00
A608 30 460 $695.00
A609 40 460 $775.00
A610 50 460 $975.00
A611 60 460 $995.00
A612 75 460 $1,300.00
A613 100 460 $1,450.00
A614 125 460 $1,595.00
A615 150 460 $1,825.00
A616 200 460 $2,350.00
A617 250 460 $2,495.00
A618 300 460 $2,595.00
A619 350 460 $2,900.00
A620 400 460 $3,595.00
A621 500 460 $4,675.00
A622 600 460 $5,695.00
A623 700 460 $6,555.00
Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
Table of Contents 2-47
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
Variable Frequency Drive Options Long Lead Filters (Installed)
460 V - Input 5% AC Line Reactors
Model Number HP Volt List Price
A640 1 460 $945.00
A641 2 460 $950.00
A642 3 460 $975.00
A643 5 460 $995.00
A644 7.5 460 $1,100.00
A645 10 460 $1,125.00
A646 15 460 $1,200.00
A647 20 460 $1,295.00
A648 25 460 $1,350.00
A649 30 460 $1,395.00
A650 40 460 $1,425.00
A651 50 - 60 460 $1,895.00
A652 75 460 $2,500.00
A653 100 460 $2,825.00
A654 125 460 $3,000.00
A655 150 460 $3,200.00
A656 200 460 $3,250.00
A657 250 460 $3,300.00
A658 300 460 $3,650.00
A659 350 460 $3,925.00
A660 400 460 $4,400.00
A661 500 460 $9,000.00
A662 600 460
A663 700 460
Line reactors reduce harmonics and protect the variable frequency drive from input power quality
problems. They are also recommended on applications where the transformer impedance exceeds
10 times the KVA rating of the drive.
Consult factory

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
2-48 benshaw.com Table of Contents
Sensorless Vector Drives
Variable Frequency Drive Options
Fast Acting Semiconductor Fuses
HP
Model Number 208V 240V 460V 575V List Price
A670 2 3 5 7.5 $350.00
A671 3 - 7.5 10 $350.00
A672 - 5 10 15 $350.00
A673 5 7.5 15 20 $395.00
A674 7.5 10 20 25 $395.00
A675 10 - 25 30 $395.00
A676 - 15 30 40 $395.00
A677 15 20 40 50 $495.00
A678 20 25 50 60 $495.00
A679 25 30 60 75 $495.00
A680 30 40 75 100 $550.00
A681 40 50 100 125 $550.00
A682 40 60 125 150 $695.00
A683 60 75 150 200 $695.00
A684 75 100 200 250 $695.00
A685 100 125 250 300 $1,000.00
A686 125 150 300 400 $1,495.00
A686 150 200 400 500 $1,495.00
A687 200 250 500 600 $1,495.00
A688 250 300 600 700 $1,750.00
A689 300 350 700 -
NOTE: This option adds fast acting semiconductor fuses to the input of the VFD.
Consult factory

FOR ADDITIONAL OPTIONS - CONTACT FACTORY

Return to the
Table of Contents 2-49
Engineered Low
Voltage Drive Products
Sensorless Vector Drives
SG Series Dimensions

230 V
Enclosure Dimensions
With Circuit Breaker 3-Contactor Bypass
HP No Options or Line Reactor 3-Contactor Bypass & Circuit Breaker
7.5 30x24x16 30x24x16 30x24x16 30x24x16
10 30x24x16 30x24x16 30x24x16 30x24x16
15 30x24x16 30x24x16 30x24x16 30x24x16
20 30x24x16 30x24x16 30x24x16 30x24x16
25 30x24x16 30x24x16 30x24x16 30x24x16
30 30x24x16 30x24x16 30x24x16 30x24x16
40 36x30x16 36x30x16 36x30x16 36x30x16

460 V
Enclosure Dimensions
With Circuit Breaker 3-Contactor Bypass
HP No Options or Line Reactor 3-Contactor Bypass & Circuit Breaker
7.5 30x24x16 30x24x16 30x24x16 30x24x16
10 30x24x16 30x24x16 30x24x16 30x24x16
15 30x24x16 30x24x16 30x24x16 30x24x16
20 30x24x16 30x24x16 30x24x16 30x24x16
25 30x24x16 30x24x16 30x24x16 30x24x16
30 30x24x16 30x24x16 30x24x16 30x24x16
40 36x30x16 36x30x16 36x30x16 36x30x16
50 36x30x16 36x30x16 36x30x16 36x30x16
60 36x30x16 36x30x16 36x30x16 36x30x16
75 36x30x16 36x30x16 36x30x16 36x30x16
100 46x30x16 46x30x16 70x30x24 70x30x24
125 46x30x16 46x30x16 70x30x24 70x30x24
150 87x31x24 87x31x24 87x48x24 87x48x24
200 87x31x24 87x31x24 87x48x24 87x48x24
250 87x31x24 87x37x24 87x48x24 87x48x24
350 87x37x24 87x48x24 87x48x24 87x72x24
400 87x37x24 87x48x24 87x48x24 87x72x24
500 87x48x24 87x48x24 87x72x24 87x96x24
600 87x48x24 87x72x24 87x72x24 87x96x24
700 87x48x24 87x72x24
Consult factory

Return to the
2-50 benshaw.com Table of Contents
Sensorless Vector Drives
S4 Series Dimensions

230 V
Enclosure Dimensions
With Circuit Breaker 3-Contactor Bypass
HP N12 No Options or Line Reactor 3-Contactor Bypass & Circuit Breaker
1 30x24x16 30x24x16 30x24x16 30x24x16
2 30x24x16 30x24x16 30x24x16 30x24x16
3 30x24x16 30x24x16 30x24x16 30x24x16
5 30x24x16 30x24x16 30x24x16 30x24x16
7.5 30x24x16 30x24x16 30x24x16 30x24x16
10 30x24x16 30x24x16 30x24x16 30x24x16
15 30x24x16 30x24x16 30x24x16 30x24x16
20 30x24x16 30x24x16 30x24x16 30x24x16

460 V
Enclosure Dimensions
With Circuit Breaker 3-Contactor Bypass
HP N12 No Options or Line Reactor 3-Contactor Bypass & Circuit Breaker
1 30x24x16 30x24x16 30x24x16 30x24x16
2 30x24x16 30x24x16 30x24x16 30x24x16
3 30x24x16 30x24x16 30x24x16 30x24x16
5 30x24x16 30x24x16 30x24x16 30x24x16
7.5 30x24x16 30x24x16 30x24x16 30x24x16
10 30x24x16 30x24x16 30x24x16 30x24x16
15 30x24x16 30x24x16 30x24x16 30x24x16
20 30x24x16 30x24x16 30x24x16 30x24x16
25 30x24x16 30x24x16 30x24x16 30x24x16
30 30x24x16 30x24x16 30x24x16 30x24x16
40 36x30x16 36x30x16 36x30x16 36x30x16
50 36x30x16 36x30x16 36x30x16 36x30x16
60 36x30x16 36x30x16 36x30x16 36x30x16
75 36x30x16 36x30x16 36x30x16 36x30x16
100 46x30x16 46x30x16 70x30x24 70x30x24
125 46x30x16 46x30x16 70x30x24 70x30x24
150 87x31x24 87x31x24 87x48x24 87x48x24
200 87x31x24 87x31x24 87x48x24 87x48x24

Return to the
Table of Contents 2-51
Integrated control solutions using both

Systems integration is a central focus of our business, and a competitive advantage


for our customers.

Benshaws success in the OEM and industrial Customized Enclosures: Intelligent Motor Controls:
marketplace is a direct result of our willingness
Benshaw takes great pride in our ability to Benshaw offers a full range of intelligent,
as a company to think "beyond the box".
design and deliver custom control enclosures programmable, low and medium voltage
Weve made systems integration a central
that truly complement the form and function starters and drivesfrom fractional to 20,000
focus of our business, and we make learning
of your machine. HPto meet a variety of motor control needs.
your business a top priority.
NEMA 1, 12, 3R, 4 and 4X enclosures in unit Motor control products include full voltage
By focusing on the bigger picture we gain
mount, console mount, free-standing and starters, solid state reduced voltage starters
a better understanding of your process,
wall-mount configurations are available and variable frequency drives. Reversing, two-
your control requirements and your
to suit your needs. speed, DC braking, wye-delta, synchronous
market objectives.
and wound rotor control are supported.
Every enclosure we design is carefully crafted
We then apply that knowledge toward
to meet your dimensional requirements,
the development and production of
proto-typed and tested for fit and compliance
complete, cost-effective, fully integrated
with relevant safety standards, fabricated
control solutions.
to exacting tolerances and finished to your
paint specification.

Return to the
2-52 benshaw.com Table of Contents
Benshaw and additional brands.

Integrated Machine Logic: Integrated Power Packages: Typical OEM / Industrial Applications
Benshaw can supply standard or PC-based Benshaw can also incorporate all of the Air and process compressors
programmable logic controllers, and will power distribution components needed Blowers and air handling equipment
custom design hardware or software to for your machine in one simple,
Chillers
meet process requirements. plug-and-play package.
Conveyors
Networking capabilities, remote monitoring Turnkey power distribution packages typically
and custom designed human machine include all internal and external motor control Food / liquid processing equipment
interface packages are also available. wiring harnesses, power wiring harnesses, Industrial refrigeration equipment
motor/machine sensor connections and, Municipal waste / water
Integrated Control Sensors: if needed, a fully integrated power factor handling machines
Benshaw can integrate any number of sensors, correction unit.
Pumps
transducers, relays, switches, meters and
All power systems are factory tested Pipelines
protective devices, as required, to precisely
at Benshaw with custom-built machine
monitor and respond to all critical process, Shredders / grinders
simulators and wire pull-testers to
machine or environmental variables. Specialty machinery
guarantee reliable performance.
Transfer lines

Let our knowledge become


your competitive edge.

Return to the
Table of Contents 2-53
Custom-engineered drive solutions.
For any drive application.
In any configuration.
Whether you need simple modifications made to one of Benshaws standard drive
packages, a custom engineered, application-specific drive package or a turnkey drive
solution, Benshaw can help.
With engineering experience and complete motor control system production
capabilities, Benshaw delivers all of the competence, convenience and value
youd expect from a leader in engineered control systems.

Whatever your motor control needs may be, Benshaws engineering teams
and application specialists can help you find a cost-effective, reliable solution.

Quality assurance testing Control Modifications:


Benshaws assembly teams perform a Over 250 control modifications
preliminary quality assurance inspection and accessories are available
before delivery is made. Drive assemblies from Benshaw, including:
undergo a variety of testing procedures,
Pilot devices
including motor operation testing, load
testing, control circuit testing, wire pull Control power transformers
testing, electrical performance checks, Switches
mechanical alignment inspection, torque
Meters
measurement and user interface /
pilot device functionality. Relays
Space heaters
All test processes meet or exceed ISO 9001
requirements, and all tests are documented Protective devices
and archived for quality verification. PLCs
Enclosures: Bypass Packages:
Standard NEMA 1, 12 and 3R Three contactor
enclosure designs
Reduced voltage solid state starters
Custom enclosures
Filters:
NEMA 4, 4X, air conditioned
and other special enclosures Line reactors (3% and 5%)
Motor control centers Long lead filters
Combination drive packages Passive harmonic filters
152,000 A circuit breakers 18 pulse systems (IEEE-519)
402,000 A non-fused disconnects
30800 A fusible disconnects
Flange or rotary handle mechanisms

Benshaw delivers...no matter


what your motor control needs.
Return to the
2-54 benshaw.com 2-54
Table of Contents
Clean Power Drives
SG 519 Series IEEE-519 Compliant
Product Highlights:
RATINGS
Benshaws SG 519 Series drives are designed and manufactured to limit voltage and current
distortion levels to within the levels defined by IEEE-519*. This eliminates the need for
Standard Duty: expensive, time consuming harmonic analysis and avoids the resonance problems associated
with inefficient harmonic filters.
50600 HP @ 460 V
Our municipal projects and engineering team will work with you to configure a clean power
Heavy Duty: solution that meets your specifications and requirements.

50500 HP @ 460 V Modular Design:


The modular design of Benshaws SG 519 Series drives eliminates maintenance problems
inherent in older drive designs and improves drive reliability by significantly reducing power
module part counts. This design approach also allows each drive unit to be custom-tailored
to your specific requirements.

Optional Bypass:
An optional bypass design configuration (ATL or RVSS) is available for SG 519 drive
packages when mission critical reliability is important and disruptive downtime cannot
be tolerated.

Standard Features:
SG Series drive
NEMA 1 ventilated enclosure
65 kAIC circuit breaker with lockable disconnect
Phase-shifting transformer and line reactor
12-pulse rectifier unit
Control transformer with extra 120 V capacity
Door-mounted control
Keypad / display start / stop buttons
Reset button hand-off-auto switch
Speed potentiometer
Options
Bypass (ATL or RVSS)
Line fusing
Output filter (reactor, long lead or sine wave)
Enclosures NEMA 12, 3R, 4 or 4X (with AC unit)
RTD monitor
Communications
Control options to customer specification

* IEEE-519, 1992 Table 10-2 and Table 10-3.

Return to the
Table of Contents 2-55
Engineered Low
Voltage Drive Products
Clean Power Drives
Engineered Packages
Part Number Assembler

RSI 519 060 SG 4 NC A 1/12

VFD VFD Series Package Type


RSI = RediStart SG = Sensorless A = Packaged Drive,
Inverter Vector Drive No Bypass
C = Packaged Drive with
Three Contactor Bypass
SS = Packaged Drive with
Soft Starter (SS)
Bypass**
18 Pulse Horsepower Voltage
519 = 18 Pulse 050 = 50 HP 4 = 460 V
060 = 60 HP
075 = 75 HP
100 = 100 HP
125 = 125 HP Disconnect Options Enclosure**
150 = 150 HP NC = Non-Combination** 1/12 = NEMA 1/12
200 = 200 HP CB = Circuit Breaker 4 = NEMA 4*
250 = 250 HP (65 Kaic)
3R = NEMA 3R
300 = 300 HP FD = Fusible Disconnect**

400 = 400 HP
500 = 500 HP
600 = 600 HP
700 = 700 HP

* Air conditioning required.


** Consult factory.

Return to the
2-56 benshaw.com Table of Contents
Clean Power Drives
IEEE-519 460 V, SG Series, NEMA 1, No Bypass
Standard Duty Heavy Duty Dimensions (in.)
Model Number HP Amps HP Amps H W D List Price
RSI-519-050-SG-4-CB-A-01 50 65 40 52 90 36 30 $26,231.00
RSI-519-060-SG-4-CB-A-01 60 77 50 65 90 36 30 $28,226.00
RSI-519-075-SG-4-CB-A-01 75 96 60 77 90 36 30 $30,912.00
RSI-519-100-SG-4-CB-A-01 100 124 75 96 90 36 30 $32,230.00
RSI-519-125-SG-4-CB-A-01 125 156 100 124 90 36 30 $35,435.00
RSI-519-150-SG-4-CB-A-01 150 180 125 156 90 48 30 $41,818.00
RSI-519-200-SG-4-CB-A-01 200 240 150 180 90 48 30 $49,121.00
RSI-519-250-SG-4-CB-A-01 250 302 200 240 90 48 36 $52,583.00
RSI-519-300-SG-4-CB-A-01 300 361 250 302 90 78 36 $62,092.00
RSI-519-350-SG-4-CB-A-01 350 414 90 78 36 $65,675.00
RSI-519-400-SG-4-CB-A-01 400 477 300 361 90 78 36 $75,500.00
RSI-519-500-SG-4-CB-A-01 500 590 350 414 90 96 36 $95,639.00
RSI-519-600-SG-4-CB-A-01 600 720 400 477 90 96 36 $120,123.00
RSI-519-700-SG-4-CB-A-01 700 840 500 590 90 96 36 $130,631.00

IEEE-519 460 V, SG Series, NEMA 1, With Bypass (Three Contactor)


Standard Duty Heavy Duty Dimensions (in.)
Model Number HP Amps HP Amps H W D List Price
RSI-519-050-SG-4-CB-C-01 50 65 40 52 90 36 30 $26,582.00
RSI-519-060-SG-4-CB-C-01 60 77 50 65 90 36 30 $28,655.00
RSI-519-075-SG-4-CB-C-01 75 96 60 77 90 36 30 $31,352.00
RSI-519-100-SG-4-CB-C-01 100 124 75 96 90 48 30 $32,781.00
RSI-519-125-SG-4-CB-C-01 125 156 100 124 90 48 30 $36,569.00
RSI-519-150-SG-4-CB-C-01 150 180 125 156 90 54 30 $43,006.00
RSI-519-200-SG-4-CB-C-01 200 240 150 180 90 54 30 $50,609.00
RSI-519-250-SG-4-CB-C-01 250 302 200 240 90 78 36 $54,119.00
RSI-519-300-SG-4-CB-C-01 300 361 250 302 90 96 36 $63,790.00
RSI-519-350-SG-4-CB-C-01 350 414 90 96 36 $69,728.00
RSI-519-400-SG-4-CB-C-01 400 477 300 361 90 96 36 $79,553.00
RSI-519-500-SG-4-CB-C-01 500 590 350 414 90 96 36 $99,692.00
RSI-519-600-SG-4-CB-C-01 600 720 400 477 90 96 36 $124,319.00
RSI-519-700-SG-4-CB-C-01 700 840 500 590 90 96 36 $136,031.00

Return to the
Table of Contents 2-57
Engineered Low
Voltage Drive Products
Clean Power Drives
IEEE-519 460 V, SG Series, NEMA 1, With Bypass (RVSS)
Standard Duty Heavy Duty Dimensions (in.)*
Model Number HP Amps HP Amps H W D List Price
RSI-519-050-SG-4-SS-D-01 50 65 40 52 90 36 30 $27,572.00
RSI-519-060-SG-4-SS-D-01 60 77 50 65 90 36 30 $29,700.00
RSI-519-075-SG-4-SS-D-01 75 96 60 77 90 36 30 $32,559.00
RSI-519-100-SG-4-SS-D-01 100 124 75 96 90 48 30 $34,406.00
RSI-519-125-SG-4-SS-D-01 125 156 100 124 90 48 30 $38,300.00
RSI-519-150-SG-4-SS-D-01 150 180 125 156 90 54 30 $44,825.00
RSI-519-200-SG-4-SS-D-01 200 240 150 180 90 54 30 $52,634.00
RSI-519-250-SG-4-SS-D-01 250 302 200 240 90 78 36 $56,222.00
RSI-519-300-SG-4-SS-01 300 361 250 302 90 114 36 $69,584.00
RSI-519-350-SG-4-SS-D-01 350 414 90 114 36 $76,518.00
RSI-519-400-SG-4-SS-D-01 400 477 300 361 90 114 36 $86,341.00
RSI-519-500-SG-4-SS-D-01 500 590 350 414 90 132 36 $106,480.00
RSI-519-600-SG-4-SS-D-01 600 720 400 477 90 132 36 $131,455.00
RSI-519-700-SG-4-SS-D-01 700 840 500 590 90 132 36
* Enclosure Dimensions
Consult factory

Included in Standard Package: Options


SG Series VFD NEMA 12V, 3R, 4, 4X enclosures
NEMA 1 ventilated enclosure Air conditioning
Circuit breaker disconnect Input fusing
18 pulse transformer Output reactor
Input line reactor Long lead filter
Control transformer Input filter (in lieu of 18-pulse input)
Door-Mounted Control devices (keypad, start / stop, Bypass (three contactor or RVSS)
reset, HOA switch, speed potentiometer)
Control options to customer specification
Communications

Return to the
2-58 benshaw.com Table of Contents
Medium Voltage Starters
Standard Medium Voltage
Starter Products
Next Generation Intelligent
Motor Control.....................................3-2
Prepackaged Solid State Starters........3-4
Built-To-Order, Solid State
Reduced Voltage Starters................... 3-7
Build Your Customized Starter............3-8
Engineered-to-Order Capability.......3-10
Engineered Medium Voltage
Starter Products
Combination Solid State Starters...... 3-11
Medium Voltage Starter
Order Check List...............................3-16
Smart Full Voltage ATL Starters.........3-19
Full Voltage ATL Starters...................3-22
Main Lug Only...................................3-24
Load Interrupter Switch.....................3-26
Engineered Medium Voltage
Starter Options
Pilot Devices.....................................3-28
Control Options................................3-30
Motor Protective Relays.................... 3-31
Enclosure and Bus Options...............3-32
Power Factor Correction
Capacitors.........................................3-33
Surge / Lighting Arrestors.................3-34
Surge Capacitors...............................3-35
Line Reactors.....................................3-36
Documentation................................. 3-37
Wound Rotor Starters.......................3-38
Wound Rotor Motor Starter
Check List..........................................3-39
Synchronous Starters.........................3-40
Synchronous Motor Starter
Check List.......................................... 3-41
MX3 Intelligent Motor Control..........3-42
Mission Critical Reliability.................3-44
Return to the
Table of Contents 3-1
Standard Medium
Voltage Starter Products
Next Generation Intelligent Motor Control
MX 3 Controller

Fiber Optic SCR Firing Product Highlights:


Integrated technology Next generation MX3 technology forms the backbone of Benshaws entire line of intelligent
Noise immunity medium voltage motor controls. With fiber optic firing, enhanced programming capabilities,
ease of use and a unique, flexible architecture, Benshaws MX3 controller delivers unprecedented
High voltage isolation
functionality and all of the rugged, dependable performance youve come to expect from a
Safe, reliable SCR control world leader in solid state motor controls and drives.

MX3 controllers, power components, software and sensors are all designed, built and tested
to perform as an integrated control system, eliminating the coordination and performance
problems inherent in other forms of reduced voltage starting.

With more built-in features, more configurable options, greater expandability and a broader
communications capability than any other motor control on the market, Benshaws next
generation MX3 technology will shorten your commissioning times, improve motor performance
and protection, enhance diagnostic capability and streamline many electrical system monitoring
and maintenance tasks.

Key Features:
Keypad (Included) High performance motor control with multiple starting modes built in
Flexible, programmable I/O
Integrated motor protection
Line and motor metering
Diagnostic capabilities with event log and real-time clock
Built-in remote self-testing (BIST)
Expanded communications capabilities
Intelligent SCR power poles
Intelligent MV MCC integration

Optional RTD Modules

Return to the
3-2 benshaw.com Table of Contents
Next Generation Intelligent Motor Control
MX 3 Controller
Control Features

Multiple Starting Modes: Metering: 8 Digital Inputs 1 Analog 420 mA /


Voltage ramp Accuracy: Configurable to: 010 VDC Output
Current ramp 3% out-of-box Stop Configurable to:
Adjustable initial current 2% factory calibrated Fault Current (0200%/0800%)
Adjustable maximum Average current Fault reset Voltage (0150%)
current Bypass / inline confirm OL (0150%)
L1 current
Adjustable ramp time OL reset kW (010 kW/0100 kW)
L2 current
Torque ramp (TruTorque) Local / remote selection MW (01 MW)
L3 current
Adjustable initial torque Heater enable Analog input (0100%)
Current imbalance %
Adjustable maximum Heater disable Firing (0100%)
Ground fault current
torque
Average volts Dual ramp selection Calibration
Adjustable ramp time
L1L2 voltage 1 dedicated start input User Interface:
Power ramp
L2L3 voltage Disconnect Event log (99 events)
Adjustable initial torque
L3L1 voltage Slow speed Door mounted LCD display
Adjustable maximum
torque Overload % Brake enable Set / examine operating
Brake disable parameters
Adjustable ramp time Power factor
View status information,
Linear / tach feedback control Watts 6 Relay Outputs line current, voltage
Motor Protection: VA Configurable to: and frequency

Motor thermal overload VARS Faulted Start and stop the


kW hours Running solid state starter
Independent starting
and running OLs MW hours Up to speed 1 Communication Port:
Up to speed timer exceeded Phase order Alarm condition ModBus / RS485
Low line voltage Line frequency Ready condition Advanced Functionality:
Low line frequency Analog input Locked out Dual ramp selection
High line frequency Analog output Over current Adjustable kick current
Phase reversal Run timedays Under current Programmable decel modes
Phase loss Run timehours OL alarm MV BIST test (built-in self test)
Instantaneous overcurrent # of starts Shunt trip
Overcurrent Tru Torque % Ground fault
Undercurrent Power % Energy saver indication
Current imbalance Peak starting current Heating indication
Ground fault (residual Last starting duration Cooling fan
or zero sequence)
RTD temperatures 1 Analog 420 mA /
Shorted or open SCR
Real-time clock 010 VDC Input
Disconnect fault
Configurable to:
Inline contactor fault
Trip high level
Control power low
Trip low level
Stack over temperature
Motor PTC input
RTD modules

Return to the
Table of Contents 3-3
Standard Medium
Voltage Starter Products
Prepackaged Solid State Starters
MVRXE Series Emergency ATL Bypass, Severe Duty, Load Break
Fusible Disconnect
Product Highlights:
The Benshaw Medium Voltage Starter is a microprocessor controlled solid state
reduced voltage starter for three phase induction motors. The starter provides
a closed-loop current ramp for smooth stepless motor acceleration. Supplied
in a free standing enclosure.

Enclosures are available in NEMA 12 or NEMA 3R configurations. The medium voltage


enclosure consists of two distinct compartments. The medium voltage or power pole
section is located in the main body of the enclosure, whereas the low voltage section
containing the control logic is located behind the door as an isolated compartment.

Each starter is supplied with a load break isolation switch, Class "R" motor fuses, inline
vacuum contactor, solid state power poles and a vacuum bypass contactor, which is
used to bypass the SCR power poles once the motor is up to full speed.

The logic control incorporates the MX3 computer that has all the circuitry required
to drive the power semiconductors, which are located in the power section.

MVRXE starters provide solid state reduced voltage starting for normal operation
and full voltage emergency back-up starting, with complete electronic motor
protection at the flip of a switch.

This unique redundant design is ideal for critical applications where downtime
is extremely disruptive and cannot be tolerated.

MX3 solid state controls provide precise digital starting and stopping,
motor protection, metering, diagnostics and communications, standard.

Key Advantages:
NEMA 12, UL 347 listed
45 kV BIL
Service entrance labeled (optional)
Built-in self test (BIST) features for "quick commissioning"
Solid state reduced voltage startingnormal operations
425 A load break
Switch selectable emergency back-up full voltage starter
MX3-embedded digital control
Fiber optic SCR firing
Advanced motor protection
Advanced metering
Power quality protection
Diagnostics and ModBus RTU485 communications standard

Return to the
3-4 benshaw.com Table of Contents
Prepackaged Solid State Starters

Standard Features:
NEMA 12, solid state starter, UL347 listed, Fixed mounted, start duty rated vacuum Door-mounted LCD keypad
Class E-2 contactors for isolation and SCR bypass,
Door-mounted run indication light
wired for normal bypass operation and full
45 kV BIL
voltage start operation, with (2) N/O and Door-mounted local-off-remote switch
200 MVA (2300 VAC) / 350 MVA (2) N/C auxiliary contacts Door-mounted reset button
(4160 VAC) short circuit fault rated
Separately mounted "SPE" series Terminal strip mounted inside LV
500%30 seconds rated solid state electronic overload device has the compartment for:
starterUL347 certified and listed following standard features:
Remote start / stop control
8,000 PIVUL347 certified Class 1030 adjustable
and listed at 2.4 kV Remote up-to-speed indication
Phase imbalance protection
12,000 PIVUL347 certified Remote run indication
1 NO / 1 NC trip contact
and listed at 4.2 kV Remote fault indication
Phase reversal protection
Fiber optic SCR firing Benshaw MX3 controller with
"Trip free" design complete soft start, soft stop
Selectable solid state or emergency full
voltage operation via selector switch Phase loss protection and motor protection capabilities
mounted inside of LV compartment 485 communications capabilities
Built-in self test (BIST) features
Load matched Class R fusing with blown for "quick commissioning" local through door connection
fuse indication or remote from starter (optional)
120 VAC, 1000 VA CPT with primary and
425 A load break, 5 kV rated disconnect secondary fusing, with 500 VA available ModBus communications standard
switch, with viewing window, grounding for customer use
assembly and lockable handle
Door-mounted start and stop
mechanism; mechanically interlocked
push buttons
for safety

Benshaw MVRXE vs. Any Autotransformer Starter


Motor Control & Protection Functions Any Auto Transformer Benshaw MVRXE
Soft Start Yes Yes
Soft Stop No Yes
Full Voltage Bypass Starting No Yes
Load Break Disconnect Switch No Yes
Built-In Self Test No Yes
UL 347 / Service Entrance Rated (Optional) No Yes
3 Year Warranty No Yes
Plain English Digital Display No Yes
Electronic OL Protection No Yes
Electronic Power Quality No Yes
Digital Metering No Yes
Embedded Plain English Diagnostics No Yes
Embedded RS485 No Yes
Incoming Line Landing Pad No Yes
Integrated Control & Protection No Yes
UL Zero Sequence Ground Fault * No Yes
* Optional ground fault CT required

Return to the
Table of Contents 3-5
Standard Medium
Voltage Starter Products
Prepackaged Solid State Starters

MVRXE Series
Emergency ATL Bypass, Load Break Fusible Disconnect
MVRXE184160 V
Dimensions (in.)
NEMA 12 NEMA 3R
Model Number HP A H W D Weight (lbs.) List Price List Price
MVRXE18-1000-4160 ** 1000 133 92 36 32 2,000 $45,175.00 $48,150.00
MVRXE18-1500-4160 ** 1500 200 92 36 32 2,000 $45,750.00 $48,375.00
MVRXE18-3000-4160 ** 3000 330 92 36 32 2,000 $54,945.00 $57,995.00
Starters are top entry / bottom exittop exit available upon request. Dimensions and weights are approximate.
Available for same day shipping.
** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R

Web stocked

MVRXE122300 V
Dimensions (in.)
Weight NEMA 12 NEMA 3R
Model Number HP A H W D (lbs.) List Price List Price
MVRXE12-550-2300 ** 550 133 92 36 32 1,800 $41,495.00 $44,445.00
MVRXE12-750-2300 ** 750 200 92 36 32 1,800 $42,895.00 $45,850.00
MVRXE12-1500-2300 ** 1500 330 92 36 32 1,800 $48,750.00 $52,665.00
Starters are top entry / bottom exittop exit available upon request. Dimensions and weights are approximate.
** Insert appropriate option code as shown: NEMA 12 = 12 / NEMA 3R = 3R
NOTE: Power fuses ship loose. Please provide motor full load amps at time of order for proper fuse sizing.
Please allow a 4 week lead time.

Modular Options
Model Number Description List Price
A171 Space Heater with Thermostat (Included In NEMA 3R Option) $495.00
A008 E-Stop Push-Button, Mushroom Head, Red $145.00
A406 8-Channel RTD Module, 100 ohm Platinum (Also Available for Remote Mounting) $2,850.00
A407 16-Channel RTD Module(s), 100 ohm Platinum (Also Available for Remote Mounting) $5,235.00
A408 * Top Hat Enclosure Module for Top Entry (18"H x 30"W x 20"D), $2,395.00
Top Left or Top Right Mounting, Accommodates Stress Cones
A409 Service Entrance Labeled $885.00
A106 Additional 1000 VA Control Power Transformer $865.00
The MVRXE series was designed as an integrated package. Listed above are the available modular options.
For systems requiring more extensive requirements, please refer to the MV engineered section of the this catalog beginning on page 3-12.
Refer to MLO section beginning on page 3-24 for starters that require top/top or bottom/bottom entry/exit locations.
* Top hat will ship loose for customer installation.
Built-to-order: Please allow 2 weeks for shipment of complete MVRXE unit when ordering these options with a stock starter.

Protective Relay Options


Model Number Description List Price
A875 Ground Fault CT, 2000:1, 4.0:Dia. (For MX Use) 3
$795.00
A876 Ground Fault CT, 2000:1, 8.13:Dia. (For MX3 Use) $1,625.00

Return to the
3-6 benshaw.com Table of Contents
Built-To-Order, 2 Week Shipment
Solid State Reduced Voltage Starters
4,160 Volt Product Highlights:
Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product
MVRMX Series options, and developed a modular architecture to offer those options most ordered on a Built-
To-Order program. This has enabled us to offer you a customized product with a reduced lead
01,500 HP or time. Our goal is to optimize our response to meet your mission critical application needs.

1,5013,000 HP The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family
of Class E2 load break/combination solid state starters. This integrated design includes control
and power electronics, bypass and isolation contactors that reduce maintenance and operating
costs when compared to other methods.

Key Advantages:
Protect machinery from failure and excessive maintenance caused by mechanical shock
during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration
and controlled deceleration.

Protect electrical systems from disruptive voltage drops and power outages caused by
motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current
ramp during start up.

Protect mission critical motors from failure or unscheduled outages caused by machine or
electrical system faults. The RediStart MVRMX starter provides complete, high performance,
coordinated line monitoring, motor control and protection.

Protective Relay Options


Description Specification
Starting Method Closed Loop Current Control Ramp
Torque Ramp
Power Ramp (kW)
Voltage Ramp
Linear Accel / Tach Feedback
Power Ratings Reference Table A (See page 3-9)
Control Input 120 VAC or Dry Contact, 2 or 3 Wire
Standard Insulation Test 2X Rated V + 2,000 V
Nominal Voltage Ratings 4.16 kV
Ambient Temperature 040 C to 3,300 ft.
Frequency Range 2372 Hz on Control Board
Overall Efficiency (W / Bypass) 99.50%
Metering Functions 47 Parameters
Relay Outputs 24 Functions
Over / Under Voltage Protection 10 to 30%
Power Loss (W / Bypass) <0.1 Watt/Amp/Phase
Transient Protection DV/DT Circuits/Phase
PIV Ratings 4 kV: 12,000 V
SCR Firing Technique Hard Gate Continuous Block
Fiber Optic Firing
Basic Impulse Level 45 kV
Short Circuit Current Rating 350 MVA
UL / CUL Yes
Return to the
Table of Contents 3-7
Build your
customized starter!
Only one option can be selected from each group, Choose Enclosure Options
12 NEMA 12 $0
with the exception of the Control Options section. SH NEMA 12 with space heater $650

Add the appropriate code for the options chosen 3R NEMA 3R with space heater $1,250

to the code string across the center of the page.


A B C

MVB43 225 B 12 S G 1N

0 to 1,500 HP 1,501 to 3,000 HP Choose Service


A B C A B C
Entrance Rated
(for stand-alone single units)
Choose Choose
Choose Choose Exit/ Choose Choose Exit/ S Yes $1,500
Core Motor Landing Core Motor Landing N No $0
Unit Current** Option*** Unit Current** Option***
MVB41 025 T $41,000 MVB43 025 T $45,995
MVB41 025 B $40,795 MVB43 025 B $45,775 1,500
MVB41 025 C $40,000 MVB43 025 C $44,750 0 to to
Choose Bus 1,500 3,000
MVB41 045 T $41,000 MVB43 045 T $45,995 Options+ HP HP
MVB41 045 B $40,795 MVB43 045 B $45,775
8N 800 A $1,500 $1,750
MVB41 045 C $40,000 MVB43 045 C $44,750 non-
MVB41 055 T $41,000 MVB43 055 T $45,995 insulated
MVB41 055 B $40,795 MVB43 055 B $45,775 bus
MVB41 055 C $40,000 MVB43 055 C $44,750 8I 800 A $2,150 $2,195
insulated
MVB41 080 T $41,000 MVB43 080 T $45,995
bus
MVB41 080 B $40,795 MVB43 080 B $45,775
1N 1,200 A $1,750 $1,850
MVB41 080 C $40,000 MVB43 080 C $44,750 non-
MVB41 090 T $41,500 MVB43 090 T $46,150 insulated
MVB41 090 B $40,995 MVB43 090 B $46,050 bus
MVB41 090 C $40,250 MVB43 090 C $45,150 1I 1,200 A $2,500 $2,555
MVB41 133 T $41,500 MVB43 133 T $46,150 insulated
bus
MVB41 133 B $40,995 MVB43 133 B $46,050
2N 2,000 A $2,750 $2,795
MVB41 133 C $40,250 MVB43 133 C $45,150
non-
MVB41 170 T $41,500 MVB43 170 T $46,150 insulated
MVB41 170 B $40,995 MVB43 170 B $46,050 bus
MVB41 170 C $40,250 MVB43 170 C $45,150 2I 2,000 A $3,795 $3,850
insulated
MVB43 225 T $46,995
bus
MVB43 225 B $46,750
NR None $0 $0
MVB43 225 C $45,995 required
MVB43 330 T $46,995
+Bus not required for single
***Exit / Landing Options MVB43 330 B $46,750 stand-alone unit.
T Top exit with landing pad MVB43 330 C $45,995 Bus is required for connection
of 2 or more units.
B Bottom exit with landing pad MVB43 360 T $46,995 Any unit with bus will require additional
MVB43 360 B $46,750 MLO section. Please contact the factory
C Top or bottom exit landing
for pricing and delivery.
on bypass contactor MVB43 360 C $45,995

Return to the
3-8 benshaw.com Table of Contents
Choose Communications Options
(RS-485 Modbus RTU standard)
Choose Option Zero Sequence
Ground Fault Ct 2000:1 D DeviceNet $1,500
(Residual included) E Ethernet $1,750 NEW
G Yes $750 P Profibus $2,250
Optional
N No $0 N None $0
Safety
Feature:
D E F G H I
Benshaws
1N D 2 N B N N E E answer to
remote
open/close
Choose RTD Options Choose Control Options disconnect
(100 ohm platinum) Choose one option for each item below
2 8-channel RTD $2,850 D A ATL option* D N None $595 ability.
4 16-channel RTD $5,235 E B Green start E N None $295 Please
N None $0 push button
& red stop contact
extended
push button* factory and
C Red run light N None $295
Choose Bus Splice Options
F
& green stop
F
reference
(must match bus option selected) light part number
8N 800 A non-insulated bus splice $395 G D Amber fault G N None $295
8I 800 A insulated bus splice $625 light & black EMO-425D
reset push
1N 1,200 A non-insulated bus splice $499
button (Electric
1I 1,200 A insulated bus splice $725
2N 2,000 A non-insulated bus splice $850
H E Local-off-
remote
H N None $175 Motor
2I 2,000 A insulated bus splice $1,050 3-position Operator).
NR None required $0 switch
I F Emergency I N None $185
stop push
button

* Indicates ATL option comes with Start and Stop


Push Buttons i.e. Start Stop Push Buttons cannot
be selected.
No selection = keypad control.
Recommend E stop option be selected.

Table A
**Motor currents vs. HP
Motor A/HP Starter Rating Motor A/HP Starter Rating
are typical, confirm actual <25/200 500% for 30 sec. <133/1000 500% for 30 sec.
motor current. Service <45/350 500% for 30 sec. <170/1250 350% for 30 sec.

factor not accounted <55/400 500% for 30 sec. <225/1700 500% for 30 sec.
<80/600 500% for 30 sec. <330/2500 350% for 30 sec.
for, adjust if required.
<90/700 500% for 30 sec. <360/3000 350% for 30 sec.

Example: A 3,000 HP (MVB43), 225 A (225) unit with the following options: bottom exit w/landing pad (B), NEMA 12 Enclosure (12), Service
Entrance Rated (S), with Ground Fault (G), 1,200 A non-insulated bus (1N), 1,200 A non-insulated bus splice (1N), with DeviceNet (D), 8 channel
RTD (2), without ATL option (N), with start and stop buttons (B), without run and stop lights (N), without fault and reset lights (N), with a local-off-
remote switch (E), with emergency stop push button (F) would build the following code string: MVB43225B12SG1N1ND2NBNNEF

Return to the
Table of Contents 3-9
Engineered-to-Order Capability
Benshaw has developed advanced engineering, drafting, materials management
and quality systems focused on designing and building customer solutions. This
"Engineered-to-Order" capability, combined with an extensive inventory of control
components, protective relays, circuit breakers, contactors, enclosures and other
electrical / electronic devices, enables Benshaw to quickly ship engineered products.

Control ModificationsWhatever you specify


Over 250 modifications and accessories are available, including: pilot devices,
communication, PLCs, control power transformers, switches, meters, relays,
space heaters, protective devices, power factor correction capacitors, surge
arrestors and line reactors

Combination StartersTo Meet Your Requirements:


Solid state reduced voltage
Standard full voltage
Smart full voltage
Solid state with full voltage bypass
Power RatingsTo Fit Your Application:
5 kV Class10,000 HP
7.2 kV Class30,000 HP
15 kV Class30,000 HP
EnclosuresTo Match Your Environment:
Standard designsNEMA 1, 12, 3R
Custom enclosures
Motor control centers

Return to the
3-10 3-10 benshaw.com
benshaw.com Table of Contents
Engineered Medium Voltage Starter Products
Combination Solid State Starters
MVRMX Series Product Highlights:
Only Benshaw has designed, built and supports more than 40,000 solid state starters, from
5 kV / 7.2 kV / 2,300 volts to 15 kV, for applications ranging from pumps, compressors and chillers to fans
and blowers, crushers, chippers and conveyorsfor every motor type: induction, synchronous,
15 kV Up to 30,000 HP two-speed, reversing and wound rotor.

The RediStart CFMVRMX series with MX3 technology is a fully integrated, programmable family
of Class E2 load break/combination solid state starters. This integrated design includes control
and power electronics, bypass and isolation contactors that reduce maintenance and operating
costs when compared to other methods.

Key Advantages:
Protect machinery from failure and excessive maintenance caused by mechanical shock
during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration
and controlled deceleration.

Protect electrical systems from disruptive voltage drops and power outages caused by motor
locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp
during start up.

Protect mission critical motors from failure or unscheduled outages caused by machine or
electrical system faults. The RediStart MVRMX starter provides complete, high performance,
coordinated line monitoring, motor control and protection.

Precision Engineered Products from Benshaw:


Rugged enclosures to Specified control and
match your environment: protective devices:

NEMA 1 Protective relays


NEMA 12 RTD monitors
NEMA 12V Custom control / interface configuration
NEMA 3R Pilot devices / PLCs
Marine duty Specified surge capacitors
Lineups and lightning arrestors:

Specified bus configurations: Benshaw will design and mount (as an


integrated unit) surge capacitors and lightning
Tin plated copper
arrestors to match your electrical system and
800 / 1200 / 2000 A lightning protection requirements.
Top mount Load engineered power factor capacitors
Environmentally or electrically insulated and controls:
Custom arrangements Start / run sequencing
Higher BIL ratings available Load matching
Front access copper ground bus

Return to the
Table of Contents 3-11
Engineered Medium
Voltage Starter Products
Combination Solid State Starters
MVRMX Series
5 kV / 7.2 kV / 15 kV Up to 30,000 HP

Power Section Features:


Description Specification
Starter Type Closed Loop Current Control Ramp
Torque Ramp
Power Ramp (kW)
Voltage Ramp
Linear Accel / Tach Feedback
Power Ratings 350% to 500% FLA for 30 up to 90 Sec. 125% Cont.
Control Input 120 VAC or Dry Contact, 2 or 3 Wire
Standard Insulation Test 2X Rated V + 2,000 V
Nominal Voltage Ratings 2.3 kV to 13.8 kV
Ambient Temperature 040 C at Sea Level
Frequency Range 23 to 72 Hz on Control Board
Overall Efficiency (with Bypass) 99.50%
Metering Functions 47 Parameters
Relay Outputs 24 Functions
Over/Under Voltage Protection 10 to 30%
Power Loss (with Bypass) <1.0 Watt / Amp / Phase
Transient Protection DV/DT Circuits / Phase
PIV Ratings 2.4 kV:8000 V, 4.2 kV:12000 V
7.2 kV:18000 V, 13.8 kV:34500 V
SCR Firing Technique Continuous Block Gate
Fiber Optic Firing

Status Display and Indicators:


LCD Status Display LED Indicators
Each starter will have a keypad/display The following LED indicators are provided
assembly designed to: for advisory status and fault annunciation:
Set or examine operating parameters Power ON
Provide status information CPU heart beat
Provide real-time information about line Communications
current, voltage and frequency
RTD module
Provide a means to start and Fiber optic firing
stop the solid state starter

Return to the
3-12 benshaw.com Table of Contents
Combination Solid State Starters
MVRMX Series

2300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMX12-150-2300 ** 2300 150 36 92 36 32 $37,575.00 $39,850.00
CFMVRMX12-500-2300 ** 2300 500 120 92 36 32 $37,575.00 $39,850.00
CFMVRMX12-750-2300 ** 2300 750 180 92 36 32 $40,125.00 $42,395.00
CFMVRMX12-1000-2300 ** 2300 1000 240 92 36 32 $41,235.00 $43,525.00
CFMVRMX12-1250-2300 ** 2300 1250 300 92 36 32 $41,235.00 $43,525.00
CFMVRMX12-1500-2300 ** 2300 1500 360 92 45 32 $42,250.00 $44,435.00
CFMVRMX12-HP-2300 ** 2300 >1500 >360

3300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMX12-300-3300 ** 3300 300 51 92 36 32 $41,325.00 $43,895.00
CFMVRMX12-750-3300 ** 3300 750 127 92 36 32 $41,325.00 $43,995.00
CFMVRMX12-1000-3300 ** 3300 1000 169 92 36 32 $44,150.00 $46,635.00
CFMVRMX12-1250-3300 ** 3300 1250 211 92 36 32 $45,355.00 $47,875.00
CFMVRMX12-1500-3300 ** 3300 1500 254 92 36 32 $45,500.00 $47,995.00
CFMVRMX12-2000-3300 ** 3300 2000 338 92 36 32 $46,375.00 $48,875.00
CFMVRMX12-HP-3300 ** 3300 >2000 >338
CFMVRMX series starters are complete combination E2 controllers. They include a load break / fault make disconnect switch, R rated current limiting motor
fuses, vacuum inline isolation contactor, SCR power stacks and microprocessor controls, CPT and vacuum bypass contactor. MVRMX non-combination starters
are available. Please contact the factory for pricing and application assistance.
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory

Return to the
Table of Contents 3-13
Engineered Medium
Voltage Starter Products
Combination Solid State Starters
MVRMX Series

4160 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMX18-300-4160 ** 4160 300 40 92 36 32 $44,397.60 $46,670.00
CFMVRMX18-750-4160 ** 4160 750 99 92 36 32 $44,475.60 $46,742.80
CFMVRMX18-1000-4160 ** 4160 1000 133 92 36 32 $44,475.60 $46,742.80
CFMVRMX18-1250-4160 ** 4160 1250 166 92 36 32 $44,475.60 $46,742.80
CFMVRMX18-1500-4160 ** 4160 1500 200 92 36 32 $44,475.60 $46,742.80
CFMVRMX18-2000-4160 ** 4160 2000 266 92 36 32 $53,336.40 $55,603.60
CFMVRMX18-2500-4160 ** 4160 2500 333 92 36 32 $53,336.40 $55,603.60
CFMVRMX18-3000-4160 ** 4160 3000 360 92 45 32 $54,132.00 $56,420.00
CFMVRMX18-3500-4160 ** 4160 3500 466 92 96 36 $82,539.60 $84,812.00
CFMVRMX18-4000-4160 ** 4160 4000 532 92 96 36 $82,539.60 $84,812.00
CFMVRMX18-4500-4160 ** 4160 4500 600 92 96 36 $90,422.80 $92,690.00
CFMVRMX18-HP-4160 ** 4160 >4500 >600

6900 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMX18-500-6900 ** 6900 500 42 92 45 36 $74,438.00 $76,700.00
CFMVRMX18-750-6900 ** 6900 750 63 92 45 36 $74,438.00 $76,700.00
CFMVRMX18-1000-6900 ** 6900 1000 84 92 45 36 $74,438.00 $76,700.00
CFMVRMX18-1250-6900 ** 6900 1250 105 92 45 36 $75,010.00 $77,272.00
CFMVRMX18-1500-6900 ** 6900 1500 126 92 45 36 $75,010.00 $77,272.00
CFMVRMX18-2000-6900 ** 6900 2000 168 92 45 36 $75,010.00 $77,272.00
CFMVRMX18-2500-6900 ** 6900 2500 210 92 45 36 $75,800.40 $78,000.00
CFMVRMX18-3000-6900 ** 6900 3000 252 92 45 36 $75,800.40 $78,000.00
CFMVRMX18-3500-6900 ** 6900 3500 294 92 45 36 $75,800.40 $78,000.00
CFMVRMX18-4000-6900 ** 6900 4000 336 92 81 36 $115,000.00 $120,000.00
CFMVRMX18-4500-6900 ** 6900 4500 378 92 81 36 $123,266.00 $125,528.00
CFMVRMX18-5000-6900 ** 6900 5000 420 92 81 36 $123,266.00 $125,528.00
CFMVRMX18-5500-6900 ** 6900 5500 462 92 81 36 $125,751.60 $128,024.00
CFMVRMX18-HP-6900 ** 6900 >5500 >462
CFMVRMX series starters are complete combination E2 controllers. They include a load break / fault make disconnect switch, R rated current limiting motor fuses,
vacuum inline isolation contactor, SCR power stacks and microprocessor controls, CPT and vacuum bypass contactor. CPT is 700 VA standard (6,900 V). MVRMX
non-combination starters are available. Please contact the factory for pricing and application assistance.
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
350% for 30 sec. rated. 500% requires larger sizing. Please contact Benshaw.
Consult factory

Return to the
3-14 benshaw.com Table of Contents
Combination Solid State Starters
15 kV Class Product Highlights:
Benshaw has designed, built and supported custom 15 kV class solutions for all applications and
motor types. Higher voltages bring greater safety concerns, and only Benshaw has over 15 years
Common Voltages:
of experience working with 15 kV class equipment. Whether the equipment is on an oil platform
10 kV or in a mine, Benshaw has experience with 15 kV class equipment all over the globe. Benshaws
11 kV 15 kV class solutions come with standard MX3 technology that is known, qualified and respected
out in the field. Only Benshaw provides 15 kV solutions up to 30,000 HP.
12.47 kV
13.2 kV Key Advantages:
13.8 kV Integrated line reactors within our solution. Higher voltages require more sophisticated
solutions, and only Benshaw provides line reactors that are integrated into all of our 15 kV
class solutions. Benshaw understands the complexities of working in the higher voltages,
Customized Entry/Exit:
and provides equipment reliable in running the most critical applications.
MLOs
Full product portfolios. The heart of solid-state starting is in the power stacks, and Benshaw
Cable Entry Top Hats has the knowledge and experience to understand the complexities of working in the higher
Optional Disconnect/ voltages. Benshaw has custom solutions for 10 kV, 11 kV and 13 kV class equipment, with each
Fusing Input solution consisting of a different design, number of required power electronics and fan cooling
if required. When you get a Benshaw 15 kV class starter, you know it will work in the most critical
applications, since its been designed for the environment.
Specified Controls
Full solutions. Higher voltages require specialized equipment. Benshaws 15 kV class equipment
and Protection Devices:
consists of either a load break disconnect, fusing and vacuum contactors or vacuum circuit
Motor Protection Relays breakers for isolation and bypass. Benshaw has the experience and partners to design, develop
Input Protection Relays and ship a fully integrated solution to fit the application needs.
Lock-Out Relays Engineered support from the quotation through the production cycle. Large critical motors
Custom Control/ require higher voltage solutions. Benshaw understands that these applications require special
Interface Configuration customized solutions, especially for the largest motors. Benshaw provides a team of engineers
to work closely with the end users to design a concept to meet our customers needs. Once
the order is received, Benshaw seamlessly transfers the solution to the production engineering
Specialized Options: department to finalize the design. All of the up-front work saves the customer time and gives
them exactly what they need.
Power Factor
Correction Capacitors
Lightning Arrestors
Surge Capacitors

Return to the
Table of Contents 3-15
Engineered Medium
Voltage Starter Products
Medium Voltage Starter Order Check List
Medium Voltage Check List to assist in the engineering process of providing a properly manufactured Solid State Starter,
which will meet customer specific requirements. Complete each section as this will ensure a timely and accurate response.

Project Name and/or End-User__________________________________________________________

Contact Name________________________________________________________________________

Email_________________________________________________________________________________

Phone Number________________________________________________________________________

SECTION A Starter Application


Type of
application ________________________________________________________________________________________________________________
Present starting
Across the Line Wye-Delta Auto Transformer Other: ______________________________________
method:
Starts / Stops Over 20 (please specify)
15 610 1115 1620
per day: __________________________
Current
>20 seconds (please specify)
Acceleration 15 seconds 610 seconds 1115 seconds 1620 seconds
__________________________
Time
Current
Deceleration >20 seconds (please specify)
15 seconds 610 seconds 1115 seconds 1620 seconds
Time (if __________________________
applicable)
Power source Utility (Transformer feed capacity kVA) (please specify) _____________________________________________________________
Short Circuit MVA (I) (please specify) ______________________________________________________________________________
Delta Wye (please specify)
3 wire 4 wire
Delta, Corner Grounded
High resistance
Solid Ground Ungrounded
ground
Generator (Generator kW rating) (please specify) ___________________________________________________________________
Distance from
< 250 ft. 251500 ft. 501750 ft. > 750 ft. (please specify) ________________________
Line to starter:
Conductor
Shielded Non-Shielded
type:
Distance from
Starter to < 250 ft. 251500 ft. 501750 ft. > 750 ft. (please specify) ________________________
motor:
Size and
Quantity of Line Side Size: ______________________ Line Side Quantity: __________________/Phase
Conductors:
Load Side Size: ______________________ Load Side Quantity: __________________/Phase

Return to the
3-16 benshaw.com Table of Contents
Medium Voltage Starter Order Check List
SECTION B Motor Data
Type of motor: Induction Synchronous Wound Rotor
__________________
Horsepower:
(If Synchronous or Wound Rotor, see Section E or F for additional questions.)
Other: (please specify)
Motor voltage: 2300 4160 6900 13,800
__________________________
Frequency: 25 Hz 50 Hz 60 Hz Other: (please specify) ________________________
NEMA Design: A B C D E
FLA: _________ Service Factor: ____ Motor LRA: ___________ Motor Speed (RPM): ____________

SECTION C Enclosure / Environment Data


Expected
Minimum: ________________________________ Maximum: ______________________________
ambient
(Space Heater required if less than 0 C)
temperature:
Space heater: Yes No Physical Location: Indoor Outdoor
Size Limitation: _______" High _______" Wide _______" Deep ( please indicate dimensions. )
Altitude: up to 3,300 ft. above 3,300 ft. (please specify) __________________________________
Excessive
Vibration and / Vibration Noise Neither
or Noise:
ANSI 61 Grey Beige Other: (please specify) _________________
Color:
(standard)
Cable Entry
Top (option) Bottom (standard) Cable Exit location: Top (standard) Bottom (option)
location:
Other: (please specify)
Horizontal Bus: NONE (standard) 800 Amp 1200 Amp 2000 Amp
__________________________
Insulation
Yes (price adder) No (standard)
on Bus:
UL Rating
1 3R 12 (standard) Other: (please specify) ________________________
(NEMA Type):

SECTION D Miscellaneous
Disconnect: Fusible Disconnect None
Starting
Keypad (standard) 2-Wire Control 3-Wire Control Other: (please specify) ________________________
Method:
Across-the-
Line Starting Yes No (standard)
Option:

Will any of the Power Factor Correction Capacitors Lightning Arrestors Surge Capacitors
Note: PFCC must be located on the Line side Note: May be placed Note: Must be at the motor terminals and must be isolated
following be on either the Line or during starting to prevent damage.
of the Starter and must be isolated from the
present?: line during starting. Load side of the Starter.

Return to the
Table of Contents 3-17
Engineered Medium
Voltage Starter Products
Medium Voltage Starter Order Check List
SECTION E Synchronous Motor Data:
Normal Field
_________________ Max Field Current: (ADC) _________________
Current: (ADC)
Field Discharge Synchronous Motor Field
_________________ _________________
Resistor Rating: Voltage: (VDC)

SECTION F Wound Rotor Motor Data:


Wound Rotor
Starting Duty Resistor Continuous Running Duty Resistor
Motor:
Quantity
of Steps/ _________________ Present number of steps: _________________
Resistance:
Secondary Secondary Current:
_________________ _________________
Voltage: (VAC) (Amps)

SECTION G Additional Modifications, Accessories and/or Information:


________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________

________________________________________________________________________________________________________________________________

Customers Signature __________________________________________________________

Customers Company __________________________________________________________

Date ______________________________

Return to the
3-18 benshaw.com Table of Contents
Smart Full Voltage ATL Starters
CFMVRMXATL Product Highlights:
The "Smart" Medium Voltage "ATL" package includes the addition of the RediStart MX3 control
Series package for additional branch circuit monitoring motor protection, metering, diagnostics and
communication. Refer to MVRMX RediStart MX3 specification for complete details. A sampling
of the enhanced features includes:

Protection (ANSI standard numbers given)


51Electronic motor overload, class 1 to 40
86Overload lockout
59/27Adjustable over / under voltage protection
46Adjustable line to average current imbalance
81Adjustable high and low frequency protection
Single phase protection
66Adjustable starts per hour (off or 1 to 20 starts)
Adjustable time between starts (off or 1 to 600 minutes)
Backspin timer (off or 1 to 200 minutes)
51Overcurrent detection (off or 50 to 800%) and time (0.1 to 90.0
sec. in 0.1 sec. intervals)
37Undercurrent detection (off or 10 to 100% and time (0.1 to 90.0
sec. in 0.1 sec. intervals)
51GGround fault detection (off or 1 to 100 amps) and time (0.1 to 90.0 sec.
in 0.1 sec. intervals)
Overcurrent, undercurrent and ground fault can each be set to trip or activate a relay
50Instantaneous electronic overcurrent trip
47Phase rotation selectable ABC, CBA or Ins (insensitive)
38/49Remote mountable RTD protection package, 8 or 16 RTD inputs (optional)
Control
Local start / stop controls
Emergency reset capability
Input / Output and Display
Plain English operation via back lit LCD display interface
LCD and LED status and diagnostics (full fault annunciation)
Programmable metering (amps, volts, frequency, overload, power factor, elapsed time,
watts, VARs, watt hours, VA, current imbalance, ground fault current, RTD temperatures
with optional RTD module)
Programmable relay outputs
Latched fault relay output
Real time clock
Time stamped event recorder
Password protection
Battery backed-up starter parameters and lockout times

Return to the
Table of Contents 3-19
Engineered Medium
Voltage Starter Products
Smart Full Voltage ATL Starters
CFMVRMXATL Series

MX3 Control Features (Smart Across the Line)


Motor Protection: Metering, continued: 1 Analog 420 mA / 0-10 VDC
Motor thermal overload kW hours Input Configurable to:
Independent starting and MW hours Trip high level
running OLs Trip low level
Phase order
Low line voltage Line frequency 1 Analog 420 mA / 0-10 VDC
Low line frequency Analog input Output Configurable to:
High line frequency Analog output Current (0200%/0800%)
Phase reversal Run timedays Voltage (0150%)
Phase loss Run timehours OL (0150%)
Instantaneous overcurrent # of starts kW (010 kW/0100 kW)
Overcurrent TruTorque %
MW (01 MW)
Undercurrent Power % Analog input (0100%)
Current imbalance Peak starting current Firing (0100%)
Ground fault Last starting duration Calibration
(residual or zero sequence)
RTD temperatures User Interface:
Disconnect fault
Real-time clock Event log (99 events)
Inline contactor fault
Control power low 8 Digital Inputs Configurable to: Door mounted LCD display
Motor PTC input Stop Set / examine operating parameters

RTD modules Fault View status information, line current,


voltage and frequency
Fault reset
Metering: Start and stop the starter
Bypass / inline confirm
Accuracy:
OL reset 1 Communication Port:
3% out-of-box
Local / remote selection ModBus / RS485
2% factory calibrated
1 dedicated start input
Average current
Disconnect
L1 current
L2 current 6 Relay Outputs Configurable to:
L3 current Faulted
Current imbalance % Running
Ground fault current Up to speed
Average volts Alarm condition
L1L2 voltage Ready condition
L2L3 voltage Locked out
L3L1 voltage Over current
Overload % Under current
Power factor OL alarm
Watts Shunt trip
VA Ground fault
VARS Cooling fan

Return to the
3-20 benshaw.com Table of Contents
Smart Full Voltage ATL Starters
CFMVRMXATL Series

2300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMXATL-500-2300 ** 2300 500 120 92 24 32 $18,750.00 $20,955.00
CFMVRMXATL-1000-2300 ** 2300 1000 240 92 24 32 $19,650.00 $21,875.00
CFMVRMXATL-1500-2300 ** 2300 1500 360 92 24 32 $20,995.00 $23,250.00
CFRMVRMXATL-HP-2300 ** 2300 >1500 >360

3300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMXATL-1000-3300 ** 3300 1000 169 92 24 32 $18,875.00 $21,250.00
CFMVRMXATL-1250-3300 ** 3300 1250 211 92 24 32 $20,500.00 $22,750.00
CFMVRMXATL-1500-3300 ** 3300 1500 254 92 24 32 $20,995.00 $23,250.00
CFMVRMXATL-2000-3300 ** 3300 2000 338 92 24 32 $20,995.00 $23,250.00
CFMVRMXATL-2250-3300 ** 3300 2250 380 92 60 36 $41,555.00 $43,895.00
CFMVRMXATL-2500-3300 ** 3300 2500 423 92 60 36 $41,555.00 $43,895.00
CFRMVRMXATL-HP-3300 ** 3300 >2500 >423

4160 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMXATL-1000-4160 ** 4160 1000 133 92 24 32 $19,250.00 $22,250.00
CFMVRMXATL-2000-4160 ** 4160 2000 266 92 24 32 $19,750.00 $22,750.00
CFMVRMXATL-2500-4160 ** 4160 2500 333 92 24 32 $20,525.00 $23,650.00
CFMVRMXATL-3000-4160 ** 4160 3000 399 92 60 36 $39,995.00 $43,995.00
CFRMVRMXATL-HP-4160 ** 4160 >3000 >399

6900 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVRMXATL-1500-6900 ** 6900 1500 125 92 24 32 $21,250.00 $24,550.00
CFMVRMXATL-2250-6900 ** 6900 2250 187 92 24 32 $23,150.00 $25,375.00
CFMVRMXATL-4000-6900 ** 6900 4000 332 92 24 32 $23,650.00 $25,875.00
CFRMVRMXATL-HP-6900 ** 6900 >4000 >332
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory

OTHER VOLTAGES AVAILABLE PLEASE INQUIRE

Return to the
Table of Contents 3-21
Engineered Medium
Voltage Starter Products
Full Voltage ATL Starters
CFMVATL Series Product Highlights:
CFMVATL medium voltage across-the-line starters are full voltage controllers for three
phase induction motors. The RediStart MX3 control package can be added as an
option to provide a "Smart" CFMVRMXATL package.

Combination CFMVATL starters are supplied in a free standing enclosure. Enclosures


are available in NEMA 1, NEMA 12 and NEMA 3R configurations. Enclosure consists of
two distinct compartments. The medium voltage section is located in the main body
of the enclosure, and the low voltage section containing the control logic is located
behind the door in an isolated compartment.

Standard combination CFMVATL starters are supplied with a load break / fault make
disconnect isolation switch, Class "R" motor current limiting fuses, vacuum motor
starting contactor and the "SPE" SureProtex electronic overload protection. Refer to
the CFMVRMXATL series for the RediStart MX3 control package for additional branch
circuit monitoring, motor protection, metering, diagnostics and communication.

Standard Features:
The standard medium voltage combination "ATL" package includes:

NEMA 1,12, 3R enclosure


Disconnect switch
Load break / fault make
Grounding bar
Viewing window
Motor fusing
Class "R"
Current limiting
Vacuum motor starting contactor
Start / stop push-buttons
"SPE" overload protection
Class 10-30 adjustable
1 N/O, 1 N/C trip contact
"Trip free" design
Phase imbalance protection
Phase reversal protection
Phase loss protection
Test function / trip indication
Fault indication

Return to the
3-22 benshaw.com Table of Contents
Full Voltage ATL Starters
2300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVATL-500-2300 ** 2300 500 120 92 24 32 $14,000.00 $16,885.00
CFMVATL-1000-2300 ** 2300 1000 240 92 24 32 $16,500.00 $18,650.00
CFMVATL-1500-2300 ** 2300 1500 360 92 24 32 $17,500.00 $19,850.00
CFMVATL-HP-2300 ** 2300 >1500 >360

3300 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVATL-1000-3300 ** 3300 1000 169 92 24 32 $14,850.00 $17,000.00
CFMVATL-1250-3300 ** 3300 1250 211 92 24 32 $15,500.00 $17,765.00
CFMVATL-1500-3300 ** 3300 1500 254 92 24 32 $16,855.00 $17,995.00
CFMVATL-2000-3300 ** 3300 2000 338 92 24 32 $17,000.00 $19,150.00
CFMVATL-2250-3300 ** 3300 2250 380 92 60 36 $37,450.00 $39,735.00
CFMVATL-2500-3300 ** 3300 2500 423 92 60 36 $37,500.00 $37,750.00
CFMVATL-HP-3300 ** 3300 >2500 >423

4160 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVATL-1000-4160 ** 4160 1000 133 92 24 32 $15,825.00 $18,000.00
CFMVATL-2000-4160 ** 4160 2000 266 92 24 32 $16,365.00 $18,625.00
CFMVATL-2500-4160 ** 4160 2500 333 92 24 32 $17,250.00 $19,500.00
CFMVATL-3000-4160 ** 4160 3000 399 92 60 36 $37,475.00 $39,750.00
CFMVATL-HP-4160 ** 4160 >3000 >399

6900 V
Dimensions (in.)
NEMA 1/12 NEMA 3R
Model Number V HP FLA H W D List Price List Price
CFMVATL-1500-6900 ** 6900 1500 125 92 24 32 $18,175.00 $20,455.00
CFMVATL-2250-6900 ** 6900 2250 187 92 24 32 $18,985.00 $21,250.00
CFMVATL-4000-6900 ** 6900 4000 332 92 24 32 $19,500.00 $21,775.00
CFMVATL-HP-6900 ** 6900 >4000 >332
** Insert appropriate option code as shown: NEMA 1 = 1 / NEMA 12 = 12 / NEMA 3R = 3R
Consult factory

OTHER VOLTAGES AVAILABLE PLEASE INQUIRE

Return to the
Table of Contents 3-23
Engineered Medium
Voltage Starter Products
Main Lug Only
MLO Series Product Highlights:
Benshaws Main Lug Only (MLO) section provides a full height and depth NEMA rated
NEMA 1 / NEMA 12 enclosure for use as a convenient area to land the line or load cable connections while
providing a transition area for a disconnect switch, starter or an MCC.

The MLO can be configured for top or bottom cable access (specify when ordering).
Customized MLO sections are availablejust contact Benshaws factory with
your requirements.

Key Advantages:
Landing pad for input cable
Optional feed through bus to Benshaw line up
Top or bottom cable entry
NEMA 1, 12 or 3R enclosure configurations
Transition from other manufacturers line up (optional)
Configure to match up to existing bus network (optional)
Optional control transformers and metering can be added
Standard Features:
Landing pad for cabling
NEMA 1/12 construction
ANSI 61 grey
11 gauge steel construction
Super durable polyurethane TGIC powder paint
Tin plated copper bus
Paint finish meets ASTM A252-9 or A525-83
UL listed 5 kV Class
Options:
Bus entry, left or right

Return to the
3-24 benshaw.com Table of Contents
Main Lug Only
2300 V / NEMA 1/12/3R
NEMA 1/12 NEMA 3R
Model Number Description List Price List Price
MV-MLO-18-800-2300* 800 Amp Pull Section 18" Wide Enclosure $7,350.00 $7,725.00
MV-MLO-18-1200-2300* 1200 Amp Pull Section 18" Wide Enclosure $7,875.00 $8,295.00
MV-MLO-18-2000-2300* 2000 Amp Pull Section 18" Wide Enclosure $8,150.00 $8,545.00
MV-MLO-24-800-2300* 800 Amp Pull Section 24" Wide Enclosure $7,925.00 $8,325.00
MV-MLO-24-1200-2300* 1200 Amp Pull Section 24" Wide Enclosure $8,500.00 $8,925.00
MV-MLO-24-2000-2300* 2000 Amp Pull Section 24" Wide Enclosure $8,725.00 $9,155.00

3300 V / NEMA 1/12/3R


NEMA 1/12 NEMA 3R
Model Number Description List Price List Price
MV-MLO-18-800-3300* 800 Amp Pull Section 18" Wide Enclosure $7,350.00 $7,725.00
MV-MLO-18-1200-3300* 1200 Amp Pull Section 18" Wide Enclosure $7,875.00 $8,295.00
MV-MLO-18-2000-3300* 2000 Amp Pull Section 18" Wide Enclosure $8,150.00 $8,545.00
MV-MLO-24-800-3300* 800 Amp Pull Section 24" Wide Enclosure $7,925.00 $8,325.00
MV-MLO-24-1200-3300* 1200 Amp Pull Section 24" Wide Enclosure $8,500.00 $8,925.00
MV-MLO-24-2000-3300* 2000 Amp Pull Section 24" Wide Enclosure $8,725.00 $9,155.00

4160 V / NEMA 1/12/3R


NEMA 1/12 NEMA 3R
Model Number Description List Price List Price
MV-MLO-18-800-4160* 800 Amp Pull Section 18" Wide Enclosure $7,350.00 $7,725.00
MV-MLO-18-1200-4160* 1200 Amp Pull Section 18" Wide Enclosure $7,875.00 $8,295.00
MV-MLO-18-2000-4160* 2000 Amp Pull Section 18" Wide Enclosure $8,150.00 $8,545.00
MV-MLO-24-800-4160* 800 Amp Pull Section 24" Wide Enclosure $7,925.00 $8,325.00
MV-MLO-24-1200-4160* 1200 Amp Pull Section 24" Wide Enclosure $8,500.00 $8,925.00
MV-MLO-24-2000-4160* 2000 Amp Pull Section 24" Wide Enclosure $8,725.00 $9,155.00

6900 V / NEMA 1/12/3R


NEMA 1/12 NEMA 3R
Model Number Description List Price List Price
MV-MLO-18-800-6900* 800 Amp Pull Section 18" Wide Enclosure $7,350.00 $7,725.00
MV-MLO-18-1200-6900* 1200 Amp Pull Section 18" Wide Enclosure $7,875.00 $8,295.00
MV-MLO-18-2000-6900* 2000 Amp Pull Section 18" Wide Enclosure $8,150.00 $8,545.00
MV-MLO-24-800-6900* 800 Amp Pull Section 24" Wide Enclosure $7,925.00 $8,325.00
MV-MLO-24-1200-6900* 1200 Amp Pull Section 24" Wide Enclosure $8,500.00 $8,925.00
MV-MLO-24-2000-6900* 2000 Amp Pull Section 24" Wide Enclosure $8,725.00 $9,155.00
*Complete model number by adding suffix to specify NEMA 1, 12 or 3R enclosure: -1, -12 or -3R.

OTHER VOLTAGES AVAILABLE PLEASE INQUIRE

Return to the
Table of Contents 3-25
Engineered Medium
Voltage Starter Products
Load Interrupter Switch
CFMVDISC Series Product Highlights:
Benshaws free standing medium voltage load break interrupter switch is the latest design in
medium voltage high current switching equipment for a wide range of applications. The fused
interrupter switch provides an economical means of disconnect and short circuit protection of
medium voltage loads such as transformers, single circuit or multi-circuit systems.

The switch is provided in a NEMA 12 rated enclosure configured for use as a standalone unit,
in an equipment line-up or MCC.

Key Advantages:
Bolts directly to Benshaw MCC line-up or starter
UL labeled up to 4800 volts
Available in 400, 600 and 1200 amp ratings
Available up to 6600 volts
Class E fusing included
Configurable with added options
Load break rated
Standard Features:
Load break fault make
60 kV BIL up to 7.2 kV
Symmetric fault ratings of 50 kA for 5 kV7.2 kV and 45 kA for 2.4 kV
NEMA 12 enclosure
Viewing window to verify switch position
Enclosure MV door interlocked with switch mechanism to prevent
access while switch is on
Operating mechanism lockable in the off position
Load side grounding in off position
Blown fuse indication
Welded 11 gauge steel construction
Enclosure finish meets ASTM A252-9 or A525-83, G-90 designation
Line and load landing pads with NEMA bolt pattern
Options:
Lockable front panel
Bus entry, left or right

Return to the
3-26 benshaw.com Table of Contents
Load Interrupter Switch
CFMVDISC Series

2300 V
Dimensions (in.)
Model Number Description H W D List Price
CFMV-DISC-24-400-2300-12 * MV Disc Switch 400A 2300V Top Entry / Bottom Exit 92 24 30 $17,250.00
CFMV-DISC-36-600-2300-12 * MV Disc Switch 600A 2300V Bottom Entry / Top Exit 92 36 36 $25,955.00
CFMV-DISC-36-1200-2300-12 * MV Disc Switch 1200A 2300V Bottom Entry / Top Exit 92 36 36 $27,750.00

3300 V
Dimensions (in.)
Model Number Description H W D List Price
CFMV-DISC-24-400-3300-12 * MV Disc Switch 400A 3300V Top Entry / Bottom Exit 92 24 30 $17,250.00
CFMV-DISC-36-600-3300-12 * MV Disc Switch 600A 3300V Bottom Entry / Top Exit 92 36 36 $25,955.00
CFMV-DISC-36-1200-3300-12 * MV Disc Switch 1200A 3300V Bottom Entry / Top Exit 92 36 36 $27,750.00

4160 V
Dimensions (in.)
Model Number Description H W D List Price
CFMV-DISC-24-400-4160-12 * MV Disc Switch 400A 4160V Top Entry / Bottom Exit 92 24 30 $17,250.00
CFMV-DISC-36-600-4160-12 * MV Disc Switch 600A 4160V Bottom Entry / Top Exit 92 36 36 $25,955.00
CFMV-DISC-36-1200-4160-12 * MV Disc Switch 1200A 4160V Bottom Entry / Top Exit 92 36 36 $27,750.00

6600 V
Dimensions (in.)
Model Number Description H W D List Price
CFMV-DISC-24-400-6600-12 ** MV Disc Switch 400A 6600V Top Entry / Bottom Exit 92 24 30 $18,250.00
CFMV-DISC-36-600-6600-12 ** MV Disc Switch 600A 6600V Bottom Entry / Top Exit 92 36 36 $33,500.00
CFMV-DISC-36-1200-6600-12 ** MV Disc Switch 1200A 6600V Bottom Entry / Top Exit 92 36 36 $41,650.00
See page 3-35 for available options. Options include horizontal bus, kirk key interlock and Main Lug Only (MLO) sections.
* For use on motor load Class R fuse will be provided and must be specified by customer.
** Non UL listed disconnect switch.

OTHER VOLTAGES AVAILABLE PLEASE INQUIRE

Return to the
Table of Contents 3-27
Engineered Medium
Voltage Starter Options
Pilot Devices
Push-Buttons
Option Code Description List Price
A001 Raised Stop Push-Button - Red $100.00
A002 Flush Start Push-Button - Green $100.00
A003 Jog Push-Button - Yellow $100.00
A004 OL Reset Push-Button - (For External OL Relay) - Black $100.00
A005 Reset Push-Button - Black $100.00
A006 Raised Push-Button - Specify Color And Function $100.00
A007 Flush Push-Button - Specify Color And Function $100.00
A008 Mushroom Head Stop Push-Button - Red $150.00
A009 Illuminated Push-Button - Specify Color And Function $175.00

Pilot Lights
Option Code Description List Price
A021 Red Run Light $125.00
A022 Green Stop Light $125.00
A023 Amber Fault Light $125.00
A024 Green Ready Light $125.00
A025 Amber Bypass Light $125.00
A026 Red Light - Specify Function $125.00
A027 Green Light - Specify Function $125.00
A028 Amber Light - Specify Function $125.00
A029 White Light - Specify Function $125.00
A030 Blue Light - Specify Function $125.00
A031 Push To Test Contact Assembly (Addition to Above) $200.00

Return to the
3-28 benshaw.com Table of Contents
Pilot Devices
Selector Switches
Option Code Description List Price
A041 Hand - Off - Auto Selector Switch $175.00
A042 Local - Off - Remote Selector Switch $175.00
A043 Key-Operated Hand - Off - Auto Selector Switch $150.00
A044 Dual Ramps Selector Switch $150.00
A045 Two-Postion Selector Switch - Specify Function $200.00
A046 Three-Position Selector Switch - Specify Function $200.00
A047 Other Selector Switch - Specify Function and Type
Consult factory

Meters
Option Code Description List Price
A061 Single-Phase Analog Ammeter - Includes CTs * $1,200.00
A062 Analog Ammeter with Three-Phase Selector Switch - Includes CTs * $1,500.00
A065 Elapsed Time Meter $250.00
A066 Operations Counter $250.00
A069 Other Power Metering - Specify Function
A075 Analog Voltmeter, Single Phase * $3,500.00
A076 Analog Voltmeter with Three-Phase Selector Switch * $3,750.00
A077 AC Wattmeter
A078 AC Watt Hour Meter
* Switchboard type
Consult factory

Return to the
Table of Contents 3-29
Engineered Medium
Voltage Starter Options
Control Options
MX3 Options
Option Code Description List Price
A401 Door Mounted Communications Package - Includes Door Mounted Connector and RS232 / 485 Card $650.00
MXCOMPA343 Profibus Communications Bridge
MXCOMEA345 Ethernet Communications Bridge
MXCOMDA344 DeviceNet Communications Bridge
A405 Power Outage Ride-Thru - This Option Allows the Starter to Automatically Restart after a Power Loss $500.00
of up to 30 Secs. Customer Must Supply Separate Source of Uninterrupted 120 V to the Starter
A406 RTD Module - Unit Will Accept 8 Input RTDs. RTDs must be 100 ohm Platinum. (Available for Remote $3,000.00
Mounting; Consult Factory for Details)
A407 RTD Module - Unit Will Accept 16 Input RTDs. RTDs must be 100 ohm Platinum. (Available for Remote $5,000.00
Mounting; Consult Factory for Details)
A411 1000 VA UPS / 700 W for 120V Supply Instead of Customer Supplied for Option A405 Power Outage $3,000.00
Ride-Thru
Consult factory

Emergency Start Options


Option Code Description List Price
A410 Emergency / Across the Line Bypass Option, Includes Start / Stop Push-Buttons, Overload Relay $1,500.00
and Current Transformers and Selector Switch
Consult factory

Control Power Transformers


Option Code Description List Price
A105 500 VA Additional Control Power $725.00
A106 1000 VA Additional Control Power $850.00
A107 Specify Control Power Amount
A110 1500 VA Additional Control Power $2,000.00
A111 2500 VA Additional Control Power $2,500.00
Consult factory

General Purpose Control Relays


Option Code Description List Price
A121 Three-Pole Relay - Specify Function $225.00
A122 Four-Pole Relay - Specify Function $275.00
A123 Other Relays - Specify Function and Type
A124 On Delay Timer - Specify Function and Time $300.00
A125 Off Delay Timer - Specify Function and Time $300.00
A126 Other Timers - Specify Function and Time
A127 Ground Fault Relay - For Equipment Protection Only $1,500.00
Consult factory

Transducers
Option Code Description List Price
A141 Transducer Output 05 VDC Based on Motor FLA $650.00
A142 Transducer Output 420 mA Based on Motor FLA $650.00
A145 Transducer Output 420 mA Based on Motor Voltage
Consult factory

Return to the
3-30 benshaw.com Table of Contents
Motor Protective Relays
The following protective relays include the necessary current and potential transformers included.
For optional zero sequence ground fault sensing, the appropriate current transformer should be added.

Protective Relays
Option Code Description List Price
A826 Multilin 369 with RTD, Metering and Communications Options
A827 Multilin 469
A829 Multilin PQM II with Analog Output Options
A830 Cutler Hammer MP4000
A831 Schweitzer SEL 710
A832 Schweitzer SEL 749M
A838 Other
Consult factory

Protective Relay Options


Option Code Description List Price
A875 Ground Fault CT, 2000:1, 4.0:Dia. (For MX3 Use) $350.00
A876 Ground Fault CT, 2000:1, 8.13:Dia. (For MX Use)
3
$1,000.00

Return to the
Table of Contents 3-31
Engineered Medium
Voltage Starter Options
Enclosure and Bus Options
Enclosure Options
Option Code Description List Price
A171 Space Heater With Thermostat $450.00
A251 Door Interlock Switch $275.00
A252 Single Key Kirk Key Interlock $650.00
A255 Multiple Enclosure Mechanical Door Interlock
A256 Enclosure Upsizing - 24" W to 36" W $1,000.00
A257 Enclosure Upsizing - 36" W to 45" W $1,000.00
A258 Enclosure Upsizing - 32" D to 36" D $1,000.00
Consult factory

Bus Splice Options (must match bus option selected)


Option Code Description List Price
8N 800 A Non-Insulated Bus Splice $395.00
8I 800 A Insulated Bus Splice $625.00
1N 1,200 A Non-Insulated Bus Splice $499.00
1I 1,200 A Insulated Bus Splice $725.00
2N 2,000 A Non-Insulated Bus Splice $850.00
2I 2,000 A Insulated Bus Splice $1,050.00
NR None Required $0

Bus Options*
Option Code Description 0 to 1,500 HP 1,500 to 3,000 HP
8N 800 A Non-Insulated Bus $1,500 $1,750
8I 800 A Insulated Bus $2,150 $2,195
1N 1,200 A Non-Insulated Bus $1,750 $1,850
1I 1,200 A Insulated Bus $2,500 $2,555
2N 2,000 A Non-Insulated Bus $2,750 $2,795
2I 2,000 A Insulated Bus $3,795 $3,850
NR None Required $0 $0
Bus not required for single stand-alone unit.
+

Bus is required for connection of 2 or more units.


Any unit with bus greater than 36 will require additional MLO section. Please contact the factory for pricing and delivery.

Return to the
3-32 benshaw.com Table of Contents
Power Factor Correction Capacitors
Power factor correction capacitors (PFCCs) are available
in two options.
1. If the starter requires a UL label, the power factor capacitors are installed on the top of
the unit (capacitors are shipped loose and must be installed by customer) or in a separate
enclosure to be installed next to the starter. The top mount will add approximately 28
inches to the enclosure height. Top mount is only available up through 225 kVAR, 4.8 kV.
The separate enclosure (dimensions: 92"Hx30"Wx36"D) can house up to 2 PFCC units.
For remote mount, contact factory.

2. For units not requiring UL approval, capacitors may be installed inside the enclosure.
Both options require enclosure width to increase to the next standard size to accommodate
the added contactor. Capacitors are three phase, supplied with three fuses, rated for
60 Hz operation.

PFCCs are available for voltages up through 13.8 kV.

Available Sizes:
25 kVAR increments for 2.3 kV through 4.8 kV, starting at 25 kVAR
50 kVAR increments for 6 kV through 13.8 kV, starting at 50 kVAR
Consult factory for dimensions.

Information Required for Sizing


(Note: Industry standard is to correct to a 0.95 PF.)

1. Motor HP:______________________________

2. Voltage:________________________________

3. Existing Power Factor:___________________

4. Corrected Power Factor:_________________

Return to the
Table of Contents 3-33
Engineered Medium
Voltage Starter Options
Surge / Lightning Arrestors
The surge or lightning arrestors are available in two options. If the unit is required to be UL approved, the surge arrestors must be installed on the
top of the unit (components are shipped loose and must be installed by customer). This will add eighteen inches to the height of the enclosure.
For units not requiring UL approval, the arrestors may be installed inside the enclosure. This requires the enclosure width to increase to the next
standard size. Includes the hardware necessary to mount and wire the arrestors and the increased size of the enclosure where required.

Non-UL Labeled Starter Inside Mount


Option Code Description List Price
A901 Surge Arrestor, 2300 VAC $2,000.00
A902 Surge Arrestor, 3300 VAC $2,000.00
A903 Surge Arrestor, 4160 VAC $2,000.00
A904 Surge Arrestor, 4800 VAC $2,000.00
A905 Surge Arrestor, 6900 VAC $2,500.00
A906 Surge Arrestor, 9000 VAC $2,500.00
A907 Surge Arrestor, 12000 VAC $3,000.00

UL Labeled Starter Top Mount - 18" Height Adder (18"H x 30"W x 24"D top hat shipped loose)
Option Code Description List Price
A925 Surge Arrestor, 2300 VAC $2,250.00
A926 Surge Arrestor, 3300 VAC $2,250.00
A927 Surge Arrestor, 4160 VAC $2,375.00
A928 Surge Arrestor, 4800 VAC $2,375.00
A929 Surge Arrestor, 6900 VAC $2,500.00
A930 Surge Arrestor, 9000 VAC $2,500.00
A931 Surge Arrestor, 12000 VAC $3,000.00

Return to the
3-34 benshaw.com Table of Contents
Surge Capacitors
Surge capacitors will be supplied in a top hat package for starters that must maintain the UL label. This will add to the height of the enclosure
(components are shipped loose and must be installed by customer). For non-UL units, the capacitors are packaged into the unit, which increases
the width of the enclosure up to the next standard size.

Non-UL Labeled Starter Inside Mount


Option Code Description List Price
A950 Surge Capacitor, 2300 VAC
A951 Surge Capacitor, 3300 VAC
A952 Surge Capacitor, 4160 VAC
A953 Surge Capacitor, 4800 VAC
A954 Surge Capacitor, 6900 VAC
A955 Surge Capacitor, 9000 VAC
A956 Surge Capacitor, 15 kV
Consult factory

UL Labeled Starter Top Mount - 18 Height Adder (18H x 30W x 24D top hat shipped loose)
Option Code Description List Price
A975 Surge Capacitor, 2300 VAC
A976 Surge Capacitor, 3300 VAC
A977 Surge Capacitor, 4160 VAC
A978 Surge Capacitor, 4800 VAC
A979 Surge Capacitor, 6900 VAC
A980 Surge Capacitor, 9000 VAC
A981 Surge Capacitor, 15 kV
Consult factory

Return to the
Table of Contents 3-35
Engineered Medium
Voltage Starter Options
Line Reactors
For 2.4 kV solid state starters, line reactors are not required.

For 5 kV / 7.2 kV solid state starters, line reactors are required when the supply source transformer is greater than 20 MVA (5% Impedance) or the
motor lead wiring length is 1,000 feet or greater. For systems with custom motor control lineups and power factor correction capacitors, consult
the factory.

For 13.8 kV starters, consult factory for the requirement of line reactors.

The line reactors are available in two options. If the unit is required to be UL approved, the reactors must be installed on the top of the unit
(reactors are shipped loose and must be installed by customer). This will add to the height of the enclosure. For units not requiring UL approval,
the reactors may be installed inside the enclosure. The inside mounting requires the enclosure width to increase to accommodate the added
reactor. The price includes the hardware necessary to mount and wire the reactors and the increased size of the enclosure where required.

A de-tuning reactor may be required to protect the power system from the adverse interaction of capacitors and non-linear loads. To ensure
the power factor correction device is properly applied, consult a qualified engineer or provide your single line electrical diagrams to Benshaw
for evaluation.

4,160 V Starter Inside Mount


Option Code HP List Price
A985 750
A986 1500
A987 3000
A988 >3000
Consult factory

4,160 V UL Labeled Starter Top Mount


Dimensions (in.)
Option Code HP H W D List Price
A991 750 22 22 24
A992 1500 23 24 24
A993 3000 23 24 24
A994 >3000
Consult factory on other voltage ratings in the 5 and 7.2 kV class.
Consult factory

Return to the
3-36 benshaw.com Table of Contents
Documentation
Benshaw offers a variety of documentation options to fit your project scope, budget and timeline. Only Benshaw offers the flexibility in our
approval process to help meet our customers project schedules. All of our documentation packages are processed through our highly technical
engineering department. Please contact Benshaw for pricing and delivery. Please ensure all documentation requirements are on the purchase
order. Electronic copies are provided unless hard copies are specified on the purchase order.

Preliminary Drawings Full Submittals


Preliminary drawings consist of the released to manufacturing Full submittal packages ensure that no equipment will be purchased
drawings that are used in production. This drawing package does not for the project until the customers approval for production is received.
include any form of customer approvals. The drawing package includes The full submittal package includes the internal and external layout,
the internal and external layout, and schematics. schematics and cut sheets for major components.

Partial Approvals As-Built Drawings


Partial approval drawings allow Benshaw to purchase long-lead items As-built drawings are typically sent out two weeks after shipment and
that will not change prior to the customers approvals. This allows incorporate all the changes that occur during the production process,
Benshaw to cut down on the delivery time while still allowing the testing and FAT test (if applicable).
customer all the flexibility and control in an approval process. The
partial approval package includes the internal and external layout, O&M Manuals
and schematics. O&M manuals are typically sent out four weeks after delivery.
O&M manuals also include as-built drawings.
Full Approvals
Full approval drawings ensure that no equipment will be purchased Witness Testing (FAT Testing)
for the project until the customers approval for production is received. Witness testing includes a testing plan and procedure that must
The full approval package includes the internal and external layout, be reviewed and approved in advance by the customer. Quotations
and schematics. are for standard Benshaw testing, and any special testing needs or
requirements must to be brought up to Benshaw to ensure accurate
Partial Submittals scheduling. Witness testing can occur starting the week after the
Partial submittal packages allow Benshaw to purchase long-lead equipment is ready to ship, adding to the delivery time frame,
items that will not change prior to the customers approvals. This and must be scheduled beforehand.
allows Benshaw to cut down on the delivery time while still allowing
the customer all the flexibility and control in an approval process.
The partial submittal package includes the internal and external
layout, schematics and cut sheets for major components.

Return to the
Table of Contents 3-37
Engineered Medium
Voltage Starter Options
Wound Rotor Starters
RATINGS Product Highlights:
Wound rotor motors are typically used in applications requiring high starting torques, a limited
Horsepower: number of operating speeds or a stepped acceleration to achieve a soft start. Typical existing
applications utilize an electromechanical starter on the stator and introduce multiple stages of
1,00010,000 HP* resistance in the rotor via contactor arrangements to achieve a soft ramp.

With the RediStart MX3, wound rotor control is greatly simplified. The RediStart consists of
Overload: two major sections: 1) A solid-state stator control, and 2) secondary resistors into the rotor
500% for 30 seconds circuit from a separate 3-phase resistor bank. This achieves the high torque required by the
applicationwith low inrushwhile providing a smooth stepless start. This greatly reduces
125% continuous
the maintenance cost of the typical electromechanical control.

Starting Torque: Single Step Rotor Control: The solid-state starter is wired to the motor stator circuit, and
the resistor and shorting contactor are wired to the motor rotor circuit. The solid state starter
0100% accelerates the motor to slip speed (determined by the resistance value) and then activates
the contactor to short the rotor. This allows the motor to accelerate to full speed.
Voltage: Multiple Step Rotor Circuit: WR RVSS series starters can be supplied with multiple stages of
2.4, 3.3, 4.1 and 6.6 kV** rotor resistor and contactor combinations. This arrangement may be necessary for multiple step
starting of extremely high inertia loads, or for continuous operation at multiple speeds. Multiple
steps of rotor resistance can be coordinated to achieve this.
Typical Resistance Steps:
Variable Speed Control: Variable speed control of wound rotor motors can be accomplished
12 with the RediStart series control. By maintaining full output voltage of the control going to
the stator of the wound rotor motor, and varying the resistance in the rotor, variable speed
* Consult factory for higher HP rating. is accomplished.
** Consult factory for higher voltage rating.
Resistors must be rated for continuous duty operations. Variable loads (pumps and fans) only.

Key Advantages:

Benshaw MX3 technology Modbus capable


Single step rotor control Configurable output relays
Modular power stack design for ease Multistep & variable speed
of maintenance rotor control available
Integral bypass contactor design Reduced maintenance
Advanced MX3 motor protection Reduced in size and number
of resistors needed
Advanced MX metering function
3

Stepless control
Real time clock
Reduces inrush while maintaining torque
99 event log history

Return to the
3-38 benshaw.com Table of Contents
Wound Rotor Motor Starter Check List
Present starting
Across the line Other ___________________________________
method
Rotor circuit Present number of steps of Total starting ohm value
information resistance ____________ ____________ ohms
Current
method of
Step one ____________ sec. Step two _________ sec. Step three______ sec. Step four _____ sec. Step five ____ sec.
resistance
shorting
The present number of steps may be more or less than listed above. Please specify.
Motor Primary Secondary
information voltage______________ voltage_______________
Primary Secondary
amps________________ amps_________________
Service
RPM ________________
Factor________________
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________

Return to the
Table of Contents 3-39
Engineered Medium
Voltage Starter Options
Synchronous Starters
SEP Series Product Highlights:
The sync motor functions as an induction motor during start up. Once the motor
approaches full synchronous speed, the Redistart DC exciter induces a constant
RATINGS polarity to the rotor causing the motor to lock into sync. Because the rotors field
is constant and separately excited there is no slip required to produce torque,
as with an induction motor. This allows the motor to run at synchronous speed.
Horsepower:
The Benshaw synchronous package consists of a solid state starter portion connected
1,00010,000 HP* to the stator and an SEP (synchronous excitation package) that is connected to the
rotor section in conjunction with a discharge resistor. This SEP is supplied for brush
Overload: type and brushless exciters.

500% for 30 seconds Synchronous Benefits:


125% continuous The RediStart series solid state starter provides reduced voltage stepless acceleration
and automatic synchronization of three phase AC synchronous motors. Synchronous
Starting Torque: motors are utilized for a number of reasons. They are used in applications that require
precise motor speed, they are used to obtain greater efficiencies, and they are used
0100% for facility power factor correction.

Since synchronous motors can be operated at leading power factor, they are used
Voltage:
to correct a facilitys lagging power factor created by all the other induction motors
2.4, 3.3, 4.1 and 6.6 kV** being operated.

This correction reduces the penalty a customer pays the utility company for creating
Exciter Ratings: poor power factor.
125250 VDC Key Advantages:
30120 A***
Benshaw synchronous technology Modbus communication
* Consult factory for higher HP rating. Solid state synchronous rotor control Configurable output relays
** Consult factory for higher voltage rating. Modular power stack design Reduced maintenance
*** Consult factory for higher amp rating. for ease of maintenance
Reduction in size compared
Integral bypass contactor design to existing field control
Advanced synchronous Stepless control
motor protection
Reduces inrush while
Can be added to existing equipment maintaining torque
Can be supplied with MX or MX
2 3
Brush type and brushless control
starter control

Return to the
3-40 benshaw.com Table of Contents
Synchronous Motor Starter Check List
Present starting
Across the line Other ______________________ Application _______________________
method
Field discharge resistor value____________ohms
Motor
Motor horsepower__________ Motor frequency ________Hz
information
Field voltage_______________ Max field current __________
Full load current____________ Motor LRA________________ Motor voltage________
RPM______________________ Service Factor_____________
Motor Wk2 ________________ Load Wk2_________________ Motor Speed ____RPM
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Brushless exciter Brush Type exciter
Options : Circuit Breaker Fusible Switch No disconnect needed
Bypass contactor run duty only
120 VAC control power by Benshaw
Start Stop Pushbutton
Hand Off Auto Local Off Remote 2-Wire Control 3-Wire Control

Return to the
Table of Contents 3-41
MX3 intelligent motor control centers,

Benshaw can custom configure intelligent, MX3 based motor starters, complete
control centers and lineups to meet the needs of any load, in any industry.

Incoming Sections: Custom Configured Multiple Intelligent MCC Integration:


Main breakers or disconnects Unit MCC Lineups: Easy MCC networking
Main-Tie-Main arrangements Transition sections to MTMS, disconnects, feeders,
third party equipment SSRV, ATL, PAM, 2 speed starters
Main lug only sections
800 / 1200 / 2000 / 3000 amp Diagnostics and communications
1200 / 2000 / 3000 amp circuit breakers horizontal bus
Intelligent SSRVS power poles
400 / 600 / 1200 amp load break fault Reduced voltage / full voltage /
make disconnects feeder controls
Surge protection devices Back to back construction
Metering and communications

Return to the
3-42 benshaw.com Table of Contents
lineups, and main-tie-main arrangements

Fused Disconnect
MTM 7.2 kV motor Fixed Mount Circuit
control center with Breaker MTM
integrated power (only 48" deep)
factor correction

Draw Out Circuit Breaker MTM with (6) 5 kV solid state starters
48" space savings
vs. typical 96"
competitive unit

Integrated Supervisory Control and Predictive Packaged Electrical and Control Systems
Maintenance Systems: Benshaw can also design and manufacture completely
In applications requiring the coordination and control of packaged portable or stationary electrical systems for
multiple RediStart starters and third party equipment, applications requiring self-contained modules, including:
Benshaw has the experience and technology to design 20- or 40-foot containers
and deliver integrated control systems:
Self-contained air conditioning and lighting
PC-based systems
Low and medium voltage equipment
Local area networks
Remote monitoring and control
Local / remote communications and control
Personnel and support facilities
Data collection and monitoring
PLC design, programming and integration
Online and offline predictive maintenance

Return to the
Table of Contents 3-43
Mission critical reliability Industry Experience:
Aggregate and mining

in any configuration Cement production


Chemical processing
Municipal fresh and
waste water treatment
Oil and gas production
Power generation
Pulp and paper production
Steel and aluminum

Application Experience:
Low profile skid mounted
Ball / hammer / rolling mills
Centrifuges
Chillers
Compressors
Conveyors
Crushers / hydra pulpers
Fans and blowers
Mixers and refiners
Pumps
Motor control
center with power
factor correction

Protective relays
and PLC logic

20 MW, 13.8 kV

When it absolutely has to work,


it absolutely has to be Benshaw. Fixed-mount circuit Upright skid mounted
breaker MTM

Return to the
3-44 benshaw.com Table of Contents
Low Voltage Starters

Standard Low Voltage Starter Products


Intelligent Motor Control....................4-2

Open Chassis Solid State Starters....... 4-7

Prepackaged Starters
with ATL Bypass................................4-16

Prepackaged Starters........................4-18

Engineered Low Voltage Starter Products


Wound Rotor Starters.......................4-24

Wound Rotor Motor Starter


Check List..........................................4-25

Synchronous Starters.........................4-26

Synchronous Motor Starter


Check List.......................................... 4-27

Solid State Starters


with Reversing Control......................4-28

Solid State Starters


with Two Speed Control....................4-29

Solid State Starters


Part Number Assembler....................4-30

Return to the
Table of Contents 4-1 4-1
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 3 Controller

Fiber Optic Firing Product Highlights:


Integrated technology Next generation MX3 technology forms the backbone of Benshaws entire line
Noise immunity of intelligent medium voltage motor controls. With fiber optic firing, enhanced
programming capabilities, ease of use and a unique, flexible architecture, Benshaws
High voltage isolation
MX3 controller delivers unprecedented functionality and all of the rugged, dependable
Safe, reliable SCR control performance youve come to expect from the world leader in solid state motor
controls and drives.

MX3 controllers, power components, software and sensors are all designed, built
and tested to perform as an integrated control system, eliminating the coordination
and performance problems inherent in other forms of reduced voltage starting.

With more built-in features, more configurable options, greater expandability and
a broader communications capability than any other motor control on the market,
Benshaws next generation MX3 technology will shorten your commissioning times,
improve motor performance and protection, enhance diagnostic capability and
streamline many electrical system monitoring and maintenance tasks.

Key Features:
Keypad (Included)
High performance motor control with multiple starting modes built-in
Patented CYCLO Converter control from 1 to 40% speed
Flexible, programmable I/O
Integrated motor protection
Line and motor metering
Diagnostic capabilities with event log and real-time clock
UL, CUL, NEC, NEMA compliance
Built-in remote self-testing (BIST)
Expanded communications capabilities
Optional RTD Modules Intelligent SCR power poles
Intelligent MV MCC integration

Return to the
4-2 benshaw.com Table of Contents
Intelligent Motor Control
Control Features
Multiple Starting Modes: Metering: 8 Digital Inputs 1 Analog 420 mA /
Voltage ramp Accuracy: Configurable to: 010 VDC Input
Current ramp 3% out-of-box Stop Configurable to:
Adjustable initial current 2% factory calibrated Fault Trip high level
Adjustable maximum Average current Fault reset Trip low level
current Bypass / inline confirm
L1 current 1 Analog 420 mA /
Adjustable ramp time OL reset 010 VDC Output
L2 current
Torque ramp (TruTorque) Local / remote selection Configurable to:
L3 current
Adjustable initial torque Heater enable Current (0200%/0800%)
Current imbalance %
Adjustable maximum Heater disable Voltage (0150%)
Ground fault current
torque
Average volts Dual ramp selection OL (0150%)
Adjustable ramp time
L1L2 voltage 1 dedicated start input kW (010 kW/0100 kW)
Power ramp
L2L3 voltage Disconnect MW (01 Mw)
Adjustable initial torque
L3L1 voltage Slow speed Analog input (0100%)
Adjustable maximum
torque Overload % Brake enable Firing (0100%)

Adjustable ramp time Power factor Brake disable Calibration

Linear / tach feedback control Watts 6 Relay Outputs User Interface:


CYCLO converter control VA Configurable to: Event log (99 events)

Motor Protection: VARS Faulted Door mounted LCD display

Motor thermal overload KW hours Running Set / examine operating


parameters
Independent starting MW hours Up to speed
View status information,
and running OLs Phase order Alarm condition
line current, voltage
Up to speed timer exceeded Line frequency Ready condition and frequency
Low line voltage Analog input Locked out Start and stop the solid
Low line frequency Analog output Over current state starter

High line frequency Run timedays Under current 1 Communication Port:


Phase reversal Run timehours OL alarm ModBus / RS485
Phase loss # of starts Shunt trip Advanced Functionality:
Instantaneous overcurrent TruTorque %
Ground fault Dual ramp selection
Overcurrent Power % Energy saver indication Adjustable kick current
Undercurrent Peak starting current Heating indication Programmable decel modes
Current imbalance Last starting duration Slow speed forward / reverse MV BIST test (built-in self test)
Ground fault (residual RTD temperatures DC braking
or zero sequence)
Real-time clock Cooling fan
Shorted or open SCR
Disconnect fault
Inline contactor fault
Control power low
Stack over temperature
Motor PTC input
RTD modules

Return to the
Table of Contents 4-3
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 2 Controller Product Highlights:
The new MX2 control technology from Benshaw provides a powerful, flexible,
intelligent low voltage motor control platform. MX2-based controls offer multiple,
user selectable starting modes, an increased selection of configurable digital and
analog I/Os, comprehensive built-in metering capabilities, unprecedented onboard
protection and an easy to use, intuitive user interface.

The new control board terminal configurationcoupled with programmable


burden CT settingsmakes Benshaws MX2 technology an excellent choice
for a wide range of intelligent, soft start motor control applications.

With more built-in starting modes, more built-in protection features, additional
communications capabilities, improved noise immunity, a more complete user I/O
and CE compliance, Benshaws new MX2-based low voltage motor controls raise
the bar for intelligent, low-cost, soft start motor control.

When you factor in our 24/7 comprehensive technical support, we think youll find
Benshaws MX2-based controls to be an excellent value.
Keypad
Standard Features:
High performance motor control Power stack thermistor
with multiple starting modes built in
Data snapshot of each fault
Jogging 7% and 14% speed Power up on start
3 user configurable digital inputs 1000V capable
2 fixed inputs for start Energy saver
and bypass confirm
Remote keypad ready
3 user configurable output relays
and 1 fixed bypass confirm CE, UL, CUL, NEMA compliance
User configurable analog I/O Built-in self-testing (BIST)
Programmable burden CT settings ModBus 485 plus expanded
communications capabilities
Residual ground fault with optional bridges
Advanced line / motor metering
DC braking light duty

MX2 Board

Return to the
4-4 benshaw.com Table of Contents
Intelligent Motor Control
Control Features
Multiple Starting Modes: Metering: 3 Digital Inputs 1 Analog 420 mA /
Voltage ramp +/- 2% accuracy Configurable to: 010 VDC Input
Current ramp Average current Stop Configurable to:
Adjustable initial current L1 current Fault Trip high level
Adjustable maximum L2 current Fault reset Trip low level
current Bypass / confirmation
L3 current 1 Analog 420 mA /
Adjustable ramp time & inline
Current imbalance % 010 VDC Output
Torque ramp (TrueTorque) OL reset Configurable to:
Ground fault amps/residual
Adjustable initial torque Local / remote selection Current (0200%/0800%)
Average volts
Adjustable maximum Heater enable Voltage (0150%)
L1L2 voltage
torque Heater disable
L2L3 voltage OL (0150%)
Adjustable ramp time Dual ramp selection
L3L1 voltage kW (010 kW/0100 kW)
Power ramp 1 dedicated start input
Overload % MW (01 MW)
Adjustable initial torque 1 dedicated bypass
Power factor Analog input (0100%)
Adjustable maximum
torque Watts 3 Relay Outputs Firing (0100%)
VA Configurable to: Calibration
Adjustable ramp time
Starter off
Linear / tach VARS User Interface:
feedback control Faulted fail safe
KW hours Standard board-mounted
and non fail safe
Jogging 7% and 14% speed LED interface
MW hours
Running
Motor Protection: Optional remote mount
Phase order
Up to speed LCD display
Motor thermal overload Line frequency
Alarm condition Set / examine operating
Independent starting Analog input parameters
and running OLs Ready condition
Analog output View status information
Up to speed timer exceeded Locked out
Run timedays View line current, voltage
Low line voltage Over current trip
Run timehours and frequency in real time
Low line frequency Under current trip
# of starts Start and stop the solid
High line frequency OL alarm state starter
TruTorque %

Phase reversal Shunt trip fail safe 1 Communication Port:


Power % and non fail safe
Phase loss ModBus / RS485
Peak starting current Ground fault
Instantaneous overcurrent Advanced Functionality:
Last starting duration Energy saver indication
Overcurrent Dual ramp selection
Heating indication
Undercurrent Adjustable kick current
Slow speed forward / reverse
Current imbalance Programmable decel modes
DC braking
Ground fault residual LV BIST test (built-in self test)
Cooling fan
Shorted SCR
1 fixed bypass
Disconnect fault
Inline contactor fault
Control power low
Stack over temperature

Return to the
Table of Contents 4-5
Standard Low Voltage
Starter Products
Intelligent Motor Control
MX 3 / MX 2 Controllers
Control Feature Comparison
MX2 MX3 MX2 MX3 MX2 MX3
Miscellaneous Protection (continued) Metering
Voltage Ramp Zero Seq. Ground Full Voltage and
Fault Protection Current Metering
Current Ramp
Starts Per Hour True RMS Calculation
TruTorque Ramp
RTD Monitoring Factory Menu Calibration
Power Ramp
Motor PTC Current Imbalance Meter
Tach / Speed Control Ramp
Stack OT Switch Ground Fault Meter
Linear Ramp Profiles
Stack Thermistor Input Watt Meters
Squared and S Ramp Profiles
Backspin Timer KVA Meters
Dual Ramps
Time Between Starts VAR Meter
Kicking
Phase Rotation Watt Hour Meters
Voltage Decel
Overvoltage Line Frequency Meter
TruTorque Decel
Undervoltage Power Factor Meter
DC Braking
Phase Loss % OL Meter
Heater / Antiwindmill
UTS / Stall Timer Time Until OL Lockout
Jogging 714% Speed
Release Meter
Zero Speed Switch
Slow Speed Cyclo Operation
Phase Rotation Meter
PF Trip
040% speed
& Power and %
PORT (Power Outage
Inside Delta TruTorque Meter
Ride Through)
Wye-Delta/ Run Time Meter
Keypad Fault Reset
Electromechanical Control
Number of Starts Meter
Adj. Auto Fault Reset Timer
Phase Controller
Peak Current of Last Start Meter
Adj. No. of Auto Resets
Current Follower
Before Lockout Last Starting Time Meter
ATL
Decel After Fault Analog Input Meter
Protection
Fault Log Real Time Clock
Separate Starting / Running
Time and Date Stamp RTD Meters
Overload Classes
9 Data Snapshots of Each Fault Miscellaneous
Adj. Hot / Cold Ratio
Event Log (last 99 events) LV BIST
Adj. Cooling Time
Fault Classes MV BIST
Intelligent Start Lockout
User I/O LV Powered BIST
Adj. OL Lockout Level
Programmable Digital Inputs
Over / Under Current Protection
Programmable Digital Outputs
Retained OL When Power Lost
User Analog Input
Current Imbalance Protection
Programmable User
IOC (Instantaneous Analog Output
Over Current)
Local / Remote Source Input
Open / Shorted SCR Detection
Power Up Start
Overcurrent / Shear Pin
Undercurrent / Load Loss
Residual Ground
Fault Protection

Return to the
4-6 benshaw.com Table of Contents
Open Chassis Solid State Starters
RB Series MX 3 or Product Highlights:
Benshaws RB series solid state starter combines the high performance MX2 or MX3
MX 2 Technology technology with a rugged, compact, integral bypass RB series power section.

With Integral Bypass The MX2 or MX3 technology provides users with a powerful group of programming
parameters, designed for flexibility in across a wide range of industrial applications.
Both MX2 and MX3 controls provide simple setup and commissioning via the Quick
Start Menu.

The RB power section is a rugged, heavy duty solid state starter section designed
with integral bypass contactors for a compact, efficient profile. The modular design
includes separate poles for each phase for ease of maintenance.

Key Advantages:
Small, compact design Integral bypass contactors for
efficient operation, eliminating
Modular power stack assembly
the need for external fans
for ease of maintenance
Integrated motor protection
ModBus standard /
other Fieldbus optional Dual ramp capability for loaded /
unloaded applications
Multiple starting ramps
for various applications Power stack has multiple ratings
for application flexibility
Integrated metering
system diagnostics

NEMA 2-Hole Pattern SCRs in Reverse DV / DT Protection NEMA 2-Hole Pattern


(Bottom Entry / Bottom Exit) Parallel Configuration (Top Entry / Top Exit)

Stack Over-Temperature Integral Bypass


Protection Contactor

RB Power Pole180A

Return to the
Table of Contents 4-7
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB Series MX 3 or MX 2 Technology
Product Selection Guide
Horsepower
Model Number 208 V 240 V 480 V 575 V
Standard Duty 350% for 30 Sec. 115% Continuous
RB2-1-S-027A-11C 7.5 10 20 25
RB2-1-S-040A-11C 10 15 30 40
RB2-1-S-052A-12C 15 20 40 50
RB2-1-S-065A-12C 20 25 50 60
RB2-1-S-077A-13C 25 30 60 75
RB2-1-S-096A-13C 30 40 75 100
RB2-1-S-125A-14C 40 50 100 125
RB2-1-S-156A-14C 50 60 125 150
RB2-1-S-180A-14C 60 75 150 200
RB2-1-S-240A-15C 75 100 200 250
RB2-1-S-302A-15C 100 125 250 300
RB2-1-S-361A-16C 125 150 300 400
RB2-1-S-414A-17C 150 - 350 -
RB2-1-S-477A-17C - 200 400 500
RB2-1-S-515A-17C 200 - 450 -
RB2-1-S-590A-18C - 250 500 600
RB2-1-S-720A-19C 250 300 600 700
RB2-1-S-838A-20C 300 350 700 800
Heavy Duty 500% for 30 Sec. 125% Continuous
RB2-1-S-027A-11C 7.5 10 20 25
RB2-1-S-040A-11C 10 15 30 40
RB2-1-S-052A-12C 15 20 40 50
RB2-1-S-096A-13C 30 40 75 100
RB2-1-S-156A-14C 40 50 100 125
RB2-1-S-180A-15C 60 75 150 200
RB2-1-S-361A-16C 75 100 200 250
RB2-1-S-414A-17C 125 150 300 400
RB2-1-S-590A-18C 200 200 450 500
RB2-1-S-720A-19C - 250 500 600
Severe Duty 600% for 30 Sec. 125% Continuous
RB2-1-S-027A-11C 5 7.5 15 20
RB2-1-S-040A-11C 10 10 30 40
RB2-1-S-052A-11C - 15 - -
RB2-1-S-096A-13C 25 30 60 75
RB2-1-S-180A-14C 30 40 75 100
RB2-1-S-180A-15C 50 60 125 150
RB2-1-S-361A-16C 60 75 150 200
RB2-1-S-414A-17C 100 125 250 300
RB2-1-S-590A-18C 150 200 450 500

Return to the
4-8 benshaw.com Table of Contents
Open Chassis Solid State Starters
RB2 Series with MX 2 Technology
Standard Duty / 200600 Volt

350% for 30 Sec. / 115% Continuous Rated


Horsepower Dimensions (in.)
Weight
Model Number A 208 V 240 V 480 V 575 V H W D (lbs.) List Price
RB2-1-S-027A-11C 27 7.5 10 20 25 14 10 6.9 14 $1,745.00
RB2-1-S-040A-11C 40 10 15 30 40 14 10 6.9 14 $1,825.00
RB2-1-S-052A-12C 52 15 20 40 50 14 10 8.4 17 $1,900.00
RB2-1-S-065A-12C 65 20 25 50 60 14 10 8.4 17 $1,935.00
RB2-1-S-077A-13C 77 25 30 60 75 15 10 8.4 17 $2,045.00
RB2-1-S-096A-13C 96 30 40 75 100 15 10 8.4 18 $2,665.00
RB2-1-S-125A-14C 125 40 50 100 125 21.7 12.3 8.9 43 $2,935.00
RB2-1-S-156A-14C 156 50 60 125 150 21.4 14 9 43 $3,500.00
RB2-1-S-180A-14C 180 60 75 150 200 21.4 14 9 43 $4,265.00
RB2-1-S-240A-15C 240 75 100 200 250 23.8 12.5 10.3 51 $4,550.00
RB2-1-S-302A-15C 302 100 125 250 300 23.8 12.5 10.3 51 $5,000.00
RB2-1-S-361A-16C 361 125 150 300 400 23.9 13.3 9.2 56 $5,855.00
RB2-1-S-414A-17C 414 150 - 350 - 27.9 18 11.1 151 $6,385.00
RB2-1-S-477A-17C 477 - 200 400 500 28.9 18 11.1 155 $7,000.00
RB2-1-S-515A-17C 515 200 - 450 - 28.9 18 11.1 155 $7,500.00
RB2-1-S-590A-18C 590 - 250 500 600 28.8 18 11.1 159 $8,000.00
RB2-1-S-720A-19C 720 250 300 600 700 30.7 18.5 10.9 159 $9,000.00
RB2-1-S-838A-20C 838 300 350 700 800 29.1 26.1 12.5 160 $10,500.00
Web stocked
Available for same day shipping.

Unit requires separate 120 V control power.


Unit includes standard board-mounted LED interface.
The optional LCD interface is shown.
The keypad is shipped loose.

Model Number Description List Price


KPMX3CBL2M NEMA 12 / 3R Remote $425.00
Keypad with 2 Meter Cable

Return to the
Table of Contents 4-9
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB3 Series with MX 3 Technology
Standard Duty / 200600 Volt

350% for 30 Sec. / 115% Continuous Rated


Horsepower Dimensions (in.)
Weight
Model Number A 208 V 240 V 480 V 575 V H W D (lbs.) List Price
RB3-1-S-027A-11C 27 7.5 10 20 25 14 10 7.7 14 $2,595.00
RB3-1-S-040A-11C 40 10 15 30 40 14 10 8.4 14 $2,625.00
RB3-1-S-052A-12C 52 15 20 40 50 14 10 9.2 17 $2,735.00
RB3-1-S-065A-12C 65 20 25 50 60 15 10 9.2 17 $2,750.00
RB3-1-S-077A-13C 77 25 30 60 75 15 10 9.2 17 $3,055.00
RB3-1-S-096A-13C 96 30 40 75 100 15 10 9.2 18 $3,575.00
RB3-1-S-125A-14C 125 40 50 100 125 21.5 12.3 9.7 43 $3,825.00
RB3-1-S-156A-14C 156 50 60 125 150 21.7 14 9.8 43 $4,345.00
RB3-1-S-180A-14C 180 60 75 150 200 21.7 14 9.8 43 $5,000.00
RB3-1-S-240A-15C 240 75 100 200 250 23.8 12.5 11.1 51 $5,250.00
RB3-1-S-302A-15C 302 100 125 250 300 23.8 12.5 11.1 51 $5,725.00
RB3-1-S-361A-16C 361 125 150 300 400 23.9 13.4 10 56 $6,455.00
RB3-1-S-414A-17C 414 150 - 350 - 27.9 18 11.9 151 $6,950.00
RB3-1-S-477A-17C 477 - 200 400 500 28.9 18 11.9 155 $7,500.00
RB3-1-S-515A-17C 515 200 - 450 - 28.9 18 11.9 155 $8,000.00
RB3-1-S-590A-18C 590 - 250 500 600 28.9 18 11.9 159 $8,700.00
RB3-1-S-720A-19C 720 250 300 600 700 30.7 18 11.7 159 $9,500.00
RB3-1-S-838A-20C 838 300 350 700 800 29.1 26.1 13.3 160 $11,000.00
Built-to-order: Please allow 2 weeks for shipment.

Unit requires separate 120 V control power.


Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.

Return to the
4-10 benshaw.com Table of Contents
Open Chassis Solid State Starters
RB2 Series with MX 2 Technology
Heavy Duty / 200600 Volt

500% for 30 Sec. / 125% Continuous Rated


Horsepower
Weight
Model Number A 208 V 240 V 480 V 575 V (lbs.) List Price
RB2-1-S-027A-11C 24 7.5 10 20 25 14 $1,745.00
RB2-1-S-040A-11C 40 10 15 30 40 14 $1,825.00
RB2-1-S-052A-12C 52 15 20 40 50 17 $1,900.00
RB2-1-S-096A-13C 96 30 40 75 100 18 $2,665.00
RB2-1-S-156A-14C 125 40 50 100 125 43 $4,635.00
RB2-1-S-180A-15C 204 60 75 150 200 43 $5,975.00
RB2-1-S-361A-16C 252 75 100 200 250 56 $6,500.00
RB2-1-S-414A-17C 372 125 150 300 400 151 $8,525.00
RB2-1-S-590A-18C 551 200 200 450 500 159 $9,795.00
RB2-1-S-720A-19C 623 - 250 500 600 160 $9,795.00
Web stocked
Available for same day shipping.

Unit requires separate 120 V control power.


Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.

Return to the
Table of Contents 4-11
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RB3 Series with MX 3 Technology
Heavy Duty / 200600 Volt

500% for 30 Sec. / 125% Continuous Rated


Horsepower Dimensions (in.)
Weight
Model Number A 208 V 240 V 480 V 575 V H W D (lbs.) List Price
RB3-1-S-027A-11C 24 7.5 10 20 25 14 10 7.7 14 $2,595.00
RB3-1-S-040A-11C 40 10 15 30 40 14 10 8.4 14 $2,625.00
RB3-1-S-052A-12C 52 15 20 40 50 14 10 9.2 17 $2,735.00
RB3-1-S-096A-13C 96 30 40 75 100 15 10 9.2 18 $3,575.00
RB3-1-S-125A-14C 125 40 50 100 125 21.5 12.3 9.7 43 $5,365.00
RB3-1-S-180A-15C 204 60 75 150 200 21.5 14.3 9.8 43 $6,585.00
RB3-1-S-361A-16C 252 75 100 200 250 23.9 13.4 10 56 $7,075.00
RB3-1-S-414A-17C 372 125 150 300 400 27.9 18 11.9 151 $8,900.00
RB3-1-S-590A-18C 551 200 200 450 500 28.9 18 11.9 159 $10,055.00
RB3-1-S-720A-19C 623 - 250 500 600 30.7 18 11.7 160 $10,055.00
Please allow 2 week lead time.

Unit requires separate 120 V control power.


Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.

Return to the
4-12 benshaw.com Table of Contents
Open Chassis Solid State Starters
RC Series With MX 3 Product Highlights:
The RC Series Solid State Starter combines the high performance MX2 or MX3 control
or MX 2 Technology with the rugged, continuous duty, fan cooled RC stack.

Non-Bypassed / The MX2 or MX3 series control provides users with a powerful group of programming
parameters, designed for flexibility in industrial applications. The MX2 and MX3 both
Continuous Duty, provide simple setup and commissioning via the Quick Start Menu.

11586 Amp / 600 VAC The RC power section is a rugged non-bypassed section. It is an economical solution at low
horsepower. In addition, the fan cooled stack provides high duty cycle and high inertia starting
and energy saver operation.

Key Advantages:
Economical at low horsepower Modbus standard / Profibus, Ethernet,
DeviceNet, Ethernet IP web addressable
High duty cycle starting
communication protocols are available
Long starting times via optional communication bridges
Suitable for jogging applications 1.25 service factor
Fan cooled stack Integrated metering and diagnostics
Integrated motor protection Multiple starting ramps
for various applications

Return to the
Table of Contents 4-13
Standard Low Voltage
Starter Products
Open Chassis Solid State Starters
RC2 Series with MX 2 Technology
Non-Bypassed /Continuous Duty, 11586 Amp / 600 VAC

500% Current for 30 Sec. / 125% Continuous Rated


Horsepower Dimensions (in.)
Weight
Model Number A 208 V 240 V 480 V 575 V H W D (lbs.) List Price
RC2-0-S-027A-31C 27 7.5 10 20 25 14 9.9 7.9 15 $1,700.00
RC2-0-S-040A-31C 40 10 15 30 40 14 9.9 7.9 15 $1,835.00
RC2-0-S-052A-31C 52 15 20 40 50 14 9.9 7.9 18 $1,965.00
RC2-0-S-065A-32C 65 20 25 50 60 18 10 9.6 18 $2,085.00
RC2-0-S-077A-32C 77 25 30 60 75 18 10 9.6 18 $2,125.00
RC2-0-S-096A-33C 96 30 - 75 100 27 10 9.6 19 $2,165.00
RC2-0-S-125A-33C 125 40 50 100 125 27 10 9.6 45 $3,225.00
RC2-0-S-156A-34C 156 50 60 125 150 24 22 10.1 45 $3,335.00
RC2-0-S-180A-34C 180 60 75 150 200 24 22 10.1 45 $3,335.00
RC2-0-S-240A-35C 240 75 100 200 250 26 22 10.1 55 $3,950.00
RC2-0-S-302A-35C 302 100 125 250 300 26 22 10.1 55 $4,315.00
RC2-0-S-361A-35C 361 125 150 300 400 26 22 10.1 60 $4,545.00
RC2-0-S-414A-35C 414 150 - 350 - 26 22 10.1 150 $5,395.00
RC2-0-S-477A-35C 477 - 200 400 500 26 22 10.1 150 $6,215.00
RC2-0-S-515A-36C 515 200 - 450 - 36.8 29 10.7 150 $7,025.00
RC2-0-S-590A-36C 590 - 250 500 600 36.8 29 10.7 160 $7,900.00
Built-to-order: Please allow 2 weeks for shipment.

Unit requires separate 120 V control power.


Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.

Return to the
4-14 benshaw.com Table of Contents
Open Chassis Solid State Starters
RC3 Series with MX 3 Technology
Non-Bypassed /Continuous Duty, 11586 AMP / 600 VAC

500% Current for 30 Sec. / 125% Continuous Rated


Horsepower Dimensions (in.)
Weight
Model Number A 208 V 240 V 480 V 575 V H W D (lbs.) List Price
RC3-0-S-027A-31C 27 7.5 10 20 25 14 9.9 8.7 15 $2,045.00
RC3-0-S-040A-31C 40 10 15 30 40 14 9.9 8.7 15 $2,175.00
RC3-0-S-052A-31C 52 15 20 40 50 14 9.9 8.7 18 $2,645.00
RC3-0-S-065A-32C 65 20 25 50 60 18 10 10.4 18 $2,735.00
RC3-0-S-077A-32C 77 25 30 60 75 18 10 10.4 18 $2,850.00
RC3-0-S-096A-33C 96 30 - 75 100 27 10 10.4 19 $3,325.00
RC3-0-S-125A-33C 125 40 50 100 125 27 10 10.4 45 $4,385.00
RC3-0-S-156A-34C 156 50 60 125 150 24 22 10.9 45 $4,495.00
RC3-0-S-180A-34C 180 60 75 150 200 24 22 10.9 45 $4,600.00
RC3-0-S-240A-35C 240 75 100 200 250 26 22 10.9 55 $5,100.00
RC3-0-S-302A-35C 302 100 125 250 300 26 22 10.9 55 $5,475.00
RC3-0-S-361A-35C 361 125 150 300 400 26 22 10.9 60 $5,695.00
RC3-0-S-414A-35C 414 150 - 350 - 26 22 10.9 150 $6,555.00
RC3-0-S-477A-35C 477 - 200 400 500 26 22 10.9 150 $7,375.00
RC3-0-S-515A-36C 515 200 - 450 - 36.8 29 11.5 150 $8,195.00
RC3-0-S-590A-36C 590 - 250 500 600 36.8 29 11.5 160 $9,065.00
Built-to-order: Please allow 2 weeks for shipment.

Unit requires separate 120 V control power.


Unit includes remote mountable LCD keypad (KPMX3CBL2M) with 2 meter cable.
Please order part number, KPMX3CBL2M, with chassis, see page 4-9.
The keypad is shipped loose.

Return to the
Table of Contents 4-15
Standard Low Voltage
Starter Products
Prepackaged Starters with ATL Bypass
RX Series with MX 3 Product Highlights:
RX2E starters provide solid state reduced voltage starting for normal operation and
or MX 2 Technology full voltage emergency backup starting with complete electronic motor protection
at the flip of a switch. This unique redundant design is the ideal solution for critical
applications where downtime is extremely disruptive to production operations and
cannot be tolerated. Benshaws MX solid state controls provide precise digital starting
Severe Duty 480 V / NEMA and stopping, motor protection, metering, diagnostics and communications.
12 or 3R / Combination / Units are stocked with MX2 technology, but are available with MX3 technology.
Dual Redundant Starting Standard Features:
NEMA 12, redundant, combination / circuit breaker
Shunt trip on main circuit breaker
500%30 seconds rated solid state starter, UL certified and listed
1800 PIV rated SCRs, UL certified and listed
125% continuous duty rated solid state starter, UL certified and listed
Selector switch for selecting solid state or full voltage operation mounted
inside enclosure
Full HP rated bypass contactor with a 1.15 service factor, wired for normal
bypass operation and full voltage start and run operation, with normally
open auxiliary contact
Separately mounted "SPE" series overload relay wired for full voltage start
and run operation
110 volt control power transformer with primary and secondary fuses
Door mounted start and stop push-buttons
Door mounted keypad
Door mounted run indicating light
Door mounted local-off remote switch
Door mounted overload reset
Benshaw soft start and emergency bypass control board with customer connections
Auxiliary relay with (2) Form C run contacts
Benshaw MX2 programmable motor controller with soft start, soft stop and motor
protection capabilities
RS485 ModBus communications
Analog I/O
Available with MX3 technology

Return to the
4-16 benshaw.com Table of Contents
Prepackaged Starters with ATL Bypass
RX2E Series with MX2 Technology
Model Number HP CB Dimensions (in.)
Weight
NEMA 12 List Price NEMA 3R List Price A 480 V Trip H W D (lbs.)
RX2E-050-480-12KP $5,300.00 RX2E-050-480-3RKP $5,800.00 65 50 125 26 24 12 215
RX2E-075-480-12KP $6,500.00 RX2E-075-480-3RKP $6,835.00 96 75 175 26 24 12 220
RX2E-100-480-12KP $7,250.00 RX2E-100-480-3RKP $7,955.00 124 100 225 48 24 12 230
RX2E-125-480-12KP $7,300.00 RX2E-125-480-3RKP $8,625.00 156 125 250 48 24 12 320
RX2E-150-480-12KP $7,450.00 RX2E-150-480-3RKP $8,755.00 180 150 300 48 24 12 325
RX2E-200-480-12KP $9,565.00 RX2E-200-480-3RKP $10,750.00 240 200 400 48 36 16 335
RX2E-250-480-12KP $10,525.00 RX2E-250-480-3RKP $11,750.00 302 250 500 70 30 18 510
RX2E-300-480-12KP $10,875.00 RX2E-300-480-3RKP $12,000.00 361 300 600 70 30 18 515
RX2E-400-480-12KP $14,000.00 RX2E-400-480-3RKP $16,750.00 477 400 800 87 37 20 765
RX2E-500-480-12KP $19,000.00 RX2E-500-480-3RKP $20,000.00 590 500 1200 87 37 20 790
RX2E-600-480-12KP $20,000.00 RX2E-600-480-3RKP $22,000.00 720 600 1200 87 37 20 815

RX3E Series with MX3 Technology


Model Number HP CB Dimensions (in.)
Weight
NEMA 12 List Price NEMA 3R List Price A 480 V Trip H W D (lbs.)
RX3E-050-480-12KP $6,395.00 RX3E-050-480-3RKP $6,755.00 65 50 125 26 24 12 215
RX3E-075-480-12KP $6,750.00 RX3E-075-480-3RKP $7,335.00 96 75 175 26 24 12 220
RX3E-100-480-12KP $7,885.00 RX3E-100-480-3RKP $8,365.00 124 100 225 48 24 12 230
RX3E-125-480-12KP $8,550.00 RX3E-125-480-3RKP $8,955.00 156 125 250 48 24 12 320
RX3E-150-480-12KP $8,675.00 RX3E-150-480-3RKP $9,085.00 180 150 300 48 24 12 325
RX3E-200-480-12KP $10,775.00 RX3E-200-480-3RKP $11,000.00 240 200 400 48 36 16 335
RX3E-250-480-12KP $11,725.00 RX3E-250-480-3RKP $12,000.00 302 250 500 70 30 18 510
RX3E-300-480-12KP $12,000.00 RX3E-300-480-3RKP $12,250.00 361 300 600 70 30 18 515
RX3E-400-480-12KP $16,500.00 RX3E-400-480-3RKP $17,000.00 477 400 800 87 37 20 765
RX3E-500-480-12KP $23,000.00 RX3E-500-480-3RKP $24,000.00 590 500 1000 87 37 20 790
RX3E-600-480-12KP $24,000.00 RX3E-600-480-3RKP $25,000.00 720 600 1200 87 37 20 815
50600 HP units are service entrance rated.
Built-to-order: Please allow one week for shipment.
Web stocked
Available for same day shipping.

Return to the
Table of Contents 4-17
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PC / MX2PB Configure the MX2PB / MX2PC to fit your application
To choose a stock starter, simply select a unit from the following pages. We will ship
Series with MX 2 stock units ship the same day.

Technology To modify a starter, select a unit from the following pages, then add an alpha board
and / or other options as needed from the Options section (see page 4-23). We will
Non-Bypass / Continuous modify the stock unit for next day shipment.

Duty or Integral Bypass MX2PB / MX2PC configurable solid state starters stocked as:
Non-combination
Combination circuit breaker
Rotary disconnect operator
Non-bypass
Bypass contactor
NEMA 4 or 12 enclosure
Modular operator station
480 V
Standard 120 V control power transformer
Service entrance rated with circuit breaker
Door mounted key pad

Model shown is completely configured with all options.

(Stock
Unit
Shown)

1. Select a starter type: 2. Select a horsepower rating 5. Select a circuit breaker (or none)

MX2PC modular non-bypass 3. Select a voltage 6. Select your options


MX2PB modular bypassed 4. Select an enclosure

Return to the
4-18 benshaw.com Table of Contents
Prepackaged Starters
MX2PB / MX2PC Series with MX 2 Technology
Part Number Assembler

MX2PB SD 150 4 4 CB ST

Starter Series Enclosure Options


MX2PC = Modular 4 = NEMA 4/12 ST = Standard
Non-Bypassed
OP = Options Included
MX2PB = Modular Bypassed

Duty Type Standard Duty HP Rating Voltage Disconnect


SD = Standard Duty 20 = 20 HP 4 = 480 V NC = None
HD = Heavy Duty 30 = 30 HP 2 = 240 V CB = Circuit Breaker
40 = 40 HP
50 = 50 HP
75 = 75 HP
100 = 100 HP
150 = 150 HP
200 = 200 HP
300 = 300 HP
400 = 400 HP

All units include 120 V control power transformer.

Return to the
Table of Contents 4-19
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PB Series with MX 2 Technology
Integral Bypass Non-Combination

240 V
Dimensions (in.)
Std. Duty1 Heavy Weight
Model Number HP Duty2 HP V H W D (lbs.) List Price
MX2PB-015-2-4-NC ** 15 15 240 24 16 15 110/3 $4,050.00
MX2PB-020-2-4-NC ** 20/25 20 240 24 16 15 110 $4,100.00
MX2PB-030-2-4-NC ** 30/40 30/40 240 36 16 15 150 $4,625.00
MX2PB-050-2-4-NC ** 50 50 240 36 20 15 150 $4,850.00
MX2PB-075-2-4-NC ** 60/75 60/75 240 48 20 15 180 $5,050.00
MX2PB-100-2-4-NC ** 100 240 48 20 15 180 $5,225.00
MX2PB-150-2-4-NC ** 150 100 240 48 20 15 180 $6,045.00
MX2PB-200-2-4-NC ** 200 150 240 78 30 20 350 $8,300.00
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Built-to-order

480 V
Dimensions (in.)
Std. Duty1 Heavy Weight
Model Number HP Duty2 HP V H W D (lbs.) List Price
MX2PB-030-4-4-NC **2 30 30 480 24 16 15 110 $4,050.00
MX2PB-050-4-4-NC **2 50 40 480 24 16 15 110 $4,100.00
MX2PB-075-4-4-NC **2 75 75 480 36 16 15 150 $4,625.00
MX2PB-100-4-4-NC **2 100 480 36 20 15 150 $4,850.00
MX2PB-150-4-4-NC **2 150 150 480 48 20 15 180 $5,050.00
MX2PB-200-4-4-NC **2 200 480 48 20 15 180 $5,225.00
MX2PB-300-4-4-NC **2 300 200 480 48 20 15 180 $6,045.00
MX2PB-400-4-4-NC **2 400 300 480 78 30 20 350 $8,300.00
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Available for same day shipment, or modified for next day shipment.

Web stocked

Return to the
4-20 benshaw.com Table of Contents
Prepackaged Starters
MX2PB Series with MX 2 Technology
Integral Bypass Combination Circuit Breaker

240 V
Dimensions (in.)
Std. Duty1 Heavy Weight
Model Number HP Duty2 HP V H W D (lbs.) List Price
MX2PB-020-2-4-CB ** 20/25 20 240 36 16 15 175 $5,150.00
MX2PB-030-2-4-CB ** 30/40 30/40 240 42 20 15 200 $5,325.00
MX2PB-050-2-4-CB ** 50 240 48 24 15 220 $5,695.00
MX2PB-075-2-4-CB ** 60/75 60/75 240 48 24 15 220 $6,325.00
MX2PB-100-2-4-CB ** 100 240 48 24 15 220 $6,675.00
MX2PB-150-2-4-CB ** 150 100 240 48 24 15 220 $8,375.00
MX2PB-200-2-4-CB ** 200 150 240 78 30 24 400 $10,450.00
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Built-to-order: Please allow 2 week lead time.

480 V
Dimensions (in.)
Std. Duty1 Heavy Weight
Model Number HP Duty2 HP V H W D (lbs.) List Price
MX2PB-050-4-4-CB **2 50 40 480 36 16 15 175 $5,150.00
MX2PB-075-4-4-CB **2 75 75 480 42 20 15 200 $5,325.00
MX2PB-100-4-4-CB **2 100 480 48 24 15 220 $5,695.00
MX2PB-150-4-4-CB **2 150 150 480 48 30 15 220 $6,325.00
MX2PB-200-4-4-CB **2 200 480 48 30 15 220 $6,675.00
MX2PB-300-4-4-CB **2 300 200 480 48 30 15 220 $8,375.00
MX2PB-400-4-4-CB **2 400 300 480 78 30 24 400 $10,450.00
** Insert option code. See page 4-22 for a list of available options. ST = No options / OP = Options included
1 Standard duty = 350% current for 30 seconds, 1.15 S.F.
2 Heavy duty = 500% current for 30 seconds, 1.25 S.F.
Available for same day shipment, or modified for next day shipment.

Web stocked

Model Number Description List Price


KPMX3CBL2M NEMA 12 / 3R Remote Keypad $425.00
with 2 Meter Cable

Return to the
Table of Contents 4-21
Standard Low Voltage
Starter Products
Prepackaged Starters
MX2PB / MX2PC Series With MX 2 Technology
Options

Option Code Space Heater Option List Price


U4 Space Heater with Thermostat $445.00

Option Code Control Options (only one code can be selected) List Price
QN Run Light $125.00
QF Reset Push-Button $85.00
CP Start / Stop Push-Buttons $175.00
CQ Start / Stop Push-Buttons and Run Light $235.00
CR Start / Stop Push-Buttons, Run Light, Fault Light $500.00
and Reset Push-Button
RK Fault Light $125.00
CS Fault Light and Reset Push-Button $210.00
CT Run Light, Fault Light and Reset Push-Button $335.00
CU HOA and Start / Stop Push-Buttons $325.00
CV HOA, Start / Stop Push-Buttons and Run Light $445.00
CW HOA, Start / Stop Push-Buttons, Run Light, Fault Light and Reset Push-Button $655.00

Option Code Communications Options List Price


CD Profibus
CE DeviceNet
CF Ethernet
CG Lon Works
CH IP Internet Web Addressable
CC RS232 ConnectorAllows User to Connect Remotely without Opening the Encl. Door
Consult factory

Return to the
4-22 benshaw.com Table of Contents
Engineered Low Voltage
Starter Packages
Overview
Benshaw has developed advanced engineering, drafting, materials management and quality systems focused on designing and building customer
solutions. This "Engineered-to-Order" capability, combined with an extensive inventory of control components, protective relays, circuit breakers,
contactors, enclosures and other electrical / electronic devices, enables Benshaw to quickly ship engineered products.

Control ModificationsWhatever You Specify:


Over 250 modifications and accessories are available, including: pilot devices,
PLCs, control power transformers, switches, meters, relays, space heaters,
and protective devices.

Combination StartersTo Meet Your Requirements:


15 to 2000 amp circuit breakers
40 to 2000 amp non-fused disconnects
30 to 800 amp fusible disconnect
Flange or rotary handle mechanism
Power StacksTo Fit Your Application:
Continuous duty / non-bypassed
Integral bypass
Standard, heavy and severe duty
Emergency across-the-line bypass
EnclosuresTo Match Your Environment:
Standard designsNEMA 1, 12, 4 chassis
Custom enclosures
Special enclosures3R, 4X, 7, 9, as specified
Motor control centers
Communication
ModBus / RS485

Benshaw quickly ships engineered products.


Return to the
Table of Contents 4-23
Engineered Low Voltage
Starter Products
Wound Rotor Starters
RATINGS Product Highlights:
Wound rotor motors are typically used in applications requiring high starting torques,
Horsepower: a limited number of operating speeds, or a stepped acceleration to achieve a soft
start. Typical existing applications utilize an electromechanical starter on the stator
201500 HP and introduce multiple stages of resistance in the rotor via contactor arrangements
to achieve a soft ramp.
Overload: With the RediStart MX3, wound rotor control is greatly simplified. The RediStart
500% for 30 seconds consists of two major sections: 1) A solid-state stator control, and 2) secondary
125% continuous resistors into the rotor circuit from a separate 3-phase resistor bank. This achieves
the high torque required by the applicationwith low inrushwhile providing a
smooth stepless start. This greatly reduces the maintenance cost of the typical
Starting Torque: electromechanical control.
0100% Single Step Rotor Control: The solid-state starter is wired to the motor stator circuit,
and the resistor and shorting contactor are wired to the motor rotor circuit. The solid
Voltage: state starter accelerates the motor to slip speed (determined by the resistance value)
and then activates the contactor to short the rotor. This allows the motor to accelerate
2001000 VAC to full speed.

Multiple Step Rotor Circuit: WR RVSS series starters can be supplied with multiple
Typical Resistance Steps:
stages of rotor resistor and contactor combinations. This arrangement may be
1-2 necessary for multiple step starting of extremely high inertia loads, or for continuous
operation at multiple speeds. Multiple steps of rotor resistance can be coordinated
to achieve this.

Variable Speed Control: Variable speed control of wound rotor motors can be
accomplished with the RediStart series control. By maintaining full output voltage of
the control going to the stator of the wound rotor motor, and varying the resistance
in the rotor, variable speed is accomplished.

Resistors must be rated for continuous duty operations. Variable loads (pumps and
fans) only.

Key Advantages:
Benshaw MX3 technology Modbus capable
Single step rotor control Configurable output relays
Modular power stack design Multistep and variable speed
for ease of maintenance rotor control available
Integral bypass contactor design Reduced maintenance
Advanced MX motor protection
3
Reduced in size and number
of resistors needed
Advanced MX3 metering function
Stepless control
Real time clock
Reduces inrush while
99 event log history
maintaining torque

Return to the
4-24 benshaw.com Table of Contents
Wound Rotor Motor Starter Check List
Present starting
Across the line Other ___________________________________
method
Rotor circuit Present number of steps of Total starting ohm value
information resistance ____________ ____________ ohms
Current
method of
Step one ____________ sec. Step two _________ sec. Step three______ sec. Step four _____ sec. Step five ____ sec.
resistance
shorting
The present number of steps may be more or less than listed above. Please specify.
Motor Primary Secondary
information voltage______________ voltage_______________
Primary Secondary
amps________________ amps_________________
Service
RPM ________________
Factor________________
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________

Return to the
Table of Contents 4-25
Engineered Low Voltage
Starter Products
Synchronous Starters
SEP Series Product Highlights:
The sync motor functions as an induction motor during start up. Once the motor
approaches full synchronous speed, the Redistart DC exciter induces a constant
RATINGS polarity to the rotor causing the motor to lock into sync. Because the rotors field
is constant and separately excited, there is no slip required to produce torque,
Horsepower: as with an induction motor. This allows the motor to run at synchronous speed.

201500 HP The Benshaw synchronous package consists of a solid state starter portion connected
to the stator and an SEP (synchronous excitation package) that is connected to the
rotor section in conjunction with a discharge resistor. This SEP is supplied for brush
Overload: type and brushless exciters.

500% for 30 seconds Synchronous Benefits:


125% continuous The RediStart series solid state starter provides reduced voltage stepless acceleration
and automatic synchronization of three phase AC synchronous motors. Synchronous
motors are utilized for a number of reasons. They are used in applications that require
Starting Torque:
precise motor speed, they are used to obtain greater efficiencies and they are used
0100% for facility power factor correction.

Since synchronous motors can be operated at leading power factor, they are used
Voltage: to correct a facilitys lagging power factor created by all the other induction motors
being operated.
2001000 VAC
This correction reduces the penalty a customer pays the utility company for creating
Includes discharge resistor
poor power factor.
and synchronous excitation
package for brush type and Key Advantages:
brushless motor. Benshaw synchronous technology Modbus communication
Solid state synchronous rotor control Configurable output relays
Exciter Ratings: Modular power stack design Reduced maintenance
for ease of maintenance
125250 VDC Reduction in size compared
30120 A* Integral bypass contactor design to existing field control
Advanced synchronous Stepless control
* Consult factory for higher Amp rating. motor protection
Reduces inrush while
Can be added to maintaining torque
existing equipment
Brush type and brushless control
Can be supplied with MX2
or MX3 starter control

Return to the
4-26 benshaw.com Table of Contents
Synchronous Motor Starter Check List

Present starting
Across the line Other please specify ______________________ Application _______________________
method
Field discharge resistor value____________ohms
Motor
Motor horsepower__________ Motor frequency ________Hz
information
Field voltage_______________ Max field current __________
Full load current____________ Motor LRA________________ Motor voltage________
RPM______________________ Service Factor_____________
Motor Wk2 ________________ Load Wk2_________________ Motor Speed ____RPM
Size of utility supply transformer_____________________kVA
Present time to accelerate to full speed approximate______________sec.
Starts required per hour_________________
Brushless exciter or Brush Type exciter
Options : Circuit Breaker Fusible Switch No disconnect needed
Bypass contactor run duty only
120 VAC control power by Benshaw
Start Stop Pushbutton
Hand Off Auto Local Off Remote 2-Wire Control 3-Wire Control

Return to the
Table of Contents 4-27
Engineered Low Voltage
Starter Products
Solid State Starters with Reversing Control
RB2 / RB3 Series Product Highlights:
Benshaw also offers a microprocessor controlled solid state reduced voltage reversing
starter for three phase induction motors. This starter provides a closed loop current
RATINGS ramp for smooth stepless motor acceleration. The RediStart reversing starter is offered
with a reversing contactor set.
Horsepower:
Key Advantages:
201500 HP Benshaw MX2 or MX3 technology with reversing contactor control
Available with DC injection brake
Overload:
Modular power stack design for ease of maintenance
500% for 30 seconds Integral bypass contactor design
125% continuous Advanced MX2 or MX3 motor protection
Advanced MX2 or MX3 metering function
Starting Torque:
Real time clock (MX3 only)
0100% 99 event log history (MX3 only)
ModBus communication
Voltage:
Configurable output relays
2001000 VAC Reduced maintenance

Return to the
4-28 benshaw.com Table of Contents
Solid State Starters with Two Speed Control
MX 2 / MX 3 Series Product Highlights:
These RediStart solid state starters provide reduced voltage stepless control of two
speed three phase AC induction motors.
RATINGS
The two speed starter can be used with two speed, two winding motors. It contains
a ten SCR power section or it can be used with two speed, single winding motors.
Horsepower:
The logic control incorporates MX2 or MX3 technology with all the circuitry required
201500 HP to drive the power semiconductors located in the power section.

Benshaw RediStart two speed starters are electronically interlocked so that a start
Overload:
cannot be initiated at one speed if the starter is already running in another.
500% for 30 seconds
Key Advantages:
125% continuous
Benshaw MX2 or MX3 series control
Starting Torque: Two speed one winding or two speed two winding available
Modular power stack design for ease of maintenance
0100%
Reversing available
Voltage: Integral bypass contactor design
Advanced MX2 or MX3 motor protection
2001000 VAC
Advanced MX2 or MX3 metering function
Two Speed Two Winding
Two Speed One Winding Real time clock (MX3 only)
99 event log history (MX3 only)
ModBus communication
Configurable output relays
Reduced maintenance

Return to the
Table of Contents 4-29
Engineered Low Voltage
Starter Products
Solid State Starters
Engineered Packages
Part Number Assembler

R B 2 1 S 100 480 S 04 NC ST

Starter Series Interrupt Rating Voltage Disconnect Option


R = RediStart S = Standard 208 = 208 V NC = Non-
Combination
H = High 240 = 240 V
CB = Circuit Breaker
480 = 480 V
Configuration Type of Bypass FD = Fusible
575 = 575 V
= None Disconnect
B = Bypass 0
Contactor = Integral
1
C = Continuous
2 = Separate,
Definite Options
Purpose ST = Standard
Control 3 = Separate ATL Horsepower Power Stack Rating OP = Options
IEC Rated Included
2 = MX 2
1 = 1 HP S = 350% 30
Technology 4 = Separate ATL Seconds
NEMA Rated 2 = 2 HP
3 = MX3 H = 500% 30
Technology
3 = 3 HP
Seconds Enclosure
DC Injection 5 = 5 HP OC = Open
V = 600% 30
Braking Chassis
7 = 7.5 HP Seconds
1 = NEMA 1
10 = 10 HP
12 = NEMA 12
15 = 15 HP
4 = NEMA 4
20 = 20 HP
3R = NEMA 3R
25 = 25 HP
30 = 30 HP
40 = 40 HP
50 = 50 HP
60 = 60 HP
75 = 75 HP
100 = 100 HP
125 = 125 HP
150 = 150 HP
200 = 200 HP
250 = 250 HP
300 = 300 HP
400 = 400 HP
500 = 500 HP
600 = 600 HP
700 = 700 HP
800 = 800 HP
900 = 900 HP
1000 = 1000 HP

Return to the
4-30 benshaw.com Table of Contents
Wye Delta Starters

Smart Wye-Delta Starter Kits..............5-2

Return to the
Table of Contents 5-1
Wye Delta Starters
Smart Wye-Delta Starter Kits
Wye Delta Starters Product Highlights:
Benshaws MX2 control technology provides an innovative way to bring powerful,
flexible, intelligent low voltage motor control to traditional non-intelligent wye
delta electro-mechanical starters. MX2-based controls offer multiple, user
selectable modes, an increased selection of configurable analog and digital
I/Os, comprehensive metering capabilities, unprecedented on-board protections
and an easy to use interface.

Benshaws MX2 technology makes for an excellent alternative to traditional electro-


mechanical wye delta starters. The transition from wye to delta is controlled by the
solid state circuitry to ensure ease in setting up the wye delta starter parameters to
match your application.

With more built-in starting modes, more built-in metering, protection features and
additional communication capabilities, Benshaws MX2-based low voltage wye delta
starters raise the bar for intelligent, low cost wye delta controls.

Control Features: (Partial)

Motor Protection Metering

Motor thermal overloads Average current


Up to speed time exceeded L1 current
Low line voltage L2 current
Low line frequency L3 current
High line frequency Current imbalance %
Phase reversal Ground fault amps / residual
Phase loss Average or phase volts
Instantaneous Overcurrent power factor
Over current Watts
Under current VA
Current imbalance kW hours

Benshaws SMART wye delta starters are available in both non-combination and
combination packages and NEMA 1, 12, 3R and 4 enclosures. All UL listed and NEMA
compliant. Many options and accessories can be added; please consult factory with
your specific needs.

Return to the
5-2 benshaw.com Table of Contents
Smart Wye-Delta Starter Kits
Smart Wye Delta
Starter Max Amps Model Number Description Enclosure Size (in.)
1559 FS-SMYD-MX-00-XX Smart Wye-Delta Starter Kit, 1559A, 200575V 86x72x24
1143 FS-SMYD-MX-01-XX Smart Wye-Delta Starter Kit, 1143A, 200575V 86x72x24
779 FS-SMYD-MX-02-XX Smart Wye-Delta Starter Kit, 779A, 200575V 79x40x20
606 FS-SMYD-MX-03-XX Smart Wye-Delta Starter Kit, 606A, 200575V 79x40x20
476 FS-SMYD-MX-04-XX Smart Wye-Delta Starter Kit, 476A, 200575V 70x30x18
398 FS-SMYD-MX-05-XX Smart Wye-Delta Starter Kit, 398A, 200575V 70x30x18
364 FS-SMYD-MX-06-XX Smart Wye-Delta Starter Kit, 364A, 200575V 48x36x16
277 FS-SMYD-MX-07-XX Smart Wye-Delta Starter Kit, 277A, 200575V 48x36x16
217 FS-SMYD-MX-08-XX Smart Wye-Delta Starter Kit, 217A, 200575V 48x36x16
156 FS-SMYD-MX-09-XX Smart Wye-Delta Starter Kit, 156A, 200575V 48x24x12
139 FS-SMYD-MX-10-XX Smart Wye-Delta Starter Kit, 139A, 200575V 48x24x12
130 FS-SMYD-MX-11-XX Smart Wye-Delta Starter Kit, 130A, 200575V 48x24x12
104 FS-SMYD-MX-12-XX Smart Wye-Delta Starter Kit, 104A, 200575V 48x24x12
78 FS-SMYD-MX-13-XX Smart Wye-Delta Starter Kit, 78A, 200575V 48x24x12
69 FS-SMYD-MX-14-XX Smart Wye-Delta Starter Kit, 69A, 200575V 48x24x12
XX denotes enclosure type e.g. 1, 12, 3R or 4.

Smart Wye Delta Combination Circuit Breaker


Starter Max Amps Model Number Description Enclosure Size (in.)
1559 FS-SMYD-MX-00-XX Smart Wye-Delta Starter Kit, 1559A, 200575V 86x72x24
1143 FS-SMYD-MX-01-XX Smart Wye-Delta Starter Kit, 1143A, 200575V 86x72x24
779 FS-SMYD-MX-02-XX Smart Wye-Delta Starter Kit, 779A, 200575V 79x40x20
606 FS-SMYD-MX-03-XX Smart Wye-Delta Starter Kit, 606A, 200575V 79x40x20
476 FS-SMYD-MX-04-XX Smart Wye-Delta Starter Kit, 476A, 200575V 70x30x18
398 FS-SMYD-MX-05-XX Smart Wye-Delta Starter Kit, 398A, 200575V 70x30x18
364 FS-SMYD-MX-06-XX Smart Wye-Delta Starter Kit, 364A, 200575V 48x36x16
277 FS-SMYD-MX-07-XX Smart Wye-Delta Starter Kit, 277A, 200575V 48x36x16
217 FS-SMYD-MX-08-XX Smart Wye-Delta Starter Kit, 217A, 200575V 48x36x16
156 FS-SMYD-MX-09-XX Smart Wye-Delta Starter Kit, 156A, 200575V 48x24x12
139 FS-SMYD-MX-10-XX Smart Wye-Delta Starter Kit, 139A, 200575V 48x24x12
130 FS-SMYD-MX-11-XX Smart Wye-Delta Starter Kit, 130A, 200575V 48x24x12
104 FS-SMYD-MX-12-XX Smart Wye-Delta Starter Kit, 104A, 200575V 48x24x12
78 FS-SMYD-MX-13-XX Smart Wye-Delta Starter Kit, 78A, 200575V 48x24x12
69 FS-SMYD-MX-14-XX Smart Wye-Delta Starter Kit, 69A, 200575V 48x24x12
XX denotes enclosure type e.g. 1, 12, 3R or 4.

Return to the
Table of Contents 5-3
Wye Delta Starters
Smart Wye-Delta Starter Kits
Basic Wiring Diagram

Return to the
5-4 benshaw.com Table of Contents
Pump Control Starters

Prepackaged Full Voltage Starters


with Door Mounted Controls..............6-2

Engineered / Configurable
Pump Panels.......................................6-4

Return to the
Table of Contents 6-1
Pump Control Starters
Prepackaged Full Voltage Starters
With Door Mounted Controls
RCI Series Product Highlights:
RCI starters are NEMA Rated, cUL listed, completely integrated, full voltage/non-
Non-Combination / reversing starter packages. The rugged NEMA 12/3R design is ideal for Industrial Duty
Applications such as pumps, compressors, conveyors, fans and any other continuous
Combination / NEMA duty equipment. The three wires in/out design includes the Benshaw SPE, field
12/3R / Electronic adjustable electronic overload relay, which enables quick installation and startup with
precision motor protection...standard.
Overload Protection
Rugged. Reliable. Ready.
Key Advantages:
Control Terminal Block cUL listed
NEMA rated, heavy duty contactors
Fused Control Power
NEMA 12/3R enclosure
Transformer
Field adjustable SPE electronic overload relay
Grounding Lug Two year warranty - standard
Complete door mounted operator control package
Circuit Breaker with Operator 480/240: 120 fused control power transformer
CBRCI (Type) Three wires in/out installation and startup
Combination or non-combination
NEMA Rated Contactor

SPE Electronic Overload Relay

Provided with SPE Electronic Overload Relay


SPE electronic overload relays provide field adjustable,
precise motor protection, including:

Adjustable overload class (130)


Wide range of current adjustments
1 NO and 1 NC auxiliary contact
Current imbalance detection
Phase loss detection
Phase reversal protection
Trip free design
Test function/trip indication
Fault indication
SPE Electronic Overload Relay

Return to the
6-2 benshaw.com Table of Contents
Prepackaged Full Voltage Starters
With Door Mounted Controls
NCRCI Non-Combination Full Voltage Non-Reversing Starters
CBRCI Combination Full Voltage 480V Non-Reversing Starters
CBRCI Combination Full Voltage 240V Non-Reversing Starters
NEMA 12/3R enclosure Door-mounted start
and stop push-buttons
cUL listed
Door-mounted overload
NEMA rated contactor and,
reset push-button
separately mounted SPE
overload relay Red run indicator light
480/240:120 fused control (2) Auxiliary contacts
power transformer NCRCI CBRCI
Hand off auto selector switch

NCRCI 240V or 480V


NEMA Horsepower
Model Number NEMA Size 240V 480V Dimensions (in.) Weight List Price
NCRCI93R 1,2,4 00 1.5 2 14 x 10 x 7 30 $1,055.00
NCRCI183R 1,2,4 0 3 5 12 x 10 x 8 30 $1,075.00
NCRCI323R 1,2,4 1 7.5 10 12 x 10 x 8 32 $1,095.00
NCRCI503R 1,2,4 2 15 25 16 x 12 x 9 32 $1,200.00
NCRCI853R 1,2,4 3 30 50 16 x 12 x 9 60 $1,250.00
NCRCI1503R 1,2,4 4 50 100 16 x 12 x 9 60 $1,945.00
Web stocked

CBRCI 480V
Model Number NEMA Size CB Trip NEMA HP Dimensions (in.) Weight List Price
CBRCI9-4-3R 1,4 00 15 2 20 x 16 x 10 48 $1,495.00
CBRCI18-4-3R 1,4 0 20 5 20 x 16 x 10 48 $1,525.00
CBRCI32-4-3R 1,4 1 30 10 24 x 12 x 10 63 $1,725.00
CBRCI50-4-3R 1,4 2 70 25 30 x 12 x 10 63 $1,895.00
CBRCI85-4-3R 3,4 3 100 50 36 x 16 x 10 125 $2,225.00
CBRCI150-4-3R 3,4 4 200 100 36 x 16 x 10 125 $2,375.00
CBRCI300-4-3R 3,4 5 400 200 48 x 24 x 16 250 $4,225.00
Web stocked

CBRCI 240V
Model Number NEMA Size CB Trip NEMA HP Dimensions (in.) Weight List Price
CBRCI9-2-3R 1,5 00 15 1.5 20 x 16 x 10 48 $1,495.00
CBRCI18-2-3R 1,5 0 20 3 20 x 16 x 10 48 $1,525.00
CBRCI32-5-2-3R 1,5 1 40 5 24 x 12 x 10 63 $1,725.00
CBRCI32-7.5-2-3R 1,5 1 50 7.5 24 x 12 x 10 63 $1,725.00
CBRCI50-2-3R 3,5 2 70 15 30 x 12 x 10 63 $1,895.00
CBRCI85-2-3R 3,5 3 125 30 36 x 16 x 10 125 $2,225.00
CBRCI150-2-3R 3,5 4 200 50 36 x 16 x 10 125 $2,375.00
1) Units can be shipped via air and/or parcel.
2) Units are built as 480V w/dual tap transformer and fusing for 240 volt.
3) Units cannot be shipped via air - they must ship by common carrier.
4) Units are in stock.
5) Units are not stocked - allow 2 weeks for shipping.

Return to the
Table of Contents 6-3
Pump Control Starters
Engineered / Configurable Pump Panels
Engineered / Product Highlights:
Benshaws pump control panels are UL listed and are available as NEMA HP rated.
Configurable A NEMA 3R enclosure design makes these panels ideal for a wide range of heavy

Combination Full duty pumping and irrigation applications.

Al panels are service entrance "SUSE" rated and backed by Benshaws unmatched
Voltage Starters / quality and 24/7 service.

NEMA 3R Heavy duty performance, low cost and configurability make these pump control panels
an exceptional value. Choose a standard configuration or select options from the list
NEMA Size 16 / NEMA 3R of factory modifications on page 6-7.***

Enclosed (with Solid State Standard Features:


240/480 volt, three phase
Overload Protection)
Heavy duty fusible switch or circuit breaker (low profile)*
Class R fuse clip**
Flange operated disconnect
Solid state overload and pump protection (Class 10)
HOA switch
Start push button
Outdoor rated NEMA 3R enclosure
Oversized panel
Defeatable disconnect
UL listed panel
Ground lug
Service entrance rated
Factory Modified Options:
Pre-wired motor and pump protector relay
Power surge lightning protection
Pre-wired time clock (24hr)
Pre-wired control transformer (120 V)
Electronic overload phase protection relay
Pre-wired panel heater
Disconnect switch interlock
Circuit breaker shunt trip
Back spin protection
Elapsed time meter
Power, run and fault indicator lights
Extra capacity CPT 100 or 150 VA

* 240 V units are built to order. Please allow two weeks for shipment.
** Fuse not provided. Recommend Class R type, dual element delay.
*** Consult factory for additional details on a variety of options.

Return to the
6-4 benshaw.com Table of Contents
Engineered / Configurable Pump Panels
Factory Options
Factory modifications are available for all Benshaw pump panels.

Pilot Devices Options Advanced Motor Protection Options Standard Capacity Options
Run Pilot Light (Red) Electronic Overload (Class 1~30)* 240 V Primary
Run Pilot Light (Green) Digital Overload (Class 1~60)* 480 V Primary
Off Pilot Light (Green) Pump Saver 777 - Voltage Current 150VA Extra Capacity Options
Protection
Off Pilot Light (Red) 240 V Primary
Pump Saver 777 - LR - kW Protection
OL Trip Pilot Light (Yellow) 480 V Primary
* Requires 120 V control power.
On Pilot Light (Red)
Pilot lights are full voltage supplied at same
On Pilot Light (Green) voltage as contactor coil.
Extra Auxiliary Contact Blocks Options
Enclosure Mounted Options
Factory Installed 1 N/O and 1 N/C
Lightning Surge Protector
Factory Installed 2 N/O and 2 N/C
Time Clock 24Hr.
Meters Option
Space Heater*
Elapsed Time Meter (Analog,
Disconnect Switch Interlock
Non-Resettable)*
Back Spin Protection*

* Requires 120V control power.

Return to the
Table of Contents 6-5
Notes

Return to the
6-6 benshaw.com Table of Contents
Notes

Return to the
Table of Contents 6-7
Notes

Return to the
6-8 benshaw.com Table of Contents
Variable frequency.
Unchanging innovation.
Introducing the M2L 3000 Series
Medium Voltage Variable Frequency Drive.

The M2L 3000 Medium Voltage Variable Frequency Drive is a step change Benefits of the M2L 3000 include:
in motor control power technology. Though designed for industrial
Compact Modular Design
applications, it benefits from Benshaws wide ranging experience in defense
and nuclear-related technologies, an arena where products must meet the Arc Resistant
most rigorous standards and where failure is simply not an option. Installation Flexibility

Our innovative patented topology modular multilevel converter (M2LC) Energy Efficiency
is powered by state-of-the-art hardware and software control. Our Robust Control Architecture
control algorithms are setting the stage for the next generation of VFDs.
Developed, designed and
manufactured in the USA.
Supported around the globe.

To learn more about the M2L 3000,


visit http://benshaw.com,
call 412-968-0100 or e-mail
BenshawRFI@regalbeloit.com
24/7 Technical Support Repairs
Benshaw is dedicated to providing Repairs are made on Benshaw equipment by trained, experienced
comprehensive 24-hour-a-day, 7-day-a-week personnel, using the latest diagnostic and test equipment.
phone support. Benshaw provides repair,
Field Services are performed on-site by skilled technicians,
spare parts, field engineering, retrofit and
engineers or complete teams if needed, including:
training services, when and where you need
us. You can count on our experienced team, Start-up commissioning
backed by the latest diagnostics and repair Field repairs
tools and an extensive parts inventory to
support your operations. Field analysis/data collection
Call 1.800.203.2416 Preventative maintenance
24/7 Hotline Support from our operations Retrofits
in Pittsburgh and Listowel (Canada):

Technical phone support The Benshaw Product Line


Overnight parts shipment A wide range of motor controls and drives is available.
24-hour service dispatch Solid-state starters fractional up to 30,000HP at 15kV
Coordination of all service capabilities LV AC drives to 2,000HP, MV AC drives to 10,000HP
Electromechanical controls to 800A
Benshaw Express is a 24/7 online inventory and
order entry system for authorized Benshaw distributors:

24/7 shipment
Air or truck delivery

Visit us online at
benshaw.com and
benshawexpress.com,
or contact:

BENSHAW, Inc.
615 Alpha Drive
Pittsburgh, PA 15238
Phone: 412.968.0100
Fax: 412.968.5415

BENSHAW Canada
550 Bright Street East
Listowel, Ontario N4W 3W3
Phone: 519.291.5112 A Regal Brand
Fax: 519.291.2595

www.regalbeloit.com
Specifications are subject to change without notice.
2015 Regal-Beloit Corporation MKT 125-013R Printed in the USA