Vous êtes sur la page 1sur 2

OTDR report

Job info
Job ID : Reason :
Contractor : Operator A :
Customer : Operator B :
Test date : 7/23/2017 (6:36:34 AM GMT+1:00) File : C25.trc

Cable info
Fiber ID : Fiber18 Cable ID :
Location A : Location B :
Cable mfr. : Type :
Subset ID : Color ID :

Link measurements
Span loss : 5.884 dB Avg. splice loss : 0.187 dB
Span length : 11.2372 km Max. splice loss : 0.362 dB
Average loss : 0.524 dB/km Span ORL : 0.00 dB

OTDR trace

dB

45.00

40.00

35.00

30.001

25.00

20.00

5
15.00

2 34 7
10.00
AB 6
8 9
5.00

0.00
2 4 6 8 10 12 14 16 18 km

Signature : _________________________ Date : 8/8/2017


Corning Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Merged Fault --- -46.6 0.000


-48.7
0.0000 -46.6
Fiber Section (2.4246 km) 0.846 0.349 0.846
2 2.4246 Non-Reflective Fault 0.101 0.947
Fiber Section (0.3854 km) 0.089 0.232 1.036
3 2.8099 Non-Reflective Fault 0.172 1.208
Fiber Section (0.1914 km) 0.096 0.500 1.303
4 3.0013 Non-Reflective Fault 0.362 1.666
Fiber Section (2.2740 km) 0.563 0.247 2.228
5 5.2753 Reflective Fault 0.521 -13.8 2.750
Fiber Section (3.1723 km) 0.902 0.284 3.652
6 8.4477 Non-Reflective Fault 0.115 3.767
Fiber Section (1.0745 km) 0.154 0.143 3.921
7 9.5221 Reflective Fault 1.676 -32.7 5.597
Fiber Section (1.0438 km) 0.104 0.100 5.701
8 10.5660 Reflective Fault (Possible Echo) 0.116 -38.7 5.817
Fiber Section (0.6712 km) 0.067 0.100 5.884
9 11.2372 Reflective Fault --- -38.3 5.884

Marker info
A : 0.5002 km, 17.551 dB B : 0.7503 km, 16.679 dB
a : 0.2501 km, 37.565 dB b : 1.0004 km, 16.435 dB
A to B distance : 0.2501 km, 0.872 dB A to B ORL : 49.04 dB
3-pt. reflectance : -23.3 dB A to B LSA att. : 3.286 dB/km
4-pt. Ev. loss : 19.946 dB

Test and cable setup


Wavelength : 1550 nm (SM-9m) Acq. time : 15 s
Filename : C25.trc Pulse width : 2.5 s
Hardware : MAX-730B-M3-EA Helix factor : 0.00 %
Serial number : 903132 Splice loss threshold : 0.020 dB
Software : N/A Reflectance threshold : -72.0 dB
Range : 20.0000 km End-of-fiber threshold : 5.000 dB
IOR : 1.468325
RBS : -81.87

Signature : _________________________ Date : 8/8/2017


Corning Page 2 / 2

Vous aimerez peut-être aussi