OPERATION ON DRAINAGE SYSTEM OF SMALL STEAM TURBINE
The valve number refers to ATTACHMENT I.
1 CHECK BEFORE START-UP
The status of all drain valves is as follow before start-up of steam turbine:
VLV NO VLV NAME STATUS RESULT
V01 Live steam drain first valve Close V02 Live steam drain second valve Close
V11 ETV inlet drain valve Close
V21 GV inlet drain valve Close V31 Nozzle box drain valve Close V41 ST case drain valve Close V51 Exhaust steam drain valve Close VX1 Main drain valve Open
VX2 Front steam sealing drain valve Open
VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open
2 WARM-UP OF LIVE STEAM PIPING
The status of all drain valves is as follow in this period:
VLV NO VLV NAME STATUS RESULT
V01 Live steam drain first valve Close
V02 Live steam drain second valve Close
V11 ETV inlet drain valve Open V21 GV inlet drain valve Close V31 Nozzle box drain valve Close VLV NO VLV NAME STATUS RESULT V41 ST case drain valve Close V51 Exhaust steam drain valve Close
VX1 Main drain valve Open
VX2 Front steam sealing drain valve Open VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open
NOTE: IF NEED, MAY OPEN V01 AND V02 TO ACCELERATE
WARM-UP PROGRESS.
3 WARM-UP OF STEAM TURBINE
The status of all drain valves is as follow in this period:
VLV NO VLV NAME STATUS RESULT
V01 Live steam drain first valve Close
V02 Live steam drain second valve Close V11 ETV inlet drain valve Close V21 GV inlet drain valve Open V31 Nozzle box drain valve Open V41 ST case drain valve Open
V51 Exhaust steam drain valve Close
VX1 Main drain valve Open VX2 Front steam sealing drain valve Open VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open
4 RUNNING
The status of all drain valves is as follow in this period:
VLV NO VLV NAME STATUS RESULT V01 Live steam drain first valve Close V02 Live steam drain second valve Close
V11 ETV inlet drain valve Close
V21 GV inlet drain valve Close V31 Nozzle box drain valve Close V41 ST case drain valve Close V51 Exhaust steam drain valve Close VX1 Main drain valve Open
VX2 Front steam sealing drain valve Open
VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open
5 SHUT-DOWN
The status of all drain valves is as follow in this period:
VLV NO VLV NAME STATUS RESULT
V01 Live steam drain first valve Close
V02 Live steam drain second valve Close
V11 ETV inlet drain valve Open V21 GV inlet drain valve Open V31 Nozzle box drain valve Open V41 ST case drain valve Open V51 Exhaust steam drain valve Open
VX1 Main drain valve Open
VX2 Front steam sealing drain valve Open VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open NOTE: AFTER EMERGENCY TRIP VALVE, EXHAUST STEAM MANUAL VALVE AND SPRAY WATER MANUAL VALVE ARE CLOSED, OPEN V11, V21, V31, V41 AND V51 VALVES. WHEN THE TEMPERATURE OF STEAM TRUBINE CASING IS LESS THAN 100 DEGREE CELSIUS, CLOSE THOSE VALVES.
6 LONG TERM STOP
The status of all drain valves is as follow in this period:
VLV NO VLV NAME STATUS RESULT
V01 Live steam drain first valve Close V02 Live steam drain second valve Close
V11 ETV inlet drain valve Close
V21 GV inlet drain valve Close V31 Nozzle box drain valve Close V41 ST case drain valve Close V51 Exhaust steam drain valve Close VX1 Main drain valve Open
VX2 Front steam sealing drain valve Open
VX3 Rear steam sealing drain valve Open VX4 ETV steam sealing drain valve Open ATTACHMENT I