Vous êtes sur la page 1sur 1

GIRBAU ED DRYERS

Girbau ED Dryers Capacity Dimensions and weights Electrical Supply Ventilation Gas Supply Steam Dryers Exhaust Ducting

Nominal Steam Press /


Top maintenance dist.

Outlet connection (in)


Gas connection (in)
(top cover to ceiling)

Supply G20 20 mbar

Inlet Connection (in)


Gas/Steam Models

Ventilation Dryers
(Without louvers)
Back Maintenance

Max Pressure**
Electrical supply

Electrical supply
Electric Models
Capacity (1/20)

Capacity (1/25)

Min-Max (bars)
kw (BTU/h)
Weight (kg)
Gas/Elect.

Switch (A)

Switch (A)

Size (mm)
(kg) (lbs)

(mm HO)
(kg) (lbs)

distance
W (mm)
H (mm)

H (mm)

D (mm)
Steam
Machine
Pictures
model

1Ph+N+PE ER: 3Ph+N+PE


240V 50 Hz 6 415V 50 Hz 20 600 mm 500 mm 500 cm
3.70A - 0.89Kw 16A - 10 Kw
13 10.4 18
ED 260 1522 1553 798 985 249 3/4" 8/6-9 1/2" 1/2" 160 7
28.6 22.9 (61,419)
3Ph+N+PE EN: 3Ph+N+PE
415V 50 Hz 6 415V 50 Hz 25 600 mm 500 mm 500 cm
2.3A - 0.89Kw 21A - 13 Kw

1Ph+N+PE ER: 3Ph+N+PE


240V 50 Hz 6 415V 50 Hz 25 600 mm 500 mm 500 cm
4A - 0.94Kw 21A - 13 Kw
17 13.6 21
ED 340 1522 1553 798 1173 279 3/4" 8/6-9 1/2" 1/2" 160 7
37.4 30 (71,655)
3Ph+N+PE EN: 3Ph+N+PE
415V 50 Hz 6 415V 50 Hz 40 600 mm 500 mm 500 cm
2.5A - 0.94Kw 29A- 19 Kw

1Ph+N+PE ER: 3Ph+N+PE


240V 50 Hz 10 415V 50 Hz 40 600 mm 500 mm 500 cm
6.6A - 1.59Kw 31A - 19 Kw
23 18.4 31
ED 460 1828 1859 1002 1056 339 3/4" 8/6-9 3/4" 1/2" 200 7
50.7 40.6 (105,776)
3Ph+N+PE EN: 3Ph+N+PE
415V 50 Hz 10 415V 50 Hz 50 600 mm 500 mm 500 cm
4.7A - 1.59 Kw 41A - 26 Kw

1Ph+N+PE ER: 3Ph+N+PE


240V 50 Hz 10 415V 50 Hz 50 600 mm 500 mm 500 cm
7.1 A - 1.64 Kw 41A - 26 Kw
33 26.4 39
ED 660 1828 1859 1002 1343 386 3/4" 8/6-9 3/4" 1/2" 200 7
72.8 58.2 (133,074)
3Ph+N+PE EN: 3Ph+N+PE
415V 50 Hz 10 415V 50 Hz 63 600 mm 500 mm 500 cm
5A - 1.64Kw 50A - 32 Kw

*Minimum and maximum temperature: 5 C / 40C


*Maximum humidity: 80% without condesnation A MINIMUM PRESSURE OF Ventilation: Recommended location as close to the dryer as possible. It is advisable to create 2
*Maximum altitude: 3000 m 20 mbars HAS TO ARRIVE AT openings in opposite walls, one located at the top of the premises and another at the bottom.
*Vibrations: free THE DRYER WHEN THE REST -Ventilation openings with louvers will restrict airflow. The opening must be increased by 50% to
*Sound level: <70 dB OF THE GAS APPLIANCES compensate for area taken up by louvers.
**Maximum pressure. Registered with the machine running ARE RUNING. -If it is necessary to duct the ventilation to the ironer, increase the area of ductwork by 25%.
empty and at a distance of approximately 1 m (40 in) from the
exhaust duct connection
*EN: Normal electric - ER: Electrical Reduced
10/6 Gladstone Road
Castle Hill, NSW 2154 (Australia)
Tel 02 9894 0399 Fax: 02 9894 0835
www.girbau.com.au