MDT268 COMPOSITION
Ancrage au batiment
Hsc = 176,3 m
ancrage serr 35
Hsc = 141,3 m
28
26 129,07 m
Hsc = 106,3 m
21
19 94,07 m 19 94,07 m
Hsc = 66,3 m
13
a1= 1.38 m
b1= 2.76 m
b= 2.444016127 m (ctg alpha + ctg gama) / (ctg beta + ctg gama)= 1.053279577
Forces on Ties: Plus Sign means Tension force Minus Means Compression Force
The following Cases must be Cosnidered when Finding the Maximum force on Ties:
Tie I II III IV
A 190 T 190 C 65 C 65 T
B 27 C 27 T 237 T 237 C
C 148 C 148 T 160 C 160 T
Summary: case 1=(+ Md + case 2=(-Md -Ha) case 3=(-Md +Ha) case 4=(+Md -Ha)
NFT Specialized in Tower Cranes L.L.C. - P.O. Box 28037 - Abu Dhabi, U.A.E.
Phone : +971-2-6730778 - Fax : +971-2-6730434 - E-mail : nftuae@emirates.net.ae - Website : www.nftcrane.com
CRANE: C8
CRANE TYPE: POTAIN MDT 268 J12 C8 MDT 268 J12
JIB LENGTH: 40 m IN SERVICE FORCE: 128 KN
CLIENT: SAUDI OGER OUT OF SERVICE FORCE: 337 KN
PROJECT: WAQF - KSA SLEWING TORQUE: 270 KN
a1= 1.38 m
b1= 2.76 m
b= 2.444016127 m (ctg alpha + ctg gama) / (ctg beta + ctg gama)= 1.053279577
Forces on Ties: Plus Sign means Tension force Minus Means Compression Force
AX OUT SERVICE AY OUT SERVICE
A= 163.9622671 KN 81.99999998 142.0281662
BX OUT SERVICE BY OUT SERVICE
B= 276.1675853 KN 129.5741513 243.6935356
CX OUT SERVICE CY OUT SERVICE
C= -405.6930232 KN 125.4608997 386.1289456
The following Cases must be Cosnidered when Finding the Maximum force on Ties:
Tie I II
A 164 T 164 C
B 276 T 276 C
C 406 C 406 T
Summary: case 1=( + Ha) case 2=( - Ha)
NFT Specialized in Tower Cranes L.L.C. - P.O. Box 28037 - Abu Dhabi, U.A.E.