Hardware Required
A desktop or a laptop PC.
Software Required
Microsoft Excel 97 or newer is required to open the energy
calculation workbook.
Files Provided
The Efficiency Tool file is incorporated into Excel workbook
EfficiencyTool10.xls.
Installation
The calculation workbook can be opened and run from the
floppy disk or CD-ROM or the file can be copied to a hard disk.
Hard disk installation is recommended if the program is to be
used frequently.
Or
In both cases, Excel will open in the full screen mode which
means that the toolbars you normally see with Excel are
hidden. The intention of this is to make the user interface of
Tool more clear.
Macros
When opening the Efficiency Tool workbook, it is possible that
Excel warns about possible macro viruses. In order to the tool
to operate properly, Enable macros option should be
selected. It is recommended that the workbook be checked for
viruses with an up-to-date anti-virus software before opening
it.
4
Figure 1 The opening sheet of the Efficiency Tool
Data Sheet
Next, a data sheet with a Filling instructions window will
open for the selected option. Figure 2 shows a typical data
sheet. The data sheets are calculation spreadsheets where
data is entered and results are presented in numerical form.
There are three types of data sheets; one for each replacement
option (drive/motor/both). There is also a separate data sheet
for no-replacement case.
5
Figure 2. Data sheet when opened for the first time
Load Data
In this field the load of the motor is specified by means of type,
maximum power, annual running time and its distribution. Fig
3 illustrates these.
6
Figure 3. Load data field
First, pick the applicable load type from the drop-down list. The
options are:
Other. In case that the load type does not fall into any of
the above mentioned categories, it is possible to specify the
load type by means of mechanical power and
corresponding rotating speed at several operating points.
Up to nine operating points can be fixed.
7
Beneath the load type box, you need to specify the maximum
mechanical power required in kW and the corresponding motor
rotating speed. From these values the torque at this point is
calculated and is shown.
8
The next information applies when Both the drive and the
motor option has been selected. This is the full replacement
case. If you have selected one of the three other options,
please ignore the non-applicable parts in the following: (for
example, if you have selected to replace only the drive, the
data on the new motor does not apply to your case because
there is no new motor!)
Motor Data
Figure 4.
9
Drive data
The Efficiency Tool takes into account only two parameters of
the drives (frequency converters) in calculations: Nominal
efficiency and the switching frequency. So, the nominal power
of the drive is not needed. The Efficiency Tool simply assumes
that the capacity of the drive is adequate for the motor system
defined earlier. This means that the load and the motor
determine the necessary output power of the drive.
Like with motors, the drive data is entered in two boxes: one
for old drive and the other for new.
Old drive
If the old drive you are going to replace with a new one is of
Strmberg/ ABB design (SAMIs), you can pick the model
straight from the drop-down (or up!) list. The possible types
are SAMI A, B, C, Ministar, Microstar, Flowstar, and STAR.
If you are replacing a type not listed here, select the last
option Other. Now, you need to know the nominal efficiency
of the drive and its switching frequency and enter them into
the appearing window. This data can be found from the
documentation of your drive. If not found, contact the drive
manufacturer.
New drive
The values for ACS 600 are default values. These are:
efficiency 98% and switching frequency 3000 Hz. If the line
voltage is 690 V, then use 2000 Hz as the switching frequency
for ACS 600.
Economic data
In order to be able to evaluate the replacement in economic
measures, the following data is needed:
10
Energy Price
The electricity price in EUR per kWh.
Investment cost
The price of the new drive system (motor or drive or both) plus
installation.
Interest rate
This represents the cost of capital for the customer. In
calculations, the value entered here has an effect on the net
present value. Enter the value in percent form (e.g 10%).
Service life
The prospective service life of the new drive system in years
(e.g 12 years).
Results
Energy consumed chart
The energy consumed chart
illustrates in two columns the
calculated annual energy
consumption of the old drive
system (left column) and the
new one (right). The kWh
values are displayed on top
of each column.
Greenhouse Gas
Reduction
A reduction in the energy
consumption of a drive
system leads to lesser
greenhouse gas (GHG) emissions. Carbon dioxide CO 2 is the
most important of the greenhouse gases. Efficiency Tool
estimates the magnitude of
Figure 8. Calculation Results
11
the GHG reduction resulting from the motor/drive replacement
is by the in kg/ year. In order to be able to calculate the
reduction, the specific GHG emission is required as input data.
GHG emission per unit means that how much CO2 is emitted
when one kWh of electricity is consumed. The value depends
on how the electricity is produced. For example, coal-fired
condensing power plant produces high CO 2 emissions, whereas
nuclear power causes practically no CO2 emissions. The value
on which the calculations are based on can be changed by
clicking the spinner buttons. The range is 0-2.5 kg CO 2 per
kWh at 0.1 kg increments. The default value is 0.5 kg /kWh
which can be used to reflect the average European electrical
power generating mix.
Payback period
The direct payback period of the replacement in years. Direct
means that no interest rate is taken into account.
NPV
The net present value is a more advanced investment criterion
than the payback period. If NPV is positive, the replacement
project is profitable.
Profitability index
Equals NPV per investment. Profitability index can be used to
rank replacement projects.
Buttons
Adjust screen size
Efficiency Tool is optimized to computer screen resolution of
1024 x 768 pixels, or greater. If the desktop area is smaller
(e.g 800x600), not the entire worksheet area is visible. To
correct this, click the Adjust Screen Sizebutton.
Restart
Shows the opening sheet of Efficiency Tool. Here you can
change the scope of replacement. For example, if you initially
planned to replace only the drive and made the calculations
according to that, and now, you decide it would be better to
replace also the motor, use this restart feature.
12
Print to the default printer
Click this button to get a paper copy of the Efficiency Tool
calculations.
Customer, application
The customer and application data can be entered to the top-
right corner of the Efficiency Tool sheet in order to be able to
later identify the calculations made.
13
3. Explanation of calculations
14
Rotating Operating
Load Max.
speed rpm time profile
type mech.
at max
power
power
Old New
Calculating electrical Calculating electrical
motor motor
power required by old power required by
data data
motor new motor
Old New
Calculating electrical Calculating electrical
drive drive
power required by old power required by
data data
drive new drive
Specific
GHG
emission
Difference = Annual energy saving
Energy
price
Annual
GreenHouse Gas
reduction
Investment
cost
Investment
appraisal Annual money
calculations saving
Interest
rate Net Present
Value
Profitability index
Service
life
Estimated cut in
energy costs
Load calculation
After the user has given the maximum power Pmax and the
corresponding motor rotating speed and the load type,
Efficiency Tool calculates the mechanical power values at
different speeds using the formula
15
a
n
P mech Pmax
n nom
Table 1 Different load types and the corresponding exponent values for
determining mechanical power at different speeds in Efficiency Tool
P T
n
2
n rpm
2
60
n rpm
P T 2
60
16
P T nrpm
30000
Motor calculation
The electric power taken by a three-phase motor is given by
the following equation
9
Pharm Pmech
f sw
17
The harmonic loss is inversely proportional to the switching
frequency fsw of the AC drive, and does not depend on the load.
Drive calculation
Electric power drawn by the motor equals the electric power
supplied by the drive at any given time:
1 drive
Pdrive _ nomloss Pdrive _ out ( nom )
drive
f T
Pdrive _ loss 0.35 Pdrive _ nomloss 0.1 Pdrive _ nomloss 0.55 Pdrive _ nomloss
f nom Tnom
18
Energy calculations
Knowing the power consumptions at different system speeds
and their durations, it is easy to proceed to energy
consumptions. Energy consumed by the drive system Ei at a
given operating point equals the electrical input power to the
drive Pdrive_in at that point multiplied by the duration ti of the
operation at that point.
Ei Pdrive _ in t i
20%
E total E
i 100%
i
Economic calculations
Annual money saving is the reduction in energy costs and it is
achieved when the energy saving per year is multiplied by the
energy price
19
EnergySaving
EnergySaving %
E oldsystem
C investment
PBP
MoneySaving
n
MoneySaving
NPV C investment
t 1 1 r t
where n is the service life of new equipment in years, r is the
discount rate, or the cost of capital.
NPV
PI
C investment
20
Example of a Data Sheet