Impeller/Wheel Diameter: 7.87


F
C G
L

E E
B

H
D D
P

A
Q
O
4 x .25"
I
M K J N
Optional Stainless Steel Impeller/Wheel Available
Metal stand optional, not standard. Shown with fan (see Accessories) for dimensional data only. Motor frame sizes may vary upon type of motor used.

DIMENSIONAL DATA (inches)


A B C D E F G H I J K M N O
1
8.18 11.88 9.44 6.30 6.63 15.25 6.17 5.25 1.25 3.30 3.70 7.08 13.38 9.44

2
8.18 11.88 9.44 6.30 6.37 13.37 6.17 5.50 1.25 3.30 3.70 7.08 13.38 9.44
1 - Standard Gray Polypropylene Housing Assembly 2 - Black Carbon Fiber Impregnated Polypropylene Housing Assembly For Explosion-Proof Series

L P Q BLOWER TYPE SHOWN WITH OPTIONAL ROOF UNIT KIT



20.02 3.50 12.94 PLA20SS2P

17.59 3.50 12.94 PLA20ST2P

21.08 3.50 12.94 PLA20XS2P

21.08 3.50 12.94 PLA20XT2P

18.22 3.50 12.94 PLA20SS4P

17.60 3.50 12.94 PLA20ST4P

20.00 3.50 12.94 PLA20XS4P
See Accessories Performance and Dimensional Data Sheets

20.00 3.50 12.94 PLA20XT4P for Roof Unit Kits


18.22 3.50 12.94 PLA20SS6P
LWA

14.70 2.48 11.92 PLA20ST6P R.P.M. dB (A)

19.90 3.50 12.94 PLA20XS6P Noise Level 1150 46
(Ducted inlet/outlet) 1725 56

14.81 2.48 11.92 PLA20XT6P Measured at 5 feet. 3450 73
PLASTEC 20
6.50

6.00
3450 RPM
1.1 kW
5.50 1.5 HP

5.00
Model
P20-2
4.50
Static Pressure InWG

4.00

3.50

3.00

2.50
AMCA 210-85 ISO 5801
2.00
1725 RPM
0.25 kW
1/ 3 HP
1.50
Model
1140 RPM P20-4
1.00
0.18 kW
1/ 4 HP

0.50 Model
P20-6
0.00
0 200 400 600 800 1000 1200 1400 1600 1800

Airflow CFM
For Weather Protection see optional accessory
Weather Hood Enclosed Pedestal Model WH3,
pictured at right. Also see Model WH5 Aluminum
Weather Hood pictured at left.

ROTATION AND DISCHARGE FOR CENTRIFUGAL FANS


Standard
Optional Field Adjustable Positions
Position

Counter- Counter-Clockwise Counter- Counter- Counter- Counter- Counter-Clockwise Counter-Clockwise


Clockwise Top Angular Clockwise Clockwise Clockwise Clockwise Bottom Bottom Angular
Up Blast Up Blast Top Horizontal Top Angular Down-Blast Bottom Angular Horizontal Up Blast
CCW 360 CCW 45 CCW 90 Down Blast CCW 180 Down Blast CCW 270 CCW 315
CCW 135 CCW 225
Notes:
(1) Direction of rotation is determined from the drive side of fan. Standard position is up-blast CCW 360.
(2) On single inlet fans, drive side is always considered as the side opposite fan inlet.
(3) Clockwise available upon request.