Vous êtes sur la page 1sur 7

Cam switches

Reversing - star delta - pole changing

Refer Catalogue ECS No. of


Switch rating chambers/ Cat. No.
AC 21 AC 23 switching 22.5 mm single Cat. No.
amps kW angle hole mount panel mount
OFF
W3 reversing switch 3 @ 415 V
FOR REV
phase panel mounted 20 5.5 3/45 B2N W3-20C B2N W3-20P
25 11 3/60 V2N W3-20C V2N W3-20P
B2N V3N 32 15 3/60 V3N W3-32C V3N W3-32P
0
1 1
50 22 3/60 VN W3-40P
63 30 3/60 VN W3-63P
115 55 3/60 VN W3-100P
VN40 VN150 150 75 3/60 i VN W3-150P

FOR
OFF
REV WE4 single phase reversing switches for motors with capacitor or centrifugal switch panel mounted

V2N V3N @ 240 V


0
1 1 25 5.5 3/60 V2N WE4-20C V2N WE4-20P
32 7.5 3/60 V3N WE4-32C V3N WE4-32P
50 11 3/60 VN WE4-40P
VN40

KOM motor starter control off, on, start with spring return to on panel mounted
0

1 @ 240 V

START 25 5.5 1/60-30 V2N KOM-20C V2N KOM-20P

V2N

Y star delta switch panel mounted @ 415 V

25 11 4/60 V2N Y-20C V2N Y-20P


0
Y 32 15 4/60 V3N Y-32C V3N Y-32P
50 22 4/60 i VN Y-40P

V2N VN40

P11 pole-changing switch for 2 speeds (single winding) panel mounted


0
@ 415 V
1 2
25 11 4/60 V2N P11-20C V2N P11-20P
32 15 4/60 i V3N P11-32C V3N P11-32P
50 22 4/60 VN P11-40P
V2N VN40

KIM impulse switch NEW


@ 240 V
0 1
20 3.0 1/30 B2N KIM-20C B2N KIM-20P
25 5.5 1/30 V2N KIM-20C V2N KIM-20P

B2N V2N

Notes: Standard engraving as shown, alternative engravings available on request.


Standard plates have silver background with black knob.
Yellow plate with red knob available on indent.
i Available on indent only. (Local manufacture).
Elektra specials order form

When completed fax form with wiring diagram and order number to your nearest NHP branch or representative.
THIS SIDE MUST BE COMPLETED
Name:
Company: ELECTRICAL ENGINEERING PRODUCTS PTY. LTD.
A.B.N. 84 004 304 812
Address: 43-67 RIVER STREET, RICHMOND, VIC. 3121

Phone: (03) 9429 2999. Fax: (03) 9429 1075

Phone No.:

Order No. Date: _____/_____/_____ Quantity: Date required: ____/____/____

A SWITCH TYPE & SIZE (AC 21)

V2N (25 A) V3N (32 A) VN (50250 A) Rating req.


QUANTITY or or AMPS

KW (AC 23)

B FIXING
SINGLE HOLE (C)
(V2N & V3N ONLY) PANEL (P) OFF
BASE (B) ENCLOSED (LE)
or or or

C PLATE & KNOB STANDARD 3SD ES (OFF/ON ONLY)


(option) or or

KEY OPERATED (ZD/ZE) KEY INTERLOCKED (ZSH)


(B2N & V2N/V3N ONLY) (EXCEPT B2N) KEY OUT WHAT POSITIONS?
or or

D ACCESSORIES
R1 R2L R2R R2
SPRING RETURN (V2N & V3N ONLY) or or or

QTY? RATING? POSITION CONTACTS CLOSE?


AUXILIARY CONTACTS
AMPS
WPK
IP 65 WEATHERPROOF KIT (PMOUNT ONLY)

TK/TV
DOOR COUPLING WITH INTERLOCK

AT
EXTENDED TERMINALS (VN40-100 ONLY)

EXS LENGTH REQUIRED? FROM BASE OF SWITCH TO TOP PANEL


EXTENSION SHAFT
MM

GOLD CONTACTS (V2N ONLY)

PROTECTIVE BOOTS (B2NVN63)


Elektra specials order form

COMPLETE THIS SIDE or PROVIDE WIRING DIAGRAM


E ENGRAVING AND SWITCH POSITION (NB If ordering plate only,
state size of plate required)

MM
HEADER PLATE
COMMON ESCUTCHEON PLATES REQUIRED? Write engraving required
CAN ALSO BE USED

Posn. Faceplate engraving required


1
2
0
3 330 30
4 315 45
300 60
5
270 90
6
240 120
7
225 135
8 210 150
180
9
10
11
12 Indicate position numbers where switching
positions and engraving is required.

F CONTACT CONFIGURATION
(Indicate switching positions where required)
SWITCHING POSITIONS
1 2 3 4 5 6 7 8 9 10 11 12

1 2

3 4

5 6

7 8
LOAD SIDE TERMINALS
LINE SIDE TERMINALS

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24
Common escutcheon plates

Refer Catalogue ECS


These plates can be ordered by the following Cat. No.
OFF O OFF MAN AUTO 1
ON I ON AUTO MAN 2

EPOO EPOI EPORO EPMA EPAM EP12

2 HIGH OFF STOP OPEN DUTY


1 LOW AUTO START CLOSE S/BY

EP21 EPHL EPOA EPSS EPOC EPDS

LEAD UP SLOW FAST OFF OFF


LAG DOWN FAST SLOW MAN AUTO AUTO MAN

EPLL EPUD EPSF EPFS EPMOA EPAOM

0 OFF OFF OFF OFF NORMAL


1 2 FOR REV ON Y HI LOW TEST

START

EP102 EPFOR EPOOS EPOSD EPHOL EPNT

OFF REMOTE OFF OFF OFF


NORM TEST LOCAL NORM O/RIDE REMOTE LOCAL PUMP 1 PUMP 2 RAISE LOWER

EPNOT EPRL EPNO EPROL EPPOP EPRAOL

OFF OPEN DUTY 2 MED OFF STOP


UP DOWN AUTO CLOSE DUTY 1 DUTY LOW HI LOW HIGH REMOTE LOCAL
1+2

EPUOD EPAOC EPD1D2D3 EPLMH EPLOH EPRSL

OFF OFF OFF OFF OFF OFF


AUTO TEST MAINS GEN MAINS ALT MAINS S/BY AUTO ON OPEN CLOSE

EPAOT EPMOG EPMOAL EPMOS EPAOO EPOOC

OFF OFF OFF OFF OFF OFF


MAINS BYPASS UPS BYPASS 2-1 1-2 SEC GEN SEC AUX ON RESET

EPMOB EPUOB EP2O11 EPSOG EPSOA EPOOR


Note: Special engraved plates available locally upon request.
Cam Switches

OMY
ECON Elektra B2N series cam switches
E
RANG The B2N cam switch design features two half shells that carry the fixed and
moving contacts. These contacts are operated by cams which are fixed to a steel
shaft. This shaft is non-adjustable.
The steel shaft ensures positive switching, while over-switching is prevented by
steel detents and stop washers.
The simple assembly with few compact parts gives the switch not only a higher
mechanical strength, but also important advantages in economy.
The B2N series is available in the single rating of 20 amps AC 21 (static load) and
5.5 kW AC 23 (motor load). By utilising from one to four chambers the B2N range
are available in on/off switches (1 to 4 pole), changeover switches (1 to 4 pole),
reversing and 2 speed switches, and ammeter/voltmeter switches.
Exploded view of a two chamber
B2N cam switch

NEW Elektra V2N, V3N range of cam switches


The new range of V2N and V3N cam switches replaces VN20 and VN32
respectively.
They take into consideration the International standards VDE 0660 and
EN 60 947-3, back of hand protection, according to DIN 57 106 with opened
connecting terminals the V2N/V3N may be used as control, instrument, motor and
main switches.
BROA
V2N/V3N use all common accessories. D RAN
SWITC GE OF
COMB HING
V2N and V3N switches INAT
AVAILA IONS
BLE

Elektra VN standard cam switches from 50 to 250 amp AC 1


The conventional method of constructing a cam switch is chamber by chamber
each chamber having 2 contacts.
This means that by varying the number of chambers and the cams, an extremely
large number of switch programmes can be achieved. NHP assembles this type
of switch in Australia.
The VN range is available in 7 frame sizes rated as follows - AC 21/AC 23
50 amp/22 kW, 63 amp/30 kW, 115 amp/55 kW, 150 amp/75 kW, 250 amp/90 kW.
As with the B2N switch, the VN range is constructed with a steel shaft to give
VN cam switch
reliable operation into the future.
Also, the contact chambers are well sealed against the ingress of dust which can
cause contact failure in other switches.

ST
ROBU
N
DESIG Elektra T series enclosed industrial switches
This very popular range of switchgear is mostly used as a local isolator, reversing
and changeover switch for motor loads and machinery. They are available in
either metal clad or in a strong moulded insulated material. Spare interiors are
available for very frequently used installations.
Available ratings are (AC 21/AC 3):- 25 amp / 8 kW
45 amp / 16 kW
63 amp / 24 kW.

Industrial enclosed switch


Cam switches

Drilling pattern Mounting methods/ordering example


Panel mounting Ordering examples:

15 B2N, V2N, V3N, V2N A3-20P


5 VN40 to VN100 Three pole off/on switch 25 amp panel mounted.
V2N A3-20C
Three pole off/on switch 25 amp single hole mount (22.5 mm)
A

6 VN150
VN250
20

50

Drilling pattern for panel mounting


B2N, V2N, V3N and VN switches
35 VN150 VN250 Switch Front plate
size size (mm) Dim. A (mm)
22.5 mm single hole mounting
B2N/V2N 48 x 48 30
3.2 B2N, V2N, V3N 72 x 72 40
V3N
VN40 72 x 72 47
24.5

VN63 96 x 96 47
VN100 96 x 96 65
VN150 125 x 125 -
22.5
VN250 125 x 125 -
Dimensions in mm

Panel mounting Base mounting Base mounting with door coupling


Notes: DIN rail mounting is possible for B2N, V2N and V3N switches.
1
) With DIN cable lug.
2
) Rated mains voltage DIN IEC 38.
VN "special"
locally assembled switches

The construction of your special Elektra rotary cam switches ensures that a
large number of switching combinations are possible. This, coupled with
the accessories that can be supplied, makes the Elektra range one of the
most comprehensive and a first choice with design and electrical engineers.

All Special locally assembled switches and NHP fitted accessories must
be ordered at time of ordering switch and can not be ordered separately for
fitting by the customer.

Accessories
NHP fitted accessories for the Elektra cam switch range enable standard switches
to have personalised features including:
Spring return feature
Add on auxiliary contacts
IP 65 weatherproof kits
Key operation and key interlocking
Door couplings
Extended cable terminations
Base plate mounting
Extended shafts
Protective boots

Other options
Engraving
Specially built cam switches can often require particular engraving on the front
plate. This can be supplied as requested, refer to Special engraving

Gold contacts for PLCs


Elektra V2N cam switches can be fitted with GOLD contacts for use in very low
voltage switching (PLCs).

Vous aimerez peut-être aussi