MANUAL DE COMISIONAMIENTO BASICO
EQUIPO 7210 SAS-E
Mayo 30, 2011
MENU

1. PROPOSITO..................................................................................................................... 3

2. REQUISITOS.................................................................................................................... 3

2.1 Hardware. ...................................................................................................................... 3

2.2 Software.......................................................................................................................... 3

3. PROCEDIMIENTO............................................................................................................ 3

3.1 Inicializacin del equipo................................................................................................... 3

3.2. Carga de timos al equipo................................................................................................ 9


1. PROPOSITO
Este documento explica la forma del comisionamiento basico del equipo 7210 SAS-E
Service Access Switch Alcatel-Lucent en donde se realiza la carga de software al
equipo.

Este documento explica paso a paso el proceso de arranque cuando se inicia por
primera vez el equipo.

2. REQUISITOS

2.1 Hardware.

 Porttil, se recomienda un equipo con el firewall y antivirus desactivado,


con un acceso de puerto serial y puerto Ethernet.
 Cable de consola, este cable es proporcionado en la caja del equipo.
 Patchcord directo.

2.2 Software

 Software servidor FTP o servidor TFTP


 Versin de timos equipo 7210 SAS-E
 Software para acceso serial (hyperterminal, Putty, CRT, etc.)

3. PROCEDIMIENTO

3.1 Inicializacin del equipo

 Utilizando el cable serial conectar el equipo 7210 SAS-E por medio del
puerto de consola al puerto serial del porttil.
 Configurar el puerto serial con los parmetros que se muestra en la figura.
 Conectar el puerto 1/1/24 del equipo 7210 SAS-E al puerto Ethernet del porttil
mediante el patchcord.
 Configurar el puerto Ethernet del porttil con la direccin IP 192.168.1.1/24.

 Encender el equipo: Al iniciar el equipo el hyperterminal, putty o CRT mostrar la


siguiente informacin:

Alcatel-Lucent 7210 Boot ROM. Copyright 2000-2009 Alcatel-Lucent.


All rights reserved. All use is subject to applicable license
agreements.
Running POST tests from ROM
Testing ROM load area...done
Relocating code...Jumping to RAM
Performing second stage RAM test....passed
Board Serial Number is 'SN12345678'
Bootlog started for Version V-1.0.R1
Build V-1.0.R1 bootrom/mpc 7xxx
Built on Thu Jan 15 14:55:59 IST 2009 by builder in
/builder/ws/panos/main
?Attempting to load from file cf1:/boot.tim
Version L-1.0.R1, Thu Jan 15 13:14:04 IST 2009 by builder in
/builder/ws/panos/main
text:(2996951-->12601888) + data:(550439-->2414000)
Starting at 0xb000000...
Total Memory: 512MB Chassis Type: sas Card Type: badami_7210
TiMOS-L-1.0.R1 boot/mpc ALCATEL SAS-E 7210 Copyright (c) 2000-2009
Alcatel-Lucent.
All rights reserved. All use subject to applicable license
agreements.
Built on Thu Jan 15 13:14:04 IST 2009 by builder in
/builder/ws/panos/main
TiMOS BOOT LOADER
Time from clock is SUN JUL 08 00:38:46 2001 UTC
Switching serial output to sync mode... done
Looking for cf1:/bof.cfg ... not found
Could not find bof.cfg on any of the local drives.
Default Settings
----------------
#uplinkA Port Settings:
uplinkA-port 1/1/1
uplinkA-address 0
uplinkA-vlan 0
#uplinkB Port Settings:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkB-vlan 0
#System Settings:
wait 3
persist off
console-speed 115200
Hit a key within 2 seconds to change boot parms...

 Presionar la tecla enter cuando se muestre el siguiente mensaje


Hit a key within 2 seconds to change boot parms...
 Luego de presionar enter se solicitar un password all se debe digitar
password.

Enter password to edit the Boot Options File


Or CTRL-D to exit the prompt
Password:

 Luego se muestra la siguiente informacin.

You must supply some required Boot Options. At any prompt, you can
type:
"restart" - restart the query mode.
"reboot" - reboot.
"exit" - boot with with existing values.
"diag" - enter the diag shell.
"reset" - reset the bof and reboot.
Press ENTER to begin, or 'flash' to enter firmware update...
Software Location

 Presionar enter.

Software Location
-----------------
You must enter the URL of the TiMOS software.
The location can be on a Compact Flash device,
or on the network.
Here are some examples
cf1:/timos1.0R1
ftp://user:passwd@192.168.1.150/./timos1.0R1
tftp://192.168.1.150/./timos1.0R1

 A continuacin se procede a configurar bof del equipo para que inicie la versin
de timos desde el servidor FTP o TFTP. Durante esta configuracin se
preguntar la direccin de URL donde esta la imagen de timos, la direccin URL
donde esta la configuracin (para este caso se digita none), luego se escribe edit
y se configura el puerto 1/1/24, luego se digita la direccin IP 192.168.1.3/24,
luego solicita la VLAN all se digita null, posteriormente pregunta por la
configuracin del puerto de uplinkB alli presionamos enter, por ultimo pregunta si
se desea guardar el bof (Do you want to save the new settings? (yes/no): all se
digita y.

Software Image URL: tftp://192.168.1.1/both.tim


Configuration File Location
---------------------------
You must enter the location of configuration
file to be used by TiMOS. The file can be on
a Compact Flash device, or on the network.
Here are some examples
cf1:/config.cfg
ftp://user:passwd@192.168.1.150/./config.cfg
tftp://192.168.1.150/./config.cfg
No existing Config URL
Press ENTER, or type 'none' for no Config URL.
Config File URL: none
Boot Interface Management
-------------------------
You specified a network location for either the
software or the configuration file. You need to,
configure either uplinkA or uplinkB ports.
You will be asked to configure the port number, IP address,
static routes, and VLAN Id for uplink ports.
uplinkA Port Setting
--------------------
Existing uplinkA port settings are:
uplinkA-port 1/1/1
uplinkA-address 0
uplinkA-vlan 0
uplinkA port is configured for Boot Interface Management,
Press ENTER to proceed with existing port settings
Or "disable" to disable the port for Boot Interface Management
Or "edit" to change the port settings: edit
Existing uplinkA port for Boot Interface Management is port 1/1/1.
Press ENTER to keep it.
Enter the new uplinkA port number for Boot Interface Management:
1/1/24
Using port 1/1/13 as uplinkA port for Boot Interface Management
You need to assign an IP address for this port.
The IP address should be entered in standard
dotted decimal form with a network length.
example: 192.168.1.169/24
Or type "0" to obtain IP address and static route
through DHCP. Existing IP address and static routes
will be deleted.

uplinkA port is configured to obtain IP address and static route


through DHCP.
Press ENTER to keep it.
Enter uplinkA port IP Address: 192.168.1.3/24
You specified network locations which might require
static routes to reach. You will be asked to
enter static routes until all the locations become
reachable.
Static routes should be entered in the following format:
prefix/mask next-hop ip-address
example: 192.168.0.0/16 next-hop 192.168.1.254
Would you like to add a static route? (yes/no) n
You need to configure the VLAN Id for this port
VLAN Id can be between 0 to 4094. To send out
packets with out any VLAN tags, type "null".
Existing VLAN Id for uplinkA port is VLAN Id 0.
Press ENTER to keep it.
Enter the new VLAN Id for uplinkA port: null
No VLAN Id configured for uplinkA port

uplinkB Port Setting


--------------------
Existing uplinkB port settings are:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkB-vlan 0
uplinkB port is configured for Boot Interface Management,
Press ENTER to proceed with existing port settings
Or "disable" to disable the port for Boot Interface Management
Or "edit" to change the port settings:
New Settings
------------
primary-image tftp://10.10.10.1/both.tim
#uplinkA Port Settings:
uplinkA-port 1/1/13
uplinkA-address 10.10.10.2/24
uplinkA-vlan null
#uplinkB Port Settings:
uplinkB-port 1/1/2
uplinkB-address 0
uplinkB-vlan 0
#System Settings:
wait 3
persist off
console-speed 115200
Do you want to save the new settings? (yes/no): y
Successfully saved the new settings in cf1:/bof.cfg

En este paso el equipo 7210 SAS-E y el porttil ya estn configurados, el quipo 7210 SAS-E
iniciara por el bof y en este paso el equipo debe cargar automticamente la versin de timos
que esta alojada en el FTP o TFTP.
Configuring Network with uplinkA Port Setting.....
Alcatel-Lucent 7210 - R1.0 Configuration Note
All Rights Reserved Alcatel-Lucent 2008 7
No existing config file URL
Primary image location: tftp://10.10.10.1/both.tim
Initializing uplinkA port using IP addr 10.10.10.2.
Loading image tftp://10.10.10.1/both.tim
Version B-1.0.R3, Sun Mar 22 15:06:25 IST 2009 by builder in
/builder/ws/1.0/sultan/panos/main
text:(27025870-->84606180) + data:(1922158-->10725476)
Executing TiMOS image at 0x100000
Total Memory: 512MB Chassis Type: sas Card Type: badami_7210
TiMOS-B-1.0.R3 both/mpc ALCATEL SAS-E 7210 Copyright (c) 2000-2009
Alcatel-Lucent.
All rights reserved. All use subject to applicable license
agreements.
Built on Sun Mar 22 15:06:25 IST 2009 by builder in
/builder/ws/1.0/sultan/panos/main
___ ___ ___ ___
/\ \ /\__\ /\ \ /\ \
\:\ \ ___ /::| | /::\ \ /::\ \
\:\ \ /\__\ /:|:| | /:/\:\ \ /:/\ \ \
/::\ \ _\/__/ /:/|:|__|__ /:/ \:\ \ _\:\~\ \ \
/:/\:\__\ /\__\ /:/ |::::\__\ /:/__/ \:\__\ /\ \:\ \ \__\
/:/ \/__/ /:/ / \/__/~~/:/ / \:\ \ /:/ / \:\ \:\ \/__/
/:/ / /:/ / /:/ / \:\ /:/ / \:\ \:\__\
\/__/ \/__/ /:/ / \:\/:/ / \:\/:/ /
/:/ / \::/ / \::/ /
\/__/ \/__/ \/__/
Time from clock is SUN JUL 08 00:41:34 2001 UTC
CRITICAL: CLI #1001 Cannot locate the configuration file -
Using default configuration values.
MAJOR: CLI #1008 The SNMP daemon is disabled. To enable SNMP,
execute the command 'config>system>snmp no shutdown'.
TiMOS-B-1.0.R3 both/mpc ALCATEL SAS-E 7210 Copyright (c) 2000-2009
Alcatel-Lucent.
All rights reserved. All use subject to applicable license
agreements.
Built on Sun Mar 22 15:06:25 IST 2009 by builder in
/builder/ws/1.0/sultan/panos/main
Login:
Login:

 Cuando se solicite el login se debe digitar admin y luego se pedir al password,


se debe digitar admin.

Login: admin
Password: admin

A:NA00001223M4#
A:NA00001223M4#
A:NA00001223M4#
 En este paso ya se tiene acceso al equipo y la versin de timos esta cargada en
el equipo 7210 SAS-E de manera temporal, a continuacin se debe ejecutar el
siguiente procedimiento para bajar la versin de timos y que esta quede en la
memoria CF1 del equipo 7210 SAS-E, esto permitir que ya no se requiera el
servidor FTP o TFTP para iniciar el equipo cuando se apague o se reinicie.

3.2. Carga de versin de timos al equipo.

 Se procede a configurar un servicio IES para lograr conectividad del porttil al


equipo.

Login: admin
Password: admin

A:NA00001223M4#
A:NA00001223M4#
A:NA00001223M4#
A:NA00001223M4#

 Copiar y pegar el la consola del equipo el siguiente script

configure port 1/1/24


shutdown
ethernet mode access uplink
no shutdown
exit all
configure service ies 1000 customer 1 create
no shutdown
interface prueba create
no shutdown
address 192.168.1.5/24
sap 1/1/24:0.* create
exit
exit all
configure system security
telnet-server
ftp-server
user prueba
password prueba
access console ftp snmp
exit all
admin save cf1:\config.cfg

 Para verificar conectividad se debe conectar el porttil al puerto 1/1/1 del equipo
y luego realizar un ping desde el equipo 7210 SAS-E al porttil, ping 192.168.1.1
 Abrir una ventana de DOS y hacer un ftp a la direccin 192.168.1.15 luego de
tener acceso se digita hash se da enter y luego bin y se da enter, luego
put bot.tim

 Luego, copiar y pegar el siguiente script, este crea una carpeta en la memoria
cf1 del equipo, esta carpeta tendr el nombre de versin de timos (para este
caso 7210-SAS-E-TiMOS-2.0.R2). La carpeta se utilizar para alojar el archivo
both.tim, la carpeta se crea desde la consola (conexin serial) pegando el
siguiente script:

file
md 7210-SAS-E-TiMOS-2.0.R2
cd 7210-SAS-E-TiMOS-2.0.R2
exit
 Posteriormente desde la ventana de DOS accesar al equipo 7210 SAS-E
mediante ftp, luego de tener acceso se digita hash se da enter y luego bin y se
da enter, luego se accede la carpeta creada anteriormente.
 Luego se procede a pasar el archivo both.tim al equipo digitando el comando
put both.tim.
 Se modifica el bof desde lnea de comando (puerto serial) del equipo con el
siguiente script.

bof
primary-image cf1:\7210-SAS-E-TiMOS-2.0.R2\both.tim
primary-config cf1:\config.cfg
save
exit all
bof save
admin save

 Por ultimo desconectar el patchcord del puerto 1/1/24 y reiniciar el equipo


mediante el comando admin reboot