Académique Documents
Professionnel Documents
Culture Documents
Summary of cost for Civil, plumbing, electrical & fire fighting works
Sl. No. Description DSR Amount in Rs. Non-DSR Amount in Rs.
9 Total Estmated cost of DSR with updated cost index & non-DSR items #REF!
13 Total #REF!
ABSTRACT OF COST - CIVIL WORKS :
TOTAL: #REF!
No.
Items Description of item NO. L B H Deduct Qnty. Net quantity
1 2.6
Earth work in excavation by
mechanical means (Hydraulic
excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in
width as well as 10 sqm on plan)
including getting out and disposal of
excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by
Engineer-in-charge.
2.6.1 All kinds of soil F1 4 3.2 3 1.5 57.6
(@) 146.5 F2 3 2.8 3 1.5 37.8
F3 2 2.5 2.8 1.5 21
F4 1 1.5 1.5 1.5 3.375
CF1 4 2.90 4.90 1.50 85.26
CF2 3 4.50 2.70 1.50 54.675
CF3 1 4.90 2.90 1.50 21.315
CF4 1 4.50 4.50 1.50 30.375
TOTAL 253.8 254
2.81
14
7.23 8
2 41 0.23 18.86
4 6.32 0.12 3.0336
21.89 22 SQM
3 4.12 Extra for providing and mixing water
proofing material in cement concrete
work in doses by weight of cement as per
manufacturer's specification.
2 36.71 1 73.42
2 9.22 1 18.44
91.86 92.00 sqm
R CC WORK
106.20
107.00 Cum
300*450 Columns for all three floors 20 0.30 0.45 9.90 26.73
d 5.19.20
Suspended floors, roofs, landings,
balconies and access platform. with water
proof ply 12 mm thick
3 35.21 9.22 973.91
998.79
say 1000Sqm
3.3 5.22.6
Steel reinforcement for R.C.C. work
including straightening, cutting,
bending, placing in position and binding all
complete upto plinth level. )
Thermo-Mechanically Treated bars 107+250=357 cum @140 Kg/cum 49980
Say 50000 Kg
Providing Murga Jali at the corners of the
wall and columns by providing fastners in
the columns at a distance of not more 0.50m
and providing M S nails of not less than 80
mm long in brick masonary walls at an
equidistance or as directed by the Engineer
in Charge complete.
3.4
6.13.2
5.3 9.11
300X16 8 8 8 No
3 9.1
5.6 9.100.1 Providing and fixing aluminium handles, ISI
marked, anodised (anodic
coating not less than grade AC 10 as per
IS : 1868) transparent or dyed
to required colour or shade, with necessary
screws etc. complete
a 125 32 32 No
b 100 4
6.2 11.27
2 11.39
ROOFONG
1
P/F 1.0 MM THK METAL DECKING SHEET 1 7.43 16.6 123.34 125M2
2 12.45 side inclusive) as per IS : 277 and
consisting of angle cleats of size
25 mm wide x 1.6 mm thick with flanges of
27 mm and 37mm, at
1200 mm centre to centre, one flange fixed
to the ceiling with dash
fastener 12.5 mm dia x 50mm long with
6mm dia bolts, other flange
of cleat fixed to the angle hangers of
25x10x0.50 mm of required
length with nuts & bolts of required size and
other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running
at the spacing of 1200 mm centre to centre,
to which the ceiling
section 0.5 mm thick bottom wedge of 80
mm with tapered flanges
of 26 mm each having lips of 10.5 mm, at
450 mm centre to centre,
shall be fixed in a direction perpendicular to
G.I. intermediate channel
with connecting clips made out of 2.64 mm
dia x 230 mm long G.I.
wire at every junction, including fixing
perimeter channels 0.5 mm
thick 27 mm high having flanges of 20 mm
and 30 mm long, the
perimeter of ceiling fixed to wall/partition
with the help of rawl plugs
at 450 mm centre, with 25mm long dry wall
screws @ 230 mm
interval, including fixing of gypsum board to
ceiling section and
perimeter channel with the help of dry wall
screws of size 3.5 x 25
mm at 230 mm c/c, including jointing and
finishing to a flush finish
of tapered and square edges of the board
with recommended jointing
compound , jointing tapes , finishing with
jointing compound in 3
layers covering upto 150 mm on both sides
of joint and two coats of
primer suitable for board, all as per
manufacturer's specification and
also including the cost of making openings
12.45.1 for light fittings, grills,
12.5 mm thick tapered edge gypsum plain
board
conforming to IS: 2095- Part I
1 27.23 12.25 333.57
1 16.805 7.2 120.99
FINESHING
180
-1329.56
1 13.1
13.1.2 12 mm cement plaster of mix
1:6 (1 cement: 6 fine sand) 0.45 1330 598.5 600M2
2 13.2
15 mm cement plaster on the rough side of
single or half brick wall
13.2.2 of mix :
1:6 (1 cement: 6 fine sand) 0.55 1330 731.5 735M2
3 13.41
Distempering with oil bound washable
distemper of approved brand
and manufacture to give an even shade :
13.82
13.82.2 0.75
0.75 (600+735) 1335 1001.25 1005M2
4 13.46
13.46.1 Finishing walls with Acrylic ,Smooth exterior paint of required shade
2.10
6 0.75 9.45
1.80
14 2.00 50.4
2 1.5 1.80 5.4
5 0.90 0.60 2.7
92.94
8KG
743.52 745 KG
1 21.1
21.1.1 Providing and fixing aluminium work for
doors, windows, ventilators
and partitions with extruded built up
standard tubular sections/
appropriate Z sections and other sections
of approved make
conforming to IS: 733 and IS: 1285, fixing
with dash fasteners of
required dia and size, including necessary
filling up the gaps at
junctions, i.e. at top, bottom and sides with
required EPDM rubber/
neoprene gasket etc. Aluminium sections
shall be smooth, rust
free, straight, mitred and jointed
mechanically wherever required
including cleat angle, Aluminium snap
beading for glazing / paneling,
C.P. brass / stainless steel screws, all
complete as per architectural
drawings and the directions of Engineer-in-
charge. (Glazing, paneling
and dash fasteners to be paid for
separately) :
A)
21.1.1.1 For fixed portion
Anodised aluminium (anodised transparent
or dyed to
required shade according to IS: 1868,
Minimum anodic
coating of grade AC 15) 0.55 745 409.75 410KG
B) 21.1.2
3 22.1
P/F GLAZING 0.8 60.00 48 50M2
4 21.4
Providing and fixing double action hydraulic
floor spring of approved
brand and manufacture conforming to IS :
6315, having brand logo
embossed on the body / plate with double
spring mechanism and
door weight upto 125 kg, for doors,
including cost of cutting floors,
embedding in floors as required and making
good the same matching
to the existing floor finishing and cover
plates with brass pivot and
single piece M.S. sheet outer box with slide
plate etc. complete as
per the direction of Engineer-in-charge.
3E 6 6NO
5 21.13
Providing and fixing 100mm brass locks
(best make of approved
quality) for aluminium doors including
necessary cutting and making
good etc. complete
10E 10 10 NO
1 22.6