Vous êtes sur la page 1sur 3

Poultry House Controllers

Your Technology Partner

Easy Access to Control Process for:


Layer; Egg production
Broiler; Chicken productions for excellent quality meat
Breeder; Mother and father growth for broiler and layer

Features:
- Two zones house temperature measurement and control,
- Heating, cooling and humidity control,
- Feeding control from age curves, feeding storage silo weight measurement and control,
- Lighting control from age curves, lighting control with analog output,
- Outside temperature measurement and intelligent influence on controls,
- Outside temperature min. and max. data daily recording and logging,
- Water, Electricity, Food consumption measurement, daily data recording and logging,
- Ventilation control with 8 stages relay outputs and analog output,
- Shutter open / close control with relay outputs and analog output,
- Animal weight measurement from up to 3 scales placed in house,
- Daily animal weight recording and logging for 3 scales.

Breeder
Mother and father growth for broiler and layer Layer
Egg production

Broiler
Chicken productions for excellent quality meat

36
Poultry House Controllers
Your Technology Partner

Functions EPC-1 EPC-3 EPC-4


Age CURVE + + +
RS-232 / RS-485 Serial Communication, ModBus RTU protocol + + +
Pt-100 input -1, Room Temperature Measurement + + +
Pt-100 input -2, Room Temperature Measurement + + +
Pt-100 input -3, Outside Temperature Measurement + + +
8 Relay Outputs for Fans + + +
0-10 V Analog Output for Fans + + +
Heater-1 and Heater-2 Relay Outputs + + +
Cooling Relay Output + + +
Alarm Relay Output and 2 Alarm Signal Inputs + + +
Shutter Open/Close Relay outputs + + +
0-10V Analog Output for Shutter Control + + +
Humidity Control Relay Output & %RH measurement + + +
Feeding Relay Output & Feeding weight measument + +
0-10V Analog Output for Lighting control + +
Water & Electricity Consumption measurement input (pulse) & Log +
Weight-1, Weight-2, Weight-3 measurement inputs & weight logging +
Feeding Consumption log + +
Lighting curves & Lighting Relay Output + +
Shutter Feedback EPC-1,3,4 - A Series

+ - + - + - + - + - + -

Shutter Electricity
Alarm 1

Neg Pres

Feeding

Water
Consump.
2 x Pt-100 Pt-100 0-10Vdc 0-10Vdc 3 x 0-10Vdc
inputs for input for input for input for inputs for Feedback
Room Outside Relative Feeding Weight
temperature temperature Humidity EPC-1A EPC-1
EPC-3A EPC-3 EPC-3 EPC-4
EPC-1, EPC-3, EPC-4 EPC-3, EPC-4 EPC-4 EPC-4A EPC-4 EPC-4

Analogue inputs Digital inputs


Communication

RS-232 ModBus RTU


for PC communication

Analogue Outputs RS-485 communication


Relay Outputs
0-10Vdc for Expansion Board

EPC-1 EPC-3 EPC-1, EPC-3, EPC-4 EPC-3


EPC-3 EPC-4 EPC-4
Heater-1

Heater-2

Humidity

EPC-4 Shutter
Feeding
Lighting
Alarm-1
Cooling
Lighting

8 x Relay outputs
Shutter

Close
Open
Fans

for Fan Control 8 - 32Vdc


Supply Voltage

37
Poultry House Controllers
Your Technology Partner

What is a curve:
Optimal temperature, ventilation, humidity, feeding and lighting values change day by day. EPC offer automatically adjustment
of optimal values for depend on entered parameters which are in CURVE SETUP PAGES. This function is called 'curve.

Step10 Feeding (kg)


Step9
Step8
Step7
Step6
Step5 Humidity (%)
Step4 Temperature (C)
Step3 Ventilation max.
Step2 (%)
Ventilation min. (%)
Step1
Day
Step1 Day=1

Day=12
Step3 Day=10

Step4 Day=14

Step5 Day=20

Step6 Day=30

Step7 Day=32

Step8 Day=36
Step2 Day=8

Step10 Day=40

Day=999
Day=0

Step9 Day=38

38