Vous êtes sur la page 1sur 44

Automatic Water Quality Monitoring

System

2012. 03.

1
Introduction

Composition

Application

Overview of Company

2
Introduction

3
Objectives of Environmental Monitoring

1. Assessment of
Environmental
Quality

2. Pollution Source Integrated


Environmental 3. Forecast and
Control and Monitoring Early Warning
Load Estimation System

4. Performance
Evaluation

4
Integrated Environmental Monitoring System

5
Components

6
Water Monitoring Parameters

DO, turbidity, chlorophyll


Water temp., conductivity, pH
Ammonia, nitrate, nitrite, phosphate, silicate
Water level, flow speed : flow rate
Total nitrogen, total phosphorus
TOC or DOC, COD
Toxicity
Volatile organic carbons
Trace metals
Automated sampling of water samples for
laboratory analyses : BOD, toxic substances, etc. 7
Surface Water Monitoring Stations
Monitoring key water quality parameters on real-time basis for
watershed management
On-site and on-line monitoring at rivers, lakes and reservoirs
Providing useful information for implementing action plans to
improve water quality

8
Sampling Facilities

Pump

9
Packaged Monitoring System
COD

TN

TP

NH4-N

(NO3+NO2)-N
NO2-N
PO4-P
Auto Filter

Auto Sampler

Temperature Chlrophyll
pH Turbidity
DO Conductivity
10
Sensors and Automatic Analyzers
RS-232C
COD

TN

TP

Ammonia
Conductivity

Multiple serial ports


Phosphate
Water Temperature

Nitrate pH

DO
Nitrite

Turbidity

Automatic sampler Datalogger

Chlorophyll

11
Communication Network

12
Data and Information Services

NIER Academia

Report approval
Ministry of Env.
Data Opening system (Watershed & TMDL Division)

Report submission
Small stream
AWQM station Automated Water Quality Monitoring System
(new)
Environmental
Alarm Data
QA/QC Management
Control Management Operation & Cooperation
management
AWQM
(existing)

Point Pollution Local Watershed Ministry Of


sources source DB Government Env. Office Env.
(TMS) (NIER)

13
Operation and Management

Preventative maintenance plans


Emergency repair service
Quarterly audits
Proficiency testing (PT)
Standard Operating Procedures (SOPs)
Quality Assurance Project Plans (QAPP)
Data validation methods
Education and training for operators

14
Application

15
System Components
Automated water quality monitoring system
Surface water monitoring stations
Groundwater monitoring stations
Tap water monitoring stations
Marine environmental monitoring stations
End-of-pipe wastewater monitoring stations
Telemetry and information system
Wireless and wired communication
Data processing and QA/QC
Information management

16
National Automated Water Quality
Monitoring Network
Korea Ministry of Environment
operates total 56 automated water
quality monitoring stations in rivers
and lakes in Korea

17
Water Quality Information System

18
National Marine Environmental
Monitoring System
Ministry of Land, Transport and Maritime Affairs operates 9 automated
water quality monitoring stations in coastal area and plans to install
additional 5 stations in 2011.

19
Automated Water Quality Monitoring
System in Gyeonggi Province

Lake Paldang Watershed Anyang Stream Watershed

6 Stations 1 Station
20
End-of-pipe Wastewater Monitoring
Discharge Capacity Total 2008 2009 Installation
Section
(ton/day) 568 344 224 Deadline
Subtotal 311 176 135
Public sewage Over 100,000 49 49 - 08.5.19
treatment
plants 10,000 ~ 100,000 127 127 - 08.11.19
2,000 ~ 10,000 135 - 135 09.11.19

Public waste Subtotal 51 51 -


water Over 10,000 26 26 - 08.5.19
treatment
plants 700 ~ 10,000 25 25 - 08.11.19
Subtotal 206 117 89
Industrial Class 1 117 117 - 08.9.30
facilities
Class 2 89 - 89 09.9.30
Class 3 industrial facilities should install equipments in 9 month after violating discharge limits
from October 2010
21
Automatic Analysers and Sampler

22
End-of-pipe Monitoring Station

23
End-of-pipe Monitoring Station

24
Data and Information Services

25
Central Monitoring Station

26
Obtaining Pollution Loads Information

Loads (g/sec)
Precipitation (mm/day)

27
Obtaining Pollution Loads Information

(g/sec)
(g/sec)
2008 2009
28
Obtaining Pollution Loads Information

2008 2009
29
Estimation of Pollution Loads

30
Nonpoint Source Control

31
Nonpoint Source Control

32
Fish Killed at Anyang Stream

33
Forecasting Fish Death

Fish Kill

34
Forecasting Fish Death

35
Forecasting Fish Death

Fish Kill 36
Eutrophication of Lake Paldang
()

37
Overview of Company

38
Centennial Technology
Established in 2000 in Ansan, Korea as a spinout venture
company from The Korean Ocean R&D Institute (KORDI)
Manufacturing water monitoring and treatment
equipment/systems using patented technologies

39
On-line Chemical Analyzers
RoboChem is a on-line chemical analyzer designed for
monitoring water quality of water from industrial processes
Application: environmental monitoring, industrial process
control, and monitoring dischargers

40
Packaged Monitoring Station
Compact, pre-assembled, and self-contained monitoring system
which can be transported to a project site
Able to monitor many key water quality variables for water and
wastewater applications

41
Packaged Wastewater Treatment Plant
AquatiCube: a packaged plant for small community having
population of 2000 or less
Minimize on-site construction and installation costs and ensure
specific performance and compliance requirements

42
Nonpoint Source Pollution Control
Providing diverse solutions for BMPs installations such as
recirculated vertical flow subsurface wetland, modular water
oxidation with artificial grass, infiltration tank and swales
Cooperating with Atlantis Water Management(Australia) and
HydroCore.

43
Thank you !