Vous êtes sur la page 1sur 6

Testing Script

UNISUP

Prevent Changes of Measuring Position

370826118.doc 1/9 Last updated: 29/07/2004 02:21:00 PM


Prevent Changes of Measuring Position
1. Contents
1. Contents............................................................................................................................................................... 2
2. Overview............................................................................................................................................................... 3
3. Procedure............................................................................................................................................................. 0
1.1 Create Measuring Point................................................................................................................................. 0
1.2 Change Measuring Position........................................................................................................................... 5
4. Error Messages.................................................................................................................................................... 6

370826118.doc 2/9
Prevent Changes of Measuring Position

2. Overview
For Inspection, Measuring Position in SAP is used to identify physical fixed point where the Inspection
shall take place. Inspection Scope and isometric drawing used this information as reference. Therefore,
once the Measuring Position is defined and the Measuring Point is created in SAP, this information must
remain the same (no change applicable).

SAP Login
System/Client : RD6/035
User-ID : irmansyah
Language : EN

Testing
Tested by : Prima Irmansyah
Date : 05th July 2004

370826118.doc 3/9
Testing Script

3. Procedure
1.1 Create Measuring Point
SAP Object
Functional Location : F15/F15A /GAS/TRANS/10-NG-91-010-F67S

Note: There are many ways in creating Meas. Point, but only creation with IK04 that will enable cascading of characteristic values.

No. Function T-Code Input Expected Result Actual Result Remark


Mandatory Fields : Meas.
Category : N Position, Description and
Characteristic/Code Group
Measuring Position : 1000
System forced to entry all
1. Create Measuring Point IK04 Description : Point 1000 Created with IK04 Meas Point is created
lines of Meas Point within
NOT OK
Characteristic : THKI
one screen
Code Group : Status Meas Point created without
mandatory Auth Grp
Click on New Entries Mandatory Fields : Meas.
Position, Description and
Category : N Characteristic/Code Group
System forced to entry all
2. Create Measuring Point IK05 Measuring Position : 1000 Meas Point is created NOT OK
lines of Meas Point within
Description : Point 1000 Created with IK05
one screen
Characteristic : THKI
Meas Point created without
Code Group : Status
mandatory Auth Grp
3. Create Measuring Point IL02 Category : N Meas Point is created Mandatory Fields : Meas. NOT OK
Measuring Position : 1000 Position, Description and
Description : Point 1000 Created with IL02 Characteristic/Code Group
Characteristic : THKI System forced to entry all
Code Group : Status lines of Meas Point within
one screen Meas Point
created without mandatory
370826118.doc 4/9 Last updated: 29/07/2004 02:21:00 PM
Prevent Changes of Measuring Position
No. Function T-Code Input Expected Result Actual Result Remark
Auth Grp
Category : N Mandatory Fields : Meas.
Measuring Position : 1000 Position, Description,
Description : Point 1000 Created with IK01 Characteristic/Code Group
4. Create Measuring Point IK01 Meas Point is created OK
Characteristic : THKI and Auth. Grou^p
Code Group : Status Meas Point is successfully
created

1.2 Change Measuring Position


Note: There are many ways in creating Meas. Point, but only creation with IK04 that will enable cascading of characteristic values.

No. Function T-Code Input Expected Result Actual Result Remark


Select Meas Point
Measuring Position : 1000
Change Measuring Change for Meas. Meas. Position is still able to be
1. Position
IK04 Description : Point 1000 Created
Position is prevented. changed.
OK
with IK04
Measuring Position change to : 9999
Select Meas Point
Measuring Position : 1000
Change Measuring Change for Meas. Meas. Position is still able to be
2. IK05 Description : Point 1000 Created OK
Position Position is prevented. changed.
with IK05
Measuring Position change to : 9999
Select Meas Point
Measuring Position : 1000
Change Measuring Change for Meas. Meas. Position is still able to be
3. IL02 Description : Point 1000 Created OK
Position Position is prevented. changed.
with IL02
Measuring Position change to : 9999
Select Meas Point
Measuring Position : 1000
Change Measuring Change for Meas. Meas. Position is still able to be
4. IK02 Description : Point 1000 Created OK
Position Position is prevented. changed.
with IK02
Measuring Position change to : 9999

370826118.doc 5/9 Last updated: 29/07/2004 02:21:00 PM


Prevent Changes of Measuring Position
4. Error Messages
All lines in the screen are marked as mandatory

370826118.doc 6/9 Last updated: 29/07/2004 02:21:00 PM

Vous aimerez peut-être aussi