Vous êtes sur la page 1sur 1

1 2 3 4 5 6 7 8

To Comply with EMC regulations Flying Lead is screened. Screening is connected externally to the Transducer body to form an
A
overall shield. Transducer body must be earthed directly or through cable screening A

Overall Length = 4586 300


32 24 37.2 Stroke = 4500 200 (30.8) 30

4 Two Wire Current Output (mA) 20


'T' Style Electrical Approx 5mm overlap
Termination
B 10 Metre Long 4.4 22AWG typical both ends B
PVC Screened Cable
Maximum pressure for sensor is 380 bar.

N S N S

15.88
Magnet Position Magnet Position
C
Zero Stroke Full Stroke C

O-Ring NOTE: Transducer to be housed in a magnetic material.


B/U Ring
Wiring Details:-

White - Input (11 to 28V)


Black - Signal (4 to 20mA) North pole of magnet to be indicated by a
20.40
white mark and must be orientated
1.44 16.50 to face the head of the transducer.
1.30 16.40
D 44 D

10.50
1.50 x 45
M5

PROVISIONAL
24.93
24.80

24.10
24.00
25.03
25.01

18
18

PRODUCTION NOTES MATERIAL & FINISH:


UNLESS OTHERWISE STATED
REMOVE ALL SHARP EDGES
MACHINED SURFACE TEXTURE TO BE 1.6um RA
ROTA Engineering Ltd
TOLERANCE ON MACHINED DIMENSIONS 0.25mm
TOLERANCE ON NON-MACHINED DIMENSIONS 0.75mm
Wellington Street, Bury, Manchester, UK, BL8 2BD
TOLERANCES ON ANGLES 2 DEGREES Tel: +44 (0)161 764 0424 Fax: +44(0)161 762 9729
ALL DIMENSIONS IN MILLIMETRES email: info@rota-eng.com web: www.rota-eng.com
3 x 15 NAME DATE TITLE:

LJS 4500 M 0.3T T10 3787


DRAWN A. Granadero 19.08.2015
End Cap Magnet Housing CHECKED

Machining Detail
APPROVED
F
Machining Detail THE COPYRIGHT IN THIS DRAWING IS VESTED
IN ROTA ENGINEERING LTD., WELLINGTON STREET,
DWG NO. REVISION

BURY, MANCHESTER, U.K. REPRODUCTION IN


SOLE OR IN PART OR MANUFACTURE FROM THIS
DRAWING IS NOT PERMITTED EXCEPT WITH PRIOR
LJ 3787 0/1
1 2 3 4 WRITTEN CONSENT OF ROTA ENGINEERING LTD. SCALE:1:5 DO NOT SCALE DRAWING SHEET 1 OF 1