Académique Documents
Professionnel Documents
Culture Documents
UNISUP
370828008.doc 2/9
Classification Cascading and Inspection Points Creation
2. Overview
Inspection Classification Cascading provides functionality to inherit characteristics values of Functional Location
to its Measuring Points (Inspection Points). And this is supposed to be working with transactions
IK04 Create/Change Measuring Point,
IK05 Change Measuring Point,
IL02 Change Functional Location & Measuring Point, and
YIK04 Upload Measuring Point.
SAP Login
System/Client : R3M/035
User-ID : irmansyahp
Language : EN
Testing
Tested by : Prima Irmansyah
Date : Fri, 2nd July 2004
370828008.doc 3/9
Testing Script
3. Procedure
1.1 List of Functional Location
No. Function Transaction & Steps Input Expected Result Actual Result Remark
IL02
Classification of FL : PIPING01
1. Functional Location
Assign class for
Class : PIPE-PIP
OK
PIPING01
2. Fill-in Characteristics IL02 Corrosion Allowance (Ca) : 2,5 mm OK
Values of Functional Assign characteristics Manufacturer's tolerance (C1) : 12,5%
Location values for PIPING01 Allowable Stress : 7,30 Pa
Design Pressure : 11,0 bar
Design Temperature : 125 C
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Meas. Position : 1010 Dependencies
Chars Values changes : characteristics
IK04 Nominal Diameter : 15 Dependencies are calculated
Change Measuring Point Change values of non- Nominal Thickness : 4 mm characteristics are After SAVED char
1. with IK04 calculated
OK
inheritance chars of Alarm Thickness (Us1) : 3 mm value for
Meas. Point Alarm Thickness (Us2) : 4 mm Material & Grade
Ins. Technique : INT-US Manual- Pipe is
Comp Wve-Scan inherited
2. Change Measuring Point IK04 Meas. Position : 1010 After SAVED char OK
with IK04 Change values of Chars Values changes : values are still kept
inheritance chars of Corrosion Allowance (Ca) : 2 mm as changes made
Meas. Point Manufacturers tolerance (C1) : 9%
370828008.doc 5/9 Last updated: 16/07/2004 10:55:00 AM
Classification Cascading and Inspection Points Creation
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Allowable Stress : 5 Pa
Design Pressure : 10 bar
Design Temperature : 150 C
Material & Grade Pipe : API 5L
GRADE ABC
IK04 Meas. Position : 1010
Changes prevented.
Change Measuring Point Change values of Chars Values changes : System prevents the
3. System kept the OK
with IK04 dependencies chars of Alarm thickness (Tman-C1-Ca) changes
calculated values.
Meas. Point Alarm thickness (Pd)
On SAVE >
Message no.
C1 821 appears.
Corrosion Allowance (Ca) : 2,5 mm Changes are
Manufacturers tolerance (C1) : 12,5% saved.
IL02
Change Characteristics Allowable Stress : 7,30 Pa Changes of Char Changes are
Open PIPING01
4. Values of Functional Design Pressure : 11,0 bar Values inherited to inherited to Meas. NOT OK
Change characteristic
Location Design Temperature : 125 C Meas. Points Points except
values of PIPING01
Material & Grade Pipe : API 5L Material & Grade
GRADE B SEAMLESS Pipe. This
value is
disappeared from
all Meas. Points
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Meas. Position : 1020 Dependencies
Chars Values changes : characteristics
IK05 Nominal Diameter : 15 Dependencies are calculated
Change Measuring Point Change values of non- Nominal Thickness : 4 mm characteristics are After SAVED char
1. with IK05 calculated
NOT OK
inheritance chars of Alarm Thickness (Us1) : 3 mm value for
Meas. Point Alarm Thickness (Us2) : 4 mm Material & Grade
Ins. Technique : INT-US Manual- Pipe still
Comp Wve-Scan missing
2. Change Measuring Point IK05 Meas. Position : 1020 After SAVED char OK
with IK05 Change values of Chars Values changes : values are still kept
370828008.doc 6/9 Last updated: 16/07/2004 10:55:00 AM
Classification Cascading and Inspection Points Creation
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Corrosion Allowance (Ca) : 2 mm
Manufacturer's tolerance (C1) : 9%
Allowable Stress : 5 Pa
inheritance chars of
Design Pressure : 10 bar as changes made
Meas. Point
Design Temperature : 150 C
Material & Grade Pipe : API 5L
GRADE ABC
IK05 Meas. Position : 1020
Changes prevented.
Change Measuring Point Change values of Chars Values changes : System prevents the
3. System kept the OK
with IK05 dependencies chars of Alarm thickness (Tman-C1-Ca) changes
calculated values.
Meas. Point Alarm thickness (Pd)
On SAVE >
Corrosion Allowance (Ca) : 5 mm Message no.
Manufacturer's tolerance (C1) : 25% C1 821 appears.
IL02 Changes are
Change Characteristics Allowable Stress : 15 Pa Changes of Char
Open PIPING01 saved.
4. Values of Functional Design Pressure : 22 bar Values inherited to NOT OK
Change characteristic Changes are
Location Design Temperature : 200 C Meas. Points
values of PIPING01 inherited to Meas.
Material & Grade Pipe : API 5L Points except
GRADE A Material & Grade
Pipe
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Meas. Position : 1030 Dependencies
Chars Values changes : characteristics
IL02 Nominal Diameter : 15 Dependencies are calculated
Change Measuring Point Change values of non- Nominal Thickness : 10 mm characteristics are On SAVE > ALMOST
1. with IL02 calculated OK
inheritance chars of Alarm Thickness (Us1) : 3 mm Message no. MC
Meas. Point Alarm Thickness (Us2) : 4 mm 601 appears.
Ins. Technique : INT-US Manual- Changes are
Comp Wve-Scan saved.
2. Change Measuring Point IL02 Meas. Position : 1030 On SAVE > ALMOST
with IL02 Change values of Chars Values changes : Message no. MC OK
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Meas. Position : 1010
Chars Values changes : Dependencies
characteristics
IK02 Nominal Diameter : 5 Dependencies
are calculated
Change Measuring Point Change values of non- Nominal Thickness : 6 mm characteristics are
1. with IK02 calculated
After SAVED char OK
inheritance chars of Alarm Thickness (Us1) : 5 mm
values are still
Meas. Point Alarm Thickness (Us2) : 5 mm kept as changes
Ins. Technique : PT WITH made
ACOUSTIC EMISSION_0_00
2. Change Measuring Point IK02 Meas. Position : 1010 After SAVED char OK
with IK02 Change values of Chars Values changes : values are still kept
as changes made
370828008.doc 8/9 Last updated: 16/07/2004 10:55:00 AM
Classification Cascading and Inspection Points Creation
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Corrosion Allowance (Ca) : 5 mm
Manufacturer's tolerance (C1) : 5%
Allowable Stress : 5 Pa
inheritance chars of
Design Pressure : 5 bar
Meas. Point
Design Temperature : 150 C
Material & Grade Pipe : API 5L
GRADE A5
IK02 Meas. Position : 1010
Changes prevented.
Change Measuring Point Change values of Chars Values changes : System prevents the
3. System kept the OK
with IK02 dependencies chars of Alarm thickness (Tman-C1-Ca) changes
calculated values.
Meas. Point Alarm thickness (Pd)
On SAVE >
Corrosion Allowance (Ca) : 6 mm Message no.
Manufacturer's tolerance (C1) : 6% C1 821 appears.
IL02 Changes are
Change Characteristics Allowable Stress : 6 Pa
Open PIPING01 saved. ALMOST
4. Values of Functional Design Pressure : 6 bar
Change characteristic Changes are still OK
Location Design Temperature : 160 C
values of PIPING01 inherited to all
Material & Grade Pipe : API 5L Meas. Points
GRADE 60 except Material
& Grade Pipe
No. Function Transaction & Steps Input Expected Result Actual Result Remark
IK04
Open Meas Position
1050
Changes of Char Changes of Char
Change Classification of Removed assigned
1. Meas Point Class, then SAVE
Class : B/IN Values are inherited to Values are inherited OK
Meas. Points to Meas. Points
Open Meas Position
1050 again then assign
new Class on it.
No. Function Transaction & Steps Input Expected Result Actual Result Remark
IL02
Classification of FL : PIPING03
1. Functional Location
Assign class for
Class : Not assigned
OK
PIPING03
FL : PIPING03
Meas. Point Category : N
IK04
Create Measuring Point Meas. Position : 1010 1050
2. Create 5 Meas. Points on OK
with IK04 Char : HGT, PR, THKI
PIPING03
Code Group : STATUS, GEN, COATS
Class : B/EX, S/03, W/03, VIB, COTE
Class : PIPE-PIP
Corrosion Allowance (Ca) : 2,5 mm When class for Funct
IL02
Manufacturer's tolerance (C1) : 12,5% Loc assigned and
Fill-in Characteristics Assign class
Allowable Stress : 7,30 Pa Char Values inherited char values filled-in,
3. Values of Functional Fill-in characteristics OK
Location Design Pressure : 11,0 bar to Meas. Points those are
values for PIPING03
Design Temperature : 125 C successfully inherited
Save to all Meas. Points
Material & Grade Pipe : API 5L
GRADE B SEAMLESS
No. Function Transaction & Steps Input Expected Result Actual Result Remark
FL : VESSEL01
IL02
Classification of Parent Class : VES-DRUM
5. Vessel
Assign class for OK
No Class assigned for VESSEL01-GAS
VESSEL01
and VESSEL01-OIL
IL02 Corrosion Allowance (Ca) : 2,5 mm
Fill-in Characteristics
6. Assign characteristics Design Pressure : 11,0 bar
Values of Parent Vessel
values for VESSEL01 Design Temperature : 125 C
7. Create Measuring Point IK04 FL : VESSEL01 Meas. Points are When assigning NOT OK
with IK04 in Parent Vessel Create 2 Meas. Points on Meas. Point Category : N created with Char class for Meas
VESSEL01 Meas. Position : 1011,1012 Values inherited Points > ABAP
Char : THKI Runtime Error
Code Group : STATUS, GEN Failed to create
370828008.doc 10/9 Last updated: 16/07/2004 10:55:00 AM
Classification Cascading and Inspection Points Creation
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Class : SHEL, DATA Meas. Points
FL : VESSEL01-GAS When assigning
Meas. Point Category : N Meas. Points are class for Meas
Create Measuring Point IK04
Meas. Position : 1021,1022 created with Char Points > ABAP
8. with IK04 in Sub Structure Create 2 Meas. Points on NOT OK
Char : THKI Values inherited from Runtime Error
Vessel VESSEL01-GAS
Code Group : STATUS, GEN Parent Vessel Failed to create
Class : SHEL, DATA Meas. Points
FL : VESSEL01-OIL When assigning
Meas. Point Category : N Meas. Points are class for Meas
Create Measuring Point IK04
Meas. Position : 1031,1032 created with Char Points > ABAP
9. with IK04 in Sub Structure Create 2 Meas. Points on NOT OK
Char : THKI Values inherited from Runtime Error
Vessel VESSEL01-OIL
Code Group : STATUS, GEN Parent Vessel Failed to create
Class : SHEL, DATA Meas. Points
Changes of Char
IL02
Corrosion Allowance (Ca) : 3,5 mm Values inherited to
Change Characteristics Open VESSEL01
10. Design Pressure : 15,0 bar Meas. Points, Not proceed
Values of Parent Vessel Change characteristic
Design Temperature : 100 C including the ones in
values of VESSEL01 Sub-Structures
1.10 Creation of Measuring Points using IK04, Vessel has different classification Case for Vessel (Not done)
Note: This is not a standard procedure to be applied. Purpose of this test is to simulate when by mistakes, sub structure are classified and filled-in with different
values then the parent vessel.
No. Function Transaction & Steps Input Expected Result Actual Result Remark
IL02
Classification of Parent FL : VESSEL02
1. Vessel
Assign class for
Class : VES-DRUM
VESSEL02
IL02 Corrosion Allowance (Ca) : 2,5 mm
Fill-in Characteristics
2. Assign characteristics Design Pressure : 11,0 bar
Values of Parent Vessel
values for VESSEL02 Design Temperature : 125 C
IL02
Classification of Sub FL : VESSEL02
3. Assign different class for
Structure Vessel Class : VES-PIG
VESSEL02-GAS
4. Fill-in Characteristics IL02 Corrosion Allowance (Ca) : 5,5 mm
Values of Sub Structure Assign different Design Pressure : 22,0 bar
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Upload Measuring Points YIK04 File : PIPE_A.TXT Both Options can be OK
1. with YIK04 (A) Using Option 1 used to upload the
Using Option 2 points successfully
Classification of IL02 Class : PIPE-PIP OK
Functional Location Open PIPING02
2.
Assign PIPE-PIP class for
PIPING02
Upload Measuring Points YIK04 File : PIPE_B.TXT Both Options can be OK
3. with YIK04 (B) Using Option 1 used to upload the
Using Option 2 points successfully
Fill-in Characteristics IL02 Corrosion Allowance (Ca) : 2,5 mm Char Values are All char values are OK
Values of Functional Open PIPING02 Manufacturer's tolerance (C1) : 12,5% inherited to Meas. inherited to all
Location Change characteristic Allowable Stress : 7,30 Pa Points existing Meas. Points
4. values of PIPING02 Design Pressure : 11,0 bar (result of upload A
Design Temperature : 125 C and B)
Material & Grade Pipe : API 5L
GRADE B SEAMLESS
Upload Measuring Points YIK04 File : PIPE_C.TXT Char Values are Option 1: NOT OK
with YIK04 Using Option 1 inherited upon creation ABAP Runtime
Using Option 2 of Meas. Points Error > see short
dump
Program stopped
after creating 1st
Meas Point but
not yet assigning
5. its Class.
Option 2:
All Meas Points
uploaded with its
Class and Char
Values.
But, no inherited
values appear.
6. Change Characteristics IL02 Corrosion Allowance (Ca) : 7 mm Changes of Char Changes of Char
1.12 Upload Measuring Points using YIK04 Case for Vessel (Not done)
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Upload Measuring Points YIK04 File
7. with YIK04 (A) Using Option 1
Using Option 2
Classification of IL02 Class :
Functional Location Open VESSEL03
8.
Assign PIPE-PIP class for
PIPING02
Upload Measuring Points YIK04 File :
9. with YIK04 (B) Using Option 1
Using Option 2
Fill-in Characteristics IL02 Corrosion Allowance (Ca) : 2,5 mm Char Values are
Values of Functional Open VESSEL03 Design Pressure : 11,0 bar inherited to Meas.
10. Location Change characteristic Design Temperature : 125 C Points
values of PIPING02
Upload Measuring Points YIK04 File : Char Values are
11. with YIK04 Using Option 1 inherited upon creation
Using Option 2 of Meas. Points
12. Change Characteristics IL02 Corrosion Allowance (Ca) : 7 mm Changes of Char
Values of Functional Open VESSEL03 Design Pressure : 7 bar Values are inherited to
Location Change characteristic Design Temperature : 170 C Meas. Points
1.13 Upload Measuring Points using YIK04 Test uploading 10.000 Measuring Points (Not done)
No. Function Transaction & Steps Input Expected Result Actual Result Remark
Classification of IL02
1. Functional Location
Fill-in Characteristics IL02
2. Values of Functional
Location
Upload Measuring Points YIK04 Meas. Points are
3. with YIK04 created with Char
Values inherited
Change Characteristics IL02 Changes of Char
4. Values of Functional Values are inherited to
Location Meas. Points