Vous êtes sur la page 1sur 3

xc

g Proj: Admin
Ref :
Tel:d Date: 14/08/17
--------------------------------------------------------------------------------------------------------------------------------------------------------------------
Composite beam - plastic moment capacity

Capacity check in accordance with BS5950(3.1):1990

[ L ] Span - 10 m
[ S ] Steel section - 406x178x60 UB
[ p ]Design strength of steel - 355 N/mm2
y

Slab Details
[ Qts ]Slab type - Haunched solid slab
[ D ]Haunch depth - 50 mm
p
[ br ]Breadth of haunch rib - 250 mm
[ D ]Overall depth of slab - 130 mm
s
[ B ]Flange width - 2500 mm
e
[f ]Characteristic cube strength of concrete - 30 N/mm2
cu
Concrete type - Light weight

Shear connector Details


[ dsc ]Diameter - 22 mm
[ hsn ]Nominal height - 100 mm
[ hsw ]In situ height - 95 mm
[ Q ]Characteristic strength - 126 kN
k
[ N ]Numbers per group - 1
g
[sp_l]Longitudinal spacing - 250 mm

= Sqr(275/p )
y
= Sqr(275/355)
= 0.88
M = Z *p
s s y
= 1200*355
= 426000 kNmm
Referring to appendix B.2.1
Resistance of - concrete flange R = 0.45*f *B *(D -D )/1000
c cu e s p
= 0.45*30*2500*(130-50)/1000
= 2700 kN

- steel beam R = A*100*p /1000


s y
= 76.5*100*355/1000
= 2715.75 kN

- steel flange R = B*Tf*p /1000


f y
= 178*12.8*355/1000
= 808.83 kN

- slender web R = 38**wthk*wthk*p /1000


0 y
= 38*0.88*7.9*7.9*355/1000
= 741 kN

- clear web depth R = wdpt*wthk*p /1000


v y
= 360*7.9*355/1000
= 1009.62 kN

- overall web R = R -(2*R )


w s f
= 2715.75-(2*808.83)
= 1098.09 kN

Capacity of shear connector to resist longitudinal shear (for positive moments)


Qp = 0.8*Q
k
= 0.8*126
= 100.8 kN
Reduction in shear connector capacity for light weight concrete
Qp = Qp*0.9
= 100.8*0.9
= 90.72 kN

F is lesser of R & R
p c s
F = 2700 kN
p

Number of shear connectors required


N = INT(F /Qp)
p p
= INT(2700/90.72)
= 29 No.

Number of shear connectors actually provided


N = INT(((SPAN*1000*0.5)/sp_l)*N )
a g
= INT(((10*1000*0.5)/250)*1)
= 20 No.

Resistance of shear connection


R = N *Qp
q a
= 20*90.72
= 1814.4 kN

Degree of shear connection actually provided


DS = N /N
a a p
= 20/29
= 0.69

Minimum degree of shear connection required


DS = 0.4
m

Referring to Appendix B.2.2 & B.2.3

Since R < F only partial shear connection is achieved


q p

when R >= R ie. plastic neutral axis in flange (case 4)


q w

M = ((R *D/2)+R *(D -((R *(D -D ))/(R *2)))-(((R -R )*(R -R )*Tf)/(R *4)))/1000
c s q s q s p c s q s q f
= ((2715.75*406/2)+1814.4*(130-((1814.4*(130-50))/(2700*2)))-(((2715.75-1814.4)*(2715.75-
1814.4)*12.8)/(808.83*4)))/1000
= 735.18 kNm
Plastic moment capacity = 735.18 kNm

Longitudinal slab shear resistance not checked - calculation assumes adequate