ENGINEERED STEAM TRACING SOLUTIONS

STEAM TRACING SYSTEMS EXTEND BEYOND


THE PIPING, VESSELS, AND EQUIPMENT
Steam tracing applications Engineering Services Field Services
Layout circuits Audit/Locate existing circuits
range from freeze protection to Locate supply and return Complete trap data for
maintaining temperatures close to manifolds maintenance and operations
Estimate installed costs
that of the steam itself. Thermon Estimate condensate loads
and operating costs
steam tracing systems have a VisiTrace 3-D design

low installed cost compared to


multiple bare tracers, light tracing
with spacer blocks, or jacketed
systems. Thermonized systems
also provide predictable operation SafeTrace
and maintenance that process ThermoTube

plants demand.

Turnkey Design, supply, install and insulate with Warm Pipe Warranty Guarantee

MANIFOLD TO MANIFOLD
THERMON OFFERS A STEAM TRACING
SOLUTION FOR EVERY APPLICATION

ENGINEERED STEAM
TRACING SYSTEMS PROVIDE
Lower Installed Cost Deliverables Can Include:
Optimized Circuit Lengths Steam Tracing ISO Drawings
Fewer Steam Traps with Manifold Locations
Manifolds Locations Optimized Steam Circuit Schedules with

plus+ Optimal Performance Manifolds and Traps Identified


More Accurate Temperatures Detailed Installation Instructions
Reduced Summer/Winter
Temperature Swings

plus+ Lower Operating Costs


No Overheating - By Design
Reduced Steam Consumption

plus+ Lower Maintenance Costs


Fewer Traps to Replace
Audit and Maintenance Services Available

equals= Lowest Cost of Ownership!


1
Thermonized with
SnapTrace or other
High Heat Delivery

Thermon Heat Transfer


Compounds

Application: Asphalt, Resids, Sulfur

SafeTraceTM BTS
ONE STEAM PRESSURE
Medium Heat Delivery

or Bare Tracing
FOR DIFFERENT PIPE TEMPERATURES
300
(149)
Thermonized System
260
(127)

Application: Fuel Oils, Heavy Grease, Crude


Temperature F (C)
220 Thermon SafeTrace BTS
(104 or Bare Tubing
SafeTraceTM SLS or DLS
for Light Traced Systems
Low Heat Delivery

180
(82)

Thermon SafeTrace SLS


140
(60)

Application: Caustics, Acids, Amines, Thermon SafeTrace DLS


Small Water Lines 100
(38)

60
(16)
0 1 2 3 4 5 6
PIPE TEMPERATURE Time Hours
RANGES WITH A COMMON Heat-up and maintain characteristics for Thermon systems on
STEAM PRESSURE/TEMPERATURE 2 NPT (50mm) lines with 1 (25mm) insulation with 50 psig (3 barg) steam service
(298F/148C)

HIGH MEDIUM
MAINTAIN TEMPERATURES MAINTAIN TEMPERATURES
Thermonized Tracing Thermonized with Thermon SafeTraceTM BTS: 38C to 121C
with Thermon Heat Transfer Compounds SafeTrace Isolated Steam Tracers
Heat Transfer Compounds reduce or eliminate risk of burns.
Consistent Heat Transfer Properties
Insulated pipe Less Than 20% of Cost for Steam Jacketing
approaching temperature Reduce Bare Trace Circuits by 3 Times LOW
of steam/fluid media. or More MAINTAIN TEMPERATURES
SnapTrace Preformed Extrusions Light Tracing alternative
for Fast Installation to spacer blocks
Available in 4 (1.22 m) m lengths SafeTraceTM SLS-IT: 24C to 93C
SafeTrace BTS Significantly Reduces Installation Time SafeTraceTM DLS-IT: 5C to 54C
Bare Tracing. No Surface Preparation Required
For additional information see
Use With Up to 208C (406F) Fluid/Steam
Thermon Form TSP0005.
HT Compounds for Piping, Valves Increase Circuit Lengths
SafeTrace SLS & DLS and Irregular Surfaces Reduce Number of Circuits and Traps
Isolated Tracing for (Maximum temperature ratings shown) Reduce Operating Costs
lowest pipe temperature. T-3: 371C (700F) Installed with Special Adhesive Tape
T-99: 1,000C (1832F)
T-80: 163C (325F)
T-85: 190C (375F)
T-802: 135C (275F) (two part compound)

THERMON The Heat Tracing Specialists 2


MORE ENGINEERED STEAM TRACING SOLUTIONS

TUBETRACE HEATED INSTRUMENT TUBING


Reduces installation time and costs.

Type SP/MP Single/Multiple Process Tubes


Heavy Traced for higher temperature taintenance
The tracer tube is in direct contact with the process tube(s), so process
tube temperatures will be very close to the tracer tube temperature.
Tube Temperature Range:
5C (40F) to 205 C (400F) *

Maximum Exposure: 205C (400F) *

Type SI/MI Single/Multiple Isolated Tubes


Light Traced for freeze protection and lower temperature maintenance.
The tracer tube is insulated from the process tube(s), so process tube
temperatures will be significantly lower than the tracer tube temperature.
Tube Temperature Range:
5C (40F) to 121C (250F)

Maximum Exposure: 205C (400F) *

STEAM SUPPLY/CONDENSATE RETURN


ThermoTube Pre-Insulated Tubing
TubeTrace bundles are also available with Thermon Electrical
Reduces installation time and costs.
Heat Tracing Products (see CLX0025 for more information).
Continuous Temperature Range:
Service to 205C (400F) *

ThermoTube ratings to 593C (1100F) also available *

* Higher tube temperatures are possible with XINS-extra


insulation HT and HTX type designs.

HEETSHEET TANK AND


VESSEL HEATING UNITS
Provides 2 to 3 Times the Heat Transfer of Plate-Type Coils
No Risk of Cross-Contamination with Process
Light-weight Stainless Steel for Easy Installation
Low ProfileOversized Insulation Not Required

For electrically heated tank applications consider FlexiPanel


pad-type heating systems and/or Thermon electric heat
tracing systems (see TMP0025 for more information).