WALKair V2.0
UMN:IMN
A50010-Z3-C100-1-7631
UMN:IMN Installation
WALKair™ V2.0
2 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
Contents
1 Introduction .......................................................................................................... 5
1.1 WALKair System Architecture.............................................................................. 5
1.2 Installation Overview............................................................................................ 6
2 Base Station Installation ...................................................................................... 7
2.1 General ................................................................................................................ 7
2.2 Packing List.......................................................................................................... 7
2.2.1 Items not supplied in Packing List........................................................................ 8
2.2.2 Site Preparation ................................................................................................... 8
2.2.3 Base Station Connectors ..................................................................................... 9
2.2.4 Base Station Cables .......................................................................................... 10
2.3 Base Station Installation Concept ...................................................................... 10
2.4 Installing the Outdoor Equipment....................................................................... 11
2.4.1 General .............................................................................................................. 11
2.4.2 Mounting the RFU on the Pole........................................................................... 11
2.4.3 Mounting the Antenna on the Pole..................................................................... 11
2.4.4 Connecting the RFU to the Antenna .................................................................. 12
2.4.5 Connecting the RFU to the Indoor Equipment ................................................... 13
2.5 Installing the Indoor Equipment ......................................................................... 13
2.5.1 General .............................................................................................................. 13
2.5.2 Base Station BU Interfaces................................................................................ 14
2.5.3 IF Multiplexer Interfaces..................................................................................... 15
2.5.4 Mounting the BU-BSs in Racks.......................................................................... 16
2.5.5 Disconnecting BUs............................................................................................. 19
2.5.6 First Time Operation .......................................................................................... 20
3 Terminal Station Installation............................................................................... 21
3.1 General .............................................................................................................. 21
3.2 Packing List........................................................................................................ 21
3.2.1 Items not supplied in Packing List...................................................................... 21
3.2.2 Terminal Station Connectors ............................................................................. 22
3.2.3 Terminal Station Cables..................................................................................... 22
3.3 Terminal Station Installation Concept ................................................................ 23
3.4 Installing the Outdoor Equipment....................................................................... 23
3.4.1 Installing Mounting Adapter, Type 1 .................................................................. 24
3.4.2 Installing Mounting Adapter, Type 2 .................................................................. 25
3.4.3 Connecting the IF Cable .................................................................................... 26
3.5 Installing the Indoor Equipment ......................................................................... 26
3.5.1 BU-TS Interfaces ............................................................................................... 27
3.5.2 BU-TS LED Indications ...................................................................................... 28
3.5.3 Wall Mounting .................................................................................................... 28
3.5.4 Rack Mounting ................................................................................................... 30
3.5.5 Desktop Installation............................................................................................ 30
3.5.6 Completing the Indoor Installation ..................................................................... 30
4 Cable Pin-out ..................................................................................................... 31
4.1 LCI ..................................................................................................................... 31
4.2 Base Station Cable Pin-out................................................................................ 31
4.3 Terminal Station Cables Pin-out ........................................................................ 33
5 Abbreviations ..................................................................................................... 34
A50010-Z3-C100-1-7631 3
UMN:IMN Installation
WALKair™ V2.0
Figures
Fig. 1.1 WALKair System Architecture ......................................................................... 5
Fig. 2.1 Base Station Installation - Typical Configuration ........................................... 10
Fig. 2.2 Mounting Antenna on the Pole ...................................................................... 11
Fig. 2.3 Mounting Bands ............................................................................................ 12
Fig. 2.4 Antenna Decoupling ...................................................................................... 12
Fig. 2.5 RFU/Antenna Cable Loop ............................................................................. 12
Fig. 2.6 BU-BS Front Panel........................................................................................ 14
Fig. 2.7 BU-BS Rear Panel ........................................................................................ 14
Fig. 2.8 IF Multiplexer Front Panel (8-Port Model Shown) ......................................... 15
Fig. 2.9 IF Multiplexer Rear Panel.............................................................................. 15
Fig. 2.10 Attaching the Mounting Brackets for ETSI Racks ....................................... 16
Fig. 2.11 Attaching the Mounting Brackets for 19" Racks .......................................... 17
Fig. 2.12 Indoor Equipment Installation using Vertical Rack-Mounting (3 Sector
Configuration) .............................................................................................. 18
Fig. 2.13 Connecting Mounting Bars to the Rack....................................................... 18
Fig. 3.1 Terminal Station Installation - Wall Mounted Configuration .......................... 23
Fig. 3.2 Mounting Adapter - Type 1............................................................................ 24
Fig. 3.3 Mounting Bracket - Type 2 ............................................................................ 25
Fig. 3.4 TS/RFU Pole Mounting ................................................................................. 26
Fig. 3.5 BU-TS Front Panel ........................................................................................ 27
Fig. 3.6 BU-TS Rear Panel (48 VDC Power Option).................................................. 27
Fig. 3.7 BU-TS Rear Panel (220 VAC Power Option) ................................................ 27
Fig. 3.8 BU-TS Wall Mounting.................................................................................... 29
Tables
4 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
1 Introduction
This document describes the installation process for the WALKair system.
á 10.5 GHz
á 3.5 GHz
RFU +
Antenna
Antenna
. Terminal
Down Link Tx, Rx, DC
Station (TS)
RFU
. BU
Up Link
.
Tx, Rx, DC
IF-MUX
RFU +
BU Antenna
BU
Terminal
BU Tx, Rx, DC Station (TS)
Base Station (BS) BU
Sector
The base station provides telecom service to Terminal Stations (TSs) which are
installed at the customer premises and connected to the CPE (such as PBXs,
fax machines, PCs).
WALKair implements a proprietary, patent-pending air protocol for communication
between the base station and terminal stations. The access method is based on a
TDMA/FDMA/FDD scheme.
WALKair features a modular architecture which helps reduce startup costs, minimize
initial investment and maximize gradual growth capabilities.
A50010-Z3-C100-1-7631 5
UMN:IMN Installation
WALKair™ V2.0
6 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
2.1 General
The base station provides service to a coverage area of up to 10 km, extended in a
o
360 radius (referred to as a cell). The base station provides the interfaces to the
telecom switches. The base station consists of several sectors, which cover the cell
o o o
(the cell can be covered by 3 sectors of 120 , 6 sectors of 60 or a combination of 60
o
and 120 antennas).
The configuration of the sector is modular, and can contain from one to 16 Basic Units
(BU-BS), an IF Multiplexer, a RF unit and an antenna.
All equipment complies with the ETSI 300-019 standard (indoor: class 3.2;
outdoor: class 4.1E).
A50010-Z3-C100-1-7631 7
UMN:IMN Installation
WALKair™ V2.0
8 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
• Rack
⇒ Standard 19” or ETSI
⇒ 600 depth
⇒ Slow blow fuse of at least 5 A
⇒ Power consumption
◊ BU - 40 W
◊ IF-MUX - 8 W
◊ RFU - 80 W
⇒ Heat dissipation
◊ BU - 35 W
◊ IF-MUX - 3 W
⇒ Rack Space - Total of 62.2 cm:
◊ 44 cm (vertical BUs)
◊ 2 x 4.7 cm (2 mounting bars)
◊ 4.4 cm (1U) space between the upper bar and the first IF-MUX
◊ 4.4 cm (IF-MUX)
Note:
1. Up to 3 IF-MUX can be installed on the same rack.
The equipment need both front and rear access.
2. 1U space from fan should be maintained.
Connector Description
RFU 2 x N-type Flange Mount Cable Jack straight connectors
Antenna 1 x N-type Flange Mount Cable Jack straight connector
IF-MUX • 1 x N-type Flange Mount Cable Jack straight connector
• 8 x dual SMA connectors
BU-BS • IF-Dual SMA connectors
• Telecom - 2xRJ45 (pin-out described in Section 4)
• LCI-RJ45 (pin-out described below in Section 4)
• Modem - RJ 45 (pin-out described in Section 4) - not in use
• Ethernet - RJ45 (pin-out described below) - not in use
Power connector 3-pin D-type connector, Manufacturer AMPHENOL, P/N 17DAM3W3S (female)
A50010-Z3-C100-1-7631 9
UMN:IMN Installation
WALKair™ V2.0
Cable Description
Outdoor cables
RFU ↔ Antenna LMR600, 2 x Cable Plus connector (supplied by WALKair)
IF-MUX ↔ RFU LMR400, 1 x Cable Plus 2 connectors
indoor - outdoor cable
Indoor cables
E1 cable 4 STP category 5, RJ45 connector
LCI cable 4 STP category 5, RJ45 connector
Power cable 48 VDC, 5 AMP, 90o cable plug connector, shielded
Jumper cable RG 316, male SMA connectors (supplied by WALKair)
COAX CABLE
RFU - BS
ANTENNA
IF-MUX
TELECOM
INTERFACES
IF CABLE
ETHERNET
BU1 . . . BU8
RS232
RACK
LCI
COMPATIBLE
FOR ETSI & 19”
10 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
RFU
• Antenna port
IF Port
• Grounding pin
Mounting pole
Antenna
A50010-Z3-C100-1-7631 11
UMN:IMN Installation
WALKair™ V2.0
4. Tighten the bands that you inserted around the pole, using an electric screwdriver
(recommended). The band fits any size pole up to 115 mm in diameter.
Minimum
distance:
1 meter
RFU
Strip
12 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
A50010-Z3-C100-1-7631 13
UMN:IMN Installation
WALKair™ V2.0
a b c
Port 2 Port 1 Port 0
XXXXXXXX
Rx Tx
a s d f g
Note: Some of the BU front panels may have the following signs instead of Tx/Rx:
Tx (Output from the BU)
Rx (Input to the BU)
I SYS CLK
I I I
N OUT
N
Input Vol: 48VDC
OUT
Input Curr: 5
EXTENSION BUS BSXXXXXX
Amp
h j k l
14 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
Inp ut Vo l: 36-72VDC IN
Inp ut Curr: 3Am p
OUT
EXTENSION BUS
IF IN/OUT XXXXXXXXXX
PWR
LED Description
Fail For future use
Power Lights green when the unit’s power supply is operating normally
A50010-Z3-C100-1-7631 15
UMN:IMN Installation
WALKair™ V2.0
16 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
A50010-Z3-C100-1-7631 17
UMN:IMN Installation
WALKair™ V2.0
MUX 3
MOUNTING
BRACKET MUX 2
MUX 1
MOUNTING BAR
BS/BU8
BS/BU1
MOUNTING BAR
Upper Bar
Screw holes
44cm (19’’)
Lower Bar
Screw holes
18 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
A50010-Z3-C100-1-7631 19
UMN:IMN Installation
WALKair™ V2.0
LED Description
Outdoor Indicates the status of the outdoor equipment
e.g., failure in the RFU or a lost connection with one of the TSs)
Indoor Indicates the status of the indoor equipment
(e.g., LOS on one of the E1s connected to the BU-BS)
Ethernet Indicates the status of the Ethernet port. Intended for future use.
20 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
3.1 General
The Terminal Station (TS) is located at the customer premises and is connected to the
Customer Premises Equipment (CPE).
All equipment complies with the ETSI 300-019 standard (indoor: class 3.2;
outdoor: class 4.1E).
A50010-Z3-C100-1-7631 21
UMN:IMN Installation
WALKair™ V2.0
Connector Description
RFU 1 x N-type Flange Mount Cable Jack straight connector
TS-BU • IF - 1 x N-type Flange Mount Cable Jack connector
Indoor - Outdoor • Telecom - J45 (pin-out described below)
• LCI - RJ45 (pin-out described below)
Power connector 110/220 - SCHURTER (P/N 5200.0223.1) power entry Module (male)
48 V - 3-pin D-type connector, Manufacturer AMPHENOL, P/N 17DAM3W3S (female)
Cable Description
Outdoor cables
RFU ↔ BU-TS LMR400, 1 x 180 cable plug connector, 1 x 90 cable plug connector
Indoor cables
E1 cable 4 STP category 5, RJ45 connector
LCI cable 4 STP category 5, RJ45 connector
Power cable 250 VAC, 10 AMP, 90o cable plug connector, shielded
22 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
RFU + ANTENNA
CABLE
TS
TELECOM INTERFACES
PC
Serial LCI
A50010-Z3-C100-1-7631 23
UMN:IMN Installation
WALKair™ V2.0
4
2
Openings for
bands
Elevation nut
1 and screw
7. Position the RFU on the desired location on the pole, aligning the pole into the
designated mounting adapter slot; this slot is designed to fit a wide range of poles.
The band will fit any pole up to 110 mm (4’’) in diameter. Use an electrical screw-
driver (recommended) to tighten the bands around the pole.
24 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
3DUW%
3DUW$
A50010-Z3-C100-1-7631 25
UMN:IMN Installation
WALKair™ V2.0
8. Position the RFU on the desired location on the pole, aligning the pole into the
designated mounting adapter slot; this slot is specially designed to file a wide range
of poles, up to 115-mm diameter. Tighten the bands around the pole with an
electrical screwdriver.
26 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
The TS indoor equipment is comprised of a single Base Unit (BU-TS), which can be
installed using one of the following options:
• Wall mounted
• Desktop
• Rack mounted (19" or ETSI racks)
The indoor mounted BU-TS features front panel connection points for easy access to
all interfaces.
A single coaxial cable connects the indoor BU-TS to the outdoor unit.
xxxxxxxx
Rx Tx INT EXT
Tx R x E1/P-ISDN
Tx Rx E1/P-ISDN Tx Rx E1/P-ISDN
xxxxxxxx LCI
Note: Some of the BU front panels may have the following signs instead of Tx/Rx:
Tx (Output from the BU)
Rx (Input to the BU)
A50010-Z3-C100-1-7631 27
UMN:IMN Installation
WALKair™ V2.0
LED Description
Outdoor Indicates the status of the outdoor equipment
(e.g., failure in the RFU or a lost connection with one of the TSs)
Indoor Indicates the status of the indoor equipment
(e.g., LOS on one of the E1s connected to the BU-TS)
28 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
Connect to
RFU
xxxxxxxx
Tx
Rx
E1/P-ISDN
Tx
Rx
E1/P-ISDN
Tx
Rx
E1/P-ISDN
INT EXT
xxxxxxxx
LCI
A50010-Z3-C100-1-7631 29
UMN:IMN Installation
WALKair™ V2.0
30 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
4 Cable Pin-out
4.1 LCI
The commissioning process is performed using a Local Craft Terminal connected to
BU-BSs and BU-TSs via RS232 interface. Tab. 4.1 describes the pin-out necessary for
LCI connection.
Pin Description
1 Shield
2 Rx
3 Tx
4 Shield
5 GND
6 Shield
7 Shield
8 Shield
A50010-Z3-C100-1-7631 31
UMN:IMN Installation
WALKair™ V2.0
Pin Description
1 +15 V
2 Rx
3 Tx
4 DSR
5 GND
6 DCD
7 CTS
8 RTS
Pin Description
1 Tx
2 Tx
3 Rx
4 Shield
5 Shield
6 Rx
7 Shield
8 Shield
Pin Description
1 Shield
2 Shield
3 Ring
4 Tip
5 Shield
6 Shield
7 Shield
8 Shield
Pin Description
1 Shield
2 Shield
3 Ring
4 Tip
5 Shield
6 Shield
7 Shield
8 Shield
32 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
Pin Description
1 Shield
2 Rx
3 Tx
4 Shield
5 GND
6 Shield
7 Shield
8 Shield
Pin Description
1 Shield
2 Shield
3 Ring
4 Tip
5 Shield
6 Shield
7 Shield
8 Shield
A50010-Z3-C100-1-7631 33
UMN:IMN Installation
WALKair™ V2.0
5 Abbreviations
AC Alternating Current
ATM Asynchronous Transfer Mode
BER Bit Error Rate
BRI Basic Rate Interface
BS Base Station
BU-BS Base Station Basic Unit
BU Basic Unit
CPE Customer Premises Equipment
CPU Central Processing Unit
CRC Cyclic Redundant Check
DC Direct Current
DLC Data Link Control
EOC Embedded Operation Channel
ETSI European Telecommunications Standards Institute
FDD Frequency Duplexing Division
FDMA Frequency Division Multiple Access
GHz Giga Hertz
IF Intermediate Frequency
ISDN Integrated Services Digital Network
ITU-T International Telecommunications Union
Telecommunications Standardization Sector
LAN Local Area Network
LCI Local Craft Interface
LLC Logical Link Control
LOS Loss of Signal
MAC Media Access Control
Mbps Mega Bits per Second
MHz Mega Hertz
PBX Private Branch Exchange
PAD Packet Assembler/Disassembler
PC Personal Computer
PCM Pulse Code Modulation
PM Performance Monitoring
PMP Point-to-Multi-Point
PRI Primary Rate Interface
QAM Quadrature Amplitude Modulation
34 A50010-Z3-C100-1-7631
Installation UMN:IMN
WALKair™ V2.0
A50010-Z3-C100-1-7631 35
UMN:IMN Installation
WALKair™ V2.0
36 A50010-Z3-C100-1-7631