Vous êtes sur la page 1sur 8

900MA/MAM and 1000MA/MAM

(for marine applications)


Fuel Filter/Water Separator

Instruction Part Number 19526 Rev B

Racor Turbine Series fuel filter/


water separator protects the
precision components of your
engine from dirt, rust, algae,
asphaltines, varnishes and
especially water, which is
prevalent in low distillate fuels.
Contaminants are removed from
fuel using the following legendary
three stage process:

Stage 1Separation
Using the fuel flow, the stationary
turbine separates large solids and
free water through enchanced
centrifugal force.

Stage 2Coalescing
Smaller water droplets and solids
coalesce on the conical baffle and
fall to the collection bowl.

Stage 3Filtration
Engines will benefit from near
100% water separation and fuel
filtration with Racors proprietary Contact Information
RINE
Aquabloc water repelling media. MA
The replaceable filters are Parker Hannifin Corporation
available in 2, 10, and 30 micron Racor Division
P.O. Box 3208
TY P E

CT

ratings.
3400 Finch Road
DU

PP
A

RO V E D P R Modesto, CA 95353
ABS/BV Phone 800 344 3286
209 521 7860
Fax 209 529 3278
Email racor@parker.com
Web parker.com/racor
Mounting Information
5.8 in. 5.8 in.
(14.7 cm) (14.7 cm)
900 Models 1000 Models
4.5 in
(11.4 cm)

5.0 in
11.0 in (12.7 cm)
4.5 in
(27.9 cm)
(11.4 cm)
Adjustable to
13.5 in
(34.3 cm)
10.9 in
V (27.7 cm)
10 10
Adjustable
by 2.1 in.
90 (5.3 cm)
Note: Mount filter assembly as close to vertical (V) as possible.
Do not exceed 10 from vertical or assembly may not function
properly. Fastener size is 3/8" (M10) for mounting brackets.

Adjust mounting brackets (900 models have


one, 1000 models have two) for a secure fit.

Installation Diagram
Fuel tanks above filter
Optional Bypass Installation and Operation Maintain a clearance head pressure should not
(allows user to service filter without shutting down engine.) above the filter assembly exceed maximum PSI of filter.
Valves 1 2 3 of 5 in. (12.7 cm) (900MA),
and 10 in. (25.4 cm) (1000MA)
Unit On-line Open Open Closed for filter removal. Fuel Tank
Unit Off-line Closed Closed Open (Pressure Side Installation)
Pressure Side:
Fuel transfer pump not to exceed
maximum PSI or flow rate of filter.
Not ideal - pumps emulsify water
Suction (vacuum) Side: hindering filter performance. Install a shut-off valve when
Primary (first) filter - use 30 micron. fuel tank is higher than filter
If it is the only filter in the system,
use 2 or 10 micron.

Fuel Tank
Engine (Ideal Vacuum
Side Installation)
Valve 2 Valve 1

Install a check valve


(with light or no restriction)
when tank is lower than filter
to maintain prime.

Fuel transfer pump


(IDEAL vacuum side installation) Fuel Tank
Valve 3 (Vacuum Side Installation)

Maintain a service clearance below


filter assembly of at least 2 in. (5.1 cm) Fuel tank below filter
for draining and servicing bowl. Do not exceed 5 (1.5m) of lift
or 4 inches of mercury (inHg)
of inlet piping restrictions
Installation Guidelines
These customer supplied BEFORE Installing The Filter When routing hose, avoid
materials should be on hand Assembly surfaces that move, have sharp
before beginning installation. edges, or get hot (such as
Obtain good ventilation and
exhaust piping).
Shop Towels lighting.
Avoid using one-way check
Mounting Hardware (3/8) Maintain a safe working
valves that have an opening
environment.
Inlet/Outlet Fittings pressure higher than 0.5 PSI
Engine must be off for (0.03 bar).
Fuel Hose
installation.
Clean Diesel Fuel (about 1 gal.)
DO NOT smoke or allow open
Clean Motor Oil flames near installation. Priming Instructions
Thread Sealant (no thread tapes) 1. Remove T-handle and lid from
Installing The Filter Assembly top of filter assembly.
Positioning The Filter Assembly
Completely remove any suction 2. Fill filter with clean fuel.
Install filter assembly on suction side filters in fuel system
side of fuel transfer pump for between fuel tank and fuel 3. Lubricate lid gasket and
optimum water separating pump. This is where the Racor T-handle O-ring with clean fuel
efficiency. See Installation Diagram. filter will mount. Leaving these or motor oil.
filters in place will add to fuel
Keep fuel line restrictions to 4. Replace lid and T-handle and
system restriction. Filter heads
a minimum. Locate the filter tighten snugly by hand
cast into the engine or that are
assembly between horizontal onlydo not use tools.
non-removable or hard piped
planes of the bottom of the fuel should be serviced with a new 5. If applicable, refer to
tank and inlet of fuel pump, if filter and left in place. equipment operators service
possible. If filter assembly is manual to complete fuel
installed in an application where Keep fuel flow restriction priming procedure.
the fuel tank is higher than the to a minimum. Always use
filter, a shut-off valve must be the maximum size fuel hose 6. Start engine and check for
installed between the tank and possible. Do not make sharp fuel system leaks. Correct as
filter assembly INLET. This will bends with flexible hose as kinks necessary with engine off and
be used when servicing the may occur. Avoid use of two 45 pressure relieved from filter
replacement filter. elbow fittings where one 90 assembly.
elbow will work.

Service Instructions
Draining Water Suction Side Pressure Side
Frequency of water draining is Applications Applications
determined by the contamination
level of the fuel. Inspect or drain 1. C
 lose inlet valve (or valve #1) 1. Open self-venting drain
collection bowl of water daily or as and open self-venting drain on on bottom of bowl. Head
necessary. Collection bowl must bottom of bowl. pressure will push any water
be drained before contaminants and contaminants out of drain
reach the bottom of the turbine 2. C
 lose drain after all water while keeping filter primed.
(inside the bowl), or when the and contaminants have been
2. Close drain after all water
Water Detection Module (optional) evacuatedDO NOT leave
and contaminants have been
indicates a drain is required. drain open too long as it will
evacuatedDO NOT leave
eventually completely drain
drain open too long as it will
entire filter of water AND fuel.
eventually completely drain
3. Follow Priming Instructions. entire filter of water AND fuel,
and possibly drain entire tank.
Filter Replacement
Frequency of filter replacement is All Applications debris. Lubricate new gasket
determined by the contamination and seal (supplied with new
level of your fuel. Replace filter 1. Isolate the filter assembly with filter) with motor oil or diesel
every 500 hours, every other oil bypass or shut-off valves, if fuel before installation.
change, when vacuum gauge applicable. 5. Refer to Priming Instructions,
(optional) reads between 7 to otherwise, fill unit with clean
10 inches of mercury (inHg), if 2. Remove T-handle and lid.
fuel, replace lid and T-handle
power loss is noticed, or annually,
3. Remove filters by holding bail and tighten snuggly by hand
whichever occurs first.
handles and slowly pulling onlydo not use tools.
Notealways carry extra upward with a twisting motion. 6. Open any closed valves; if
replacement filters as one tankful Dispose properly according to applicable.
of excessively dirty fuel can plug local regulations.
a filter. Noteabove ground tanks or
4. Remove and discard old lid transfer pump applications may
Use only genuine Racor Aquabloc gasket and T-handle O-ring and use head pressure to prime filter
replacement filterssee Part List. clean seal glands of any dirt or assembly.

Specifications
900MA 1000MA
or or
900MAM 1000MAM

Maximum Flow Rate: 90 GPH (341 LPH) 180 GPH (681 LPH)

7/8"-14 UNF (SAE J1926) 7/8"-14 UNF (SAE J1926)


Port Size
(female threads) (female threads)
Min. Service Clearance:
Above Assembly 7.5 in. (19.1 cm) 10.0 in. (25.4 cm)
Below Assembly 2.0 in (5.1 cm) 2.0 in. (5.1 cm)
Replacement Filter:
(2 micron) 2040SM-OR or 2040N-02 2020SM-OR or 2020N-02
(10 micron) 2040TM-OR or 2040N-10 2020TM-OR or 2020N-10
(30 micron) 2040PM-OR or 2040N-30 2020PM-OR or 2020N-30
Height MA 17.0 in. (43.2 cm) 22.0 in. (55.9 cm)
MAM 16.5 in. (41.9 cm) 21.9 in. (54.5 cm)
Depth 7.0 in. (17.8 cm) 7.0 in. (17.8 cm)
Width 6.0 in. (15.2 cm) 6.0 in. (15.2 cm)
Weight (dry) MA 6.0 lb (2.7 kg) 10.0 lb (4.5 kg)
MAM 7.0 lb (3.2 kg) 11.0 lb (5.0 kg)
Clean Pressure Drop 0.30 PSI (0.021 bar) 0.43 PSI (0.03 bar)
Maximum Allowable Working
25 PSI (1.7 bar) 25 PSI (1.7 bar)
Pressure
Water Removal Efficiency 99% 99%

Ambient Temperature Range -40 o to +255 oF (-40 o to +124 oC)

Maximum Fuel Temperature 190F (88C)


Part List 1

1a
2
Part Number Description
2a
T-handle and O-ring Kit (includes 1a)
RK 11-1945 (Brass)
1 (9/16-18 UNF Threads)
RK23183 (Stainless Steel)
Hand Tighten
1a RK11350 T-handle O-ring
2 RK 11-1933-04 Lid Kit (includes 2a) 3
2a RK11007 Lid Seal
2040N-02 (2 micron), or
2040N-10 (10 micron), or 900MA/MAM (includes 2a)
2040N-30 (30 micron)
3
2020N-02 (2 micron), or
4
2020N-10 (10 micron), or 1000MA/MAM (includes 2a)
2020N-30 (30 micron)
RK11-2006 900MA/MAM Clamp Bracket Kit
4 A
RK11-2008 1000MA/MAM Double-welded Clamp Bracket Kit
900MA/MAM Body/Housing 5a 5
A (not sold seperately)
1000MA/MAM Body/Housing
Feed-thru Plug Kit (includes 5a)
5 RK 11-1679
Tighten 15 in. lbs (1.69 Nm) max.
5a 43506 Plug O-ring
6 Check Ball Seal 6
RK 11028B
7 Check Ball 7

RK23191 (water sensor for MAM units)1


8 Conical Baffle Kit (includes 6, 7, and 10a) 8

RK 21069 (water sensor for MA units)1


RK 11-1939 Turbine Centrifuge Kit
9
Hand Tighten 9
RK 11-1606-1 (MA models) Clear Bowl Kit (includes 10a, 11, and 11a)
10
RK 11734-03 (MAM models) Metal Bowl Kit (includes 10a, 11, and 12a)
10a
10a RK11007 Bowl Seal
RK 20126 (MA models) Plastic Bowl Plug Kit (includes 11a)
11 RK 20022 (MAM models) Metal Bowl Plug Kit (includes 11a)
10
Tighten 15 in. lbs (1.69 Nm) max.
11a (not sold seperately) Water Probe or Plug O-ring
Bowl Drain fitting Kit (includes 12a, 12b,
12 RK 11-1910 and 12c) 11a
Tighten 30 in. lbs (3.39 Nm) max. 11
12a 918-N4 Drain Plug 12b
12c
12b (not sold seperately) Drain Fitting O-ring
12c (not sold seperately) Bowl Drain Washer 13
13 RK 11868 MA Heat Deflector Kit (includes 12) 16
12
14 RK 11037A Bowl Ring Kit (includes 10a and 15)
12a
Bowl Fasteners (4ea.)
15 RK 11542
Tighten 60 in. lbs (6.78 Nm) max. 14
1
Must be used with a water detection amplifiercontact Racor for selection info. 15
Troubleshooting
Damaged, worn, or dirty seals will allow air ingestion.
Inspect and replace all seals as needed. Clean the sealing
surfaces of dirt or debris every time the filter is replaced.

Hand tighten T-handle only! Do not Replace T-handle o-ring and lid
use tools for leverage. gasket with each filter element
replacement.

If filter is changed or assembly


drained for any reason, reprime
assembly. Fill to just above Replace filter every 500 hours, every
top of filter before replacing other oil change, annually, or at first
lid. It is normal for the fuel indication of power loss, whichever
level to drop during use. This occurs first.
is especially apparent at filter
element change-out.

Filter safety valve

Do not overtighten carriage


SAE O-ring ports should have a
bolt as this may distort the
smooth angled seat for sealing.
bracket position.
Do not scratch this surface. Check
O-ring for damage.

Do not over tighten self-


Optional heater port not used on
tapping capscrews to avoid
marine models. Plug feed-thru O-ring
stripping out body threads.
must not be damaged or swollen.
After disassembly, start
Tighten to 15-20 in. lbs.
threads by hand prior to using
tools. Tighten to 55-65 in. lbs.
Air bubbles appearing from turbine
are an indication of an upstream
The hollow aluminum checkball leak between Racor inlet and fuel
floats up against the seal when tank pick-up tube.
fuel is stopped, preventing
fuel bleed-back. If unit looses
prime, inspect upstream hose Drain water (if present) before it
connections first, disassemble gets to this level. At some time, the
unit to inspect seal and ball. see-thru contaminant collection
(It is normal to hear a "rattling" bowl may become dirty on the
sound at any time). inside. Remove the four bowl ring
capscrews and drop the bowl. Clean
the inside with hot soapy water,
dry off and re-install. Ensure bowl
Air bubbles or fuel leakage gasket is cleaned, and lubricate with
appearing from drain may indicate silicone grease prior to reuse.
drain is not closed completely
or seal has been clogged
with contaminants. Tighten or A plug is installed as standard,
disassemble and inspect. Tighten but can be replaced with a Water
to 30-35 in. lbs. Sensor. Tighten to 15-20 in. lbs.

The water sensor (if equipped)


should activate when water
contacts tips. Air bubbles or fuel
leakage appearing from sensor
may indicate it is loose or O-ring is
damaged. Tighten to 15-20 in. lbs.
Troubleshooting
NoteCorrect external fuel FilterReplacement filters with the in-bowl sensor. The
leaks immediately! These are available in 2, 10, and 30 unit should activate when
conditions are dangerous and micron ratings. Filtration needs water reaches sensor tips (and
are a fire hazard. Additionally, are based on application, when they measure between
reduced engine performance fuel quality, maintenance 47,000 and 100,000 ohms
such as: hard starting, schedules, and operating of resistance, depending on
stalling, reduced power, and climates. A simple rule to detection module used.) If
other associated problems remember is, the finer the not, tips may be fouled with a
will result. filtration (i.e. the smaller the coating. Remove water sensor
number), the more frequent and clean tips with a cloth.
New filter installations the filter change. Always carry Run a jumper wire between
must be filled with fuel extra replacement filters with tips with ignition ON to test
and fuel system must be your equipment as one tankful system. Difficulties usually lie
adequately primed following of excessively contaminated in the wire connections, power
the engine manufacturers fuel can plug a filter. When source, or an independent
recommendations, if clogged to the maximum ground.
applicable. Existing installation capacity, filters will have a
difficulties are usually brown to black color or tar like All Racor filter assemblies
associated with improper contaminants may be present are 100% tested to ensure a
priming procedures or damage - this is normal. An appearance leakproof, quality product.
to the unit or fuel system. of a multi-colored slime (which
The result is either internal NoteCorrect external fuel
may have a foul odor) is an
air suction or external fuel leaks immediately! In the event
indication of microbiological
leakage. Diagnosis should be difficulties are experienced
contamination. This condition
in these following steps: with your filter assembly or a
must be treated immediately.
problem appears to prevent the
1. C
 heck fuel tank level and Severe conditions must be engine from running smoothly,
make sure any fuel delivery corrected by a repair facility. refer to the procedures on
valves are in open position, the previous page. Note
as applicable. NoteNever operate Racor Apply Parker Super O-lube
unit without the filter in place (part number RK31605) or
2. E
 nsure T-handle, bowl - the 'filter safety valve' will equivalent to all seals at major
fasteners, and fuel fittings not expose outlet hole on fuel
are tight. Also verify that attachment points to maintain
return tube if filter is removed integrity, seal elasticity, to fill
bowl drain is closed. and fuel will not flow to engine.
small voids, and to provide
Instead, punch emergency tab
3. If filter is new, check protection from degradation.
on the top of filter and leave in
potential restriction at fuel
place. Puncturing emergency Perform all checks with
tank draw tube. An in-tank
tab will bypass all filtration and engine OFF (and applicable
strainer may be plugged.
send unfiltered fuel to your valves closed). For
Correct ApplicationIt is engine. Service filter as soon replacement parts, refer to
very important that filter is as possible to avoid harmful the Part List section of this
not under specified for the contaminants flowing manual.
application. The maximum downstream to engine.
fuel flow rating of filter must
Water SensorsThis feature
not be exceeded and engine
alerts operator of a high-
manufactures maximum fuel
water condition. The bowl
inlet restriction, must not be
is then drained of water at
exceeded. Doing so will reduce
earliest convenience. Note
efficiency and de-gas (pull air
- a Racor water detection
from) fuel.
module is needed to work
Limited Warranties Statement
All products manufactured FLOWING FROM THE USE OF and/or system options for
or distributed by Racor are ANY DEFECTIVE PRODUCT further investigation by users
subject to the following, and OR BY REASON OF THE having technical expertise.
only the following, LIMITED FAILURE OF ANY PRODUCT. It is important that you
EXPRESS WARRANTIES, and RACOR SPECIFICALLY analyze all aspects of your
no others: For a period of DISAVOWS ALL OTHER application and review the
one (1) year from and after WARRANTIES, EXPRESS information concerning the
the date of purchase of a new OR IMPLIED INCLUDING, product or system in the
Racor product, Racor warrants WITHOUT LIMITATION, ALL current product catalog. Due
and guarantees only to the WARRANTIES OF FITNESS to the variety of operating
original purchaser-user that FOR A PARTICULAR PURPOSE conditions and applications
such a product shall be free (EXCEPT FOR THOSE WHICH for these products or systems,
from defects of materials APPLY TO PRODUCT OR the user, through its own
and workmanship in the PART THEREOF THAT IS analysis and testing, is solely
manufacturing process. The USED OR BOUGHT FOR USE responsible for making the
warranty period for pumps and PRIMARILY FOR PERSONAL, final selection of the products
motors is specifically limited FAMILY, OR HOUSEHOLD and systems and assuring that
to ninety (90) days from date of PURPOSES), WARRANTIES OF all performance, safety and
purchase. A product claimed to DESCRIPTION, WARRANTIES warning requirements of the
be defective must be returned OF MERCHANTABILITY, applications are met.
to the place of purchase. Racor, TRADE USAGE OR The products described
at its sole option, shall replace WARRANTIES OR TRADE herein, including with
the defective product with a USAGE. limitation, product features,
comparable new product or specifications, designs,
repair the defective product. availability and pricing, are
This express warranty shall be subject to change by Parker
Warning Hannifin Corporation and
inapplicable to any product not
properly installed and properly Failure or improper selection its subsidiaries at any time
used by the purchaser-user or improper use of the without notice.
or to any product damaged or products and/or systems
impaired by external forces. described herein or related The following statement
items can cause death, is required pursuant to
THIS IS THE EXTENT OF personal injury and property proposition 65, applicable
WARRANTIES AVAILABLE damage. This document and in the State of California:
ON THIS PRODUCT. RACOR other information from Parker This product may contain a
SHALL HAVE NO LIABILITY Hannifin Corporation, its chemical known to the State of
WHATSOEVER FOR subsidiaries and authorized California to cause cancer or
CONSEQUENTIAL DAMAGES distributors provide product reproductive toxicity.

Parker Hannifin Corporation March 2013

Vous aimerez peut-être aussi