EIS Installation Checklist for Sun StorageTek SL500 Modular

Storage Library

Customer
Sun Order Number:
CASE Number:
Technician:
Version EIS-DVD:
Date:

It is recommend that the EIS web pages are checked for the latest version of this
checklist prior to commencing the installation.
It is assumed that the installation is carried out with the help of the current
EIS-DVD. See EIS web pages for current information and status.
The idea behind this checklist is to help the installer achieve a "good" installation.
It is assumed that the installer has attended the appropriate training classes.
Although use of a laptop and the StorageTek Library Console (SLC) is not
required to achieve a minimal functioning installation, a laptop running the
StorageTek Library Console (SLC) is highly recommended and should be
considered best practice. Steps in this checklist require it's use.
This checklist can either be used when installing a new server with storage (in
conjunction with appropriate server checklist) or just ArrayStart when adding a
SL500 storage.
It is not intended that this checklist be handed over to the customer.
This checklist refers to the Customer Orientation Checklist.
If ACSLS ( Automated Cartridge System Library Software ) is being used with a
SL500 with LTO5 drives a minimum version of ACSLS 7.3.1 or 8.0.1 is needed.

In contrast to most EIS installation checklists, this checklist assumes that:


The installer has attended the SL500 Field Service and Frontline Training (ISTK-
1840).
The installer has access to Sun Technical Documentation at: http://download-
adc.oracle.com/archive/cd_ns/E21115_01/
https://support.us.oracle.com/handbook_internal/STK/STK_index.html
That the SL500 Installation Manual is available and referred to during the
installation.

Serial# SiteID
SL500

Sun Internal and Approved Partners Only Page 1 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

PREPARATION FIELD INSTALLER


Site Audit complete? EISdoc V4:
See EIS website Site Audit. File EIS-DOCS-SiteAudit-
Standard.odt
EIS Installation Configuration Plan & Test EISdoc V4:
Procedures Plan complete? Use appropriate BUILD and TPP
documentation.
Open an installation service ticket. In the U.S. open a Remedy ticket by
calling 1-800-USA-4SUN.
AMER Canada: Process unavailable
EMEA: Process unavailable
APAC: Process unavailable
Obtain the latest microcode from: To find available code versions:
https://dlrequest-zn-
https://dlrequest-zn- dlapps1.sfbay.sun.com/usr/search
dlapps1.sfbay.sun.com/usr/search
select Log In .
select Search tab.
search on SL500.
Find the latest code.
Obtain the latest versions of required Check for latest versions at:
manuals: http://download-
adc.oracle.com/archive/cd_ns/E21115
Sun StorageTek SL500 Systems _01/
Assurance Guide, Select the appropriate documents:
http://download-
Sun StorageTek SL500 Installation adc.oracle.com/archive/cd_ns/E2
Manual. 1115_01/

These contain detailed information about


the SL500 and its installation.
Check that required tools are available. See the Planning the Installation
section of the SL500 Installation
Manual.
Tools required for the installation are
included in the standard-issue tool kit.
314829201 Optional install toolkit
makes it possible for one person to
install the original design base unit.
Obtain Library Activation Passwords for Required for running the SLC. The
the following user names: admin password is intended for
customer use, service password is
admin intended for field engineers.
Request the passwords at
service https://crcapplications.us.oracle.c
om/keyswebapp/
Enter your email address and
LDAP.
Fill in required fields.
Repeat steps for second password.

Sun Internal and Approved Partners Only Page 2 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check
Ensure that laptop or other means to To use the CLI with most Windows
communicate through the CLI is available, Operating Systems:
Connect the PC/Host to the CLI
and test the CLI connection.
Port on the RLC Card using a
serial cable.
Start a Hyper-Terminal session
The optional SLC runs on Windows 2000/XP and
Select COM1 from the Connect
the Solaris platform. Most field laptops will utilize
the Windows 2000/XP version. Examples in this Using menu
checklist assume this. Set the following port settings:
1. Baud Rate: 38,400
2. Data Bits: 8
3. Parity Bit: None
4. Stop Bit: 1
5. Flow Control: none
6. Click OK and Press enter
7. At the login prompt enter
service
8. Answer yes to the prompt
are you sure you want to
continue
9. When the password prompt
appears, enter the password
created in the Obtain
Passwords checklist item
above.
Know your component types! EZ EZ Hardware modules have arrays,
Hardware and Original Design components doors and front panels already
installed on the module.
differ.
EZ Hardware modules can be installed
with existing original design
hardware, but original design
hardware can not be installed with a
library containing all EZ hardware
components.
Refer to the Installing EZ hardware
or Installing Original Design
Hardware sections of the SL500
Installation Manual for compatibility
issues.
Review latest Field Action Bulletins FABs
(ex-FIN/FCO) information.
Cables. Minimal cabling requires a serial null
modem cable for CLI interface
connection to your host or laptop,
standard serial cables will not work.
Unless otherwise planned, customer is
responsible for ordering SCSI or
Fibre-Channel cables for tape drive
host connection.

Intentionally left blank.

Sun Internal and Approved Partners Only Page 3 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

PREPARATION CUSTOMER
Confirm site preparation has been Use the SL500 Systems Assurance
completed. Guide Checklist for preparing the site.
Power connection available.
Library Rack Installed.
Service Area Available.
LAN Cable for SL500 to StorageTek For connection to customer
Library Console connection. management host(s).

Network information for SLC. Use Tape Storage Specification


document if available at EIS website.
IP Address to be assigned or
DHCP
Subnet Mask
Gateway
Tape drive connections to host SCSI or Fibre-Channel cables for tape
drive host connection.

Sun Internal and Approved Partners Only Page 4 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

UNPACKING
Delivery complete?
Collect all licenses and software CDs. Store carefully!

Allow the system to acclimatise (power Refer to EIS standard Acclimatisation of


off) at the customer site. Sun Servers & Storage
Unpack outside data center to ensure no Collect packing material together for
contamination/dust is released inside disposal.
customer's controlled environment.
Verify all packing material has been Fans & air vents must be free to operate.
removed, i.e. nothing is blocked.
Collect documentation CDs. Give to customer during handover.

Request licences where required. For libraries running 1300 to 1373 code
the SILKS License files are initially
generated by the CSR and emailed
to those individuals entered in the SILKS
tool. If these license files are not available
they may be regenerated and emailed to
the installer using the SILKS tool using
URL
https://silks.central/silks/login.jsp using
your SUN Id and LDAP password.
The SILKS link is also available via
SunWeb A-Z Index.
Login, using SUN ID and LDAP.
Select appropriate library you want
the license for.
Fill out the rest of the information.
Select Search.

For libraries running 1395 and higher the


E-Delivery hardware activation files will
need to be downloaded by the customer.
An e-mail will be sent to the customer
pointing them to
https://edelivery.oracle.com/ where they
will have to give their info and then
browse the Oracle StorageTek Products
and then select Generic Platform.

NOTE: E-delivery hardware activation


files require SLC 4.75 or higher.

ASSEMBLY/CABLING/POWER-UP
Record library serial number. Located on the back of the base module.

Assure site survey has been conducted Use the SL500 Systems Assurance Guide
and physical requirements are satisfied Checklist for preparing the site.
(tile placement, service area hectic.)
Assemble the library according to the Use SL500 Installation Manual. See the
directions in the SL500 Installation obtain required manuals step of the
Preparation Field Installer section of
Manual, part 96114 Revision N. this checklist on page 2.

Sun Internal and Approved Partners Only Page 5 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check
Install any additional hardware options. Example: optional operator control panel.
Provide power to the library. Note that the customer's electrician is
responsible for connecting the power lines
to the in-house power grid. See
Customer Preparation Section of this
checklist on page 4.

Sun Internal and Approved Partners Only Page 6 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

FINAL PHYSICAL INSPECTION


Verify the front door key is available.
Verify cables are properly installed and seated.
Check that arrays are correctly seated.
Check that array targets are cleaned.
Verify retrieval of all service tools.
Locate all tools in the standard-issue tool kit. Locate optional tools.
Verify the barcode label on both sides of the robotic module.
OPTIONAL INSTALLATION OF StorageTek LIBRARY
CONSOLE (SLC)
Optionally, install StorageTek Library Check for latest version at:
Console on your laptop. https://dlrequest-zn-
dlapps1.sfbay.sun.com/usr/search
A Solaris version is available, typically used Search for SLC
for customer host installs, and should also be
Select the latest version
installed before the library if required.
Follow the SLConsole installation
instructions.

SLC should be loaded before the library is


installed. Recommend installation before
going to customer site.
Refer to the Installing StorageTek Library
Console section of the SL500 Installation
Manual.
Utilize the passwords received in the
Obtain SLC Activation Passwords section
of this checklist.

CONFIGURATION
Check the library's firmware through See the obtain the latest microcode step
the CLI or SLC. of the Preparation Field Installer
section of this checklist on page 2.
Upgrade code if necessary.
Refer to Appendix A of this checklist for
the firmware upgrade procedure.
Basic configuration. Follow the procedures in the
Configuration chapter of the SL500
Installation Manual. These procedures are
outlined in the steps below.
Configure network connections. Refer to the Network Configuration
Through CLI section.
Create and/or modify library and tape Refer to the Library and Tape Drive
drive configuration entries. Configuration Entries section.

Sun Internal and Approved Partners Only Page 7 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check
Install all SILKS/E-delivery Hardware Refer to the Unpacking section on
Activation files for this specific requesting Hardware Activation files. The
Hardware Activation files are best installed
machine. using SLC and selecting Tools ->
Hardware Activation. Follow the
instructions in the "SL500 Installation
Manual" for further details.
Alternatively, if SLC cannot be accessed,
Hardware Activation files may be installed
using the CLI instructions contained in the
SL500 Code Installation Instructions.
These instructions can be found at:
http://dlrequest.sfbay.sun.com:88/usr/login
SL500 code version 1300 or later and SLC
code version 4.10 or later must both be
installed first before any Hardware
Activation files can be installed.
Note: The E-Delivery Hardware
Activation files are to be downloaded by
the customer and should never be provided
by service.
Set tape drive cleaning parameters. Set to manual, or to auto-clean.
Auto-clean requires a slot designated
and reserved for the cleaning
cartridge.
Manual allows administrators to place
the cleaning cartridge in the CAP or in
a customer slot.
When you use a cleaning cartridge in
a customer slot the label should be the
CLN.... and the drive identifier L1, L2
L3 and should be configured in the
Backup software as cleaning
cartridge. In the reserved slot you
have the universal cartridge identifier
(CU).
Record the configuration. Use the worksheet in the Recording the
Configuration Section of the SL500
Installation Manual.
Create drawings and record SCSI target For SCSI attached drives, refer to your
IDs or dynamic WWNs. drives installation manual for setting
the SCSI targets.
Fibre Channel drives will have a
dynamic WWN assigned by the
library.

Sun Internal and Approved Partners Only Page 8 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

MANAGEMENT HOST CONNECTION


Management and Backup servers. Refer to planning documents for your
particular host environment and network
topology (SDP, SLC, and ACSLS
managements hosts reside in this
connection).

HOST DRIVE CONNECTION (Solaris host only)


Connect drives. Refer to the Sun StorageTek SL500
Installation guide, available at:
http://download-
adc.oracle.com/archive/cd_ns/E21115_01/
Ensure that the latest driver patches are If host has been freshly installed using a
installed: recent EIS-DVD then the system will have
been correctly patched.
If adding storage to an existing host ensure
that latest versions of following patches are
installed as appropriate:
Minimum Solaris requirement:
Solaris 10 5/08 also known as Update
5.
Test access to the installed tape drives Solaris:
and library management. from the boot PROM ok prompt:
probe-scsi-all, note and record output
CAUTION: This is an offline test. assuring all installed drives appear.
OS level testing can be accomplished
with the mt command, for example:
# mt -f /dev/rmt/<dev-file> status
Update the tape drive firmware if Current patches are available at:
necessary. http://let47.central.sun.com/pmwiki/pmwik
i.php?n=Main.FirmwareLevels
Click on the link for the correct patch
Login to MOS and download the patch
Refer to the SL500 Installation
Manual and service reference manual
for your specific drive type.

Sun Internal and Approved Partners Only Page 9 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

VERIFY SERVICEABLE INSTALLATION


FINAL CHECKS
Run the checkout series of tests by Refer to the Checkout chapter of the
connecting to the CLI port. SL500 Installation Guide:
Make sure a diagnostic cartridge with
the label DG is in a reserved slot.
Diagnostic self test.
Check that the lowest slot can be
accessed.
Run CAP diagnostic.
Run Door Diagnostics.
Run DEMO for 200 loop count.
Verify host connectivity.
Check that the green LED on the
service panel is blinking at a slow
repeat rate, if rapidly flashing the
library is configured incorrectly.
Collect library information, software Refer to the Checkout chapter of the
versions, and event logs through the SL500 Installation Guide:
CLI interface. Retain copies for your records:
capture logs via print logs all
command
lib getconfig
libstate print
version print
frameinfo print
drive all
drive <id> getconfig
network print
license print

Send logs to support. Reference the installation ticked opened


in the preparations steps.
If you are located in the US contact the
Technical Support team in Colorado for
e-mail or FTP delivery instructions.
The EIS Team has been unable to
ascertain if this facility is available
outside the US.

Sun Internal and Approved Partners Only Page 10 of 13 Vn 1.4 Created: 26 Jun 12
Task Comment Check

COMPLETE THE INSTALLATION


Create a block diagram for the customer to reference when calling support.
Send any documentation and diagrams
to your local service team designate for
storage of these files.
Complete Sun StorageTek SL500 Part Number: 96200 Revision D
Modular Library System Customer
Orientation Checklist with customer.
Perform Installation Assessment tests as EISdoc V4 completed during
described in the EIS Test Procedures preparation of installation.
Plan.
Complete documentation and hand over EISdoc V4:
to customer. File EIS-DOCS-Operational Handover-
Document.odt
Short briefing: the configuration.

Sun Internal and Approved Partners Only Page 11 of 13 Vn 1.4 Created: 26 Jun 12
Appendix A
Installing or upgrading firmware for the SL500 is a multi-step process, (which is both disruptive and
non-disruptive) and requires additional software called .putty. and .pscp. versions 0.55 or higher.
These programs are available at:
http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html
Note: The following procedure uses the Ethernet connection to the library.
You can also load code using the command line interface, but it takes 50 minutes or more to
complete.

Step 1: Non-Disruptive
Getting the Files
1. Make a new folder on your local workstation or laptop and name it SL500 Code, add a version
level if you want.
2. Place copies of the additional software (putty and pscp) into this folder.
3. Log in to the Uniform Software Repository (USR) to download the new code at:
https://dlrequest-zn-dlapps1.sfbay.sun.com/usr/search
4. Using the web browser, download the file to your local workstation or laptop by clicking on the
file name (such as verde.tgz).
Do not unzip the file.
Important:
You must obtain a new activation password even if previously configured.
Transferring the Files
1. Make sure you can communicate with the library over Ethernet:
Open a Command Prompt: Start Run CMD
Ping the library, enter: ping <library IP address>
2. 2. In the Command Prompt window
Change directory to the new folder with the 3 files (code, putty, pscp) such as: cd c:\SL500
Code\1.07
Enter:
pscp scp code-name.tgz dnld@<library IP address>:
Note: The command must end with a colon (:).
You will see the changing status of the download (percentage complete).

Step 2: Disruptive
1. After the transfer is complete, run the putty application.
In the Command Prompt window, enter: putty <library IP address>
A remote window opens.
2. In the remote window, Log in using the following:
Login: dnld
Password: d0wnl0ad (using zero.s instead of the letter o).
Warning: Do not open the library door, power-off, or interrupt the library while
downloading code. This will permanently damage the RLC card (library controller).
This process takes approximately 3 to 5 minutes. The remote window closes (Connection
closed by remote host.) upon completion.
3. Messages appear on the screen such as:
File download / Install Utility
Do you want to install this image?
Respond: yes
Extracting files . . .
Installing files . . .
4. Power-off the library, wait 15 seconds, then power-on the library. You can do this while still
connected to the library.
5. After the power-on reset and the library initializes, start putty.
In the Command Prompt window, enter: putty
6. Complete the PuTTY configuration screen.
Enter the library IP address or name in the Host Name and Saved Sessions windows.
7. Click Never, then click Open.
8. In the new Command Prompt window, enter:
Login: service
Password (Activation): <new activation password>
A message indicates your password has expired, enter new password.
Enter a new password for service. This is the account password for the service

Sun Internal and Approved Partners Only Page 12 of 13 Vn 1.4 Created: 26 Jun 12
Appendix A
representatives. Make sure you use the service password for service operations.
9. Enter: version print
Library Vendor:
Library Model:
Serial Number:
Interface:
Firmware:
10. Verify the information is correct.
11. Enter: reboot
12. Clean-up and return the library to the customer for use.

Copies of the checklists are available on the EIS web pages or on the EIS-DVD. We recommend that
you always check the web pages for the latest version.

Comments & RFEs welcome. Oracle staff should mail to EIS-SUPPORT_WW_GRP@oracle.com .


Partners should mail to: SUPPORT-PARTNER-QUESTIONS_WW_GRP@oracle.com .

Sun Internal and Approved Partners Only Page 13 of 13 Vn 1.4 Created: 26 Jun 12