Vous êtes sur la page 1sur 1

DIgSILENT

abc
INVERSIONES
AGRICOLAS
OLMOS SAC
abc

13.14 MW
23.36 kV
5.91 Mvar
0.91
SET TIERRAS NUEVAS 23 KV
1.02 p.u.
0.00 deg
1.40 MW
0.87 M..

3.10 MW
SISTEMA DE UTILIZACION EN MT 22.9 KV

AAAC 3-1x120 mm2 1.92 M..

-0.00 ..
-1.29 ..
AGROLMOS

abc

abc
ST-1

13.14 MW
5.91 Mvar
SAC
90.64 %
AGRICOLA PAMPA BAJA
N2XSY 3-1x120 MM2

3.40 km
abc
abc
0.13 km
abc

AAAC 3-1x240 mm2 4.55 MW


AAAC 3-1x120 mm2 AAAC 3-1x120 mm2 0.00 MW
9.10 km 1.57 Mvar 4.95 km 9.15 km -0.73 ..

1.98 Mvar
13.13 MW
5.90 Mvar

1.55 Mvar
abc

12.58 MW
4.41 Mvar

5.73 MW
2.84 Mvar

49.59 %

2.50 MW
abc
63.61 %

37.85 % abc

90.64 %

8.02 MW

66.91 %
abc AGROVISION
21.60 kV 2.05 MW

AAAC 3-1x120 mm2


0.94 p.u.
-4.90 deg
0.54 Mvar SAC
17.35 %

AAAC 3-1x..
AAAC 3-1x120 mm2

1.90 km
N2XSY 3-1x120 MM2

16.05 km
0.07 km 2.60 km

abc

1.24 Mvar
2.00 MW
abc

abc
abc 2.01 MW
-2.97 MW 0.53 Mvar abc PLANTACIONES
-0.82 Mvar 18.10 % 0.00 MW
26.85 % -0.72 .. EL SOL

1.24 Mvar
INVERSIONES Y

2.00 MW

0.00 MW
-0.77 ..
19.50 kV

abc
abc
0.85 p.u.
SERVICIOS -9.07 deg PTO CONEXION abc
FABRI SAC 0.97 MW
0.28 Mvar

-9.08 deg
19.50 kV
0.85 p.u.
12.66 %
125 KVA

0.03 Mvar
0.04 MW

0.03 Mvar

0.02 Mvar
0.00 MW

0.04 MW

0.04 MW
0.72 %

44.72 %
-0.36 ..
abc

abc
0.92 MW

SAB1
0.62 Mvar
14.01 %

-9.09 deg
19.46 kV
0.85 p.u.

0.07 Mvar

0.06 Mvar
0.10 MW

0.10 MW
56.18 %

abc
0.13 Mvar
0.20 MW

3.63 %
250 KVA

SAB2
0.72 MW

0.07 Mvar

0.06 Mvar
0.10 MW

0.10 MW
56.18 %
0.49 Mvar
11.00 %

abc
250 KVA

-9.10 deg
19.39 kV
0.85 p.u.

0.11 Mvar

0.10 Mvar
0.16 MW

0.16 MW
91.06 %

abc
0.21 Mvar
0.32 MW

5.89 %
Load Flow Balanced 250 KVA
0.40 MW
Nodes Branches 0.27 Mvar

-9.11 deg
19.36 kV
0.85 p.u.

SAB3
6.12 %

0.11 Mvar
0.16 MW

0.16 MW
91.06 %

0.10 M..
Line-Line Voltage, Magnitude [kV] Active Power [MW]

abc
0.05 Mvar
0.08 MW

0.08 MW
91.19 %

91.19 %

0.08 MW
Voltage, Magnitude [p.u.] Reactive Power [Mvar]
0.05 M..

0.05 M..
-0.08 ..
-0.05 ..

1.47 %
abc

250 KVA
Voltage, Angle [deg] Loading [%]
0.32 MW
SAB4

125 KVA 0.22 Mvar

0.11 Mvar

0.10 Mvar
0.16 MW

0.16 MW
91.23 %
-9.11 deg
4.89 %

19.35 kV
0.85 p.u.

abc
250 KVA

0.21 Mvar
0.32 MW

5.90 %
19.35 kV
0.85 p.u.

0.11 Mvar

0.10 Mvar
0.16 MW

0.16 MW
91.23 %
-9.11 deg

SAB5

abc
250 KVA

Estudio de Coordinaciones de Protecciones Project: Ing CCO


COELVISAC
Sistema de utilizacin en 22.9 kV Pampa Baja Graphic: RED UTIL. PAM
Clculo de Cortocircuito Monofsico a Tierra Date: 5/27/2015
PowerFactory 14.1.3 Annex: