Pruebas y Ajustes
120M, 140M and 160M Motor Graders All Wheel Drive Electronic Control System
Nmero de medio -RENR9084-02 Fecha de publicacin -01/12/2007 Fecha de actualizacin -19/12/2007
i02707463
Using Messenger
1. Start the machine.
2. Locate the readings for the speed of the motor with the Messenger display. The readings for the
speed of the motor are listed under "System Parameters / AWD".
4. Activate "CREEP" mode. Leave the "FNR" switch in the NEUTRAL position. With the command
for wheel speed at zero, verify that both front wheels are not spinning. Verify that both speed
sensors read zero.
5. Select the forward direction. Select maximum "CREEP" speed. Ensure that the steering and the
articulation are straight ahead. Both front wheels should spin in the forward direction. The motor
speeds should be positive. The speeds for the motors should be approximately 920 50 RPM.
6. Select the reverse direction. Maintain maximum "CREEP" speed. Ensure that the steering and the
articulation are straight ahead. Both front wheels should spin in the reverse direction. The motor
speeds should be negative. The speeds for the motors should be approximately 920 50 RPM.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 07/01/2008
140M Motor Grader B9D00001-UP (MACHINE) POWERED BY C7 Engine(SEBP49... Pgina 2 de 4
1. Start the machine. Engine speed should be set to low idle (approximately 800 RPM).
2. Open Cat ET. Select the AWD ECM. Navigate to the "Override" screen.
Illustration 1 g01358394
3. Override the "Left Front Drive Pump Forward Control Solenoid Current Percentage Override"
command to 100%.
4. The left motor speed should display a positive value. The left motor speed should be
approximately 615 20 RPM. The values should be positive with a forward command.
Illustration 2 g01358451
5. Override the "Right Front Drive Pump Forward Control Solenoid Current Percentage Override"
command to 100 percent.
6. The right motor speed should display a positive value. The right motor speed should be
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 07/01/2008
140M Motor Grader B9D00001-UP (MACHINE) POWERED BY C7 Engine(SEBP49... Pgina 3 de 4
approximately 615 20 RPM. The values should be positive with a forward command.
Illustration 3 g01359183
8. Override the "Left Front Drive Pump Reverse Control Solenoid Current Percentage Override"
command to 100 percent.
9. The left motor speed should display a negative value. The left motor speed should be
approximately 615 20 RPM. The values should be negative with a reverse command.
Illustration 4 g01359179
10. Override the "Right Front Drive Pump Reverse Control Solenoid Current Percentage Override"
command to 100 percent.
11. The right motor speed should display a negative value. The right motor speed should be
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisw... 07/01/2008
140M Motor Grader B9D00001-UP (MACHINE) POWERED BY C7 Engine(SEBP49... Pgina 4 de 4
approximately 615 20 RPM. the values should be negative with a reverse command.
Diagnostics
The right speed increases when the command for the left pump is changed.
{ the hydraulic line that is routed between the pump and the motors
The speed displayed positive values for both the forward and the reverse direction.
2. The speed sensor could have failed. There could be an open circuit in either one of the two signal
wires.
The speed displayed positive values for the reverse direction and negative values for
the forward direction.
{ The hydraulic lines that are routed between the pumps and the motors