Académique Documents
Professionnel Documents
Culture Documents
2
Flooding and pollution
The problem
Flooding is an issue that needs no Much of the onus to comply
introduction in the UK. with the FWM Act falls on Local
Authorities whose role it is to
Pluvial ooding has become a
mitigate and minimise both ood
regular occurrence as our drainage
and pollution risk by ensuring
networks become incapable of
that hard-lansdcaping design
coping with increased urbanisation
and installation design-out
combined with climate change.
and build-out both ood risk
Since the turn of the millennium, the and pollution risk, usually by
construction industry has sought to employing SuDs techniques.
tackle the problems associated with
more intensive rainfall, and in The solution
particular the volumes of water Stormwater Management
generated. Limited offer the highly innovative
and proven D-Rainclean porous
This culminated in the Flood and channel and bio-retention lter
Water Management Act 2010, media system that treats the
which sets out the responsibilities priority pollutants identied by
for the design, construction, and the regulatory authorities
maintenance of sustainable (Environment Agency and
drainage systems. Highways Authority), principally
What is perhaps less well known is total suspended solids (TSS) and
that, enshrined in this legislation, is dissolved heavy metals such as
the requirement to address surface copper and zinc meeting both
water quality leaving development these key requirements within a
sites in order to comply with the single solution.
Water Framework Directive.
3
D-Rainclean
The solution
D-Rainclean comprises a 300mm Cover options A Filter media D
polypropylene channel system D-Rainclean can be covered by either This unique engineered bio-retention
filled with a unique engineered ush or raised cast iron grill sections, mixture lies at the heart of the
bio-retention filter media that treats suitable for heavily trafcked areas. D-Rainclean system.
run-off from any impermeable The D400 cast iron cover can support
surface. Surface water owing from
HGV trafc. D-Rainclean can also be
impermeable areas contaminated
Using the processes of separation, left open to allow for vegetation growth
with pollutants passes through the
adsorbtion, absorption, and at car park borders and similar areas.
D-Rainclean lter media layer where it
bioremediation D-Rainclean allows B is treated before being discharged
contaminated run-off to be treated to Bulkheads
through the base holes.
a sufficient quality to allow infiltration Built in to the channels section at
back into the ground at the closest 500mm intervals, these ensure The remarkable levels of performance
point to its generation, meeting one dimensional stability and more are due to selected natural minerals
of the key requirements in drainage importantly, limit pollution spillages to with a high exchange capacity and
hierarchy source control. a conned section of the system. ltration efciencies. Diffuse
hydrocarbons (oil drops) emitted in
D-Rainclean uses a unique
engineered bio-retention filter Channel units C trafcked areas are virtually degraded.
An accidental oil spill of up to 10 litres
media containing selected natural Robust and durable 500mm length
can be retained within 1 linear metre of
minerals with a high cation exchange polypropylene sections have an
channel for up to 24 hours.
and filtration capacity. These media integrated bulkhead at mid point
clean surface water as it passes (250mm from either end). Each Full details of the lter-media are
through the filter layers, degrading mid-section has 8 apertures in its shown on pages 6-7.
and diffusing hydrocarbons, and base to allow the controlled inltration
dissolved heavy metal like copper of ltered water into the sub-base. Controlled, E
and zinc. pollution-free water
A properly installed D-Rainclean
system can drain areas of up to
one hectare and the system has
been proven to meet the stringent
requirements set down by the DIBt.
Components
& accessories
The D-Rainclean system contains an
extensive range of components and
accessories allowing designers
to achieve a broad spectrum
of project criteria.
4
A
End piece Emergency Cast-iron cover Cast-iron cover Tools and clips
Can be used for left overflow unit Class B125 Class D400 Wrench
or right hand ends With 110mm socket Includes cast iron Includes cast-iron Code: DRFC011
Dimensions: connections for left frame. Connection frame and child Security bolts:
250 x 400 x 366mm or right hand clamps need to be safeguard Code DRFC010
Code: RH: DRFC002 Dimensions: ordered separately Code: DRFC009 Joint Clamps
LH: DRFC003 500 x 400 x 366mm Includes child Code: DRFC008
Code: DRFC004 safeguard Aluminium rails
Code: DRFC007 Code: DRFC012
5
Filter media
D-Rainclean Filter Media is a unique series of media that perform different
functions in order to clean surface water runoff using the processes of
filtration, adsorption, ion exchange, phosphate and retention.
50 g/l
de-icing will have an effect on overall
Chromium (Cr)
50 g/l
service life see Design life on page 7.
Copper (Cu)
Nickel (Ni) 50 g/l
Mercury (Hg) 1 g/l
Zinc (Zn) 500 g/l
* Ground Water according to German Federal Soil
Absorption area/exchanger A Conservation Law (Bundesbodenschutzgesetz)
Water storage/lter B
Organic matrix/settlement area C
pH-buffer area/acid limiter D
Components pictured schematically grain size not to scale.
6
Oil bonding and
degradation Planting
The large void space within the media The lter media contains sufcient nutrients for
allows oil to lose its uidity and cover selected plants e.g. pachysandra, mahonia,
the pore space where micro vinca minor or cotoneaster. For further
organisms can degrade it. In the event information please contact the Stormwater
of accidental spillage the internal Management technical department.
bafes within the D-Rainclean channel
design ensure that 10 litres of oil per
linear metre can be retained for up to
24 hours so that it can be removed,
professionally disposed, and the
media replaced.
Phosphate bonding
The enhanced adsorption capacity
within the lter media is crucial to
maintaining clean water courses.
pH Value
The carbonate buffer range of the
media is above pH 7.2
Design life
The design life of the D-Rainclean
lter media is a function of its daily
use. The Filter media has been tested
to DIBt standard approval and based
on applications since 2002.
Design life of D-Rainclean filter
media**
20
15
Duration/years
10
5000-15000 DTV
300-5000 DTV
300 DTV
0
Light Average Heavy
impact impact impact
Disposal
The lter media should be removed
and disposed in line with local
authority and regulatory guidelines.
7
Component and installation details
Stormwater Management provide technical support from concept The B125 Cast-iron grate is ideal for occasionally or constantly
design right through to the construction phase. We are able to offer light trafficked areas.
site specic design solutions to provide our clients with the most
The D400 cast-iron grate and frame is suitable for heavier
cost effective and environmentally sympathetic solutions. Our
trafficked areas and heavy goods vehicles.
engineering department can provide preliminary calculations and
CAD details.
60
500
366
Filter-
Approx. 414
media
200
400
D-Rainclean open
Filter media
360
50mm of 2-5 or 3-8mm gravel
300 390 0-32mm crushed stone
10 310
382
360
360
53
FUNKE
B125 DIN EN 1433
Approx. 500
Approx. 414
D - RAINCLEAN
Filter-
200 media 366
200
OPEN
400
Filter media
D-Rainclean cast-iron class B125
50mm of 2-5 or 3-8mm gravel
Top view
510
360
EN 1433
140
D - RAINCLEAN
Approx. 500
Approx. 470
GRUPPE
PAM D 400
Filter-
200
FUNKE
media
400
70 125
60
366 500
110
105
400
8
Anchoring pins for Expansion joint
high trafc loading
C20/25 Concrete
360
Approx. 470
C20/25 Concrete
360
200 Filter-media
Approx. 470
D-Rainclean cast-iron class D400 D-Rainclean Class D with perforated drain pipe
The D-Rainclean lter channel has a D400 cast iron cover Combination with a perforated, high strength carrier pipe allows the
and frame (500mm 360mm) is particularly suitable for use D-Rainclean System to be installed in soils with low water
in trafcked areas. permeability.
Expansion joint
Anchoring pins for Anchoring pins for
high trafc loading high trafc loading
Expansion joint C20/25 Concrete 360
C20/25 Concrete
360
Approx. 470
Approx. 470
Filter
media
200
200 Filter-media
Gravel soakaway
with drainage pipe
Gravel soakaway
or geocellular unit
with drainage pipe
hR
or geocellular unit
hR
bR
bR 50mm 2-5mm or 200-300
200-300
3-8mm clean gravel Ev2 45 MN/m2
50mm 2-5mm or 3-8mm clean gravel
Ev2 45 MN/m2 Road construction depth depends on loading
D-Rainclean Class D abutting kerb with perforated Overflow detail for exceedence events
drain pipe The 110mm overow pipe connects to a perforated high strength
Combination with a perforated, high strength carrier pipe allows the carrier pipe in a trench drain.
D-Rainclean System to be installed in soils with low water
permeability.
9
Sizing the system
The D-Rainclean system can be
sized by our engineering team
if the following information is
provided:
Location of project
Design rainfall event
Soil infiltration coefficient
at the required location
Drainage catchment area
Surface material type
Allowable discharge rate
Groundwater level
Available area for channel
system
Receiving water body
e.g. ground, watercourse, etc.
From this data our engineers Worked example for a Using DWA138 method of sizing,
this equates to 55m of D-Rainclean
will be able to calculate the car park in Witley, Surrey.
channel being needed, in the above
quantity of channel required The above car park has an
example, 27.5m has been designed
and where necessary, design in impermeable area of 900m2 with 38
using a trafcable B125 cast-iron
car spaces. With a run off coefcient
exceedence measures to meet grating, and 27.5m in an open channel
of 0.66 this equates to an effective
the rainfall design criteria. design adjacent to a landscaped area.
drainage area of 590m2. Using the
rainfall data for Witley, Surrey: Not only will the D-Rainclean channel
hydraulically control and treat the
N= 0.2 a = 5 year storm event
-1
runoff it also negates the need for
The D-Rainclean lter media has an positive drainage, silt traps, oil
inltration coefcient of 9 x 10-4, and it separator and ow control.
is assumed that the natural soil has the
same coefcient.
10
Stormwater Management Ltd are specialists in the design, supply and install of
surface water and sustainable drainage systems, whether the requirement is for
landscaped, hybrid or more engineered drainage systems Stormwater
Management Ltd are able to offer a solution.
This brochure is produced to give an example of the products we supply and how, subject to your own testing, our products may be used. Nothing in this brochure shall be construed so as to make any ascertain or
give any warranty as to the tness for purpose of any of our products in respect of any specic job. You should satisfy yourself through your own testing as to the suitability of our products for any specic purpose
and rely solely on such testing and/or the advice of any professional(s) you commission. While we ensure as far as is possible that all information given in this brochure is accurate at the time of print, information and
examples given in this brochure are by way of illustration only and nothing contained in this or any other promotional literature produced by us shall in any way constitute an offer or contract with you or shall be relied
upon by you as a statement or representation of fact.
11
Maintenance
Replacing the filter-media Technical
Where required use the installation
wrench open the cast iron cover of the
This will ensure that the substructure
gravel remains in situ. Support
D-Rainclean ltration channel.
Pour the new lter media into the Stormwater Management
Remove the lter media using a channel. This requires four standard design service
standard suction and rinsing vehicle. bags per metre of channel. Stormwater Management provide
A 1.5m3 bag is sufcient for approx. full technical support from design
Carefully remove lter media using right through to installation and
27 linear metres of channel.
suction hose. A weak water jet can commissioning from product
be used in order to accelerate the When laying the media, ensure that it and system selection, design
process if desired. is evenly spread along the channel to calculations and CAD drawings,
a depth of 200mm. we aim to provide clients with all
Continue removing the media until
the openings on the lower edge of the Once completed, replace the cast the relevant technical information.
ltration channel are visible. iron gratings in their frames and lock Whether your scheme uses soft,
in place. engineered or hybrid drainage
systems Stormwater Management
have a range of product and system
solutions to allow you to meet your
On site support
Stormwater Management Ltd. now
boasts the largest product range of
its kind in the UK. Fully conversant
in all D-Rainclean solutions as well
as other associated products, our
well- trained staff are always
available to discuss the technical
merits of D-Rainclean and to advise
which solution would be most
suited to a particular application.