Vous êtes sur la page 1sur 1

PREAMBLE

The schedule of Dimensions for Standard Gauge Corridor has been prepared
based on following factors:

1. The kinematic envelope and other infringements have been calculated for the
3200mm wide and 4048 mm high rolling stock, based on the kinematic
envelope calculations. The track and vehicle maintenance shall conform to
the clearances indicated therein during the period these stocks are in
operation.

2. The clearances are based on assumption that windows are sealed and doors
are closed during movement

3. Track shall be maintained to the tolerances taken for calculation of Kinematic


Envelope.

4. The Structure Gauge indicated in SOD shall not be violated under any
circumstances except for designated railway operational structures.
Designated railway operational structures include platform coping, platform
gates, hand railing in back-of-house platform edge, Track Access Gates.

5. The Kinematic Envelope(s) indicated in SOD shall not be violated under any
circumstance.

6. The vehicle Kinematic Envelope for the platform area shall be applied only
within confines of stations up to 80 Kmph vehicle speed for underground and
70 Kmph for elevated/At grade sections. At all other location, the Kinematic
envelope corresponding to 85 kmph vehicle speed shall be used for
determining the Structure Gauge and electrical clearances.

7. The maximum operating speed shall be 85 kmph.

8. The SOD is applicable for Ballastless track on main line and


ballasted/ballastless track in Depots.

9. No vertical curve shall be provided on the platform portion.

Vous aimerez peut-être aussi