TABLE: Concrete Joint Summary - ACI 318-08

(6/5) Beam/Column Capacity Ratio


TITULO C.21.3.6.2 NSR-10 ECUACIN C.21.4
(COLUMNA FUERTE - VIGA DBIL)
Mnc 1.2Mnb
0.833 Mnb/Mnc
Design B/C Major B/C Minor
Story Label Unique Name
Section Ratio Ratio
Story2 C1 115 C 30X30 0.308 0.784
Story2 C2 120 C 30X30 0.218 0.696
Story2 C3 121 C 30X30 0.499 0.568
Story2 C4 122 C 30X30 0.502 0.453
Story2 C5 123 C 30X30 0.762 0.673
Story2 C6 124 C 30X30 0.617 0.603
Story2 C7 126 C 30X30 0.469 0.452
Story2 C8 125 C 30X30 0.263 0.526
Story2 C9 118 C 30X30 0.458 0.72
Story2 C10 119 C 30X30 0.55 0.612
Story2 C11 116 C 30X30 0.634 0.714
Story2 C12 117 C 30X30 0.394 0.778
Story1 C1 103 C 30X30 0.300 0.698
Story1 C2 108 C 30X30 0.169 0.944
Story1 C3 109 C 30X30 0.203 0.802
Story1 C4 110 C 30X30 0.481 0.368
Story1 C5 111 C 30X30 0.306 0.370
Story1 C6 112 C 30X30 0.177 0.404
Story1 C7 114 C 30X30 0.297 0.803
Story1 C8 70 C 30X30 0.721 0.765
Story1 C9 106 C 30X30 0.456 0.742
Story1 C10 107 C 30X30 0.343 0.795
Story1 C11 104 C 30X30 0.471 0.639
Story1 C12 105 C 30X30 0.325 0.646