FW PUMP (DIESEL) - 5049-P-0003 A/B

Document No. Rev:


Design of Pump foundation Originator:
(for Dynamic loading) Checker:

FW PUMP (DIESEL) - 5049-P-0003 A/B

1. LOAD DATA:
Weight of Pump = 1002 kg 9.827
Weight of Driver = 1769 kg 17.349
Weight of Controller = 90 kg 0.883
Weight of Batteries = 182 kg 1.785
Weight of Base plate = 1324 kg 12.984
Weight of Enclosure = 680 kg 6.669
Total Static load for foundation = 5047 kg 49.496
Type of Design = Dynamic design as per Spec
Rotating speed of the Motor = 1500 rpm
No of cycles = 50
Power transmitted by Motor Ps = 522 kW

Dynamic load data @ each Anchor bolt locations


F1
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = 9.2 kN
F2
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = 9.2 kN
F3
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = 9.2 kN
F4
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = 9.2 kN
F5
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
Vertical load z = -1.5 kN

F6
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = -1.5 kN
F7
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = -1.5 kN
F8
Horizontal load (along length) x = 0 kN
Horizontal load (along width) y = 9.9 kN
Vertical load z = -1.5 kN
Size of Pump (in plan)
Length of Pump = 5.030 m
Width of Pump = 2.440 m
Height of Pump = 3.160 m

2. INPUT DATA:
Grade of concrete = C35
Grade of steel = Fe414
Characteristic compressive strength of concrete, fc' = 35 N/mm2
Characteristic yield strength of steel, fy = 414 N/mm2
Density of the reinforced concrete, gc = 23.5 kN/m3
Block
Length of Block = 5.800 m
Width of Block = 3.100 m
Height of Block = 1.800 m
Total Volume of Block = 32.364 m3
Weight of Block = 760.554 kN
Mass of Block = 77.528 kN sec2 / m
Clear Cover to Reinforcement = 75 mm
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
Diameter of bar used - Top & Bottom = 25 mm
Diameter of bar used - Side = 16 mm

3. SOIL DATA:
Allowable Safe Bearing Capacity of Soil, Net SBC = 150.00 kN/m2
Dynamic shear modulus = 3470000 kN/m2
Coefficient of Elastic uniform Compression Cz = 30000 kN/m3

Coefficient of Elastic Non-uniform Compression (2*Cz) Cq = 60000 kN/m3


Coefficient of Elastic uniform Shear (0.5*Cz) Ct = 15000 kN/m3
Coefficient of Elastic Non-uniform Shear (0.75*Cz) Cy = 22500 kN/m3
Poisson's ratio m = 0.4
Density of soil g = 18 kN/m3

Pump

Base plate

Anchor Bolt

F1/F5 F2/F6 F3/F7 F4/F8 Foundation Block F5

Z Z

X Along Length Y Along Width

4. Analysis Description
4.1 Stiffness check
Area of Horizontal contact surface between Af = 5.8 x 3.1
foundation & Soil = 17.980 m2
Second Moment of contact area about Ix = 5.8 x 3.1^3 /12
horizontal X axis passing through the centroid of
the base = 14.399 m4
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
Second Moment of contact area about Iy = 3.1 x 5.8^3 /12
horizontal Y axis passing through the centroid of
the base = 50.404 m4
Second Moment of contact area about Iz = 14.4 + 50.4
horizontal Z axis passing through the centroid of
the base = 64.803 m4

4.1.1 Spring stiffness of Elastic support


Vertical stiffness Kz = Cz Af
= 30000 x 17.98
= 539400 kN/m
Horizontal stiffness Kx (or) Ky = Ct Af
= 15000 x 17.98

= 269700 kN/m
Rocking / Pitching stiffness KX = Cq Ix
= 60000 x 14.399
= 863939 kN.m
KY = Cq Iy
= 60000 x 50.404
= 3024236 kN.m
Twisting / Yawing stiffness K = Cy Iz
= 22500 x 64.803
= 1458065.625 kN.m

4.2 Frequency Calculation


4.2.1 Frequency of Machine
Circular frequency of Motor m = 1500 x 2 pi() / 60
= 157.080 rad/sec

The ratio between the frequency of Machine at operaing speed and the natural
frequency of the Foundation should not lie in the range of 0.35 to 1.5 as per DGS

Preferred resonance frequency of foundation = 157.08 / 0.35


should be above = 448.799 rad/sec
Preferred resonance frequency of foundation = 157.08 / 1.5
should be below = 104.720 rad/sec
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:

4.2.2 Natural Frequency of Foundation


a. Uncoupled Vertical frequency n = Kz / m
= (539400 / 88.484)
= 78.077 rad/sec
Hence SAFE

b. Uncoupled Twisting frequency about Z axis nz = K / z


= (1458065.625 / 3605.572)
= 20.110 rad/sec
Hence SAFE

c. Uncoupled natural Frequencies in XZ Plane


pure Sliding x = Kx / m
= (269700 / 88.484)

= 55.209 rad/sec
Hence SAFE

pure Rocking y = (Ky - W Z) / oy


= (( 3024236 - 868.025 x 0.976) / 3162.2
= 30.920 rad/sec
Hence SAFE

d. Coupled natural frequencies


n1 = (x2 + y2 + ((x2 + y2)2 - 4 y x2 y2))
2 y
= Sqrt (55.209^2 + 30.92^2) + Sqrt ((55.20
30.92^2)^2 - 4 x 0.977 x 55.209^2 x 30.9
2 x 0.977
= 56.130 rad/sec
Hence SAFE

n2 = (x2 + y2 - ((x2 + y2)2 - 4 y x2 y2))


2 y
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
= Sqrt (55.209^2 + 30.92^2) - Sqrt ((55.209
30.92^2)^2 - 4 x 0.977 x 55.209 x 30.92^
2 x 0.977
= 54.327 rad/sec
Hence SAFE

e. Uncoupled natural Frequencies in YZ Plane


pure Sliding y = Ky / m
= (269700 / 88.484)
= 55.209 rad/sec
Hence SAFE

pure Rocking x = (Kx - W Z) / ox


= (( 863939 - 868.025 x 0.976) / 1785.29
= 21.987 rad/sec
Hence SAFE

f. Coupled natural frequencies


n3 = (y2 + x2 + ((y2 + x2)2 - 4 y y2 x2))
2 x
= Sqrt (55.209^2 + 21.987^2) + Sqrt ((55.2
21.987^2)^2 - 4 x 0.96 x 55.209^2 x 21.9
2 x 0.96
= 56.563 rad/sec
Hence SAFE

n4 = (y2 + x2 - ((y2 + x2)2 - 4 y y2 x2))


2 x
= Sqrt (55.209^2 + 21.987^2) - Sqrt ((55.20
21.987^2)^2 - 4 x 0.96 x 55.209 x 21.987
2 x 0.96
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
= 47.736 rad/sec
Hence SAFE

5. DESIGN DESCRIPTION
5.1 Dead load
Dead load of Equipment = 49.496 kN
Dead load of foundation = 760.554 kN
Total Dead load = 810.050 kN

5.1.1 Mass Ratio of foundation to Equipment weight = 760.554 / 49.495929


= 15.366 %
> 3% as per Spec
Hence O.k

5.2 Wind load


Basic Wind Speed (3 second gust) V = 175 km/h
= 48.6 m/s
Code = IBC
Wind Exposure Category Exposure = C
Importance Factor I = 1.15
Occupancy Category = III
For design of tank heating system = 5 m/s
Directionality factor Kd = 0.85

Topographic factor Kzt = 1


Gust effect factor G = 0.85
Force coefficient Cf = 2
Height above ground level (0 - 4.6m) z = 0.85 Table 6-2 of ASCE7 '
zg = 274.320 m Table 6-2 of ASCE7 '
= 9.500 Table 6-2 of ASCE7 '

Exposure coefficient Kz = 2.01 (z/zg)2/


= 2.01 x (0.85 / 274.32)^(2/9.5)
= 0.596 Table 6-3 of ASCE7 '
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
Design wind pressure qz = 0.613 Kz Kzt Kd V I 2

= 0.613 x 0.6 x 1 x 0.85 x 48.6^2 x 1.15


= 843.081 N/m2

Wind load on Pump (X - along length) = 843.08/1000 x 5.03 x 3.16


= 13.401 kN
Wind load on Pump (Z - along width) = 843.08/1000 x 2.44 x 3.16
= 6.500 kN

Moment @ Base (X - along length)


Due to wind load on Pump = 6.5 x (1.58 + 1.8)
= 21.972 kN.m
Total Moment @ Base - X dir. = 21.972 kN.m

Moment @ Base (Z - along width)


Due to wind load on Pump = 13.401 x (1.58 + 1.8)
= 45.294 kN.m
Total Moment @ Base - Z dir. = 45.294 kN.m

5.3 Seismic load


Code = IBC
Zone = 1
Occupancy Category = III
Importance Factor I = 1.25
Mapped Spectral, Response Accelerations SS = 0.45 g
(g = acceleration due to gravity) S1 = 0.18 g
Fa = 1.2
Fv = 1.62

Seismic base shear V = Cs W


Seismic response coefficient Cs = SDS / (R/I)
SMS = Fa Ss
= 1.2 x 0.45
= 0.540
SDS = 2 /3 SMS
= 2 / 3 x 0.54
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
= 0.360
SM1 = Fv S1
= 1.62 x 0.18
= 0.292
SD1 = 2 /3 SM1
= 2 / 3 x 0.2916
= 0.194
R = 3

Cs = 0.36 / (3/1.25)
= 0.150
Seismic load of Pump V = 0.15 x 49.496
= 7.424 kN
Seismic load of Block V = 0.15 x 760.554
= 114.083 kN
Total Seismic load (X or Z) V = 121.507 kN

Moment @ Base
Due to Pump = 7.42 x (1.58 + 1.8)
= 25.094 kN.m
Due to Block = 114.0831 x 0.9
= 102.675 kN.m
Total Moment (X or Z) = 127.769 kN.m

5.4 Anchor Bolt design


Dia of Bolt = 20 mm
No. of Bolts = 8 nos.
Length of Bolt = 300 mm
Allowable Shear stress per Bolt Fv = 144.69 N/mm2
Allowable Tensile stress per Bolt Ft = 303.16 N/mm2
Allowable Bearing stress per Bolt Fu = 491.53 N/mm2

5.4.1 Shear Capacity of Bolt


Allowable Shear capacity per bolt = Ab Fv
= ( x 20 ^2 / 4) x 144.69
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
= 45.456 kN
Actual Shear force per Bolt > 15.188 kN
Hence O.k

5.4.2 Tension Capacity of Bolt


Allowable Tensile capacity per bolt = Ab Ft
= ( x 20 ^2 / 4) x 303.16
= 95.241 kN
Actual Tensile force per Bolt > 16.132 kN
Hence O.k

5.4.3 Bolt Subjected to Combined Shear & Tension


Combined Stress for Bolt = (15188.436 / x 20^2 / 4) / 144.69 +
(16132.478 / x 20^2 / 4) / 303.16
= 0.504
< 1.400
Hence O.k

5.4.4 Pullout test


Length required L = Sqrt (Apsf / 3.14)
Area of projected surface Apsf = T / 2 sqrt(fc')
= 16132.478 / (2 x 5.916)
= 1363.443 mm2
L = Sqrt (1363.443 / 3.14)
= 20.838 mm
< 300 mm
Hence O.k

5.5 Base pressure check


Total weight of footing on Soil = 810.050 kN
Area of Footing = 5.8 x 1.8
= 10.440 m2
Base pressure due to Vertical load = 810.05 / 10.44
= 77.591 kN/m2
Base pressure due to Wind load - X = 21.972 / (5.8 x 3.1^2 / 6)
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:

= 2.365 kN/m2
Base pressure due to Wind load - Z = 45.294 / (3.1 x 5.8^2 / 6)
= 2.606 kN/m2
Base pressure due to Seismic load = 127.769 / (5.8 x 3.1^2 / 6)
= 13.754 kN/m2
Total Base pressure = max (77.591 + 2.365, 77.591 + 2.606,
77.591 + 13.754)
= 91.345 kN/m2
< 112.500 kN/m2 = 150 x 0.75
Hence O.k

5.6 Stability check


5.6.1 Overturning
Total Vertical load = 810.050 kN
Moment about X = 64.399 kN.m
Moment about Z = 64.399 kN.m
Resultant Overturning moment = sqrt(64.399^2 + 64.399^2)
= 91.074 kN.m
Resisting moment = 810.05 x 3.1 / 2
= 1255.577 kN.m
Factor of Safety = Resisting moment / Overturning moment
= 1255.577 / 91.074
= 13.786
> 1.5
Hence SAFE

5.6.2 Sliding
Resultant Shear force Vt = fx2 + fz2
= Sqrt (64.399^2 + 64.399^2)
= 91.074 kN
Resisting Shear = 0.45 Pt
= 0.45 x 810.049929
= 364.522 kN
Factor of Safety = Resisting Shear / Resultant force
= 364.522 / 91.074
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
= 4.002
> 1.5
Hence SAFE

5.7 Block design


5.7.1 Reinforcement calculation - Top & Bottom
Factored Base pressure = 91.345 x 1.5
= 137.017 kN/m2
Factored moment (along X direction) = (137.017 x ((5.8 / 2)^2) / 2)
= 576.158 kN.m
Factored moment (along Z direction) = ((137.017 x ((3.1 / 2)^2) / 2)
= 164.592 kN.m
Consider width of Base b = 1000 mm
fy / 0.85 fc' W = 414 / (0.85 x 35)
= 13.920
(Mu / b x d2 x 0.85 fc') KU = 576.16x 10^6 / (1000 x 1725^2 x 0.85 x 3
= 0.007
Percentage of Steel required = 100 x min((1+(1-2.61 Ku))/W,(1+(1-2.6
= 100 x min((1 + sqrt(1 - 2.61 x 0.00651)) /
(1 - sqrt(1 - 2.61 x 0.00651)) / 13.92)
= 0.061 %
Area of steel required = 0.0613 x 1000 x 862.5 / 100
= 528.522 mm2
Check for Min. reinforcement = 0.18%bD
= 0.18 x 1000 x 900 / 100
= 1620.00 mm2
Area of one bar = 490.874 mm2
Spacing required = 1000 x 490.874 / 1620
= 303.01 mm
Spacing provided = 150 mm
Maximum spacing as per ACI-318 Cl:7.6.5 & Cl.12.2.4 in Sp = 400.00 mm

Provide T25 @ 150mm c/c both ways - Top


Provide T25 @ 150mm c/c both ways - Bottom
Provide T16 @ 150mm c/c both ways - Side
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. Rev:
Design of Pump foundation Originator:
(for Dynamic loading) Checker:
Rev: A1
Originator: RSD
Checker:

9.827 kN
17.349 kN
0.883 kN
1.785 kN
12.984 kN
6.669 kN
49.496 kN
as per Spec
Rev: A1
Originator: RSD
Checker:
Rev: A1
Originator: RSD
Checker:

F1

Along Width
Rev: A1
Originator: RSD
Checker:
Rev: A1
Originator: RSD
Checker:

(( 3024236 - 868.025 x 0.976) / 3162.287)

(x2 + y2 + ((x2 + y2)2 - 4 y x2 y2))

Sqrt (55.209^2 + 30.92^2) + Sqrt ((55.209^2 +


30.92^2)^2 - 4 x 0.977 x 55.209^2 x 30.92^2))

(x2 + y2 - ((x2 + y2)2 - 4 y x2 y2))


Rev: A1
Originator: RSD
Checker:
Sqrt (55.209^2 + 30.92^2) - Sqrt ((55.209^2 +
30.92^2)^2 - 4 x 0.977 x 55.209 x 30.92^2))

(( 863939 - 868.025 x 0.976) / 1785.298)

(y2 + x2 + ((y2 + x2)2 - 4 y y2 x2))

Sqrt (55.209^2 + 21.987^2) + Sqrt ((55.209^2 +


21.987^2)^2 - 4 x 0.96 x 55.209^2 x 21.987^2))

(y2 + x2 - ((y2 + x2)2 - 4 y y2 x2))

Sqrt (55.209^2 + 21.987^2) - Sqrt ((55.209^2 +


21.987^2)^2 - 4 x 0.96 x 55.209 x 21.987^2))
Rev: A1
Originator: RSD
Checker:

as per Spec

Table 6-2 of ASCE7 '05


Table 6-2 of ASCE7 '05
Table 6-2 of ASCE7 '05

Table 6-3 of ASCE7 '05


Rev: A1
Originator: RSD
Checker:

0.613 x 0.6 x 1 x 0.85 x 48.6^2 x 1.15


Rev: A1
Originator: RSD
Checker:
Rev: A1
Originator: RSD
Checker:

(15188.436 / x 20^2 / 4) / 144.69 +


(16132.478 / x 20^2 / 4) / 303.16
Rev: A1
Originator: RSD
Checker:

max (77.591 + 2.365, 77.591 + 2.606,

= 150 x 0.75

Resisting moment / Overturning moment

Resisting Shear / Resultant force


Rev: A1
Originator: RSD
Checker:

576.16x 10^6 / (1000 x 1725^2 x 0.85 x 35))

100 x min((1+(1-2.61 Ku))/W,(1+(1-2.61 Ku))/W)


100 x min((1 + sqrt(1 - 2.61 x 0.00651)) / 13.92,
(1 - sqrt(1 - 2.61 x 0.00651)) / 13.92)
Rev: A1
Originator: RSD
Checker:
Serviceability load combination

Max 64.40 810.05 64.40 67.72 - 67.72


Min 7.50 486.03 3.64 12.30 - 25.36

Load Combinations Fx Fy Fz Mx My Mz
101 - DL - 810.050 - - - -
102 - DL + 0.75WL (X) 10.0505 810.050 - 16.479 - -
103 - DL + 0.75WL (Z) - 810.050 4.8754 - - 33.971
104 - DL + 0.53EL (X) 64.3990 810.050 - 67.718 - -
105 - DL + 0.53EL (Z) - 810.050 64.3990 - - 67.718
106 - DL + 0.56WL (X) 7.5043 810.050 - 12.304 - -
107 - DL + 0.56WL (Z) - 810.050 3.6403 - - 25.365
108 - DL + 0.4EL (X) 48.6030 810.050 - 51.108 - -
109 - DL + 0.4EL (Z) - 810.050 48.6030 - - 51.108
110 - 0.6DL + 0.75WL (X) 10.0505 486.030 - 16.479 - -
111 - 0.6DL + 0.75WL (Z) - 486.030 4.8754 - - 33.971
112 - 0.6DL + 0.53EL (X) 64.3990 486.030 - 67.718 - -
113 - 0.6DL + 0.53EL (Z) - 486.030 64.3990 - - 67.718

Strength load combination

Max 91.13 1134.07 91.13 95.83 - 95.83


Min 8.04 729.04 3.90 13.18 - 27.18

Load Combinations Fx Fy Fz Mx My Mz
201 - 1.4DL - 1134.070 - - - -
202 - 1.2DL + 0.6WL (X) 8.0404 972.060 - 13.183 - -
203 - 1.2DL + 0.6WL (Z) - 972.060 3.9003 - - 27.176
204 - 1.2DL + 1.2WL (X) 16.0807 972.060 - 26.366 - -
205 - 1.2DL + 1.2WL (Z) - 972.060 7.8006 - - 54.353
206 - 1.2DL + 0.75EL (X) 91.1306 972.060 - 95.827 - -
207 - 1.2DL + 0.75EL (Z) - 972.060 91.1306 - - 95.827
208 - 0.9DL + 1.2WL (X) 16.0807 729.045 - 26.366 - -
209 - 0.9DL + 1.2WL (Z) - 729.045 7.8006 - - 54.353
210 - 0.9DL + 0.75EL (X) 91.1306 729.045 - 95.827 - -
211 - 0.9DL + 0.75EL (Z) - 729.045 91.1306 - - 95.827
Serviceability load combination

Max 64.40 810.05 64.40 67.72 - 67.72


Min 7.50 486.03 3.64 12.30 - 25.36
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No.

Design of Pump foundation

Dimensions Coordinate C.G of element Static moment of mass Centre of g


Mass (m) kN sec2 (m)
Volume Weight
Description Length Breadth Depth (kN
(m3) (kN)
along x along y along z sec2 / m)
x = mxi /
(m) (m) (m) xi yi zi m xi m yi m zi
m

Foundation Block 5.800 3.100 1.800 32.364 760.554 77.528 2.900 1.550 0.900 224.832 120.169 69.776

Foundation Base slab - - - - - - - - - - - -

Equipment 5.03 2.44 3.16 - 49.496 5.045 2.515 1.220 1.580 12.689 6.155 7.972

Pump - - - - 9.827 1.002 0.610 1.222 0.803 0.611 1.224 0.804

Driver - - - - 17.349 1.768 2.363 1.222 1.201 4.179 2.161 2.124

F1 - - - - 9.200 0.938 0.588 0.360 1.800 0.551 0.338 1.688

F2 - - - - 9.200 0.938 2.128 0.360 1.800 1.996 0.338 1.688 2.841

F3 - - - - 9.200 0.938 3.668 0.360 1.800 3.440 0.338 1.688

F4 - - - - 9.200 0.938 5.208 0.360 1.800 4.884 0.338 1.688

F5 - - - - -1.500 -0.153 0.588 2.740 1.800 -0.090 -0.419 -0.275

F6 - - - - -1.500 -0.153 2.128 2.740 1.800 -0.325 -0.419 -0.275

F7 - - - - -1.500 -0.153 3.668 2.740 1.800 -0.561 -0.419 -0.275

F8 - - - - -1.500 -0.153 5.208 2.740 1.800 -0.796 -0.419 -0.275


= 868.025 88.484 = 251.410 129.384 86.327
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No.

Design of Pump foundation


Eccentricity Check:

ex = 2.9 - 2.841 = 0.059 m % ex = 5.868 / 5.8 = 1.0117 % < 5% Hence SAFE


ey = 1.55 - 1.462= 0.088 m % ey = 8.776 / 3.1 = 2.8310 % < 5% Hence SAFE

Mass moment of inertia Mass moment of the whole system about the axis
Mass moment of iner
about C.G of elements passing through the common C.G & perpendicular to Total
about the centroida
m (b2 + d2) / 12 plane of vibration (kN sec2 m)
(kN
Description (kN sec2 m) (kN sec2 m)

about z xoi = x - xi yoi = y - yi zoi = z - zi m (yoi


2
m (xoi2 m (xoi2 ox =
about x about y x y z
+ zoi )
2
+ zoi2) + yoi2) x + m zi2

Foundation Block 83.020 238.271 279.425 -0.059 -0.088 0.076 1.188 0.811 0.986
Foundation Base slab - - - - - - - - -
Equipment 102.978 227.976 201.926 0.326 0.242 -0.604 37.512 41.742 14.614
F1 - - - 2.253 1.102 -0.824 167.634 509.404 556.773
F2 - - - 0.713 1.102 -0.824 167.634 105.155 152.524
F3 - - - -0.827 1.102 -0.824 167.634 120.603 167.971 1713.627 3090.615 3605.572 1785.298
F4 - - - -2.367 1.102 -0.824 167.634 555.746 603.115
F5 - - - 2.253 -1.278 -0.824 204.598 509.404 593.736
FW PUMP (DIESEL) - 5049-P-0003 A/B
Document No. 1713.627 3090.615 3605.572 1785.298

Design of Pump foundation


F6 - - - 0.713 -1.278 -0.824 204.598 105.155 189.488
F7 - - - -0.827 -1.278 -0.824 204.598 120.603 204.935
F8 - - - -2.367 -1.278 -0.824 204.598 555.746 640.078
= 185.998 466.246 481.351 = 1527.628 2624.369 3124.220
Rev: A1
Originator: RSD
Checker:

Centre of gravity
(m)

y = myi / z = mzi /
m m

1.462 0.976
Rev: A1
Originator: RSD
Checker:

Mass moment of inertia of foundation system


about the centroidal axis of the base area
(kN sec2 m)

oy = x = x / y = y /
y + m zi2 ox oy

3162.287 0.960 0.977


3162.287Rev: 0.960 A1
0.977
Originator: RSD
Checker:

Vous aimerez peut-être aussi