Vous êtes sur la page 1sur 2

TM

Rapide Strata
Twin-bed deionizer with short cycle
regeneration
Produce up to 18 m3/hr of high purity water

RapideTM Strata produces high Short cycle ion exchange (SCIONTM) Extended regeneration option
purity water for healthcare, Regenerates in 30 to 45 minutes Removes need for separate post
surface nishing and utility-feed treatment
Maximizes production time
applications. Its unique design Capable of producing water with
oers savings of up to 40% on Reduces the costs of storing treated
<20 ppb of reactive silica; suitable
water during regeneration
running and euent costs for high and medium pressure
compared to conventional ion Enhances bacterial control boiler-feed
exchange products. SCIONTM Improves chemical usage Produces water of <0.1 s/cm;
technology and an innovative eciencies polishing RO water (Strata + Model)
pulse regeneration sequence
combine to minimize regenera- Fully automated Design & Manufacturing
tion times and improve chemical PLC controlled Skid-mounted, small footprint;
eciencies by up to 50% facilitates installation
Facia mounted display with
5 language options Minimal start-up time
Continuous conductivity monitor Quality controlled manufacturing
with auto service shut o and
Standardized parts
alarm
Minimal operator involvement
RapideTM Strata + Model
Optimal regeneration sequence
Integrated polishing device (HipolTM)
Continual, intermittent or zero
Produces water exceeding Ph Eur
recirculation of water when tank
and USP conductivity requirements.
reaches high level point
TM
Rapide Strata
Equipment Performance
RAPIDETM Strata RAPIDETM Strata+
Model 4 10 18 4+ 10+ 18+
Maximum Flow m3/h 4 10 18 4 10 18
Minimum Flow m3/h 2.5 6.5 14 2.5 6.5 14

AQF0011_EN_V1.0: In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
Regeneration Time minutes 35 35 35 35 - 45* 35 - 45* 35 - 45*
Maximum Flow to Drain during
Regeneration m3/h 2.5 6.5 11.5 2.5 6.5 11.5
Euent Volume per Regeneration m3 0.6 1.5 2.7 0.6 1.5 2.7
Chemical Usage per Regeneration
HCl (32%) liters 6.2 15.4 27.8 6.2 15.4 27.8
NaOH (32%) liters 5.8 14.5 26.1 5.8 14.5 26.1
Bulked Euent pH 6-9 6-9 6-9 6-9 6-9 6-9
Output per Regeneration
(100 mg/l Total Anion load as CaCO3
Inc CO2 & SiO2) m3 20.4 51.6 93.6 16.8 42 75.6
Power Consumption kW 1.5 3 5.5 1.5 3 5.5
* Regeneration:
The RapideTM Strata+ has a 35 minute regeneration for >1M-cm (<1S/cm) water and up to 45 minutes regen for > 10M-cm (<0.1S/cm)

Equipment Dimensions
Model 4 10 18 4+ 10+ 18+
Height mm 2075 2130 2230 2075 2130 2230
Depth mm 900 1100 1300 900 1100 1300
Width mm 1500 2000 2080 1500 2000 2080
Recommended Headroom mm 1000 1000 1000 1000 1000 1000
Approx. Service Weight kg 650 1550 1950 650 1550 1950
Feed Inlet mm 50 63 90 50 63 90
Service Outlet mm 40 50 63 40 50 63
Regeneration Water Inlet mm 50 63 90 50 63 90
Drain mm 32 40 50 32 40 50

Treated Water Quality


TDS mg/l Conductivity S/cm Resistivity M-cm
RapideTM Strata <1 <5 max. <2 average <0.2 max. <0.5 average
RapideTM Strata+ <0.2 1-0.1 1-10

Material Specications Feed Water Supply Quality


Pressure min. 0.1 bar max. 1.25 bar
Pressure Vessels Composite plastic Temperature min. 5C max. 30C
Pipework uPVC
Electrical Supply Options
Pump 316 stainless steel multistage centrifugal 400VAC ( 380-415) , 3 Phase , 50 HZ
Skid Epoxy coated mild steel 380/ 480 VAC, 3 phase 60HZ
Control Valves Air operated diaphragm valves 220/227 VAC, 3 phase 60HZ
Control Cabinet Epoxy coated steel to IP54 Air Supply
5.5 - 6.0 Bar, Instrument Quality, 5 liters per minute intermittent

For higher ow rate applications consult your local Veolia Water


Solutions & Technologies company, contact details below.

Local contact:

Veolia Water Solutions & Technologies


L'Aquarne
1 place Montgoler
94417, Saint Maurice
France
T. +33 (0)1 45 11 55 55
F. +33 (0)1 45 11 55 80
info@veoliawaterst.com
www.veoliawaterst.com/rapidestrata

Vous aimerez peut-être aussi