1 Input data
Channel type; bolt HAC-60 148/300 F; HBC-C 4.6G, M16 x 50 mm
Effective embedment depth hef = 148 mm
Channel specification Length: 300 mm, anchor spacing: 250 mm, projection: 25 mm,
width: bch = 43 mm, height: hch = 36 mm
Material Anchor & Channel: hot-dip galvanized
Bolt: galvanized
Europ. Tech. Assessment (ETA) -
Issued I Valid -|-
Standard CEN/TS 1992-4-3; Hilti Design Method and fib 2011
Base material cracked, C40/50, fck,cube = 50.0 N/mm2, h = 200 mm
Reinforcement Exist. Reinf.: Closely spaced
Straight edge reinf. present
Reinf. to control splitting present
Tolerance data tolerance interval: -250 mm/250 mm
most unfavorable tolerance: 35 mm
2 Overall Result
Design ok! (Maximum utilization: 37%)
3 Geometry
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
3.1 Fixtures / Bolt groups / Loads
Fixture 1
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
hef = 148
a1 a2
25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N V
a1 4.241 -2.121
a2 5.759 -2.879
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
4.3 Derivation of forces acting on anchor channels, Channel b
NaEd,i = k A'i NEd [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1
li = 13 I0.05
y s0.5 356 [mm] s
Iy = 57930 [mm4]
s = 250 [mm]
VaEd,i = k A'i VEd [kN]
MEd,y,max = 0.252 [kNm]
hef = 148
b1 b2
25 250 25
Fixture bolt group
Anchor forces [kN]
Anchor N V
b1 4.241 -2.121
b2 5.759 -2.879
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5 Verifications, Channel a
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 5.759 28.969 20 ok
Connection anchor-channel 5.759 28.889 20 ok
Local flexure of channel lip 5.000 28.889 18 ok
Bolt 5.000 31.400 16 ok
Flexure 0.252 1.841 14 ok
Pull-out 5.759 51.604 12 ok
Concrete cone 5.759 23.336 25 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A
NaEd [kN] NRk,s,a [kN] gMs,a fuk,a [N/mm2] fyk,a [N/mm2] NRd,s,a [kN]
5.759 52.000 1.795 905.0 605.0 28.969
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 6
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5.1.1.4 Bolt (Fixture 1, bolt a1.1, Channel a)
NRk,s
NsEd NRd,s =
gMs,N
NRk,s = As fuk,s
fuk,s
gMs,N = 1.2 1.4
fyk,s
NsEd [kN] As [mm2] NRk,s [kN] gMs,N fuk,s [N/mm2] fyk,s [N/mm2] NRd,s [kN]
5.000 157 62.800 2.000 400.0 240.0 31.400
MEd [kNm] ar Wpl,y [mm3] fyk,c [N/mm2] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.252 7.000 4399 275.0 2.117 1.150 1.841
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 7
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5.1.3 Concrete cone (Anchor a2, Channel a) (CEN/TS 1992-4-3:2009 section 6.2.5 + Hilti Design Method and fib 2011)
NRk,c
NaEd NRd,c =
gMc,c
NRk,c = N0Rk,c as,N y A,N ae,N ac,N,1 ac,N,2 y re,N y ucr,N
N0Rk,c = 8.5 ach fck,cube h1.5
ef
hef 0.15
ach = ( )
180
1
as,N = 1.0
n
S[ ( ]
si 1.5 Ni
1+
i=1
1- )
scr,N
N0
scr,N = 2 (2.8 - 1.3 hef / 180) hef 3 hef
scr,N,A = 3 hef
si,A
y A,N = 0.5 + 1.0
2 scr,N,A
c1 0.5
ae,N = ( )
ccr,N
1.0
ccr,N = 0.5 scr,N 1.5 hef
c2,1 0.5
ac,N,1 = ( )
ccr,N
1.0
c2,2 0.5
ac,N,2 = ( )
ccr,N
1.0
hef
y re,N = 0.500 + 1.0
200
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 8
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Bolt w/o lever arm 2.500 22.608 12 ok
Flexure of channel lip w/o lever arm 2.500 37.222 7 ok
Flexure of channel lip w/o lever arm N/A N/A N/A N/A
parallel
Bolt lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor N/A N/A N/A N/A
Pryout 2.879 46.672 7 ok
Concrete edge failure ** 5.759 15.862 37 ok
Concrete edge failure parallel N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A
**
Shear load distribution with respect to normal holes Fixture 1
5.2.1.2 Local flexure of channel lip - without lever arm (Fixture 1, bolt a1.1, Channel a)
VRk,s,l
VsEd VRd,s,l =
gMs,l
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 9
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5.2.2 Concrete pryout (Anchor a2, Channel a) (CEN/TS 1992-4-3:2009 section 6.3.4 + Hilti Design Method and fib 2011)
VRk,cp
VaEd VRd,cp =
gMc,p
VRk,cp = k5 NRk,c
NRk,c = N0Rk,c as,N y A,N ae,N ac,N,1 ac,N,2 y re,N y ucr,N
N0Rk,c = 8.5 ach fck,cube h1.5
ef
hef 0.15
ach = ( )
180
1
as,N = 1.0
n
S[ ( ]
si 1.5 Vi
1+
i=1
1-
scr,N )
V0
scr,N = 2 (2.8 - 1.3 hef / 180) hef 3 hef
scr,N,A = 3 hef
si,A
y A,N = 0.5 + 1.0
2 scr,N,A
c1 0.5
ae,N = ( )
ccr,N
1.0
ccr,N = 0.5 scr,N 1.5 hef
c2,1 0.5
ac,N,1 = ( )
ccr,N
1.0
0.5
ac,N,2 = ( )
c2,2
ccr,N
1.0
hef
y re,N = 0.5 + 1.0
200
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 10
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
5.2.3 Concrete edge failure, direction y- (Anchor a2, Channel a) (CEN/TS 1992-4-3:2009 section 6.3.5)
VRk,c
VaEd VRd,c =
gMc,e
VRk,c = V0Rk,c as,V ac,V,1 ac,V,2 ah,V a90,V y re,V
V0Rk,c = ap fck,cube c1.5
1
1
as,V = 1.0
n
S[ ( ]
si 1.5 Vi
1+
i=1
1-
scr,V)
V0
scr,V = 4 c1 + 2 bch
c2,1 0.5
ac,V,1 = ( )
ccr,V
1.0
c2,2 0.5
ac,V,2 = ( )
ccr,V
1.0
ccr,V = 0.5 scr,V = 2 c1 + bch
h 0.5
ah,V = h ( )
cr,V
1.0
hcr,V = 2 c1 + 2 hch
5.3 Combined tension and shear loads (CEN/TS 1992-4-3:2009 section 6.4)
Proof of interaction calculated independently for acting load and load distribution
5.3.1 Bolt (Fixture 1, bolt a1.1)
bN,s: governing failure mode - tension: Local flexure of channel lip (Fixture 1, bolt a1.1)
bV,s: governing failure mode - shear: Bolt w/o lever arm (Fixture 1, bolt a1.1)
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 11
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
6 Verifications, Channel b
6.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 5.759 28.969 20 ok
Connection anchor-channel 5.759 28.889 20 ok
Local flexure of channel lip 5.000 28.889 18 ok
Bolt 5.000 31.400 16 ok
Flexure 0.252 1.841 14 ok
Pull-out 5.759 51.604 12 ok
Concrete cone 5.759 30.498 19 ok
Concrete splitting N/A N/A N/A N/A
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A
NaEd [kN] NRk,s,a [kN] gMs,a fuk,a [N/mm2] fyk,a [N/mm2] NRd,s,a [kN]
5.759 52.000 1.795 905.0 605.0 28.969
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 12
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
6.1.1.4 Bolt (Fixture 1, bolt b1.1, Channel b)
NRk,s
NsEd NRd,s =
gMs,N
NRk,s = As fuk,s
fuk,s
gMs,N = 1.2 1.4
fyk,s
NsEd [kN] As [mm2] NRk,s [kN] gMs,N fuk,s [N/mm2] fyk,s [N/mm2] NRd,s [kN]
5.000 157 62.800 2.000 400.0 240.0 31.400
MEd [kNm] ar Wpl,y [mm3] fyk,c [N/mm2] MRk,s,flex [kNm] gMs,flex MRd,s,flex [kNm]
0.252 7.000 4399 275.0 2.117 1.150 1.841
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 13
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
6.1.3 Concrete cone (Anchor b2, Channel b) (CEN/TS 1992-4-3:2009 section 6.2.5 + Hilti Design Method and fib 2011)
NRk,c
NaEd NRd,c =
gMc,c
NRk,c = N0Rk,c as,N y A,N ae,N ac,N,1 ac,N,2 y re,N y ucr,N
N0Rk,c = 8.5 ach fck,cube h1.5
ef
hef 0.15
ach = ( )
180
1
as,N = 1.0
n
S[ ( ]
si 1.5 Ni
1+
i=1
1- )
scr,N
N0
scr,N = 2 (2.8 - 1.3 hef / 180) hef 3 hef
scr,N,A = 3 hef
si,A
y A,N = 0.5 + 1.0
2 scr,N,A
c1 0.5
ae,N = ( )
ccr,N
1.0
ccr,N = 0.5 scr,N 1.5 hef
c2,1 0.5
ac,N,1 = ( )
ccr,N
1.0
c2,2 0.5
ac,N,2 = ( )
ccr,N
1.0
hef
y re,N = 0.500 + 1.0
200
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 14
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
6.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Bolt w/o lever arm 2.500 22.608 12 ok
Flexure of channel lip w/o lever arm 2.500 37.222 7 ok
Flexure of channel lip w/o lever arm N/A N/A N/A N/A
parallel
Bolt lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor N/A N/A N/A N/A
Pryout 2.879 60.997 5 ok
Concrete edge failure N/A N/A N/A N/A
Concrete edge failure parallel N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A
6.2.1.2 Local flexure of channel lip - without lever arm (Fixture 1, bolt b1.1, Channel b)
VRk,s,l
VsEd VRd,s,l =
gMs,l
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 15
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
6.2.2 Concrete pryout (Anchor b2, Channel b) (CEN/TS 1992-4-3:2009 section 6.3.4 + Hilti Design Method and fib 2011)
VRk,cp
VaEd VRd,cp =
gMc,p
VRk,cp = k5 NRk,c
NRk,c = N0Rk,c as,N y A,N ae,N ac,N,1 ac,N,2 y re,N y ucr,N
N0Rk,c = 8.5 ach fck,cube h1.5
ef
hef 0.15
ach = ( )
180
1
as,N = 1.0
n
S[ ( ]
si 1.5 Vi
1+
i=1
1-
scr,N )
V0
scr,N = 2 (2.8 - 1.3 hef / 180) hef 3 hef
scr,N,A = 3 hef
si,A
y A,N = 0.5 + 1.0
2 scr,N,A
c1 0.5
ae,N = ( )
ccr,N
1.0
ccr,N = 0.5 scr,N 1.5 hef
c2,1 0.5
ac,N,1 = ( )
ccr,N
1.0
0.5
ac,N,2 = ( )
c2,2
ccr,N
1.0
hef
y re,N = 0.5 + 1.0
200
6.3 Combined tension and shear loads (CEN/TS 1992-4-3:2009 section 6.4)
Proof of interaction calculated independently for acting load and load distribution
6.3.1 Bolt (Fixture 1, bolt b1.1)
bN,s: governing failure mode - tension: Local flexure of channel lip (Fixture 1, bolt b1.1)
bV,s: governing failure mode - shear: Bolt w/o lever arm (Fixture 1, bolt b1.1)
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 16
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 17
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
7 Installation data
7.1 Fixture 1
Plate type: - Bolt type: HBC-C 4.6G, M16 x 50 mm
Plate dimensions: 250 mm x 200 mm x 8 mm Bolt length: 50 mm
Profile: - Bolt diameter: 16 mm
Anchorplate design calculated: no Diameter hole: 18 mm
Installation torque: 0.060 kNm
125 125
25
b1.1 b1.2
100
150
x
100
a1.1 a1.2
25
35 180 35
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae PROFIS Anchor Channel 1.6.2
Company: Page: 18
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 25/11/2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan