Temperature
Fast Pyrolysis Reactor and Catalytic Cracking
Pressure
Compressor Flowrate
To ensure the safety of the reactor. The reaction will produce gas phase and gas with high temperature will be very da
To ensure that the pressure of downstream of the compressor is meet the required specification so we can ensure there
To ensure that the required temperature is met by the heat transfer between the process stream and cold utility stream.
To ensure that the required temperature is met by the heat transfer in the between two process streams.
To ensure that the pressure of downstream of the pump is meet the required specification so we can ensure there will
To ensure the temperature is in accordance with the hydrolysis process so that the required lignin compound can be d
To ensure the safety of the reactor. The reaction will produce gas phase and gas with high temperature will be very da
To ensure control of the road to the desired specifications.
To ensure a homogeneous reaction
T L
A
Increase the CV-101 opening if the temperature indicator shows the value that is higher that set point so the cooling w
The pressure controller will close the PRV-100 if the pressure indicator shows the value which is below the maximu
reactor can be reduced.
If the flowrate shown by flow indicator is below the specification, the controller will send an electric signal to increas
and vice versa.
If the temperature of the outlet stream is below the specification, the control valves (CV-102, CV-105, CV-110, CV-11
and vice versa.
If the temperature of the outlet stream is above the specification, the control valves (CV-103, CV-104, CV-112, CV-1
decreased so the heat can only be transfered in shorter time and the outlet temperature will be lower and vice versa.
If the flowrate is below the required specification, the control valve (CV-108) opening will be increased so the flowra
Increase the control vessel CV- opening if the temperature indicator shows the value of the cooling water flowrate to
The pressure controller will close the PRV-100 if the pressure indicator shows the value which is below the maximu
reactor can be reduced.
If the level of fluid below the set point range, CV- will decrease so that the flow of liquid flow will be reduced
If not perfect stirring, must check the stirrer motor and check the composition of the reactor outflow.
15
14
Water from
Storage
CV-102
TC
Water from
Storage
FC
16
TI
FI
E-100
PRV-100 M C-100
(Fail Close)
5
49
PC
11
10
TI
V-102
TI PI
13
TC
Feed V-101
TK-100
V-100
6 12
1 2 7 8 9
TC
R-100
17
D-100 D-101
CV-100 D-102 E-101
CV-101
27
B-100
26
FI
28
NCG
C-102 M
FI
FC
CV-114
CV-105 CV-110
TC
36
TI
TC TI
FC FI
E-105
35
23 TC CV-106 PC CV-112
38
M C-104
E-104
PI
TI 33
CV-111 CV-113
E-103
32 TC
V-104
20 V-103 LT
TI
PC
PRV-101
19 (Fail Close)
TI
CV-107 FC FI 42
TI
LT PI
50
TC CV-108
29
25
24
CV-104 R-101 34 R-102
P-102
TC
TC TI 30
18 Fresh Catalyst
E-102
CV-103 31
48
C-101 M CV-109
FI
37
Cooling Cooling
Water In Water Out
FC
21 22
Wet air
40
TI
44
E-107
39
Olefin Product TK-101
TC
41 Water
TI
TC TI
CV-115
43 Flue Gas
E-106
47 46 Air
E-108 C-103 M
FI
FC
45
Water to
51 Reboiler
Char