Head No.
671P3U0721E
6A1P3U0121E
6A1P3U0123E
24th/Apr./2017
SII Printek Inc.
Confidential
The Jetting test with S and M -type WF
Small-WF 1d Small-WF 3d
Medium-WF 1d Medium-WF 3d
Confidential
The Jetting test of 3 head
Wiping effect
Confidential
The Jetting Results
Improves by wiping No improvement by wiping
Confidential
Observation of nozzles
Microscopic observation on the nozzle with the head that did
not improve by wiping.
Head: 6A1P3U0121E
In some cases, deviation could not improve even by wiping or cleaning inside the head.
The deviation could be caused by foreign substances generated inside the nozzle.
It is difficult to recover as those cannot be removed by wiping or cleaning the fluidics.
Question
The returning condition of the head which deviation
improved by wiping ( 671P3U0721E) only differed from
the other 2 heads.
Is there any handling differences before the return to us?
Confidential