Académique Documents
Professionnel Documents
Culture Documents
********
* Results of latest run for rolled W section
* Column Capacity in Compression
* AASHTO LRFD Bridge Design Specs 5th Ed 2010
* Refer to:
* Section 6.9 Compression Members
* Results from: File Name ==> 'TRUSS_ELEMENT.XLSM'
* Version:2.74
* File Code Last Updated on 11/20/2015
* Current Date & Time of Latest Run = 12/23/2015 7:30:43 AM
***********************************************************************************
********
***********************************************************************************
********
* Input values by user:
***********************************************************************************
********
Member # = 1
K_x_column_total = .875
K_y_column_total = .875
K_z_column_total = 1
L_x_column_total = 22 ft
L_y_column_total = 22 ft
L_z_column_total = 22 ft
phi_c = .9
Fy = 33
E_ = 29000 ksi
t_web = .422 in
width_flange = 14.5 in
t_flange = .688 in
k_fillet = .65 in
height_beam = 14 in
***********************************************************************************
********
Calculate W-Section Properties
***********************************************************************************
********
dy_flange = (0.5 * height_beam) - (0.5 * t_flange)
6.656 = (0.5 * 14) - (0.5 * .688)
Agross = 25.279328
Ixx = 955.456523645611
Iyy = 349.654725989963
***********************************************************************************
********
Check K L / r ratios of W section (AASHTO Art 6.9.3):
***********************************************************************************
********
K_L_div_r_xx = K_x_column_total * (12.0 * L_x_column_total) / r_xx
K_L_div_r_yy = K_y_column_total * (12.0 * L_y_column_total) / r_yy
K_L_div_r_control = K_L_div_r_xx
If K_L_div_r_yy > K_L_div_r_control Then K_L_div_r_control = K_L_div_r_yy
If K_L_div_r_control <= K_L_div_r_max Then check_K_L_div_r = 'OK'
If K_L_div_r_control > K_L_div_r_max Then check_K_L_div_r = 'NG'
K_L_div_r_xx = 37.5742
K_L_div_r_yy = 62.1119
K_L_div_r_max = 120
check_K_L_div_r = OK
***********************************************************************************
********
Check b/t ratios per AASHTO LRFD 6.9.4.2.1
***********************************************************************************
********
***********************************************************************************
********
slenderness check of flanges (UNSTIFFENED ELEMENT):
***********************************************************************************
********
check b / t ratios of flange per Table 6.9.4.2.1-1
If b_div_t_flange <= 0.56 * (E_ / Fy) ^ 0.5 Then check_b_div_t_flange = 'flange
non-slender'
If b_div_t_flange > 0.56 * (E_ / Fy) ^ 0.5 Then check_b_div_t_flange = 'flange
slender'
If check_b_div_t_flange = 'flange non-slender' Then Q_flange = 1.0
If check_b_div_t_flange = 'flange slender' Then Q_flange = 999.0
***********************************************************************************
********
b_flange = width_flange / 2.0 = 7.25
b_div_t_flange = b_flange / t_flange = 10.5378
0.56*(E_ / Fy)^0.5 = 16.6008
check_b_div_t_flange = flange non-slender
Q_flange = 1
***********************************************************************************
********
Slenderness check of web (STIFFENED ELEMENT):
***********************************************************************************
********
Check h / t ratios of web per Table 6.9.4.2.1-1
If h_div_t_web <= 1.49 * (E_ / Fy) ^ 0.5 Then check_h_div_t_web = 'web non-
slender'
If h_div_t_web > 1.49 * (E_ / Fy) ^ 0.5 Then check_h_div_t_web = 'web slender'
If check_h_div_t_web = 'web non-slender' Then Q_web = 1.0
If check_h_div_t_web = 'web slender' Then Q_web = 999.0
***********************************************************************************
********
h_div_t_web = h_web / t_web = 30.0948
1.49*(E_ / Fy)^0.5 = 44.1701
check_h_div_t_web = web non slender
Q_web = 1
***********************************************************************************
********
* AASHTO 6.9.4.2.2 Slender Elements;
* The following section below only applies if;
* Q_flange is slender and/or
* Q_web is slender
***********************************************************************************
********
***********************************************************************************
********
* Slender unstiffened flange calculations:
***********************************************************************************
********
* If check_b_div_t_flange = 'flange non-slender' Then Qs_flange = 1.0
* [AASHTO Eq 6.9.4.2.2-1]
* If check_b_div_t_flange = 'flange slender' And b_div_t_flange > 0.56 * (E_ /
Fy)^0.5 And b_div_t_flange <= 1.03 * (E_ / Fy)^0.5 _
* Then Qs_flange = 1.415 - 0.74 * b_div_t_flange * (Fy / E_) ^ 0.5
* [AASHTO Eq 6.9.4.2.2-2]
* If check_b_div_t_flange = 'flange slender' And b_div_t_flange > 1.03 * (E_ /
Fy)^0.5 _
* Then Qs_flange = 0.69 * E_ / (Fy * (b_div_t_flange^2.0))
* f_ = Qs_flange * Fy
***********************************************************************************
********
check_b_div_t_flange = flange non-slender
b_div_t_flange = 10.5378
0.56*(E_ / Fy)^0.5 = 16.6008
1.03*(E_ / Fy)^0.5 = 30.5337
1.415 - 0.74 * b_div_t_flange * (Fy / E_) ^ 0.5 = 1.1519
0.69 * E_ / (Fy * (b_div_t_flange ^ 2.0) = 5.4605
Qs_flange = 1
f_ = 33 ksi
***********************************************************************************
********
* Slender stiffened web calculations:
***********************************************************************************
********
* AASHTO Eq 6.9.4.2.2-11
* b_e_web_temp = 1.92*t_web*(E_/f_)^0.5*(1.0-0.34/h_div_t_web)*(E_/f_)^0.5
* If b_e_web_temp <= h_web Then b_e_web = b_e_web_temp
* If b_e_web_temp > h_web Then b_e_web = h_web
* A_eff_web = A_gross_web - ((h_web - b_e_web) * t_web)
* A_flanges = 2.0 * width_flange * t_flange
* A_eff_beam = A_eff_web + A_flanges
* AASHTO Eq 6.9.4.2.2-9
* Q_a_eff_web = 1.0 If check_h_div_t_web = 'web non slender'
* Q_a_eff_web = 1.0 If A_eff_beam /A_gross >1.0 and check_h_div_t_web = 'web
slender'
* Q_a_eff_web = A_eff_beam /A_gross If A_eff_beam /A_gross <= 1.0 and
check_h_div_t_web = 'web slender'
* Q_ = Q_a_eff_web * Qs_flange
***********************************************************************************
********
check_h_div_t_web = web non slender
h_div_t_web = 30.0948
b_e_web_temp = 15.9748 in
b_e_web = 12.7 in
A_eff_web = -19.952 in^2
A_flanges = 19.952 in^2
A_eff_beam = 0 in^2
Q_a_eff_web = 1
Q_ = 1
***********************************************************************************
********
* Determine Q_control:
***********************************************************************************
********
* Q_control = Q_web
* If Q_flange <= Q_control Then Q_control = Q_flange
* If Q_ < Q_control Then Q_control = Q_
***********************************************************************************
********
Q_control = 1
***********************************************************************************
********
Section 6.9.2 Compressive Resistance of Members (LRFD design):
***********************************************************************************
********
Po_ = Q_control * Fy * A_gross
***********************************************************************************
********
* Section 6.9.4.1.2 Elastic Flexural Buckling Resistance:
***********************************************************************************
********
* Pe_flexural_buckling = ((PI ^ 2) * E_ / (K_L_div_r_control ^ 2)) * A_gross
Pe_flexural_buckling = 1875.4832 kip
***********************************************************************************
********
* 6.9.4.1.3 - Elastic Torsional Buckling and Flexural - Torsional Buckling
Resistance
***********************************************************************************
********
***********************************************************************************
********
* Minimum controlling Pe value from 'Pe_torsion' or 'Pe_flexural_buckling'
* Pe_control = Pe_flexural_buckling
* If Pe_torsion < Pe_control Then Pe_control = Pe_torsion
***********************************************************************************
********
Pe_control = 1875.4832 kip
***********************************************************************************
********
* Pn_, nominal compressive resistance per AASHTO Eq 6.9.4.1-1 or Eq 6.9.4.1-2
* If Pe_control / Po_ >= 0.44 Then Pn_ = (0.658 ^ (Po_ / Pe_control)) * Po_ <==
AASHTO Eq 6.9.4.1-1
* If Pe_control / Po_ < 0.44 Then Pn_ = 0.877 * Pe_control <== AASHTO Eq 6.9.4.1-2
***********************************************************************************
********
Pe_control / Po_ = 2.2482
(0.658 ^ (Po_ / Pe_control)) * Po_ = 692.51 kip
0.877 * Pe_control = 1644.7988 kip
Pn = 692.51
***********************************************************************************
********
* Pr_, factored compressive resistance per AASHTO Eq 6.9.2.1-1
* Pr_ = phi_c * Pn_
***********************************************************************************
********
Pr = 623.259