Table 1-a DIN Wire Type IQI

DIN Pack Wire Diameter (mm)


Designation Corresponding Wire Number
3.20 2.50 2.00 1.60 1.25 1.00 0.80
1 FE DIN
1 2 3 4 5 6 7
1.00 0.80 0.63 0.50 0.40 0.32 0.25
6 FE DIN
6 7 8 9 10 11 12
0.40 0.32 0.25 0.20 0.16 0.125 0.1
10 FE DIN
10 11 12 13 14 15 16

Table 1-b ASME Wire Type IQI


Set A Set B Set C Set D
Diameter(mm) Identity Diameter(mm) Identity Diameter(mm) Identity Diameter(mm) Identity
0.08 1 0.25 6 0.81 11 2.54 16
0.10 2 0.33 7 1.02 12 3.20 17
0.13 3 0.41 8 1.27 13 4.06 18
0.16 4 0.51 9 1.60 14 5.08 19
0.20 5 0.64 10 2.03 15 6.35 20
0.25 6 0.81 11 2.54 16 8.13 21

Table 3. IQI selection


Unless otherwise stated in the Scope of Work,
IQI shall be selected as shown in the following columns.
DIN IQI ASTM IQI
Nominal Single-Wall Material Thickness
Source Side Film Side Source Side Film Side
inch mm Wire No. Wire No. Wire No. Wire No.

Up to 0.25, incl. Up to 6, incl. 13 14 5 4

Over 0.25 through 0.375 6 through 10 12 13 6 5

Over 0.375 through 0.50 10 through l2 11 12 7 6

Over 0.50 through 0.75 l2 through 18 10 11 8 7

Over 0.75 through 1.00 18 through 25 9 10 9 8

Over 1.00 through 1.50 25 through 40 8 9 10 9

Over 1.50 through 2.00 40 through 50 7 8 11 10

Over 2.00 through 2.50 50 through 60 6 7 12 11

Over 2.50 through 4.00 60 through 100 5 6 13 12

Over 4.00 through 6.00 100 through 150 4 5 14 13

Over 6.00 through 8.00 150 through 200 2 4 16 14

Over 8.00 through 10.00 200 through 250 1 2 17 16