Vous êtes sur la page 1sur 18

SCADA- Whats New

1
Agenda

SCADA and HMI System Overview, System Limits

Rockwell SCADA Hierarchy

FactoryTalk Introduction

FactoryTalk Components

FactoryTalk ViewPoint
Key Drivers
Basic Architecture
Architecture & Options
Architecture Building Blocks

SCADA

Supervisory Data
Control Acquisition

PC based
HMI Reports Analytics
HMI
Factory Talk Services Platform
Why Factory Talk View
RS View FT View(New
32(Prev. Version) Version)

Operating Systems
Windows XP-MS Support Ends
Windows 7 new standard OS
Windows Server 2012
OS-64bit System
License Activation
Supports Single activation for multiple application
Take advantage of data sharing in new
IA(Integrated Architecture) core for Rockwell
Automation Products.
Factory Talk View - Comparison

Development RS view 32 FT view


works Studio
Environment

FT view
Runtime Environment RS view 32 Studio site
Runtime edition station

Distributed Environment RS view 32 FT view


Active display Studio client
server

License Scheme Display


Tag Based Based
Direct Tag Referencing
Alarms & Events
Two different types of Alarm sources:
Alarm instructions available in the Software-based alarm servers poll data
Logix family of controllers. tags
for alarm conditions.
The controller detects alarm conditions The Alarm server detects alarm
and conditions and triggers alarm events
triggers alarm events
The FactoryTalk Alarms and Events The FactoryTalk Alarms and Events
server captures all of the controller server captures all of the controller
events and sends notification to events and sends notification to
connected clients connected clients
Information is displayed in the Alarm Information is displayed in the Alarm
Management components on the Management components on the
clients clients
Supports PLC-5, SLC 500, or any third-
party device through OPC-DA

Device Tag-Based
Based Alarms
Alarms
Alarms & Events - Architecture

Alarm and FactoryTalk View


Event Setup Summary External
Alarm &
FactoryTalk View Event
Database Setup Log Viewer databases

FactoryTalk View
FactoryTalk View Studio Banner
or
FactoryTalk Admin Console FactoryTalk View Status
Explorer
FactoryTalk View SE Client
FactoryTalk Alarm and
Event Services

Tag Alarm and Event


Server Device Alarm and Event
Server
OPC-DA
RSLinx Server RSLE RSLE Alarm Services
Tag-based Alarm
Detection

Third Party Device-based Alarm


PLC 5, SLC Controllers Logix Family Detection

PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.
28
ISA 18.2

New Shelve buttons


available on Alarm

Enter shelve time


duration and
Web Enablement
PanelView Plus with ViewPoint

Support single client connection


to a PanelView Plus

FactoryTalk View SE Station with ViewPoint

Gain web browser access to your


single station nodes

FactoryTalk View SE Server with ViewPoint

Extend your distributed system to


mobile web clients like the
Microsoft Surface Pro Tablet
Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.
35

PUBLIC INFORMATION
Data Logging
Supervisor /
Operator Management
FT View Studio FT VIEW SE Clients Clients
FactoryTalk

Domain 50 display 100 display Data


100 display Area
server server server RSLinx
Controllers

Recommended on a separate computer


- Allow for IT ownership /
management
- Accommodates database clustering,
redundant databases

15
(Confidential For Internal Use Only) Copyright 2007 Rockwell Automation, Inc. All rights reserved.
True Redundancy
Panel View - Evolution
Green~Wave
Nurturing Aspirations in a Green World

Vous aimerez peut-être aussi