Vous êtes sur la page 1sur 2

CONTROLLER PANELS

MicroBASIC

DESCRIPTION
The Microbasic Controller boasts centralised electronics and parallel Apart from the controller panel, the Microbasic Controller Panel includes the
communication and can support a maximum of 10 stops without electrical network adaptation elements, emergency power supply, rescue
battery lift connection. Thanks to the AMB1 and AMB2 electronic devices, connection terminals and, for 3 VF lifts, the frequency changer.
expansion modules, it can reach up to 16 stops and batteries of 2 lifts.
The Microbasic Controller Panel is available for lifts with or without a
It allows for the control of 1 or 2 speed hydraulic lifts and also electronic machine room.
lifts of 1 speed, 2 speeds or frequency variation (3VF) whether they have
asynchronous (with electronic gears) or synchronous (gearless) motors.
In the case of frequency variation, the combination of the Microbasic
controller and the DSP 6P inverter guarantees the best features possible
with a high level of comfort.

www.mplifts.com
CONTROLLER PANELS
MicroBASIC

FEATURES Opt : optional | Std : standard

BUILDING / SHAFT
Maximum number of stops 10
Maximum number of stops with AMB1/AMB2 expansion modules 16
Double or triple access Opt
MRL cabinet on the top floors (distance from the machine is 10m) Std
MRL cabinet on the ground or middle floor (distance from the machine is
Opt
25m)
CONTROLLER
Maximum number of battery lifts 2
Universal controller Std
1 or 2 push button selective controller Std
Binary display position signals Std
Signs showing next departure Std
Engaged sign Std
Maximum speed of 1.6m/s Std
STANDARDS
EN81-1 (ELECTRICAL LIFT) Std
EN81-2 (HYDRAULIC LIFT) Std
EN81-1/2 A2 (MRL) Std
EN81-73 (Fire) Opt
INCLUDED ELEMENTS
Controller plate with programming interface (push buttons + display) Std
DSP 6P frequency changer (3VF ELECTRICAL LIFT) Std
Soft Starter (HYDRAULIC LIFT) Opt
Electrical protection kit Opt
In-cabin machine room intercom Opt
SUPPORTED ELEMENTS
Supplied voltage 380/400/415 Vac triphasic Std
Supplied voltage 208/220 Vac triphasic Opt
Supplied voltage 220/230 Vac monophasic Opt
Machine brake voltage 220 Vac (ELECTRICAL LIFT) Std
Machine brake voltage 220 Vac (ELECTRICAL LIFT) Opt
Machine thermocontact connection (ELECTRICAL LIFT) Std
Valve voltage 110 Vac (HYDRAULIC LIFT) Std
Valve voltage 110 Vac (HYDRAULIC LIFT) Opt
Automatic and/or semi-automatic external doors Std
220 Vac monophasic door operator Std
Other type of door operator Opt
FUNCTIONS
Automatic rescue in the case of a power supply failure (3 VF ELECTRICAL
Std
LIFT, HYDRAULIC LIFT)
Electrical SOS controller (3 VF ELECTRICAL LIFT) Std
Electro-manual rescue by load imbalance (GEARLESS ELECTRICAL LIFT WITH
Opt
MACHINE CONTROL ROOM)
FTCCUMANMBENV00

www.mplifts.com

Vous aimerez peut-être aussi