Hot water
Space heating
Solar cooling
Swimming pools
Solar water heating
Primarycircuit:
Collectorsarray
Collectors array
Closedcircuit
Pumpandexpansiontank
Regulation
Heatexchanger
Solar water heating
SolarTank:
Externalorinternalheatexchanger
External or internal heat exchanger
Verticalcylinder
Corrosionresistantmaterial
Thermalinsulation
Thermalsensorandtermometer
Solar water heating
HW consumption
Auxiliaryheater:Boiler
SSolartankasapreheatingbefore
l k h i b f
theboiler
Solartankasapreheatingofthe
p g
SWtankheatedbytheboiler/or
themodulantboiler
Cold water
Solar water heating
Solarcontrol
A
Atleast2thermalsensors(atthetopof
l 2 h l ( h f
solarcollectorandthebottomofthe
solartank)
Thecirculationpumpturnson/off
dependingontemperaturedifferential
betweenbothsensors
Solar collectors
Flat plate
Flatplate
Evacuatedtube
Flatt plate
Fl l t
collector
Flatplatecollectorheat
balance:
solarradiation
solar radiation
absorption,
thermallosses
usefulheat
Solar Flat Plate collector
Flatplatecollector
efficiency
characterization
Opticallosses
Thermallosses
(dependingtemperature
differencebetween
absorberandambient)
Solar Flat Plate collector
Differentcollectors
efficiency
characterization
unglazed
glazedflatplate
selectivecoat
evacuatedtube
Solar Flat Plate collector
Absorberdesign:grillshape,
serialgrill,andmeandershape
Theflowpersquaremeterisdifferentinthesethreedesigns
Solar Flat Plate collector
Mostsolarflatplatecollectorsarearound2m2.Butalsolargersolarcollectors
of7,10ormorem2adequateforbiginstallations:fewerconnections,less
q g
thermallosses
3 9 72
1580
0
1698
8
1 0 03 983 98 3 1 0 03
Exampleoflargeflatplatecollectors
Distance from obstacles
d=h/tan
d=(Lsin)/tan
D=hxk Lebanon: 33 N
Solar Flat Plate collector
CEDROminimal performance
requirements
opticalefficiency:0,7
thermallosses:5,5W/m2K
thermal losses: 5,5 W/m2 K
Ifavailablespaceisnotenough,ahigher
performancecollectorcanbeused
p y ,
opticalefficiency:0,79
thermallosses:3,21W/m2K
Solar collectors mounting
Strongwindcandestroy
solarinstallationsifthe
structureorblocksthat
supportpergravityare
t it
undersized
Structure and piping
Pipinglengthsshallbe
Pi i l th h ll b
minimizedtoreduceheat
lossesandpressuredrop
(lower than 40 mm wc /m)
(lowerthan40mm.wc./m)
Theflowspeedshallbe
calculatedintherangeof
2 5 3 m/s
2,53m/s.
St
Structure
t
The total
Th t t l load
l d shall
h ll
guarantee no risk of wind
uplift of the solar
collectors
co ecto s / support
suppo t
frames for wind speeds
up to 120 km/hour.
Outdoor piping insulation protection
Aluminum sheet
serial
se a
parallel
No
B l
Balance b
by valves
l
Balance by
reverse return
C ll t
Collectors
Balance by valves
Balance by
reverse return
Coupling and connection terminals
Threaded coupling for connecting
t bes or accessories conical
tubes
pressure, etc..
Solar
tank
Sizing:itsratedpowershallbenolessof500xcollectors
surface.
Theheatexchangersshallbesuitableselectedand
installedtooptimizetheheattransferefficiencyandeasy
toremoveforperiodiccleaning.
Solar hot water tank
Solartankcharacteristics
Goodthermalinsulation
Height>thandiameterand
verticallyinstalled
Externalprotection
Heatexchanger:internalor
external
Internalsurfaceprotection
Internal surface protection
Anticorrosivedevice
Solar hot water tank
Solartanklocation
Asclosetothesolararraythanpossible
As close to the solar array than possible
Betterinsideatechnicalroomthanoutdoor
Thetankinsulationpolyurethanewith
minimumthicknessof50mm
Solar hot water tank
When
Whenmorethanonesolar
more than one solar
tankisnecessary,theyare
connectedinseries
Regulation
Solar
collectors
B1
Solar
collectors
B1 B1 B2
B1turnsonwhen Solarradiationis>ex.300W/m2
B2turnsonwhen T=T1 T2=ex:4C)
B2turnsoffwhen T=T1 T2=ex:2C)
Monitoring
Calorimeter
Flow meter
Calorimeters
Measure solar
energy produced
Q =V ce t
Data logging and performance indicators
Anti legionella circuit
Thermaltreatmentagainstthelegionellabacteria
Thelegionellabacteriaisharmfulwheninhaledviamicrodropletsoraerosol(example
at a shower)
atashower)
Theoptimaldevelopmenttemperatureforthelegionellabacteriais35 37C,butcan
reproducebetween25and45C.At70Cormoreisdestroyed
TopreventthelegionellasicknessaregularthermaltreatmentoftheHWinstallationis
h l i ll i k l h l f h i ll i i
recommended(iscompulsoryforpublicbuildingsinmanycountries)
Aspecificrecirculationcircuitisneededtotransferhotwaterfromtheboilertanktothe
solartanksuntill70Cdegreesareattained.Sometimesthesetemperaturesarealso
l k ll h l
reachedwithsolarenergy
CEDRO SHW reference hydraulic schematics
Solar Collector
array
Temperature
p
sensor
Mixing
valve
Reversed
return
HW consumption and
recirculation loop
Primary
circuit
pump
Booster
pump
Solar Existing
tanks HW tank Boiler
Sports arena: hydraulic schematics
25.000HWlitres/day[235users]
f=35%.
Sports arena: solar collectors and heat dissipation
Sports arena: solar tanks and pumps
Heat dissipation
Whenthemaximumsolartankstemperature
, p p
isreached,thecirculationpumpturnsoffand Passivedissipation
p
aheatdissipation maybenecessary
Activedissipation
Reference values for a SWH model
GENERAL SPECIFICATION
Demand Daily hot water demand 2200 L/day
( Rated output temperature
60C)
Type Flat-plate
Solar array
arra Tilt/orientation 455/020 S
Total Collector area (1) 45 m2
Piping system Primary circuit Pressure drop 40 mmwc
Flow velocity 2,5-3 m/s
S
Secondary
d circuit
i i P
Pressure d
drop 40
40 mmwc
Flow velocity 2,5-3 m/s
Pump Flow 2025 L/h
Pressure drop 6 mwc
Number/Capacity 1/2000 L; 1/100L
Hot Water Tank Connection Series inverted
Installed capacity 3000 L
Expansion tank Volume ~ 160L
Heater exchanger External ~ 32 kW
Minimum Data logger and processor Performance evaluation: temperatures, water
consumption, solar energy produced, energy balance,
reference radiation and ambient temperature.