The gas flow through the ing by means of elastomere and wide measuring ranges
rotary gas meter measure- gaskets. Thanks to this, the of our CGR Rotary Gas
ment chamber makes the possible stresses, e.g. aris- Meters.
two 8-shaped rotors to ing from improperly aligned The CGR Rotary Gas Meter
turn. The volume of gas piping, have no influence on consists of the following
closed between the me- measurement results of the main assemblies:
asuring chamber walls and CGR Rotary Gas Meter. Pressure resistant housing
rotors is transported four Moreover, the measuring Measuring assembly
times in one full cycle from cartridge elements are made Magnetic coupling
the meter inlet to the out- of materials with carefully Index head
let. The timing gears set the selected values of thermal All parts subject to servic-
rotors at the angle of 90 expansion coefficients. ing or maintenance, like
one to the other. The gear This minimizes temperature mechanical counter, LF (HF)
train, and the incorporated stresses that could cause sockets, oil filler and drain
gas tight and hermetic mag- the rotor seizures. plugs, oil level sight-glass,
netic coupling, transfers the All above factors, together are located on the front
rotor rotation to the index with the highest precision side of the meter. Thanks
unit, which is separated in machining of parts allow to this, it is not necessary
that way from the pressure to reduce small but neces- to access the back side of
tight housing. The actual sary clearances between the CGR meter and then it
volume of gas is indicated the moving rotors and the could be located very close
on the mechanical counter. measurement chamber to a wall or other construc-
The measurement cartridge, walls, what reduces gas tion element what reduces
as a separate unit, is fixed in leakages to minimum and the installation deep.
the pressure resistant hous- results in very high accuracy
Index head
Magnetic coupling
2 Measuring assembly
DESIGN
&
table 1:
80/100 s 1,310
160 250 5,0 4,0 3,0 2,5 2,0 1,6 1,3 p 2,020 0,1
w 3,385
s 2,020
250 400 8,0 6,0 5,0 4,0 3,0 2,5 2,0 1
100 p 3,385
400 650 13 10 8,0 6,0 5,0 4,0 3,0 s 3,385 1
p basic, recommended
s high speed version, smaller sizes, higher possible rangeability, higher noise level
w low speed version, bigger sizes, smaller possible rangeability, lower noise level
Q t transition flow +2
-2
Q min Q t Q max Q
Chemical
Density Density Gas meter
Gas symbol
[kg/m3] related to air execution
(formula)
3 MEASUREMENT OUTPUTS
PULSE SENSORS
The mechanical index unit indicates the actual volume of the measured gas at operat-
ing temperature and operating pressure. It can be rotated axially by 350 in order to
facilitate the readings and enable easier connection of pulse sensor plugs.
The index unit is provided with one low frequency LFK reed contact pulse transmitter,
as a standard. On request the index may be equipped with:
- LFI inductive pulse sensor (NAMUR)
- HF inductive pulse sensor (NAMUR)
4
MEASUREMENT
HF LFI LFK, AFK OUTPUTS
Ui = 16 V Dc Ui = 15,5 V DC Ui = 15,5 V DC
Ii = 25 mA Ii = 52 mA Ii = 52 mA
Pi = 64 mW Pi = 169 mW Pi = 169 mW
Index head
Temperature
pockets (option)
Socket 2 (option)
The CGR Rotary Gas Meters may be provided with up to 6 pulse sensors.
LFK low frequency reed contact pulse sensor LFK1, LFK2
LFI low frequency inductive pulse sensor LFI1, LFI2
HF inductive pulse sensor in the index unit HF1, HF2
AFK anti-fraud reed contact AFK
5
4 DIMENSIONS
The main dimensions and weights of the CGR Rotary Gas Meters are shown in table 4.
Series 171
p basic, recommended
s high speed version, smaller sizes, higher possible rangeability, higher noise level
w low speed version, bigger sizes, smaller possible rangeability, lower noise level
6
DIMENSIONS &
GAS METER
5 SELECTION OF CGR
SELECTION
In order to choose the proper size of the rotary gas meter the following operating
condition parameters should be known:
flow range Q min m and Q max m [m 3 /h]
pressure range p min m and p max m [bar a]
gas temperature range [K]
Usually flow range is given at standard conditions: Q minN and Q maxN [Nm 3 /h].
Base conditions (NPT conditions: normal temperature and normal pressure)
are country specific.
The following formula is to be used when converting standard flow cubic meters
per hour into actual flow at operating conditions:
ps T min m ps T max m
Q min m = Q min s Z Q max m = Q max s Z
p max m T p min m Ts
s
DEFINITION:
The gas meter size should be chosen (using actual flow at operating conditions)
according to the following formula:
Q min < Q min m
Q max > Q max m
where Q min and Q max minimum and maximum flow, typical for the selected gas meter.
7
6 PRESSURE LOSS
The inevitable pressure loss during the gas flow through thee m
me
meter
e teerr iiss
ete
determined at the atmospheric conditions.
p+p s
p 1 = ( )( ) p
a ps
200
100
100
50
40
50
30 40
30
20
20
10 10
10 20 30 40 50 70 100 10 20 30 40 50 100
Q Q
[%] [%]
Q max Q max
DEFINITION:
8
7 INSTALLATION AND OPERATION
RECOMMENDATIONS
To assure proper work of the lubricating system, the meter has to be installed in hori-
zontal position, and any mechanical shocks during the installation are not permitted.
It is recommended to install the meter in closed compartments, if possible. When
installed outdoors a protection against direct weather influence should be used.
The piping should be executed so as to avoid unnecessary stresses acting on the meter.
When starting the gas flow through the installation, the valves should be opened
slowly to avoid gas impingement which could damage the meter.
COMMON S.A. has continuing program of product research and development. Technical specifications and con-
struction may change due to improvements. This publication serves as general information only, and all specifica-
tions are subject to confirmation by COMMON S.A.