DeltaV SIS for Process Safety Systems

TM

A Modern Safety Systemfor the Life of Your Plant


DELTAV SIS
The DeltaV SIS TM
takes a modern approach to increase safety integrity while improving
process reliability. The proven DeltaV SIS continuously monitors your plants safety devices status
and diagnoses the health of the entire safety loopdramatically reducing your risk. The SIL 3
certified system uses electronic marshalling technology to reduce your installation, commissioning
and maintenance costs while substantially reducing your equipment footprint. DeltaV SISmeets
your safety system needs today and into the future.

Smart SIS. Logic Solvers


Final Control
Optimized diagnostics for
Elements
the entire safety loop Sensors
DeltaV SIS provides an integrated,
constant monitoring approach for
the complete safety loopfrom
sensor, to logic solver, to final
control element. A key
component of Emersons Smart
SIS is to detect field device failures
before they cause spurious trips.

Distributed Architecture
Flexibility with Electronic Marshalling
The modern, scalable architecture changing project requirements
is based on the CHARMs Smart and the flexibility to implement
Logic Solver (CSLS) which safety functions easily, and safely
simplifies the design, installation, while eliminating re-work and re-
wiring and commissioning of any design associated with traditional
SIS project. This modularity gives marshalling.
you the capability to meet

Flexible Integration
Familiar, intuitive applications for greater availability
As a standalone safety system, The DeltaV SIS and DeltaV systems The integrated yet separate
DeltaV SIS can easily be are integrated noticeably in the architecture meets IEC 61508 and
integrated with control systems same engineering, maintenance, IEC 61511 requirements for
from other vendors using and operations environment. All physical separation and
interfaces that are based on open safety-related information is easily independence of safety and
communication standards, such accessible through familiar and control. DeltaV SIS delivers the
as Modbus, OPC and OPC.Net. intuitive applications. benefits of DeltaV integration and
separation without the tradeoffs
associated with the two extremes.
Page 2DeltaV SIS
Certified Function Blocks
Reduce engineering and complexity
The IEC 61508-certified SIS Out-of-the-box operator faceplates
function blocks deliver powerful automatically provide detailed
functionality out of the box, safety information with no
simplifying the implementation of configuration. Using these SIS
SIS applications. No custom code is function blocks can help
required to implement common eliminate engineering hours
SIS tasks. The result is faster required to implement emergency
configuration, troubleshooting shutdown (ESD) systems, fire and
and validation of SIS logic. gas systems (FGS), and burner
management systems (BMS).

Built for IEC 61511


Compliance
Simplified safety lifecycle
management
DeltaV SIS is built for IEC 61511
compliance, providing stringent
change management, security
management, and documentation
tools. The system is certified by
TV for use in safety integrity
level (SIL) 3 applications
without restriction.

A typical refining or petrochemical facility will


spend less than 10% of its time in transient
operations, but more than 50% of process safety


incidents occur during these operations.
Duguid, I.M.
Chemical Engineering

Page 3DeltaV SIS


IMPROVE SAFETY INTEGRITY
Understanding the complexities of standards and staying compliantcoupled
with the increasing demands to reduce costsare a constant challenge.

Safety applications are designed to Plant and


protect your plant and personnel Emergency Emergency Response Layer
Response
from hazardous conditions and
provide a rapid and coordinated Mitigate Containment,
Dike/Vessel Passive Protection Layer
operational response to
emergency situations. Fire and Gas
System Active Protection Layer
Incident
But with traditional safety systems, Emergency
SIS
once its installed and validated, Shutdown Emergency Safety Layer
System Trip level alarm shutdown
your plants safety integrity level Prevent
quickly begins to decline as loops Operator
Intervention Operator Process Control Layer
are not called upon regularly Process alarm intervention
enough to ensure all devices are BPCS
functioning as they should. A Process
value
Process Control Layer
traditional safety system may not Normal behavior

know for months or longer that a


valve is stuck.

The modern DeltaV SIS continually operator faceplates. The result is detect certain conditions, and the
monitors the health of the entire your SIS integrity level stays at a DeltaV SIS logic solver is
safety loop. It takes into account stable level longer, extending the configured to meet your safety
devices predicted lifespan and time between full proof tests. requirements to take your plant to
pre-empts end of lifecycle with a safe state, by manipulating the
maintenance notifications and The DeltaV SIS ensures high required final elements (valves,
testing that can be initiated reliability and availability through pumps).
automatically by the DeltaV SIS redundant architecture design,
logic solver, or manually from including redundant networks, The combination of sensor, logic
logic solvers and I/O. The system solver and final element form a
routinely monitors, controls and safety instrumented function (SIF).
collects safety-related data for Each SIF is designed to prevent a
ESD, FGS and BMS applications. specific hazard from occurring by
reducing a certain amount of risk.
Prevent incidents from This risk reduction equates to a
occurring safety integrity level (SIL). The
The DeltaV SIS has been widely DeltaV SIS modern system
used for emergency shutdown provides SIL 3 reliability in
applications to prevent hazardous compliance with IEC 61508 and IEC
Emergency situations from occurring, and can 61511 international standards,
Shutdown System initiate the shutdown of a plant, and in addition has many
unit, or piece of equipment should innovations: repeat confirmation
it be required. Sensors are used to built into the operator graphics,

Page 4DeltaV SIS


tracking changes that can be with the ESD system to initiate
defined by SIL level, powerful plant shutdown if hazardous
voting functionality and a very events occur.
flexible cause-and-effect matrix
(CEM) function block that is The integrated system can alert
intuitive and easy to use. personnel in a fast, accurate and
structured way, giving employees
Mitigate the time to decide what course of
consequences of events action to take while bringing the
when they occur plant to a pre-determined state.

Permit the system to


operate when safe

Fire and Gas System

IEC 61511 recognizes fire and gas


systems (FGS) as mitigative SIS
systems. The major focus of a FGS
is to mitigate an incident AFTER it
has occurred. This is done to gain Burner Management System
time for people to evacuate the DeltaV SIS has been used for
area, contain the incident from burner management system (BMS)
escalating, and allow emergency applications, a safety solution to
response teams to assess and deal control and monitor burner units.
with the incident. By monitoring Through proper sequencing and
process areas where fire, build up interlocks, the DeltaV SIS BMS
of a potentially flammable gas or application allows the burner
toxic gases may occur, DeltaV SIS unit(s) to go safely through all
can detect these hazardous relevant states, from start-up to
events, alert personnel and initiate operation and shutdown when
timely actions in order to minimize needed. If so required (usually
the consequences of an incident. dependent on the size of the
burner unit), the DeltaV SIS system
Fire and gas systems are usually can also be configured to provide
standalone systems that take automated leak testing of the gas
actions when required. With valves. Using specially developed
todays technology, many function blocks, the DeltaV SIS
companies use an integrated BMS solution is highly flexible and
approach and interface the FGS easy to maintain and monitor.

Page 5DeltaV SIS


KNOW THE HEALTH
OF YOUR SAFETY LOOPS24/7
Because safety systems are designed to perform only when an abnormal
situation occurs, how to make sure it will perform reliably when needed?

A modern approach to elements to perform on demand increase the overall reliability of


safety by diagnosing faults before they the entire SIF. It is TV-certified for
With integrated digital cause spurious trips or fail to use in all SIL 1, SIL 2 and SIL 3 safety
communications and device perform. Digital HART applications as defined by
diagnostics from the sensor, to the communications is the enabler. IEC 61508.
logic solver, to the final control This approach increases process
element, DeltaV SIS shuts down availability and reduces
your plant when needed for safety, lifecycle costs.
but keeps you running safely when
non-critical components fail. 24/7 Safety
Pressure to keep your plant safe 24
Safety instrumented systems hours a day, 7 days a week is
perform a critical role in providing relentless. Equipping your safety
safer, more reliable process instrumented system with todays
operations. Based on industry digital technologies is your best
research, over 92% of all faults in path to addressing this
SIS application occur in field requirement. A highly reliable
instruments and control elements. safety system starts with
Therefore, it is critical to consider predictive intelligence, which
the entire safety instrumented provides a wealth of diagnostic Smart devices deliver
function as a complete entity. As a information, enabling you to predictive and health
smart solution, DeltaV SIS predict and prevent problems diagnostics
continuously monitors the ability before they occur. DeltaV SIS is a By replacing switches with
of sensors, logic solvers and final comprehensive solution for your transmitters, you take the first step
safety system with the power of toward reducing undetected
embedded digital communi- failures. Smart transmitters have
cationsall day, every day. far fewer dangerous undetected
failures than switches. Emersons
Smart logic solver smart sensors, such as
Bulky multiplexers with traditional Rosemount TM and Micro MotionTM
logic solvers can now be replaced devices, go beyond detecting
with state-of-the-art logic solvers component failures. They evaluate
that support digital the performance of the complete
communications to continuously measurement system, extending
monitor the health of the entire diagnostics to detect formerly
SIF. The DeltaV SIS logic solver, undetectable dangerous failures
built for digital communications outside the physical bounds of the
with safety sensors and final transmitterproviding both
control elements, uses the power transmitter and process
of predictive field intelligence to diagnostics.

Page 6DeltaV SIS


The end result is greater credit for Being able to monitor the health of the
equipment positions us to be proactive with
our maintenance programs. This helps us


failure-on-demand calculations,
easier compliance with IEC 61511
guidelines, higher safe failure improve overall availability.
fractions, less redundancy, less
George Cushon
proof-testing and longer intervals
OPTI Canada Inc.
between proof-tests.

Smart partial stroke


testing extends test components are required to The SIL-PAC solution incorporates
intervals automate partial stroke tests. Emersons industry-leading
Partial stroke testing of valves can Partial stroke test results are actuators, digital valve controllers,
improve safety integrity and automatically recorded in the solenoids, and valves to provide a
extend the time between DeltaV Event Chronicle for easy complete SIL 3-certified valve
mandatory proof-tests. Partial documentation. solution:
stroke testing results in increased n BettisTM G and CBA actuators
confidence that the valve will Smart final elements n FisherTM DVC6000 series SIS
perform on demand while reduce risk
reducing costs. Partial stroke tests FIELDVUETM digital valve controller controllers
can be automatically initiated by instruments provide automated n ASCOTM solenoids
the DeltaV SIS logic solver or performance monitoring and n FisherTM valves.
manually initiated from standard remote testing. This keeps
operator faceplates. The DeltaV SIS personnel safely away from the Asset management
system communicates with the valve's location. This keeps helps increase plant
DVC6000 series SIS via the HART personnel safely away from the availability
protocol so no additional wiring or valves location. The FIELDVUE AMS Suite: Intelligent Device
DVC6000 series SIS for emergency Manager enables you to monitor
shutdown applications is third- and maintain field devices.
party certified for use in SIL 3 Intelligent device diagnostic
applications. information allows staff to respond
quickly and prevent unexpected
FIELDVUE instruments have downtime. Automatic
extensive diagnostics to monitor documentation provides complete
travel deviation, pressure device maintenance records.
deviation, valve packing friction
and more. Information is
communicated back to the
DeltaV SIS system and the AMSTM
Device Manager software.

Page 7DeltaV SIS


MODERN ARCHITECTURE
DeltaV SISModern safety that is smart and flexible.


The DeltaV SIS modern approach
to safety reduces risk to your
operations in multiple ways.
DeltaV SIS was best suited for our safety
Electronic marshalling provides
unprecedented flexibility to easily shutdown applications because of its
change or expand your safety
modularity, integration with the control


systemflexibility that lets you
separate engineering from logic
configuration. SIS CHARMs
systems and safety loop diagnostics.
connect to any I/O type. Steve Schmitz
Rohm and Haas
In addition to reducing your
installation, re-work and
commissioning costs, DeltaV SIS
electronic marshalling and
characterization module (CHARM)
technologies reduce your
equipment footprint. It eliminates
traditional marshalling cabinets
and gives you freedom to connect
existing loop wiring to a single
CHARMs terminal block or land
new or existing I/O to field
enclosures near your devices
either way, you free up
footprint for future expansion
or modification.

Modern means taking full


advantage of smart instrumen-
tation to continuously monitor
your entire safety loop, ensuring it
will perform on demand when its
needed and not shut you down
when it shouldnt.

Smart, flexible modern safety to


meet your present and future
safety needsconfidently.

Page 8DeltaV SIS


Engineering Operations Maintenance Application Station

The modern DeltaV SIS is IEC 61508 certified for use in SIL 3 applications and provides
a comprehensive solution for your process safety system.

n Modern, smart SIS for optimized reliability with constant monitoring of safety status
and loop health
n Flexibility with CHARMs eliminates traditional marshalling
n Modular DeltaV SIS logic solver with configurable HART I/O
n Embedded digital field communications and integrated asset management
n Integrated operations environment with easy access to all safety and control information
n Intuitive function block engineering environment with integrated change management
n Automatic event reporting of safety information

Page 9DeltaV SIS


MODIFY AND EXPAND CONFIDENTLY
Modifications or additions to your control system can mean excessive engineering
re-work to your safety system. And with demanding standards and regulations,
verifying those changes can be complex and time-consuming.
The modern DeltaV SIS builds in These technologies were
unprecedented flexibility so you developed in response to
can evolve your safety system customers with moving offshore
confidently and cost-effectively. oil platforms where home run
It does this with electronic wiring means crucial added weight
marshalling and CHARM as well as high installation costs,
technologies, which let you (and every square inch of
separate safety loop installation automation system footprint is
from logic configuration. That severely limited). Electronic
means you can start hardware marshalling lets you land whole
design earlier in the engineering groups of safety loops in nearby
processbefore HazOps field enclosures, running a
completion. redundant Ethernet cable to
the controller.

Footprint constraints with layers of


past configuration loops
abandoned in place are no
problem. Simply re-connect the
existing wiring from active loops to
a single CHARMs base plate in any
order or configuration, and youll Flexible architecture
actually create extra space for later The unique, modular distributed
use. Move traditional I/O into field architecture enables you to
enclosures closer to field custom fit the system for your SIS
instrumentslanding wires where applications. Modularity gives you
they fit bestregardless of their the flexibility to meet changing
I/O type. CHARMs I/O take up project requirements. The DeltaV
about / the space of traditional SIS architecture is flexible to help
I/O and marshalling cabinets. provide the safety you need, when
and where you need it.
Applications that require safety
instrumented systems to reduce Whether you have an isolated
risk come in all sizes. You need an boiler or a large ESD application,
SIS that can handle the smallest to the DeltaV SIS system scales to
the largest application and the provide the safety coverage you
flexibility to address widely require for your SIL 1, SIL 2 and
distributed architectures. SIL 3 applications.

Page 10DeltaV SIS


Lower your risks with a
CHARMs Smart Logic modern safety system:
Solver
The DeltaV SIS CHARMs Smart All communications are n Optimized safety reliability
Logic Solver (CSLS) provides completely redundant from the
channel (LS-CHARM) to the CSLS.
n Increased engineering flexibility to meet
flexibility and ease of use with
Emersons Electronic Marshalling Integrated HART I/O,as well as your project needs
solution. Each CSLS provides I/O conventional wiring and device n Increased overall reliability
processing, SIL 3-capable logic alerts, brings field diagnostics into n Simplified safety lifecycle management
solving, and diagnostics in a single the CSLS.
n I/O anywhere you need it
logic solver.
CSLS key features include: n Reduced installed cost of system
The CSLS supports up to 96 n quad-modular redundant logic n Fully redundant communications
individually configurable channels, processing n Field mounted capable hardware
allowing flexibility for imple- n quad-voting on output channels
n Plug & play I/O
menting safety instrumented n separate power
n same input data for each logic n No single point of failure
functions, and its designed
specifically to eliminate solver n Isolation of changes and maintenance
conventional marshalling. Several n continuously drives output n SIF-based approach to logic solving
CSLS can be combined to use channels if a redundant partner n Adding new SIFs does not affect existing
1536 I/O on the same local safety fails
n online proof testing
SIF logic, scan rate, or execution
network and grow to as much as
30,000 I/O. n in-situ hardware and software n SIL 3 certified without restriction
upgrades. n Scalable from 2 to 30,000 I/O
n Remote I/O capability
n SIL 3 certified safety communications
n Up to 62 km distances between nodes

Page 11DeltaV SIS


REDUCE COMPLEXITY
AND ENGINEERING EFFORTS
With traditional SIS, initial configuration requires extensive customization and
any change in process design means extensive rework. And testing
DeltaV SIS makes it easier.
The modern DeltaV SIS certified, voter blocks with bypass
pre-configured function blocks management reduce what used to
simplify SIS application be pages and pages of ladder logic
implementation. No custom code or custom programming to
is required to implement SIS tasks engineer, test, and commission
with the IEC 61508-certified into a simple drag-and-drop
function blocks, providing faster configuration activity. Using
configuration and troubleshooting standard function blocks instead
of SIS logic. of custom programming makes it
easy for engineers to troubleshoot
Standard operator faceplates and maintain logic, even if they did
automatically provide detailed not create it.
safety information with no
configuration. Using these Voter function blocks
function blocks can help eliminate Voter function blocks provide
engineering hours previously advanced features like built-in
needed to implement ESD, FGS, bypass and deviation alarms to
and BMS applications. The improve plant safety. The voting is
certified function blocks deliver configured to ensure the same
powerful functionality out of the approach is taken throughout the
box, simplifying the imple- configuration, regardless of the
mentation of complex application size.
SIS applications.
Voter blocks include advanced
Intuitive safety software features such as maintenance and No more. With the CEM function
functions startup bypasses with a variety block, the cause-and-effect
The DeltaV SIS provides a full of options to meet your diagrams can be deployed directly
palette of smart safety function application needs. in the logic solver, enabling fast
blocks certified by TV for safety configuration and reduced testing.
applications. Special blocks like Cause-and-effect The CEM table executes as it is
function blocks presented, making documen-
Traditional SIS project tation easy.
requirements are typically
detailed using cause-and- CEM function blocks include
effect matrices (CEM). Once advanced functionality to handle
approved, these are often trip status, resetting and forcing
translated into logic of outputs.
diagrams and ultimately
into ladder logic.

Page 12DeltaV SIS


State transition and step Status handling
sequencer function Input processing provides status
blocks handlingno custom code
Function blocks for state needed; and different options are
transitions and step sequencing available. For example, voter
provide powerful functionality out blocks can automatically degrade
of the box for BMS applications. voting when an input value is bad.
These function blocks convert With integrated HART I/O, device
what is typically a very diagnostic information is
complicated set of custom logic automatically presented to
into a simple, intuitive operations with no additional
configuration task that is easy to configuration.
implement, troubleshoot and
maintain. Templates can be Sequence of events
created and re-used for all types of Built-in sequence of events
applications, including BMS. handler with automatic first-out
trapping eliminates hours of
Standard design templates make engineering while reducing testing
configuring operator graphics easy and simplifying maintenance.
for voter, CEM, state transition and
step sequencer function blocks. Status information is automatically
presented to the operator without
Other capabilities that make the mapping data tags or creating
TV-certified DeltaV SIS software custom templates or faceplates.
intuitive include:
n built-in sequence of events
handler with automatic first-out
Discover the Benefits:
trapping with 1msec resolution
n built-in maintenance bypasses
n facilitates compliance to IEC
n Implement complex logic in a single module, eliminating pages of custom
61511 standard programming
n built-in alarm management n No custom code needed to implement common tasks
n standard operator faceplates n Simplified configuration and troubleshooting of logic
automatically provide
n Consistent approach throughout SIS applications
safety information with
no configuration. n Significantly reduce engineering hours required to implement ESD, FGS
and BMS applications
n Rich function block information
n No concerns for migration to future releases

Page 13DeltaV SIS


SIMPLIFY COMPLIANCE
Change management of your traditional SIS is expensive, complex, and
introduces risk of errorerrors that ripple through your documentation.

Certified for use in SIL3


applications without
restriction.
Modern DeltaV SIS is built for IEC
61511 to simplify regulatory
compliance, with documentation
tools that can eliminate risk of
error and improper imple-
mentation. DeltaV SIS provides
stringent change management,
asset management, security
management and documentation
control. The system is built from
the ground up to simplify
regulatory compliance.
The DeltaV SIS
Change Management system is built for
Increasingly stringent regulations IEC 61511
compliance.
require manufacturers to provide
comprehensive documentation of
their process. DeltaV SIS Version
Control and Audit Trail (VCAT) is a on a master DeltaV SIS system change histories for any item in the
powerful tool that tracks changes and then distributed to configuration database.
and manages revision information engineering centers for
for any item in the configuration implementation. The templates By keeping detailed historical
database. This application creates are protected from modification information on configuration
and maintains a change history for by only allowing changes to occur items, the system automatically
configuration items, such as SIS on the master system. maintains data for regulatory
modules, user accounts and compliance requirements and
operator graphicsmaking Easy to track changes troubleshooting.
regulatory compliance simpler. Comprehensive version control of
a configuration item is Ensure authorized configuration
Protected composite templates automatically tracked and changes
For reduced complexity in global updated. The new version is time- The DeltaV SIS security system
engineering and IEC 61508 stamped and a history comment gives you the ability to grant
compliance, the DeltaV SIS system can be recorded when the item is privileges to individual users. Items
includes protected composite checked back in. Embedded may be checked out for editing
templates. Templates, such as reporting tools give engineers the only by approved users.
certified safety logic, are created ability to print configuration

Page 14DeltaV SIS


Ensure compliance during are immediately applied across all integrated device configuration
operation with Electronic DeltaV and AMS applications and and security to reduce lifecycle
Signatures Windows security is automa- costs. QuickCheck allows for easier
To support compliance tically updated. interlock verification.
requirements for online changes,
DeltaV SIS uses an electronic Built for security Documentation control
signature functionality designed to DeltaV SIS was developed with Syncade Smart Operations
meet the life science industrys system security as a key design Management suite provides
stringent requirements. Any criterion. To safeguard your assets electronic manufacturing control
actions taken can be configured to and ensure proper access, the that optimizes plant-wide work
require a confirmation in which the system delivers these security processes and increases
users name and password is capabilities: productivity. Safety workflow,
needed to execute, as well as an n Workstation hardening disables such as proof-testing, is guided,
additional verifying user name and unused operating system verified, and documented for easy
password if required. services and disables CDROM regulatory compliance.
and USB ports to prevent the
Security introduction of viruses and
Adaptable User Manager malware.
With the role-based user access, n Unauthorized network devices
you have complete flexibility to cannot participate in DeltaV SIS
define the security structure to communications, because
match your operating philosophy. DeltaV SIS devices are
For integrated systems, a separate authenticated as part of system
set of locks and keys is provided for configuration.
control and safety. Through a n Physical access to local Discover the Value:
single sign-on, you can define equipment is not required for
groups of users and assign them routine maintenance procedures
privileges. For example, one group and troubleshooting because n IEC 61511 compliance is enforced by
may be able to change only control system diagnostics are done engineering tools, with no restrictions
operating parameters, while over the network using DeltaV n Change management of safety logic
another may be able to change SIS and AMS Device and field device
safety parameters. And you can Manager workstations.
limit a user to particular areas of n Custom build switches with pre-
configuration/calibration
the plantproviding you with determined configuration. n Integrated security for competency
peace of mind that only the management
appropriate people are making n Secure write mechanism enforces
decisions affecting your plant. Asset management
confirmation for online changes
When maintenance functions are
Easy security management performed, AMS Device Manager n Automatic logging of events and
When you make changes to automatically records activity in diagnostic faults
system users and their privileges in the Audit Trail for a complete
DeltaV User Manager, the changes history. AMS Suite provides

Page 15DeltaV SIS


FLEXIBLE INTEGRATION
Separate systems that dont talk to one another require complex
data-mapping and multiple databases to talk to each other. Standalone,
interfaced or integratedDeltaV SIS meets your needs.
Connecting to existing The modern IEC61508-
BPCS certified DeltaV SIS
As a modern standalone safety gives a common
system, DeltaV SIS can easily interface with your
integrate with any DCS or PLC control system to
using interfaces that are based on monitor assets and
open communication standards, deliver crucial data for
such as Modbus, OPC and safer, more robust
OPC.Net. operations.
SIS Network
Modbus integration While DeltaV SIS can
Modbus TCP can be used to interface with any
integrate the DeltaV SIS and your control system, it can
BPCS. Modbus brings the also be integrated with
advantage of familiarity to most the DeltaV system,
users, as well as the comfort of providing increased
decades of proven reliability. visibility into your Integrated operations,
process. DeltaV SIS is engineering and maintenance.
OPC.Net and OPC integrated with the
DeltaV SIS can connect with your DeltaV systems and IEC 61511 standards. This
non-DeltaV BPCS via OPC or engineering, maintenance and system automatically monitors,
OPC.Net. All information is operations environment. All controls and collects safety-
available to your operator safety-related information is easily related data.
interfaces and history collection accessible through familiar and
software as part of an integrated intuitive applications. The Operations
solution. integrated yet separate The operator interface provides a
architecture meets IEC 61511 powerful environment with built-in
OPC.Net is a data communications requirements for physical features for easy information
interface developed by many separation and independence of access. Alarm management,
diverse process automation safety and control. operator navigation, standard
suppliers. OPC.Net connectivity
faceplates and detail displays
provides secure, robust, firewall- Architecturally provide a consistent and intuitive
friendly data access to real-time independent safety operating environment.
and historical process data, as well system
as real-time alarm and event data. The DeltaV SIS power supplies, To more effectively run your plant,
The OPC communications communication channels, operators have one common
standard has served the process hardware and real-time operating operating environment for both
industry well for over a decade. It systems are physically separate the basic process control system
supports access to real-time and and independent of the control (BPCS) and SIS when using the
historical data, as well as alarm and system, maintaining the DeltaV control system. This
event data. separation required by IEC 61508 integrated operator interface

Page 16DeltaV SIS


combines alarm handling, time aspects of your system con-
synchronization, user security and figuration, including hardware Discover the Benefits:
device health monitoring. configuration, control strategies,
built-in change management n Reduced safety lifecycle costs
Should an emergency stop be and history. DeltaV SIS maintains r Equipment and installation costs
required for the application, two proper security on safety logic
r Engineering and maintenance costs
mechanisms may be used. You software and makes managing
may hard-wire a physical required safety logic modifi- n Reduced training costs
emergency shutdown mushroom cations easier. n Easier regulatory compliance
n Robust security
For DeltaV BPCS users, the
integrated configuration
environment simplifies and
streamlines the engineering effort. Integration Features
This integrated approach
eliminates time-wasting, difficult-
to-maintain data mapping and n Simplified architecture with no data
handshaking logic that is common mapping
with disparate systems. n Integrated engineering, maintenance and
operations environment
Maintenance
button to the input of a logic To manage change and maintain n Time synchronization and event collection
solver. You may also soft-wire an compliance over time, DeltaV SIS n Security management with user
emergency shutdown and display provides comprehensive version authentication
it on an SIS graphic on the control and audit trail functionality
n Advanced alarm management
operator station. To comply with for required engineering
IEC 61511, the DeltaV SIS system modifications. Electronic n Change management including version
requires a repeat confirmation on signatures ensure proper control, audit trail and electronic signatures
the emergency shutdown action authorization for online changes.
before it will take effectavoiding To support compliance docu-
an accidental shutdown. mentation requirements, a
comprehensive history of plant
Separation Features
Engineering safety events is automatically
DeltaV SIS gives you the benefits of recorded. AMS Device Manager n Built-in IEC 61511 compliance
drag-and-drop function block provides detailed information to n Separate hardware for control and safety
configuration, comprehensive diagnose device problems quickly n Separate power for control and safety
security and explorer-based and correctly. It also documents
n Separate control and safety networks
software for intuitive project and archives instrument con-
implementation. The engineering figurations and changes, as well as n Gateway between SIS and control network
software allows you to manage all health information and alarms. provides firewall protection

Page 17DeltaV SIS


CERTIFIED SAFETY LIFECYCLE
MANAGEMENT SERVICES
Providing industry leading services throughout the lifecycle of your operations,
no matter where on the globe you operate.

Managing risk with implement a safety system that is


consistent with the most stringent
global standards demands for protection, risk
Companies that correctly plan for reduction and reliability.
and manage the operational risks
inherent to industrial processes
avoid exposure to production Certified safety experts
outages, equipment damage, IEC 61511 requires personnel and
environmental incidents, injury to organizations to be competent
personnel and loss of life. and qualified to carry out
safety activities.
International standards for the
evaluation and design of safety Emerson has committed the
functions for total process plant resources to become the first
operations cover the whole safety systems provider to develop
lifecycle of the safety system from TV-certified procedures in
concept to operation, alignment with IEC 61511. In
maintenance, function testing, addition, all employees involved
through to decommissioning. with safety system engineering
and development are required to
Emerson Process Management complete extensive safety training exam. This certification requires a
offers the total solution to and Emerson certification. minimum amount of experience in
provide the certified hardware, safety instrumented systems (SIS)
software, and engineering services Many of our engineers and field, as well as successful
needed to meet the requirements technologists have also completed completion of a comprehensive
of the safety system lifecycle. a rigorous competency examination.
qualification for system design
Certified safety process engineers known as the Certified
Functional Safety Expert (CFSE) Reducing failures from
Emerson uses a Functional Safety
the start
Management System as defined
Reducing random hardware
by the IEC 61511 standard. This
failures and reducing systematic
TV-certified system covers:
failures are what IEC 61511 is all
n Management of functional
about. Having CFSE experts
safety involved early in the process helps
n Safety lifecycle structure/ ensure that systematic faults,
planning caused by poor specifications or
n Verification poor engineering, are reduced.
n Design and engineering of SIS up This is critical because 80% of all
to decommissioning SIS-related failures can be
attributed to design and
Emersons certified functional implementation errors. Omissions
safety experts apply this process in the design of a safety loop or
and their expertise with the latest safety instrumented functions
safety technologies and proven (SIF) could remain undiscovered
practices to help you define and until an incident occurs.

Page 18DeltaV SIS


Differentiated safety
services throughout the
safety lifecycle
Emerson provides solutions with
certified hardware, software, and
engineering services needed to
meet the requirements of the
safety system lifecycle. Emerson
has extensive global coverage for
main automation contractor
(MAC) servicesproviding a single
source for all of your project
needs. These services include all
aspects of your automation
project from front end engineering
design (FEED) onward. Emerson
can provide a turnkey solution for
your project that includes
equipment selection, Globally, Emerson can help you with IEC 61511 Safety Life Cycle management.
commissioning services, and
implementation and operational
capabilities. Operation Globally balanced
Emersons SureServiceTM program capabilities
Analysis offers an array of support services
For over 100 years, Emerson has
Once the safety integrity levels designed to help you achieve your
been a global leader in providing
(SIL) of the safety instrument business objectives, reduce your
process automation solutions with
functions (SIF) are defined, operating and service costs, and
a commitment to total quality,
Emerson can compile your safety keep your systems running at peak
plant safety, and dedication to
requirement specification (SRS). performance. These support
meeting customer expectations.
We also offer SIS functional safety services include:
We can help you operate your
consulting to help you design the n Emergency Onsite Service plant safely, reliably, and more
safety loop n Express Module Replacement efficientlygiving you peace
and select the components that n Critical Data Backup of mind.
are needed. n Local Spares Management
n Functional Safety Maintenance
Implementation and Proof-Testing
Emerson project services for
n Power and Grounding Integrity
application software follow our
n Security Assessment
TV-certified processes and
provide documented verification n Alarm Management
of all design, implementation, and n SIS Modifications
testing activity. Each step of the n Extended Software Support.
process is reviewed and
documented to help ensure
compliance with IEC 61511.

Page 19DeltaV SIS


We recommend the following:

Safety Lifecycle Workbook for


the Process Industry Sector
www.DeltaVSIS.com/workbook

Emerson Process Management The contents of this publication are presented for informational purposes only, and while every effort has been made to
1100 W. Louis Henna Blvd., Building One ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products
Round Rock, TX 78681-7430 or services described herein or their use or applicability. All sales are governed by our software licensing agreement and
terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or
www.DeltaVSIS.com specifications of our product and services at any time without notice.

2013 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson
Electric Co.

For Emerson Process Management trademarks and service marks, go to www.emersonprocess.com/home/news/resources/marks.pdf.


Form B-000015 / 10K AQ / 5K A4 / 09-13 All other marks are the property of their respective owners.