This document calculates the efficiency of a rotary screw compressor at a nitrogen PSA (Pressure Swing Adsorption) system. It provides equations for polytropic coefficient and compressor power based on suction and discharge parameters. Using measured running electrical parameters and assumed mechanical losses, it calculates the compressor efficiency in two ways that both give a result of 60.04%.
This document calculates the efficiency of a rotary screw compressor at a nitrogen PSA (Pressure Swing Adsorption) system. It provides equations for polytropic coefficient and compressor power based on suction and discharge parameters. Using measured running electrical parameters and assumed mechanical losses, it calculates the compressor efficiency in two ways that both give a result of 60.04%.
This document calculates the efficiency of a rotary screw compressor at a nitrogen PSA (Pressure Swing Adsorption) system. It provides equations for polytropic coefficient and compressor power based on suction and discharge parameters. Using measured running electrical parameters and assumed mechanical losses, it calculates the compressor efficiency in two ways that both give a result of 60.04%.
Calculating Rotary Screw Compressor Efficiency at N2 PSA
Polytropic Coefficient is defined by n 1 see Ref_1.pdf n T2 P2 eq1 T1 P1 Suction Parameters Discharge Parameters
T1 31 273 K P1 1 bar T2 161 273 K P2 7.4 bar
3 m n Q 10.6 solve eq1 ,n min n 1.2164 Gas Constant for air J Compressor Power is defined by R 287.1 kg K Rearrangement of ideal gas law see Ref_1.pdf n 1 P1 Q kg n QM 0.2024 R T1 s n Q P1 P2 Power 1 see Ref_2.pdf n QM R T2 T1 n 1 P1 Powerother n1 Power eval Power 42472.249 W Powerother 42472.1547 W Compressor Electrical Parameters Observed Parameters Assumed Parameters Assumed 5% Mechanical Losses
RunningLoad 134 A cos 0.85 MechanicalEff 0.95
Volt 403 V MotorEff 0.9 RunningElectricalPower 1.732 Volt RunningLoad cos MotorEff RunningElectricalPower eval RunningElectricalPower RunningElectricalPower 71551.57 W Compressor Efficiency% 1st solution